Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Chromium(VI) Bioremoval by Pseudomonas Bacteria: Role of Microbial Exudates for Natural Attenuation and Biotreatment of Cr(VI) Contamination

Laboratory batch and column experiments were conducted to investigate the role of microbial exudates, e.g., exopolymeric substance (EPS) and alginic acid, on microbial Cr(VI) reduction by two different Pseudomonas strains (P. putida P18 and P. aeuroginosa P16) as a method for treating subsurface environment contaminated with Cr(VI). Our results indicate that microbial exudates significantly enhanced microbial Cr(VI) reduction rates by forming less toxic and highly soluble organo-Cr(III) complexes despite the fact Cr(III) has a very low solubility under the experimental conditions studied (e.g., pH 7). The formation of soluble organo-Cr(III) complexes led to the protection of the cells and chromate reductases from inactivation. In systems with no organic ligands, soluble organo-Cr(III) end products were formed between Cr(III) and the EPS directly released by bacteria due to cell lysis. Our results also provide evidence that cell lysis played an important role in microbial Cr(VI) reduction by Pseudomonas bacteria due to the release of constitutive reductases that intracellularly and/or extracellularly catalyzed the reduction of Cr(VI) to Cr(III). The overall results highlight the need for incorporation of the release and formation of organo-Cr(III) complexes into reactive transport models to more accurately design and monitor in situ microbial remediation techniques for the treatment of subsurface systems contaminated with Cr(VI).

59 BASIC BIOLOGICAL SCIENCES↗

Uranium Attenuated by a Wetland 50 Years after Release into a Stream

: Wetlands have several important roles in the hydrological cycle, including maintaining water quality by removing surface and groundwater contaminants. Over time, the wetlands themselves can become contaminated, posing a secondary environmental threat. The objective of this study was to calculate the inventory of uranium (U) remaining in a wetland 50 years after the Fuel Fabrication Facility on the Savannah River Site located in South Carolina released 43.5 Mg of U into the nearby environment. Over 232 700 gamma spectra and their associated global positioning system (GPS) coordinates were collected and collated into a map of the contaminated land area. Five core samples were also collected that contained U concentrations as high as 14 099 mg/kg (background levels are about 2.7 mg/kg U). The contaminated area was 278 000 m2 , and it contained 36.2 Mg U, about 83% of the U released. About 80% of the U in the wetland was concentrated in a former beaver pond, a 73 000 m2 area (26% of the contaminated area). This contaminated wetland area was almost 2 km from the source, indicating that it comprised unique hydro-biogeochemical properties for immobilizing the released U. To the best of our knowledge, this is the first data-rich study to quantify the long-term effectiveness of a wetland to immobilize inorganic contaminants. Significant environmental changes to the system, such as those associated with hydrology, forest fires, or anthropogenic land use, may alter the complex hydro-biogeochemical interactions necessary for the long-term immobilization of the U.

Contaminant inventory↗

The Relationship Between Experimental Geometry Heat Rate and Ultrasound Wave Speed Measurement While Observing Phase Changes in Highly Attenuative Materials

Ultrasound techniques are capable of monitoring changes in the time-of-flight as a material is exposed to different thermal environments. The focus of the present study is to identify the phase of a material via ultrasound compression wave measurements in a through transmission experimental setup as the material is heated from a solid to a liquid and then allowed to re-solidify. The present work seeks to expand upon the authors’ previous research, which proved this through transmission phase monitoring technique was possible, by considering different experimental geometries. The relationship between geometry, the measured speed of sound, and the temperature profile is presented. The use of different volumes helps in establishing a baseline understanding of which aspects of the experiment are geometry dependent and which are independent. The present study also investigates the relationship between the heating rate observed in the experiment and the measured speed of sound. Lastly, the trends identified between the experimental geometry, heat rate and ultrasound wave speed measurement assist in providing a baseline understanding of the applicability of this technique to various industries, including the polymer industry and the oil industry.

