Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “artifact removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

RTN-117: Image Calibration and Instrument Signal Removal for the First Year of the LSST

The NSF-DOE Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) requires calibration products that provide uniform, stable, and accurate photometric and astrometric performance across the 3.2 gigapixel focal plane and throughout the 10-year survey. This paper details the algorithms and workflows used to produce instrument calibrations and remove instrumental artifacts for Data Preview 2 (DP2)---the first end-to-end processing demonstration using on-sky data with the LSST Camera (LSSTCam). We describe the verification, acceptance, and certification framework used to assess calibration quality and quantify residual systematics. We show baseline metrics on calibrated science images to evaluate the robustness of the calibration and instrument signature removal (ISR) data processing pipelines for DP2. Finally, we summarize the known limitations observed in DP2 production and outline expected algorithmic improvements for the first public LSST data release (Data Release~1, DR1).

79 ASTRONOMY AND ASTROPHYSICS↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fourier-based methods for removing mesh anomalies from angle resolved photoemission spectra

Recent improvements to spatial resolution in angle-resolved photo-emission spectroscopy (ARPES) have made it common to perform measurements with a very brief dwell time, for the purpose of mapping the spectral function over large surface regions. However, rapid measurement modalities can suffer a grid-like intensity modulation due to a wire mesh that is typically placed in front of the ARPES detector to block stray electrons. Here, we explore Fourier-based methods that can effectively remove this artifact, and improve the quality of ARPES images obtained in rapid scanning modes. In conclusion, an open source software package is provided containing implementations of demonstrated algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale defect evaluation framework combining real-time transmission electron microscopy and integrated machine learning-particle filter estimation

Observation of dynamic processes by transmission electron microscopy (TEM) is an attractive technique to experimentally analyze materials’ nanoscale phenomena and understand the microstructure-properties relationships in nanoscale. Even if spatial and temporal resolutions of real-time TEM increase significantly, it is still difficult to say that the researchers quantitatively evaluate the dynamic behavior of defects. Images in TEM video are a two-dimensional projection of three-dimensional space phenomena, thus missing information must be existed that makes image’s uniquely accurate interpretation challenging. Therefore, even though they are still a clustering high-dimensional data and can be compressed to two-dimensional, conventional statistical methods for analyzing images may not be powerful enough to track nanoscale behavior by removing various artifacts associated with experiment; and automated and unbiased processing tools for such big-data are becoming mission-critical to discover knowledge about unforeseen behavior. We have developed a method to quantitative image analysis framework to resolve these problems, in which machine learning and particle filter estimation are uniquely combined. The quantitative and automated measurement of the dislocation velocity in an Fe-31Mn-3Al-3Si autunitic steel subjected to the tensile deformation was performed to validate the framework, and an intermittent motion of the dislocations was quantitatively analyzed. The framework is successfully classifying, identifying and tracking nanoscale objects; these are not able to be accurately implemented by the conventional mean-path based analysis.

36 MATERIALS SCIENCE↗

Tilted fluctuation electron microscopy

Fluctuation electron microscopy (FEM) is a scanning nanodiffraction-based method that offers a unique approach to characterizing nanometer-scale medium-range order (MRO) in disordered materials. In addition to determining the degree of MRO, careful analysis of scanning nanodiffraction data can also be used to determine strain in thin film amorphous samples. We applied FEM to characterize the strain and MRO of magnetron sputtered amorphous tantalum (a-Ta) thin films over a range of tilt angles from 0° to 45° in order to measure any deviations between the in-plane and out-of-plane strain and MRO. We validate our approach using electron diffraction simulations of FEM experiments for a-Ta. We measure anisotropic strain in the simulated a-Ta diffraction patterns and find that the experimental a-Ta is isotropically strained within the accuracy of our method. Our approach provides a workflow for acquiring tilted scanning nanodiffraction data, determining the relative strain and ordering as a function of in- A nd out-of-plane directions, and removing any artifacts induced in FEM data due to strain. We also describe some limitations of the tilted FEM method when applied to thin films with very low strains.

36 MATERIALS SCIENCE↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

X-ray computed tomography using partially coherent Fresnel diffraction with application to an optical fiber

A reconstruction algorithm for partially coherent x-ray computed tomography (XCT) including Fresnel diffraction is developed and applied to an optical fiber. The algorithm is applicable to a high-resolution tube-based laboratory-scale x-ray tomography instrument. The computing time is only a few times longer than the projective counterpart. The algorithm is used to reconstruct, with projections and diffraction, a tilt series acquired at the micrometer scale of a graded-index optical fiber using maximum likelihood and a Bayesian method based on the work of Bouman and Sauer. The inclusion of Fresnel diffraction removes some reconstruction artifacts and use of a Bayesian prior probability distribution removes others, resulting in a substantially more accurate reconstruction.

