Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “background radiation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Misclassification of primary liver cancer in the Life Span Study of atomic bomb survivors

Primary liver cancer is difficult to diagnose accurately at death, due to metastases from nearby organs and to concomitant diseases, such as chronic hepatitis and cirrhosis. Trends in diagnostic accuracy could affect radiation risk estimates for incident liver cancer by altering background rates or by impacting risk modification by sex and age. We quantified the potential impact of death‐certificate inaccuracies on radiation risk estimates for liver cancer in the Life Span Study of atomic bomb survivors. True‐positive and false‐negative rates were obtained from a previous study that compared death‐certificate causes of death with those based on pathological review, from 1958 to 1987. We assumed various scenarios for misclassification rates after 1987. We obtained estimated true positives and estimated false negatives by stratified sampling from binomial distributions with probabilities given by the true‐positive and false‐negative rates, respectively. Poisson regression methods were applied to highly stratified person‐year tables of corrected case counts and accrued person years. During the study period (1958–2009), there were 1,885 cases of liver cancer, which included 383 death‐certificate‐only (DCO) cases; 1,283 cases with chronic liver disease as the underlying cause of death; and 150 DCO cases of pancreatic cancer among 105,444 study participants. Across the range of scenarios considered, radiation risk estimates based on corrected case counts were attenuated, on average, by 13–30%. Our results indicated that radiation risk estimates for liver cancer were potentially sensitive to death‐certificate inaccuracies. Additional data are needed to inform misclassification rates in recent years.

French, Benjamin↗

Network Algorithms for Detection of Radiation Sources

In support of national defense, Domestic Nuclear Detection Office’s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) a notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2”*2” NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev’s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Dose received by occupationally exposed workers at a nuclear medicine department

Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.

61 RADIATION PROTECTION AND DOSIMETRY↗

A New Approach to Reduce Uncertainties in Space Radiation Cancer Risk Predictions

The prediction of space radiation induced cancer risk carries large uncertainties with two of the largest uncertainties being radiation quality and dose-rate effects. In risk models the ratio of the quality factor (QF) to the dose and dose-rate reduction effectiveness factor (DDREF) parameter is used to scale organ doses for cosmic ray proton and high charge and energy (HZE) particles to a hazard rate for γ-rays derived from human epidemiology data. In previous work, particle track structure concepts were used to formulate a space radiation QF function that is dependent on particle charge number Z, and kinetic energy per atomic mass unit, E. QF uncertainties where represented by subjective probability distribution functions (PDF) for the three QF parameters that described its maximum value and shape parameters for Z and E dependences. Here I report on an analysis of a maximum QF parameter and its uncertainty using mouse tumor induction data. Because experimental data for risks at low doses of γ-rays are highly uncertain which impacts estimates of maximum values of relative biological effectiveness (RBE max ), I developed an alternate QF model, denoted QF γAcute where QFs are defined relative to higher acute γ-ray doses (0.5 to 3 Gy). The alternate model reduces the dependence of risk projections on the DDREF, however a DDREF is still needed for risk estimates for high-energy protons and other primary or secondary sparsely ionizing space radiation components. Risk projections (upper confidence levels (CL)) for space missions show a reduction of about 40% (CL~50%) using the QF γAcute model compared the QFs based on RBE max and about 25% (CL~35%) compared to previous estimates. In addition, I discuss how a possible qualitative difference leading to increased tumor lethality for HZE particles compared to low LET radiation and background tumors remains a large uncertainty in risk estimates.

59 BASIC BIOLOGICAL SCIENCES↗

Generation of plasma waves by thick-target electron beams, and the expected radiation signature

The production of plasma waves by a nonthermal beam of high-energy electrons injected into a background thermal plasma was investigated. The coupled kinetic equations for nonthermal electrons were solved, and the level of the plasma waves produced by the bump-on-tail instability arising as a result of the Coulomb collisions of nonthermal electrons with background plasma was estimated. In addition, the radiation signatures of these waves were examined. It is shown that the wave-particle interactions have a significant effect on the overall distribution of the electrons and that it is unlikely that such effects can be discerned in the observed bremsstrahlung or synchrotron radiation of the nonthermal electrons. However, a significant fraction of the energy lost by the beam is transferred to plasma waves and is then dissipated by the thermal plasma.