36 MATERIALS SCIENCE↗

ER retention is imposed by COPII protein sorting and attenuated by 4-phenylbutyrate

Native cargo proteins exit the endoplasmic reticulum (ER) in COPII-coated vesicles, whereas resident and misfolded proteins are substantially excluded from vesicles by a retention mechanism that remains unresolved. We probed the ER retention process using the proteostasis regulator 4-phenylbutyrate (4-PBA), which we show targets COPII protein to reduce the stringency of retention. 4-PBA competes with p24 proteins to bind COPII. When p24 protein uptake is blocked, COPII vesicles package resident proteins and an ER-trapped mutant LDL receptor. We further show that 4-PBA triggers the secretion of a KDEL-tagged luminal resident, implying that a compromised retention mechanism causes saturation of the KDEL retrieval system. The results indicate that stringent ER retention requires the COPII coat machinery to actively sort biosynthetic cargo from diffusible misfolded and resident ER proteins.

60 APPLIED LIFE SCIENCES↗

Control algorithms for dynamic attenuators

Purpose: The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. Methods: The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not requirea priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. Results: The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Conclusions: Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

The need for multicomponent dust attenuation in modeling nebular emission: Constraints from SDSS-IV MaNGA

A fundamental assumption adopted in nearly every extragalactic study that analyzes optical emission lines is that the attenuation of different emission lines can be described by a single attenuation curve, scaled by a single reddening parameter, usually E(B - V). Here we show this assumption fails in many cases with important implications for derived results. We developed a new method to measure the differential nebular attenuation among three kinds of transitions: the Balmer lines of hydrogen; high-ionization transitions (> 13.6 eV) including [Ne III], [O III], and [S III]; and low-ionization transitions (≲13.6 eV) including [O II], [N II], and [S II]. This method bins the observed data in a multidimensional space spanned by attenuation-insensitive line ratios. Within each small bin, the variations in nebular parameters such as the metallicity and ionization parameter are negligible compared to the variation in the nebular attenuation. This allowed us to measure the nebular attenuation using both forbidden lines and Balmer lines. We applied this method to a sample of 2.4 million star-forming (SF) spaxels from the Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. We found that the attenuation of high ionization lines and Balmer lines can be well described by a single Fitzpatrick (1999, PASP, 111, 63) extinction curve with R V = 3.1. However, no single attenuation curve can simultaneously account for these transitions and the derived attenuation of low-ionization lines. This strongly suggests that different lines have different effective attenuations, likely because spectroscopy at hundreds of parsecs to kiloparsecs of resolution mixes multiple physical regions that exhibit different intrinsic line ratios and different levels of attenuation. As a result, the assumption that different lines follow the same attenuation curve breaks down. Using a single attenuation curve determined by Balmer lines to correct attenuation-sensitive forbidden line ratios could bias the nebular parameters derived by 0.06–0.25 dex at A V = 1, depending on the details of the dust attenuation model. Observations of a statistically large sample of H II regions with high spatial resolutions and large spectral coverage are vital for improved modeling and deriving accurate corrections for this effect.

79 ASTRONOMY AND ASTROPHYSICS↗

AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

14 SOLAR ENERGY↗

Measurements of attenuation and scattering properties of water-based liquid scintillator

Water-based liquid scintillator (WbLS) is a hybrid detector medium which has been proposed as a fill material for future large-volume rare event searches, including ν − detectors. This family of scintillating suspensions promises waterlike attenuation and scattering behavior, while offering scintillation light yield for sub-Cherenkov-threshold events. These features may allow for improved vertex and energy resolution, and concomitant improvements in background rejection and particle identification. While subscale measurements of light yield, timing and pulse-shape have been performed in several WbLS formulations, detailed measurements of the attenuation and scattering properties of WbLS remain a critical, unresolved step along the pathway to deployment. In pursuit of a better understanding of these parameters, a “long-arm” attenuation and scattering instrument has been developed at Lawrence Livermore National Laboratory, dubbed LASE (Livermore Attenuation and Scattering Experiment). Optical property measurements have been performed using LASE in DI water, Gd-water, WbLS and Gd-WbLS. Measurements of the optical properties of WbLS (1% LAB-PPO scintillator) provided by Brookhaven National Laboratory demonstrate an attenuation minimum of 4.87 × 10 − 4 ± 1.42 × 10 − 4 cm − 1 at 450 nm, while Gd-loaded WbLS (1% LAB-PPO scintillator, 0.1% Gd) demonstrated a minimum attenuation coefficient of 4.77 × 10 − 4 ± 1.27 × 10 − 4 cm − 1 at the same wavelength. Measurements of scattering in WbLS show a scattering coefficient of 3.39 × 10 − 4 ± 1.98 × 10 − 5 cm − 1 at the 450 nm attenuation minimum, while Gd-WbLS has a scattering coefficient of 2.8 × 10 − 4 ± 1.63 × 10 − 5 cm − 1 at that wavelength. These scattering and attenuation coefficients are significantly larger than measured for DI water at similar wavelengths ( 8.8 × 10 − 5 cm − 1 ± 3.8 × 10 − 5 attenuation at 430 nm, 2.2 × 10 − 5 ± 1.28 × 10 − 6 cm − 1 scattering). Though the WbLS attenuation and scattering coefficients measured are lower than the corresponding values published for ultrapure oils and LAB-PPO liquid scintillator, the material tested attenuates significantly more than water across the blue and green portions of the visible spectrum. This attenuation is markedly stronger at wavelengths under 430 nm. Published by the American Physical Society 2025

