Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuation correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. Here, we also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.

58 GEOSCIENCES↗

Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene

We discuss using a series of detector measurements taken at different locations to localize a source of radiation as a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interpolated Sounding and Gridded Sounding Value-Added Products

Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25 and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.

54 ENVIRONMENTAL SCIENCES↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction Π will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥Π∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, Π may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥Π∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

A large, deep 3 deg2 survey of H α, [O iii ], and [O ii ] emitters from LAGER: constraining luminosity functions

ABSTRACT We present our measurements of the H α, [O iii], and [O ii] luminosity functions as part of the Lyman Alpha Galaxies at Epoch of Reionization (LAGER) survey using our samples of 1577 z = 0.47 H α-, 3933 z = 0.93 [O iii]-, and 5367 z = 1.59 [O ii]-selected emission line galaxies in a 3 deg2 single, CTIO/Blanco DECam pointing of the COSMOS field. Our observations reach 5σ depths of 8.2 × 10−18 erg s−1 cm−2 and comoving volumes of (1−7) × 105 Mpc3 making our survey one of the deepest narrow-band surveys. We select our emission line galaxies via spectroscopic confirmation, photometric redshifts, and colour–colour selections. We measure the observed luminosity functions for each sample and find best fits of $\phi ^\star = 10^{-3.16^{+0.09}_{-0.09}}$ Mpc−3 and $L^\star = 10^{41.72^{+0.09}_{-0.09}}$ erg s−1 for H α, $\phi ^\star = 10^{-2.16^{+0.10}_{-0.12}}$ Mpc−3 and $L^\star = 10^{41.38^{+0.07}_{-0.06}}$ erg s−1 for [O iii], and $\phi ^\star = 10^{-1.97^{+0.07}_{-0.07}}$ Mpc−3 and $L^\star = 10^{41.66^{+0.03}_{-0.03}}$ erg s−1 for [O ii], with α fixed to −1.75, −1.6, and −1.3, respectively. An excess of bright >1042 erg s−1 [O iii] emitters is observed and may be due to active galactic nucleus (AGN) contamination. Corrections for dust attenuation are applied assuming AHα = 1 mag. We also design our own empirical rest-frame g − r calibration using SDSS DR12 data, test it against our z = 0.47 H α emitters with zCOSMOS 1D spectra, and calibrate it for (g − r) between −0.8 and 1.3 mag. Dust and AGN-corrected star formation rate densities (SFRDs) are measured as log10ρSFR/(M⊙ yr−1 Mpc−3) = −1.63 ± 0.04, −1.07 ± 0.06, and −0.90 ± 0.10 for H α, [O iii], and [O ii], respectively. We find our [O iii] and [O ii] samples fully trace cosmic star formation activity at their respective redshifts in comparison to multiwavelength SFRDs, while the H α sample traces ∼70 per cent of the total z = 0.47 SFRD.

Khostovan, A. A.↗

Multiphenomenology explosion monitoring (MultiPEM): a general framework for data interpretation and yield estimation

SUMMARY An underground nuclear explosion (UNE) couples mechanical energy into crustal rock, which propagates as seismic and acoustic waves. These different physical phenomena transport, by different pathways, to standoff detectors at varying distances. The transport pathways attenuate the original signal but in different ways. Enabled by correct statistical weighting, signal attenuation models can be used to combine these disparate sensor data to estimate the yield of an UNE. Contemporaneous statistical models, used in yield estimation, can be improved with an advanced partition of error for these physical signal propagation models. We present an advanced multivariate approach to error modelling of multiphenomenology physical signatures. In addition to measurement error, our error model represents physical model biases as random with a physics-based covariance structure. To illustrate this proposed framework, we demonstrate the estimation of explosion yield using openly available seismic and acoustic data from chemical single-point explosions.

Williams, Brian J.↗

CSAPR2 cell-tracking data collected during TRACER

One of the challenges of analyzing convective cell properties is quick evolution of the individual convective cells. While the operational radar data provide great a data set to analyze the evolution of radar observables of convective precipitation clouds statistically, previous studies also suggested that, because of the quick evolution of cell life cycle, conventional radar volume scan strategies taking ~5-7 minutes might not capture the detailed evolution. The TRACER campaign deployed CSAPR2, which performed frequent update of RHI and sector PPI scans to track convective cells every < 2 minutes guided by a new cell-tracking framework, Multisensor Agile Adaptive Sampling (MAAS; Kollias et al. 2020). This allows for capturing fast-evolving radar observables. The submitted data files are CSAPR2 data in CfRadial format collected during the TRACER field campaign from June to September 2020. The data files include processed radar variables including: noise-masked reflectivity and differential reflectivity corrected for rain attenuation and systematic biases, noise-masked dealiased radial velocity, specific differential phase, locations of target cells (latitude, longitude, radar range), and radar-echo classification.

