Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Relationship between Jovian Hectometric Attenuation Lanes And Io Volcanic Activity

Within the Galileo plasma wave instrument data a narrow (in frequency) attenuation band is seen in the hectometric (HOM) emission that varies in frequency with system III longitude. This attenuation lane is believed to be the result of near-grazing incidence or coherent scattering of radio emission near the outer edge of the Io torus, i.e., when the ray path is nearly tangent to an L shell containing the Io flux tube. Such a process should, therefore, be enhanced when the Io volcanic activity is increased and the Io flux tube has enhanced density. We have performed a systematic study of the existing Galileo radio emission data in an effort to determine the phenomenology and frequency of occurrence of the attenuation lanes and the association, if any, with published volcanic activity of Io. Our results indicate that the attenuation lanes are present almost all of the time but are enhanced on occasion. The best examples of attenuation lanes occur when Galileo is within approximately 65 R(sub J) of Jupiter and thus are probably more apparent because of the increased signal-to-noise ratio of the radio receivers. The lack of continuous monitoring of Io activity and the lack of known activity on the anti-Earthward side of Io are problematic and make detailed correlation with radio emission very difficult at this time. Nevertheless, if the data are displayed for periods when the spacecraft is within 65 R(sub J) (i.e., for each perijove pass), then the highest-contrast lanes occur on most passes when the Io volcanic activity is also high for that pass. These results support our current understanding of attenuation lane formation and suggest that future efforts can be made to better understand the interaction of HOM emission with the Io flux tube.

Menietti, J. D.↗

Retrieval of Raindrop Size Distribution, Vertical Air Velocity and Water Vapor Attenuation Using Dual-Wavelength Doppler Radar Observations

Two techniques for retrieving the slope and intercept parameters of an assumed exponential raindrop size distribution (RSD), vertical air velocity, and attenuation by precipitation and water vapor in light stratiform rain using observations by airborne, nadir looking dual-wavelength (X-band, 3.2 cm and W-band, 3.2 mm) radars are presented. In both techniques, the slope parameter of the RSD and the vertical air velocity are retrieved using only the mean Doppler velocities at the two wavelengths. In the first method, the intercept of the RSD is estimated from the observed reflectivity at the longer wavelength assuming no attenuation at that wavelength. The attenuation of the shorter wavelength radiation by precipitation and water vapor are retrieved using the observed reflectivity at the shorter wavelength. In the second technique, it is assumed that the longer wavelength suffers attenuation only in the melting band. Then, assuming a distribution of water vapor, the melting band attenuation at both wavelengths and the rain attenuation at the shorter wavelength are retrieved. Results of the retrievals are discussed and several physically meaningful results are presented.

Heymsfield, Gerald M.↗

Earth-Space Link Attenuation Estimation via Ground Radar Kdp

A method of predicting attenuation on microwave Earth/spacecraft communication links, over wide areas and under various atmospheric conditions, has been developed. In the area around the ground station locations, a nearly horizontally aimed polarimetric S-band ground radar measures the specific differential phase (Kdp) along the Earth-space path. The specific attenuation along a path of interest is then computed by use of a theoretical model of the relationship between the measured S-band specific differential phase and the specific attenuation at the frequency to be used on the communication link. The model includes effects of rain, wet ice, and other forms of precipitation. The attenuation on the path of interest is then computed by integrating the specific attenuation over the length of the path. This method can be used to determine statistics of signal degradation on Earth/spacecraft communication links. It can also be used to obtain real-time estimates of attenuation along multiple Earth/spacecraft links that are parts of a communication network operating within the radar coverage area, thereby enabling better management of the network through appropriate dynamic routing along the best combination of links.

Bolen, Steven M.↗

Significant Attenuation of Lightly Damped Resonances Using Particle Dampers

When equipment designs must perform in a broad band vibration environment it can be difficult to avoid resonances that affect life and performance. This is especially true when an organization seeks to employ an asset from a heritage design in a new, more demanding vibration environment. Particle dampers may be used to provide significant attenuation of lightly damped resonances to assist with such a deployment of assets by including only a very minor set of modifications. This solution may be easier to implement than more traditional attenuation schemes. Furthermore, the cost in additional weight to the equipment can be very small. Complexity may also be kept to a minimum, because the particle dampers do not require tuning. Attenuating the vibratory response with particle dampers may therefore be simpler (in a set it and forget it kind of way) than tuned mass dampers. The paper will illustrate the use of an "equivalent resonance test jig" that can assist designers in verifying the potential resonance attenuation that may be available to them during the early trade stages of the design. An approach is suggested for transforming observed attenuation in the jig to estimated performance in the actual service design. KEY WORDS: Particle Damper, Performance in Vibration Environment, Damping, Resonance, Attenuation, Mitigation of Vibration Response, Response Estimate, Response Verification.