Hamilton, Russell J.↗

Approaches to Deal with Irradiated Graphite in Russia - Proposal for New IAEA CRP on Graphite Waste Management - 12364

The problems of spent reactor graphite are being shown, the options of its disposal is considered. Burning method is selected as the most efficient and waste-free. It is made a comparison of amounts of {sup 14}C that entering the environment in a natural way during the operation of nuclear power plants (NPPs) and as a result of the proposed burning of spent reactor graphite. It is shown the possibility of burning graphite with the arrival of {sup 14}C into the atmosphere within the maximum allowable emissions. This paper analyzes the different ways of spent reactor graphite treatment. It is shown the possibility of its reprocessing by burning method in the air flow. It is estimated the effect of this technology to the overall radiation environment and compared its contribution to the general background radiation due to cosmic radiation and NPPs emission. It is estimated the maximum permissible speeds of burning reactor graphite (for example, RBMK graphite) for areas with different conditions of agricultural activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A short-range objective nocturnal temperature forecasting model

A relatively simple, objective, nocturnal temperature forecasting model suitable for freezing and near-freezing conditions has been designed so that a user, presumably a weather forecaster, can put in standard meteorological data at a particular location and receive an hour-by-hour prediction of surface and air temperatures for that location for an entire night. The user has the option of putting in his own estimates of wind speeds and background sky radiation which are treated as independent variables. An analysis of 141 test runs show that 57.4% of the time the model predicts to within 1 C for the best cases and to within 3 C for 98.0% of all cases.

Sutherland, R. A.↗

Galactic Noise and Passive Microwave Remote Sensing from Space at L-Band

The spectral window at L-band (1.4 GHz) is important for passive remote sensing of parameters such as soil moisture and ocean salinity best measured at long wavelengths. At L-band, radiation from extraterrestrial (galactic) sources is strong enough to warrant inclusion in calibration and retrieval algorithms and unlike the constant cosmic background is spatially variable. Previous estimates of the magnitude and distribution of this background radiation have been rather coarse, However, recent surveys of the radio sky at 1.4 GHz have made it possible to produce maps with sufficient spatial and radiometric accuracy to be relevant to remote sensing applications. This is of particular concern for remote sensing of sea surface salinity because the surface (water) is a good reflector and the salinity signal is relatively small. This paper presents a modem map of the radiometric sky at L-band and a solution to the problem of determining the portion of the sky seen by a radiometer in orbit. The data is derived from recent radio astronomy surveys and is presented as equivalent brightness temperature suitable for remote sensing applications. Examples using orbits and antennas representative of those contemplated for remote sensing of soil moisture and sea surface salinity from space are presented to illustrate the signal levels to be expected. Radiation near the galactic plane can exceed several kelvin.

LeVine, D. M.↗

Evaluating the Feasibility of Data Simulation for Radiation Research: Estimating RBE Values for HZE Radiation

As the drive for deep space exploration intensifies, a comprehensive understanding of the health effects of radiation exposure becomes paramount to the future of human space flight. However, epidemiological data for radiation exposure, particularly to high-energy (HZE) ions, is limited, partially due to the financial and logistical costs of radiation studies. As an alternative, this study aims to assess the viability of data simulation strategies to accurately model potential study parameters prior to utilizing laboratory conditions. This study estimates a relative biological effectiveness (RBE) factor based on the solid tumor data for outbred mice provided by Edmundson et al. 2020. Excess relative risk (ERR) models for HZE-Fe ions and gamma radiation were estimated using Poisson regression with Weibull models to represent the background solid tumor hazard without radiation. RBE values were calculated from the ratio of the heavy ion linear slope to the gamma linear slope. The parameters from these models were then applied to simulate iterations of 300 datasets across HZE-Fe doses of 0.05, 0.2, 0.4, and 0.75 Gy; gamma radiation doses of 0.75, 2, and 3 Gy, as well as an unirradiated control group. Sample size per dose varied from 100-500 mice across simulations (800-4000 mice total per dataset). 1500 datasets were generated total (300 each for sample sizes 800, 1600, 3200, and 4000). For each dataset, ERR per radiation type and RBE for HZE-Fe were calculated. The RBE from the Edmondson data was calculated to be 5.55. The RBEs from the simulated data converged around this value across the increasing sample sizes. For n = 4000, the mean RBE across the 300 datasets was 5.71 (95% CI: 5.47-5.95). These results suggest that RBEs calculated from simulated data are credible. Based on this exploration, data simulation is a viable method of testing radiation studies. It provides a method of testing study assumptions and refining research questions prior to embarking on costly laboratory experiments.