54 ENVIRONMENTAL SCIENCES↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CSAPR2 Optimized Convective Cell Tracking Data during TRACER

One of the challenges in analyzing convective cell properties is to observe the quick evolution of individual convective cells. While the operational radar data provide a volumetric data set to analyze radar observables of convective precipitation clouds, previous studies also suggested the quick evolution of cell life cycle that might not be captured by conventional radar volume scan strategies that take ~5-7 minutes. Aiming at enhancing our understanding of the links between convective cloud kinematic and microphysical processes as well as life cycles, the Tracking Aerosol Convection Interactions ExpeRiment (TRACER; Jensen et al. 2019) was conducted at Houston, Texas, in 2022. The TRACER campaign deployed the 2nd generation C-band Scanning ARM Precipitation Radar (CSAPR2), which performed frequent updates of range height indicator (RHI) and sector plan position indicator (PPI) scans to track individual convective cells every < 2 minutes, guided by a new cell tracking framework, Multisensor Agile Adaptive Sampling (MAAS; Kollias et al. 2020). This allows for capturing fast-evolving radar observables. We provide the processed CSAPR2 cell tracking data in CfRadial format collected during the TRACER field campaign from June to September 2022. The data files include processed radar variables: noise-masked reflectivity and differential reflectivity corrected for rain attenuation and systematic biases, noise-masked dealiased radial velocity, specific differential phase, locations of target cells (latitude, longitude, radar range), and radar-echo classification. Figure 1 provides an example of a 3D image of CSAPR2 reflectivity from the lowest PPI scan and an RHI scan after data processing.

54 ENVIRONMENTAL SCIENCES↗

CSAPR2 CMAC 2.0 level c1 data.

Raw data from ARM precipitation radars must be corrected for atmospheric phenomena and instrument characteristics (e.g., attenuation, clutter) to retrieve precipitation properties. The Corrected Moments in Antenna Coordinates Version 2 (CMAC2) value-added product (VAP) is a set of algorithms and code that does such corrections, and it also retrieves precipitation quantities from the radar measurements. Similar to the X-SAPR radars at the ARM main site, C-SAPR2 radar data also needs corrections and improvements. CMAC 2.0 has been updated to work with the ARM C-SAPR 2 radar. Data and fields that have been processed to: correct for velocity aliasing, unfold and generate a cross-polarimetric phase difference that is monotonically increasing, removing impulses caused by non-uniform beam filling and phase shift on backscatter, recalculate specific differential phase using a 20-point Sobel filter on the aforementioned phase, correct for liquid path attenuation using the polarimetric signals, estimate rainfall rates at the gate using the specific attenuation. In addition, CMAC writes the data out into a community-standard format netCDF File using the CF/Radial conventions. The data are therefore compatible with new and existing National Center for Atmospheric Research (NCAR) tools such as RadXConvert for converting to a variety of popular file formats.

54 ENVIRONMENTAL SCIENCES↗

Misclassification of primary liver cancer in the Life Span Study of atomic bomb survivors

Primary liver cancer is difficult to diagnose accurately at death, due to metastases from nearby organs and to concomitant diseases, such as chronic hepatitis and cirrhosis. Trends in diagnostic accuracy could affect radiation risk estimates for incident liver cancer by altering background rates or by impacting risk modification by sex and age. We quantified the potential impact of death‐certificate inaccuracies on radiation risk estimates for liver cancer in the Life Span Study of atomic bomb survivors. True‐positive and false‐negative rates were obtained from a previous study that compared death‐certificate causes of death with those based on pathological review, from 1958 to 1987. We assumed various scenarios for misclassification rates after 1987. We obtained estimated true positives and estimated false negatives by stratified sampling from binomial distributions with probabilities given by the true‐positive and false‐negative rates, respectively. Poisson regression methods were applied to highly stratified person‐year tables of corrected case counts and accrued person years. During the study period (1958–2009), there were 1,885 cases of liver cancer, which included 383 death‐certificate‐only (DCO) cases; 1,283 cases with chronic liver disease as the underlying cause of death; and 150 DCO cases of pancreatic cancer among 105,444 study participants. Across the range of scenarios considered, radiation risk estimates based on corrected case counts were attenuated, on average, by 13–30%. Our results indicated that radiation risk estimates for liver cancer were potentially sensitive to death‐certificate inaccuracies. Additional data are needed to inform misclassification rates in recent years.

French, Benjamin↗

KAZRCORGE

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcorge.c1 (ge=general sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity.

54 ENVIRONMENTAL SCIENCES↗

KAZRCORMD

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcormd.c1 (md=moderate sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity.

54 ENVIRONMENTAL SCIENCES↗

KAZRCORHI

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcorhi.c1 (hi=high sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity.

54 ENVIRONMENTAL SCIENCES↗

KAZRCORGE-c0

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcorge.c1 (ge=general sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity. Note that reflectivity in this product is not calibrated.

54 ENVIRONMENTAL SCIENCES↗

KAZRCORHI-c0

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcorhi.c1 (hi=high sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity. Note that reflectivity in this product is not calibrated.

54 ENVIRONMENTAL SCIENCES↗

KAZRCORMD-c0

For the Ka ARM Zenith Radar (KAZR) data stream, kazrcorge.c1 (ge=general sensitivity), produces significant detection mask, corrects reflectivity for gaseous attenuation, and dealiases mean Doppler velocity. Note that reflectivity in this product is not calibrated.

54 ENVIRONMENTAL SCIENCES↗