Smith, Andrew↗

Comparison of Instantaneous Frequency Scaling from Rain Attenuation and Optical Disdrometer Measurements at K/Q bands

Rain attenuation is strongly dependent on the rain rate, but also on the rain drop size distribution (DSD). Typically, models utilize an average drop size distribution, such as those developed by Laws and Parsons, or Marshall and Palmer. However, individual rain events may possess drop size distributions which could be significantly different from the average and will impact, for example, fade mitigation techniques which utilize channel performance estimates from a signal at a different frequency. Therefore, a good understanding of the characteristics and variability of the raindrop size distribution is extremely important in predicting rain attenuation and instantaneous frequency scaling parameters on an event-toevent basis. Since June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have measured the attenuation due to rain in Milan, Italy, on the 20/40 GHz beacon signal broadcast from the Alphasat TDP#5 Aldo Paraboni Q/V-band Payload. Concomitant with these measurements are the measurements of drop size distribution and rain rate utilizing a Thies Clima laser precipitation monitor (disdrometer). In this paper, we discuss the comparison of the predicted rain attenuation at 20 and 40 GHz derived from the drop size distribution data with the measured rain attenuation. The results are compared on statistical and real-time bases. We will investigate the performance of the rain attenuation model, instantaneous frequency scaling, and the distribution of the scaling factor. Further, seasonal rain characteristics will be analysed.

millimeter wave↗

Optical Communication Link Atmospheric Attenuation Model

The Space Communications and Navigation (SCaN) Center for Networking, Integration, and Communications (SCENIC) user interface, which provides web accessible space mission simulation and communication system analysis capabilities using verified and validated analysis algorithms, can execute analyses including, but not limited to, line-of-sight, orbit propagation, and dynamic link budget calculations between sets of missions and/or assets. SCENIC's purpose is to provide NASA civil servants and contractors a user-friendly tool, integrated with model data, that can simulate and analyze a range of space mission architectures without the need for repeated and redundant modeling. Given the abundance and further future development of free space optical (FSO) communication channels within modern space infrastructure, the availability of a reliable optical link analysis capability is crucial for SCENIC users. The efforts outlined in this paper aim to provide a model for atmospheric attenuation of FSO communication links, both due to absorption/scattering and turbulence, to increase the accuracy of SCENIC's optical link assessment capabilities. A previous model existed for optical absorption/scattering within the SCaN Link Budget Tool, but it was not location specific for the Earth ground-based nodes, nor was the model optimized for run-time. The new model utilizes years of National Oceanic and Atmospheric Administration (NOAA) visibility data from ground station locations around the world. Visibility, along with the wavelength of the optical signal, are input parameters to calculate the optical specific attenuation, which is a parameter in the calculation of the slant-path attenuation. A final FSO atmospheric attenuation value is comprised of the absorption/scattering attenuation and the turbulence attenuation. A run-time efficient algorithm for the model was then developed and programmed in MATLAB ® . Due to the simple model and vectorization possible in MATLAB, the algorithm has an average run-time of less than one fourth of the run-time of the previous implementation.

Jack L Green↗

Spectral attenuation coefficients from measurements of light transmission in bare ice on the Greenland Ice Sheet

