Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atom probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Geochemical Quantification of Olivine Minerals by Atom Probe Tomography

The ability of atom probe tomography (APT) to interrogate small sample volumes with high efficiency makes it uniquely useful in the study of small mineral grains or domains. Although it is frequently employed in the analysis of geological materials, particularly in the characterization of nanoscale chemical heterogeneities, the degree of quantitative accuracy achieved by APT can be difficult to determine.

D W Saxey↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

Development of Operando Atom Probe to study field-assisted surface chemistry

Recent efforts at PNNL have led to the development of in-situ Atom Probe Tomography (ISAPT) and Operando Atom Probe (OAP), establishing PNNL as a key player in this technology, both in the U.S. and globally. OAP has already pushed the initial limits of APT, which was traditionally used at cryo temperatures (<60 K) and ultra-high vacuum (<10⁻¹² bar), to operate in the presence of reactive gases (up to 10⁻¹⁰ bar) at a maximum temperature of 300 K. Using OAP, we successfully observed Co and Fe oxidation in real-time at the nanoscale, revealing the importance of surface structures in these interactions. Additionally, OAP opens the possibility to explore the influence of local electric fields (EFs) on surface chemistry and hydrogen interactions at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Perspectives of Metal Degradation via In Situ Atom Probe Tomography

Abstract We report a unique in situ instrument development effort dedicated to studying gas/solid interactions relevant to heterogeneous catalysis and early stages of oxidation of materials via atom probe tomography and microscopy (APM). An in situ reactor cell, similar in concept to other reports, has been developed to expose nanoscale volumes of material to reactive gas environments, in which temperature, pressure, and gas chemistry are well controlled. We demonstrate that the combination of this reactor cell with APM techniques can aid in building a better mechanistic understanding of resultant composition and surface and subsurface structure changes accompanying gas/surface reactions in metal and metal alloy systems through a series of case studies: O 2 /Rh, O 2 /Co, and O 2 /Zircaloy-4. In addition, the basis of a novel operando mode of analysis within an atom probe instrument is also reported. The work presented here supports the implementation of APM techniques dedicated to atomic to near-atomically resolved gas/surface interaction studies of materials broadly relevant to heterogeneous catalysis and oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Segmentation in Atom-Probe Tomography Using Deep Learning-Based Edge Detection

Abstract Atom-probe tomography (APT) facilitates nano- and atomic-scale characterization and analysis of microstructural features. Specifically, APT is well suited to study the interfacial properties of granular or heterophase systems. Traditionally, the identification of the interface between, for precipitate and matrix phases, in APT data has been obtained either by extracting iso-concentration surfaces based on a user-supplied concentration value or by manually perturbing the concentration value until the iso-concentration surface qualitatively matches the interface. These approaches are subjective, not scalable, and may lead to inconsistencies due to local composition inhomogeneities. We introduce a digital image segmentation approach based on deep neural networks that transfer learned knowledge from natural images to automatically segment the data obtained from APT into different phases. This approach not only provides an efficient way to segment the data and extract interfacial properties but does so without the need for expensive interface labeling for training the segmentation model. We consider here a system with a precipitate phase in a matrix and with three different interface modalities—layered, isolated, and interconnected—that are obtained for different relative geometries of the precipitate phase. We demonstrate the accuracy of our segmentation approach through qualitative visualization of the interfaces, as well as through quantitative comparisons with proximity histograms obtained by using more traditional approaches.

47 OTHER INSTRUMENTATION↗

Alpha Shape Analysis (ASA) Framework for Post- Clustering Property Determination in Atom Probe Tomographic Data

While application of clustering algorithms to atom probe tomography data have enabled quantification of solute clusters in terms of number density, size, and subcomposition there exist other properties (e.g., volume, surface area, and composition) that are better determined by defining an interface between the cluster and the surrounding matrix. The limitation in composition results from an ion selection step where the expected matrix ion types are omitted from the cluster search algorithm to enhance the contrast between the matrix and cluster and to reduce the complexity of the search. Previously, composition determination within solute clusters has utilized a secondary envelopment and erosion step on top of conventional methods such as maximum separation. In this work, we present a novel stochastic method that combines the particle identification fidelity of a conventional clustering algorithm with the analytical flexibility of mesh-based approaches through the generation of alpha shapes for each identified cluster. Furthermore, the corresponding mesh accounts for concave components of the clusters and determines the volume and surface area of the clusters; additionally, the mesh boundary is utilized to update the total composition according to the internal ions.