47 OTHER INSTRUMENTATION↗

Determination of attenuation coefficients of heavyweight concretes containing colemanite by using {sup 133}Ba radioactive isotope source - Paper 140

As it is well known, colemanite is a boron ore. Boron is one of the most important underground richness of Turkey. Boron is employed as a constituent material of neutron shielding because of its high absorption of thermal neutrons. Barite ore includes BaSO{sub 4}, which is a well photon radiation absorbent. The literature about radiation attenuation in heavy concretes (including boron and barite ores) is fairly abundant. Abdo and Abdo et al. theoretically calculated and determined cross section by using XCOM computer program for photon and neutron radiations shielding. Akkurt et al. measured radiation transmission of heavy concretes including normal and barite aggregates for different γ-ray energies and calculated linear attenuation coefficients. Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite as control absorber in nuclear reactors γ-rays and neutron particles shielding. Bashter and Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite, basalt-magnetite, ilmenite, basalt, steel and magnetite for only photon radiation shielding and calculated linear and mass attenuation coefficients from 10 keV to 1 GeV. Dealmeid et al. studied radiation transmission and angular distribution for 25 MV X-rays by using LINAC. Demir and Keles measured radiation transmission of concrete including boron waste for 59.54 and 80.99 keV γ-rays. Kaplan reported about many heavy concretes studies in his book. Kitis et al. studied heavy concretes including barite aggregates for cyclotron shielding. Mollah et al. determined concretes including ilmenite and magnetite aggregates for neutron shielding by using {sup 252}Cf radioactive source and BF{sub 3} neutron detector. Yarar and Bayuelken studied concretes including colemanite aggregates for neutron shielding. In this paper, we have measured radiation transmission of thirteen different heavy concretes produced by using barite, colemanite and normal aggregates for 276, 303, 356 and 383 keV γ-ray energies of {sup 133}Ba radioactive isotope by using CdTe semiconductor detector and calculated linear and mass attenuation coefficients. Results were compared to X-ray mass attenuation coefficient values of NIST. The attenuation of γ-ray photons is governed primarily by the atomic number and density of the concrete as a shielding material. Photon attenuation depends on pair production, photoelectric effect and Compton scattering. In this study, linear attenuation coefficients (μ) decrease with the increasing the photon energy for these concretes. Heavy elements there is a fairly sharp minimum in the absorption cross section at about this energy region. It is indicated that attenuation coefficient is useful parameter for radiation shielding. As known, the linear attenuation coefficients of the concretes used in this study at these γ-ray energies are not available in the literature by using CdTe semiconductor detectors. The data shows the effects of including boron-rich colemanite or barium-rich barite in addition to normal aggregate in the concrete mixtures. As would be expected, the barite is desirable for photon attenuation, while the colemanite is desirable for neutron attenuation. The concretes including barite and colemanite would be preferred as materials for building construction of radiation oncology departments, radiology departments, nuclear reactors and radiation research laboratories against photon and neutron particle radiations. But other aggregate properties of colemanite such as abrasion resistance and freeze-thaw durability are also found to be important for concrete but they cannot be quantified at this study. (authors)

36 MATERIALS SCIENCE↗

SU-G-IeP4-02: Application of Changs Attenuation Correction Technique for SPECT Partial Angle Acquisition of Jaszczak Phantom

Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (n = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.

60 APPLIED LIFE SCIENCES↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