Light transmission into bare glacial ice affects surface energy balance, biophotochemistry, and light detection and ranging (lidar) laser elevation measurements but has not previously been reported for the Greenland Ice Sheet. We present measurements of spectral transmittance at 350–900 nm in bare glacial ice collected at a field site in the western Greenland ablation zone (67.15∘ N, 50.02∘ W). Empirical irradiance attenuation coefficients at 350–750 nm are ∼ 0.9–8.0 m−1 for ice at 12–124 cm depth. The absorption minimum is at ∼ 390–397 nm, in agreement with snow transmission measurements in Antarctica and optical mapping of deep ice at the South Pole. From 350–530 nm, our empirical attenuation coefficients are nearly 1 order of magnitude larger than theoretical values for optically pure ice. The estimated absorption coefficient at 400 nm suggests the ice volume contained a light-absorbing particle concentration equivalent to ∼ 1–2 parts per billion (ppb) of black carbon, which is similar to pre-industrial values found in remote polar snow. The equivalent mineral dust concentration is ∼ 300–600 ppb, which is similar to values for Northern Hemisphere warm periods with low aeolian activity inferred from ice cores. For a layer of quasi-granular white ice (weathering crust) extending from the surface to ∼ 10 cm depth, attenuation coefficients are 1.5 to 4 times larger than for deeper bubbly ice. Owing to higher attenuation in this layer of near-surface granular ice, optical penetration depth at 532 nm is 14 cm (20 %) lower than asymptotic attenuation lengths for optically pure bubbly ice. In addition to the traditional concept of light scattering on air bubbles, our results imply that the granular near-surface ice microstructure of weathering crust is an important control on radiative transfer in bare ice on the Greenland Ice Sheet ablation zone, and we provide new values of flux attenuation, absorption, and scattering coefficients to support model development and validation.

IceSat-2↗

A finite element simulation of sound attenuation in a finite duct with a peripherally variable liner

Using multimodal analysis, a variational finite element method is presented for analyzing sound attenuation in a three-dimensional finite duct with a peripherally variable liner in the absence of flow. A rectangular element, with cubic shaped functions, is employed. Once a small portion of a peripheral liner is removed, the attenuation rate near the frequency where maximum attenuation occurs drops significantly. The positioning of the liner segments affects the attenuation characteristics of the liner. Effects of the duct termination are important in the low frequency ranges. The main effect of peripheral variation of the liner is a broadening of the attenuation characteristics in the midfrequency range. Because of matrix size limitations of the presently available computer program, the eigenvalue equations should be solved out of core in order to handle realistic sources.

Watson, W. R.↗

A depolarization and attenuation experiment using the COMSTAR and CTS satellites

Monthly statistical data are presented on ground rainfall rate and attenuation of satellite downlinks at 11.7 GHz, 19.04 GHz, and 28.56 GHz and on cross-polarization isolation at 11.7 GHz. Regression equations for relating isolation to attenuation, attenuation to rain rate, and attenuation at one frequency to attenuation at another frequency are also included. Longer-term statistics are also presented and discussed.

Bostian, C. W.↗

Measurements of earth-space attenuation at 230 GHz

Measurements of attenuation at 230 GHz through the total atmosphere due to the presence of oxygen and water vapor molecules, clouds, and rain are presented. The measurements were carried out using a specially designed superheterodyne receiver mounted on a sun tracker. Simultaneous measurements were also carried out at 13 GHz. For a measuring site close to sea level at Holmdel, NJ, the 'clear-sky' zenith attenuation was found as a function of the measured ground water vapor density. When the ground temperature was below about 7 C, most cloud and overcast gave less than 0.5-dB attenuation, whereas with a ground temperature greater than 13 C, cloud attenuation was 8-10 times greater. Calculations of zenith attenuation in the 230-GHz atmospheric window were also made using the Gross analytic line shape, Schulze-Tolbert empirical line shape, and an empirically modified Gross line shape. These calculations were based on determinations of water vapor density and temperature made at the measurement site, and on radiosonde measurements made at a distance of 80 km away.

Wrixon, G. T.↗

Wake Vortex Attenuation Flight Tests: A Status Report

Flight tests were conducted to evaluate the magnitude of aerodynamic attenuation of the wake vortices of large transport aircraft that can be achieved through the use of static spoiler deflection and lateral control oscillation. These methods of attenuation were tested on Boeing B-747 and Lockheed L-1011 commercial transport aircraft. Evaluations were made using probe aircraft, photographic and visual observations, and ground based measurements of the vortex velocity profiles. The magnitude of attenuation resulting from static spoiler deflection was evaluated both in and out of ground effect. A remotely piloted QF-86 drone aircraft was used to probe the attenuated vortices in flight in and out of ground effect, and to make landings behind an attenuated B-747 airplane at reduced separation distances.