42 ENGINEERING↗

Nanoscale microstructure and chemistry of transparent gahnite glass-ceramics revealed by atom probe tomography

The nanoscale microstructure and chemistry of a transparent gahnite glass-ceramic and its precursor glass were investigated using atom probe tomography, transmission electron microscopy, and nuclear magnetic resonance spectroscopy. In the annealed precursor glass, statistically significant ZrO clustering was observed along with Si depletion within 2 nm of the ZrO clusters. This clustering is expected to be the first step in the nucleation and crystallization of the nucleating agent, ZrO 2 . In the glass-ceramic, gahnite (ZnAl 2 O 4 ) crystallites were found to exist in proximal locations to ZrO 2 and not in a core-shell arrangement. The residual glass composition was directly measured by atom probe, showing higher concentrations of Al, Zn, and Zr than previously expected. At the interfaces between the crystallites and residual glass, no enrichment or depletion zones were found. Our findings provide answers to outstanding questions surrounding the nucleation and elemental partitioning, microstructure, and the residual glass composition of transparent gahnite glass-ceramics.

36 MATERIALS SCIENCE↗

Quantative Measurements of Trace Elements and Three-Dimensional Atomic Scale Characterisation of Presolar O-rich Oxides and Silicates: An Atom Probe Tomography Approach

Presolar grains are recordsof a single moment in stellar evolution which have survived nebula and parent body processingwithin our Solar System. These grains condensed within a range of stellar envi-ronments including asymptotic giant branch stars, red giant branch stars, nova, supernova (SN) and hydrogen burning electron capture supernova(ECSN)[1,2]. Iso-topic and chemical compositions can be used to unravel details about environmental conditions at the time of their condensation and physical and chemical processes occurring at the time. For example,nucleosynthesis, stellar evolution, physical properties of stellar atmos-pheres, mixing from inner core to outer envelope, galac-tic chemical evolution, interstellar medium and parent body processing.NanoSIMS enables detailed characterisation of iso-topic compositions and rapid in situidentification of O-rich presolar oxides and silicates using their character-istic 17O/16O and 18O/16O isotopic ratios.Spectroscopic techniques e.g., auger spectroscopyand transmission electron microscopy, have provided additional details on major and minor chemical signatures. However, due tospatial resolution limitations,interaction volumes and interferencesfrom surrounding grains for in situtech-niques, attaining quantative characterisation of trace el-ements,hasproved challenging[1,3]. As the most sensitive geochemical tracers of envi-ronmental changes, trace elements are essential to un-ravelling the geochemical record of their parent stellar environments and evolutionary pathways[4].We car-ried out correlated in situisotopic and chemical analyses of 13 presolar grains to better understand stellar evolu-tion. In this work, we achieved this using a custom ap-proach, coordinating NanoSIMS, Scanning Electron Microscopy Energy Dispersive X-Ray Spectroscopy (SEM-EDX)and Atom Probe Tomography(APT).Our objective was to develop an approach which could ena-ble precise targeting of presolar grains for atom probe tomography and successfully execute atomic scale anal-yses of presolar oxides and silicates, to achieve quantative analysis of their trace elements for the first time.We also aimed to test the capability for Atom Probe tomography to measure isotopic compositions and stoichiometries of presolar oxide and silicate grains.

N D Nevill↗

Atom Probe Tomography for the Observation of Hydrogen in Materials: A Review

Atom probe tomography (APT) is an emerging microscopy technique that has high sensitivity for hydrogen with sub-nanometre-scale spatial resolution, which makes it a unique method to investigate the atomic-scale distribution of hydrogen at interfaces and defects in materials. This article introduces the basics of APT-based hydrogen analysis, particularly the challenge of distinguishing a hydrogen background signal in APT by using hydrogen isotopes, along with strategies to yield high-quality analysis. This article also reviews several important findings on hydrogen distribution in a range of materials, including both structural alloys and functional materials, enabled by using APT. Limitations and future opportunities for hydrogen analysis by APT are also discussed.

42 ENGINEERING↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

Development of Automated Atom Probe Tomography capability to study the influence of applied voltage and laser power on the final apparent composition of the analyzed specimen

This study presents the development and implementation of an autonomous Bayesian optimization (BO) framework for controlling and optimizing experimental parameters in Atom Probe Tomography (APT). Using commercial silicon needle samples as a benchmark system, we demonstrate that BO can efficiently navigate the complex parameter space of voltage and laser power to achieve target charge state ratios (specifically Si + /(Si + +Si 2+ )) with minimal experimental evaluations. Our implementation integrates Gaussian Process modeling with the CAMECA atom probe control framework, enabling autonomous adjustment of experimental conditions in real-time. Results show that the algorithm successfully converges to target ratios under different scenarios: maintaining a reference ratio, increasing the ratio (favoring Si 1+ ), and decreasing the ratio (favoring Si 2+ ). The system adapts to specimen evolution during analysis, compensating for changes in apex geometry while maintaining optimization targets. This work establishes a proof of concept for AI-driven optimization in APT, addressing the traditional challenges of manual parameter tuning and paving the way for applications to more complex materials where compositional accuracy is critical.