Sneha Mehta↗

A Revised Look at Relativistic Electrons in the Earth's Inner Radiation Zone and Slot Region

We describe a new, more accurate procedure for estimating and removing inner zone background contamination from Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) radiation belt measurements. This new procedure is based on the underlying assumption that the primary source of background contamination in the electron measurements at L shells less than three, energetic inner belt protons, is relatively stable. Since a magnetic spectrometer can readily distinguish between foreground electrons and background signals, we are able to exploit the proton stability to construct a model of the background contamination in each MagEIS detector by only considering times when the measurements are known to be background dominated. We demonstrate, for relativistic electron measurements in the inner zone, that the new technique is a significant improvement upon the routine background corrections that are used in the standard MagEIS data processing, which can “overcorrect” and therefore remove real (but small) electron fluxes. As an example, we show that the previously reported 1-MeV injection into the inner zone that occurred in June of 2015 was distributed more broadly in L and persisted in the inner zone longer than suggested by previous estimates. Such differences can have important implications for both scientific studies and spacecraft engineering applications that make use of MagEIS electron data in the inner zone at relativistic energies. We compare these new results with prior work and present more recent observations that also show a 1-MeV electron injection into the inner zone following the September 2017 interplanetary shock passage.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of incomplete residential histories on studies of environmental exposure with application to childhood leukaemia and background radiation

Highlights: • Residential exposures are most important for many environmental carcinogens. • Direct measurement in all occupied homes is the gold standard but may be impractical. • About half of cases of childhood cancer have not moved between birth and diagnosis. • Most house movements are short-range; exposures in successive houses are correlated. • Analyses using exposure estimation from a single address are informative. When evaluating environmental exposures, residential exposures are often most relevant. In most countries, it is impossible to establish full residential histories. In recent publications, childhood leukaemia and background radiation have been studied with and without full residential histories. This paper investigates the consequences of lacking such full data. Data from a nationwide Finnish Case-Control study of Childhood Leukaemia and gamma rays were analysed. This included 1093 children diagnosed with leukaemia in Finland in 1990–2011. Each case was matched by gender and year of birth to three controls. Full residential histories were available. The dose estimates were based on outdoor background radiation measurements. The indoor dose rates were obtained with a dwelling type specific conversion coefficient and the individual time-weighted mean red bone marrow dose rates were calculated using age-specific indoor occupancy and the age and gender of the child. Radiation from Chernobyl fallout was included and a 2-year latency period assumed. The median separation between successive dwellings was 3.4 km and median difference in red bone marrow dose 2.9 nSv/h. The Pearson correlation between the indoor red bone marrow dose rates of successive dwellings was 0.62 (95% CI 0.60, 0.64). The odds ratio for a 10 nSv/h increase in dose rate with full residential histories was 1.01 (95% CI 0.97, 1.05). Similar odds ratios were calculated with dose rates based on only the first dwelling (1.02, 95% CI 0.99, 1.05) and only the last dwelling (1.00, 95% CI 0.98, 1.03) and for subjects who had lived only in a single dwelling (1.05, 95% CI 0.98, 1.10). Knowledge of full residential histories would always be the option of choice. However, due to the strong correlation between exposure estimates in successive dwellings and the uncertainty about the most relevant exposure period, estimation of overall exposure level from a single address is also informative. Error in dose estimation is likely to cause some degree of classical measurement error resulting in bias towards the null.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Calculation of synchrotron radiation from high intensity electron beam at eRHIC

The Electron-Relativistic Heavy Ion Collider (eRHIC) at Brookhaven National Lab is an upgrade project for the existing RHIC. A 30 GeV energy recovery linac (ERL) will provide a high charge and high quality electron beam to collide with proton and ion beams. This will improve the luminosity by at least 2 orders of magnitude. The synchrotron radiation (SR) from the bending magnets and strong quadrupoles for such an intense beam could be penetrating the vacuum chamber and producing hazards to electronic devices and undesired background for detectors. In this paper, we calculate the SR spectral intensity, power density distributions and heat load on the chamber wall. We suggest the wall thickness required to stop the SR and estimate spectral characteristics of the residual and scattered background radiation outside the chamber.