Barber, Marvin R.↗

Lateral Attenuation of High-By-Pass Ratio Engined Aircraft Noise

A flight experiment was conducted to investigate the lateral attenuation of high by pass ratio engined airplanes. A B-747 was flown at low altitudes over the ends of two microphone arrays. One array covering a lateral distance of 1600 m consisted of 14 microphones positioned over grass. The second array covered a lateral distance of 1200 m and consisted of 6 microphones positioned over a concrete runway. Sixteen runs were flown at altitudes ranging from 30 to 960 m. The acoustic information recorded in the field was reduced to one third octave band spectral time histories and synchronized with tracking and weather information. Lateral attenuation as a function of elevation angle was calculated in overall, A-weighted, tone-corrected perceived noise level, and effective perceived noise level units. The B-747 results are compared with similar results for a turbojet-powered T-38 airplane and the SAE recommended lateral attenuation prediction procedure. Less lateral attenuation was measured for the B-747 than for the T-38. The B-747 lateral attenuation values also fell below the SAE curve.

Willshire, W. L., Jr.↗

Effect of particle size distribution and chlorophyll content on beam attenuation spectra

The relationships between beam attenuation spectra, chlorophyll and pheophytin pigment concentrations, and particle size distributions are examined for a coastal region believed to have negligible concentrations of terrestrially derived dissolved organic compounds but large quantities of phytoplankton and resuspended sediments. It was found that the slope of the beam attenuation spectra increases when the hyperbolic slope of the size distribution increases. The magnitude of this increase in slope was consistent with calculations based on a range of particle diameters from 0.5 to 30 microns so that it would be possible to predict the slope of the particle size distribution if the slope of the beam attenuation spectra is known. The ratio of chlorophyll and pheophytin pigments to suspended volume concentrations affected the beam attenuation spectra to a lesser degree and in a more complex manner. Because of the strong effect of slope, it was concluded that the chlorophyll and pheophytin pigment content of suspended particles could not be efficiently predicted by means of beam attenuation measurements.

Kitchen, J. C.↗

A two-component rain model for the prediction of attenuation statistics

A two-component rain model has been developed for calculating attenuation statistics. In contrast to most other attenuation prediction models, the two-component model calculates the occurrence probability for volume cells or debris attenuation events. The model performed significantly better than the International Radio Consultative Committee model when used for predictions on earth-satellite paths. It is expected that the model will have applications in modeling the joint statistics required for space diversity system design, the statistics of interference due to rain scatter at attenuating frequencies, and the duration statistics for attenuation events.

Crane, R. K.↗

A statistical rain attenuation prediction model with application to the advanced communication technology satellite project. 1: Theoretical development and application to yearly predictions for selected cities in the United States

A rain attenuation prediction model is described for use in calculating satellite communication link availability for any specific location in the world that is characterized by an extended record of rainfall. Such a formalism is necessary for the accurate assessment of such availability predictions in the case of the small user-terminal concept of the Advanced Communication Technology Satellite (ACTS) Project. The model employs the theory of extreme value statistics to generate the necessary statistical rainrate parameters from rain data in the form compiled by the National Weather Service. These location dependent rain statistics are then applied to a rain attenuation model to obtain a yearly prediction of the occurrence of attenuation on any satellite link at that location. The predictions of this model are compared to those of the Crane Two-Component Rain Model and some empirical data and found to be very good. The model is then used to calculate rain attenuation statistics at 59 locations in the United States (including Alaska and Hawaii) for the 20 GHz downlinks and 30 GHz uplinks of the proposed ACTS system. The flexibility of this modeling formalism is such that it allows a complete and unified treatment of the temporal aspects of rain attenuation that leads to the design of an optimum stochastic power control algorithm, the purpose of which is to efficiently counter such rain fades on a satellite link.

Manning, Robert M.↗

The effect of temperature on attenuation-correction schemes in rain using polarization propagation differential phase shift

The study elucidates and quantifies differences in the response of the rate of change of polarization propagation differential phase shift Phi, the rate of attenuation for a horizontally/vertically polarized wave A(H,V), and the rate of polarization differential attenuation A(H-V) to temperature. It is shown that if the effects of temperature when estimating A(H) and A(H-V) from Phi are neglected, the average fractional standard error increases only slightly at 9 GHz but significantly at 5 and 3 GHz. Errors at 5 and 3 GHz are about two to three times those at 9 GHz. The performance of Phi-based schemes of attenuation correction at these lower frequencies is much more significantly degraded by temperature uncertainty than at 9 GHz. It is concluded that it is best to use Phi to correct for attenuation at the least-attenuating frequencies.