36 MATERIALS SCIENCE↗

Towards resolving protein structures at the atomic scale using atom probe tomography

In the field of Structural Biology, Atom Probe Tomography (APT) is in the nascent stages of development wherein coarse-grained visuals of proteins have been captured. The characterization of organic samples or biomolecules through the technique is currently limited to the detection of a few dominant signatures. The problem of indecipherable characterization can inherently be traced back to multiple forms of technique-specific responses to organic samples and consequent triggers leading to organic-sample and sample-medium interactions. While it is possible for captured manifestations of protein reconstructions to seemingly appear intact from a basic visual purview, the parameter-protein associative responses throughout the structure as a direct consequence of the inherent workings of the technique (until harmonized with organic sample complexity and behavior) and field evaporation-based factors make non-aberrative atomic associations infeasible. The work focused on identifying and theorizing the (above stated and other) fundamental mechanisms that stronghold the study of intricate atomic to higher order associations in proteins through APT. Attempts at structure elucidation of the cryogenic sample under study, through indirect associations (and methods) based on other imaging techniques, further revealed the distinct and highly distortive nature at the atomic scale deterring structural tunability and thus characterization of APT based cryogenic samples under analysis. As a direct counter to the atomic scale characterization problem, by taking the experiment-specific uncertainties, and probable APT-centric organic sample-based variabilities into account, a basic result is extracted and presented. Through mass-spectrometric and computational analysis, specific individual amino acids (Sulfur-containing protein-bound amino acids) in proteins and aspects of protein structure (probable backbone fragments, partial sequence - partial backbone portions) have been identified and characterized. Under analysis considerations, a few of the simplest known and easily inferable segments that favor structural deteriorations in the reconstructions are stated. Additionally, to overcome technique-specific deterrents to the characterization of biomolecules in cryogenic sample medium, the development of a protein-labeling strategy tailored to APT is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Metastable atom probe for measuring electron beam density profiles

Metastable atom probe was developed for measuring current density in electron beam as function of two arbitrary coordinates, with spatial resolution better than 0.5 mm. Probe shows effects of space charge, magnetic fields, and other factors which influence electron current density, but operates with such low beam densities that introduced perturbation is very small.

Lockhart, J. M.↗

Elucidating the Role of Electric Fields in Fe Oxidation via an Environmental Atom Probe

We quantify the effects of intensely applied electric fields on the Fe oxidation mechanism. The specimen are pristine Fe single crystals exposing a variety of surface structures identified by field ion microscopy. These crystals are simultaneously exposed to low pressures of pure oxygen gas, on the order of 10 −7 mbar, while applying intense electric fields on their surface of several tens of volts per nanometer. The local composition of the different surface structures is probed directly and in real time using an Environmental Atom Probe and successfully compared with first principles-based models. We found that rough Fe{244} and Fe{112} facets are more reactive toward oxygen than compact Fe{024} and Fe{011} facets. Results demonstrate that the influence of an electric field on the oxidation kinetics depends on the timescales that are involved as the system evolves toward equilibrium. The initial oxidation kinetics show that strong increases in electric fields facilitate the formation of an oxide. However, as one approaches equilibrium, high field values mitigate this formation. Ultimately, this study elucidates how high externally applied electric fields can be used to dynamically exploit reaction dynamics at the nanoscale towards desired products in a catalytic reaction at mild reaction conditions.

09 BIOMASS FUELS↗

Energy-Dispersive X-ray Spectroscopy and Atom-probe Tomography Data Quantifying Component-Ratios of Multicomponent Nano-Precipitates in Ion-Irradiated Ceria

Samples of ~1 µm films of CeO2 doped with 2 wt% Mo, 1.5 wt% Ru, 0.75 wt% Pd, 0.5 wt% Re and 0.25 wt% Rh grown with pulsed laser deposition were irradiated with I2+ ions (610°C and 730°C, 1016 and 5×1016 I2+/cm2). For selected samples post-irradiation heat treatment was conducted (900°C, 1100°C). The specimens were sectioned with focussed ion beam milling and characterized in a transmission electron microscope with energy dispesive x-ray spectroscopy, and with atom-probe tomography. Energy dispersive x-ray spectroscopy was used to obtain elemental maps showing the distribution of dopants in the specimen after exposure. Some of these maps are discussed in detail in our companion article “Formation of multicomponent alloy particles in doped ceria under I2+ ion irradiation and thermal annealing” in the Journal of Nuclear Materials [REF]. Advanced computational analysis could be used to more accurately quantify local compositions. Data is provided for additional regions of interest and one additional irradiation condition. The doped Ceria film that was heat treated at 1100 °C delaminated from the substrate in most places. Samples were extracted from the underside of a delaminated piece and analyzed with atom-probe tomography. The resulting data show Ceria and a Mo-rich particle and demonstrate that this approach is feasable in principle to study local compositions in a sample exposed to such extreme conditions.

multicomponent alloys, epsilon phase, EDS, atom pr↗