43 PARTICLE ACCELERATORS↗

A neural-network based estimator to search for primordial non-Gaussianity in Planck CMB maps

We present an upgraded combined estimator, based on Minkowski Functionals and Neural Networks, with excellent performance in detecting primordial non-Gaussianity in simulated maps that also contain a weighted mixture of Galactic contaminations, besides real pixel's noise from Planck cosmic microwave background radiation data. We rigorously test the efficiency of our estimator considering several plausible scenarios for residual non-Gaussianities in the foreground-cleaned Planck maps, with the intuition to optimize the training procedure of the Neural Network to discriminate between contaminations with primordial and secondary non-Gaussian signatures. We look for constraints of primordial local non-Gaussianity at large angular scales in the foreground-cleaned Planck maps. For the SMICA map we found f{sub NL} = 33 ± 23, at 1σ confidence level, in excellent agreement with the WMAP-9yr and Planck results. In addition, for the other three Planck maps we obtain similar constraints with values in the interval f{sub NL} element of [33, 41], concomitant with the fact that these maps manifest distinct features in reported analyses, like having different pixel's noise intensities.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Radiation Detection Using a Mixed-Effects Statistical Model for Background Variation

In this paper, we consider radiation source localization in an urban environment as an inverse problem and use Bayesian parameter estimation techniques to infer the source location and intensity. Since parameter estimation generally requires a large number of model evaluations, we employ a simplified photon transport model, as in a 2017 paper by Stefanescu, et al., to reduce computational requirements. However, the model in the 2017 paper does not account for the physical reality that background radiation varies with position within an urban locale. We incorporate statistical mixed-effects modeling into the simplified transport equation from the Stefanescu, et al. paper to reflect individual variation among the background radiation measurements at multiple detector locations. With our new model, we use a Bayesian DRAM-within-Gibbs technique, which incorporates the Delayed Rejection Adaptive Metropolis (DRAM) algorithm, to estimate the mixed-effects parameters. We note that without adequate prior information, we were unable to simultaneously estimate the set of parameters corresponding to the source intensity, source location, and individual background radiation counts. By calibrating the background in the absence of a source, we obtained narrow prior distributions, which permitted us to jointly infer the source intensity and location and the background radiation distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for primordial non-Gaussianity in Planck CMB maps using a combined estimator

The extensive search for deviations from Gaussianity in cosmic microwave background radiation (CMB) data is very important due to the information about the very early moments of the universe encoded there. Recent analyses from Planck CMB data do not exclude the presence of non-Gaussianity of small amplitude, although they are consistent with the Gaussian hypothesis. The use of different techniques is essential to provide information about types and amplitudes of non-Gaussianities in the CMB data. In particular, we find interesting to construct an estimator based upon the combination of two powerful statistical tools that appears to be sensitive enough to detect tiny deviations from Gaussianity in CMB maps. This estimator combines the Minkowski functionals with a Neural Network, maximizing a tool widely used to study non-Gaussian signals with a reinforcement of another tool designed to identify patterns in a data set. We test our estimator by analyzing simulated CMB maps contaminated with different amounts of local primordial non-Gaussianity quantified by the dimensionless parameter f{sub NL}. We apply it to these sets of CMB maps and find ∼> 98% of chance of positive detection, even for small intensity local non-Gaussianity like f{sub NL} = 38±18, the current limit from Planck data for large angular scales. Additionally, we test the suitability to distinguish between primary and secondary non-Gaussianities: first we train the Neural Network with two sets, one of nearly Gaussian CMB maps (|f{sub NL}| ≤ 10) but contaminated with realistic inhomogeneous Planck noise (i.e., secondary non-Gaussianity) and the other of non-Gaussian CMB maps, that is, maps endowed with weak primordial non-Gaussianity (28 ≤ f{sub NL} ≤ 48); after that we test an ensemble composed of CMB maps either with one of these non-Gaussian contaminations, and find out that our method successfully classifies ∼ 95% of the tested maps as being CMB maps containing primordial or secondary non-Gaussianity. Furthermore, we analyze the foreground-cleaned Planck maps obtaining constraints for non-Gaussianity at large-angles that are in good agreement with recent constraints. Finally, we also test the robustness of our estimator including cut-sky masks and realistic noise maps measured by Planck, obtaining successful results as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte-Carlo Estimation of the Inflight Performance of the GEMS Satellite X-Ray Polarimeter

We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.

Monte-Carlo simulation↗

ON THE LINEAR TERM CORRECTION FOR NEEDLET/WAVELET NON-GAUSSIANITY ESTIMATORS

We derive the linear correction term for needlet and wavelet estimators of the bispectrum and the nonlinearity parameter f{sub NL} on cosmic microwave background radiation data. We show that on masked WMAP-like data with anisotropic noise, the error bars improve by 10%-20% and almost reach the optimal error bars obtained with the bispectrum estimator also known as 'KSW'. In the limit of full-sky and isotropic noise, this term vanishes. We apply needlet and wavelet estimators to the WMAP 7-year data and obtain our best estimate f{sub NL} = 37.5 {+-} 21.8 (68% CL).

79 ASTRONOMY AND ASTROPHYSICS↗