Jameson, A. R.↗

Radar Observation of Large Attenuation in Convective Storms: Implications for the Dropsize Distribution

Airborne meteorological radars typically operate at attenuating wavelengths. The path integrated attenuation (PIA) can be estimated using the surface reference technique (SRT). In this method, an initial value is determined for the radar cross section of the earth surface in a rain-free area in relatively close proximity to the rain cloud. During subsequent observations of precipitation any decrease 'in the observed surface cross section from the reference value s assumed to be a result of the two-way attenuation along the propagation path. In this paper we present selected instances of high PIA observed over land by an airborne radar. The observations were taken in Brazil and Florida during TRMM (Tropical Rainfall Measurement Mission) field campaigns. We compared these observations with collocated and nearly simultaneous ground-based radar observations by an S-band radar that is not subject to significant attenuation. In this preliminary evaluation, a systematic difference in the attenuation in the two storms is attributed to a difference in the raindrop size distributions; this is supported by observations of ZDR (differential reflectivity).

Tian, Lin↗

Attenuation of Gas Turbulence by a Nearly Stationary Dispersion of Fine Particles

Turbulence attenuation by greater than a factor of two has been observed in many practical gas flows carrying volume fractions as small as 0.01% of dispersed particles. Particles which cause such attenuation usually are smaller than the smallest scales of the turbulence and have time constants 5 to 10 times greater than the time scale of a typical turbulent eddy. That is, strongly attenuating particles usually have Stokes numbers in the range of 5 to 10, indicating that they do not respond to the turbulent fluctuations, but instead just fall through the flow responding only to the mean flow. There are two mechanisms by which free falling particles may attenuate turbulence. First, the unresponsive particles act as a drag on the turbulent eddies, passing energy from the turbulent eddies to the small scale wakes of the particles where it is quickly dissipated by viscosity. The second mechanism is more complicated. Particles falling under gravity convert gravitational potential energy to turbulent velocity fluctuations. If the particles are large, this mechanism increases the overall turbulence level. However, with moderate size particles, the small scale turbulence generated apparently distorts the turbulent eddies leading to more rapid dissipation. Unfortunately, this conclusion is supported only by circumstantial evidence to date. The objectives of the experiment are to use microgravity to separate the two mechanisms. A region of nearly-isotropic decaying turbulence with zero mean flow will be formed in a box in the microgravity environment. Different sets of particles with Stokes numbers in the range of 2 to 20 will be dispersed in the flow. With zero gravity and no mean fluid velocity the particles will have zero mean velocity. With the large Stokes numbers, the fluctuating velocities will also be small. Therefore, the only attenuation mechanism will be the direct action of the particles on the turbulence. Control experiments will also be done in which the particles fall through the measurement volume. Measurements will be acquired using a high resolution image velocimetry (PIV) system being developed specifically for work in particle-laden flows. The measurements will include the decay of the turbulence kinetic energy under various particle loadings. The spatial spectra of the turbulence will also be measured. In a second set of experiments, the interaction of a single eddy with a collection of nearly stationary particles will be examined. The eddy will be a vortex ring emitted by a jet pulse through an orifice. The distortion of the vortex under the influence of the particles will be examined to gain a better understanding of how fine particles can cause such large reductions in turbulence levels. This experiment could not be conducted in terrestrial gravity because the high particle velocities would overwhelm the relatively low speed motion of the vortex ring. This experimental program is just getting underway. The initial challenge is to build a closed facility containing reasonably homogeneous and isotropic turbulence with zero mean velocity. Our approach is to use a set of synthetic jets mounted on the periphery of a transparent plexiglass box to create the turbulence. A synthetic jet is a plenum chamber with an orifice open to the volume of interest. The volume of the chamber fluctuates periodically so alternately a jet is ejected from the volume or flow is drawn back in as a sink. The asymmetry of this situation results in a net transport of momentum and kinetic energy into the volume of interest. The present apparatus includes eight synthetic jets each powered independently by a six inch loudspeaker. The synthetic jets discharge through ejector tubes to increase the scale of the turbulence. Construction of the apparatus is now complete and preliminary flow visualization studies have been conducted. The PIV system is also under development. A compact dual-pulse YAG laser has been acquired as the light source and special software is under development to allow simultaneous measurements of both the particle phase and the fluid phase (marked by fine tracers).

Paris, A. D.↗