Levine, Zachary H. (ORCID:000000029928276X)↗

HEU Removal from MNSR Reactors

This artifact is a slide presentation about spent HEU core removal of a Chinese-built Miniature Neutron Source Reactor (MNSR). The presentation describes the Skoda VPVR/M cask in detail and the auxiliary equipment needed to safely remove the spent HEU and transport it. Removal activities of MNSR spent HEU from Ghana and Nigeria MNSRs, and air transport from these countries to China are discussed. The International MNSR Training Facility in Ghana is also mentioned.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An additive manufacturing design approach to achieving high strength and ductility in traditionally brittle alloys via laser powder bed fusion

Additive Manufacturing (AM) presents unprecedented opportunities to enable design freedom in parts that are unachievable via conventional manufacturing. However, AM-processed components generally lack the necessary performance metrics for widespread commercial adoption. We present a novel AM processing and design approach using removable heat sink artifacts to tailor the mechanical properties of traditionally low strength and low ductility alloys. The design approach is demonstrated with the Fe-50 at.% Co alloy, as a model material of interest for electromagnetic applications. AM-processed components exhibited unprecedented performance, with a 300 % increase in strength and an order-of-magnitude improvement in ductility relative to conventional wrought material. These results are discussed in the context of product performance, production yield, and manufacturing implications toward enabling the design and processing of high-performance, next-generation components, and alloys.

36 MATERIALS SCIENCE↗

Quantum many-body calculations using body-centered cubic lattices

It is often computationally advantageous to model space as a discrete set of points forming a lattice grid. This technique is particularly useful for computationally difficult problems such as quantum many-body systems. For reasons of simplicity and familiarity, nearly all quantum many-body calculations have been performed on simple cubic lattices. Since the removal of lattice artifacts is often an important concern, it would be useful to perform calculations using more than one lattice geometry. In this paper we show how to perform quantum many-body calculations using auxiliary-field Monte Carlo simulations on a three-dimensional body-centered cubic (BCC) lattice. As a benchmark test we compute the ground state energy of 33 spin-up and 33 spin-down neutrons in the unitary limit, which is an idealized limit where the interaction range is zero and scattering length is infinite. As a fraction of the free Fermi gas energy E FG , we find that the ground state energy is E 0 /E FG =0.369(2),0.371(2), using two different definitions of the finite-system energy ratio. This is in excellent agreement with recent results obtained on a cubic lattice [He et al., Phys. Rev. A 101, 063615 (2020)]. We find that the computational effort and performance on a BCC lattice is approximately the same as that for a cubic lattice with the same number of lattice points. We discuss how the lattice simulations with different geometries can be used to constrain the size of lattice artifacts in simulations of continuum quantum many-body systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Coupled Cluster Theory for Nonadiabatic Dynamics: Nuclear Gradients and Nonadiabatic Couplings in Similarity Constrained Coupled Cluster Theory

Coupled cluster theory is one of the most accurate electronic structure methods for predicting ground and excited state chemistry. However, the presence of numerical artifacts at electronic degeneracies, such as complex energies, has made it difficult to apply the method in nonadiabatic dynamics simulations. While it has already been shown that such numerical artifacts can be fully removed by using similarity constrained coupled cluster (SCC) theory [J. Phys. Chem. Lett. 2017, 8(19), 4801–4807], simulating dynamics requires efficient implementations of gradients and nonadiabatic couplings. Here, we present an implementation of nuclear gradients and nonadiabatic derivative couplings at the similarity constrained coupled cluster singles and doubles (SCCSD) level of theory, thereby making possible nonadiabatic dynamics simulations using a coupled cluster theory that provides a correct description of conical intersections between excited states. We present a few numerical examples that show good agreement with literature values and discuss some limitations of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

Self-Admitted Technical Debt in Scientific Software: Prioritization, Sentiment, and Propagation Across Artifacts

Self-admitted technical debt (SATD) impairs scientific software (SSW), yet its prioritization, sentiment, persistence, and propagation remains underexplored. Understanding how SSW developers express, and address SATD is crucial for improving SSW maintenance, and tooling. This study investigates how SATD types and artifacts in SSW are prioritized, how sentiment relates to urgency, SATD removal and resolution rates, and the extent to which SATD propagates across artifacts. We analyzed nine SSW repositories using a SATD classification model and a semantic embedding-based prioritization heuristic. SATD was examined across multiple artifacts, with sentiment assessed via a fine-tuned transformer. Propagation was traced, priority scores compared to static analysis, and removal and resolution rates quantified. SATD in comments, commits, and pull requests receive higher priority than SATD in issues, with negative sentiment amplifying urgency. Resolution and removal rates lag behind open-source software (OSS) averages. Most SATD remains confined to the originating artifact, but longer propagation chains are rare and correlate with higher priority, highlighting persistent and high impact debt. Prioritization is influenced by artifact type and sentiment, while low removal and resolution rates signal persistent debt. Cross-artifact propagation marks high priority, unresolved SATD, providing empirical guidance for targeted monitoring, review prioritization, and tool supported maintenance in SSW.

Melin, Eric [Boise State University]↗

Trimming and Decontamination of Metagenomic Data can Significantly Impact Assembly and Binning Metrics, Phylogenomic and Functional Analysis

Background: Investigators using metagenomic sequencing to study microbiomes often trim and decontaminate reads without knowing their effect on downstream analyses. Objective: This study was designed to evaluate the impacts JGI trimming and decontamination procedures have on assembly and binning metrics, placement of MAGs into species trees, and functional profiles of MAGs extracted from complex rhizosphere metagenomes, as well as how more aggressive trimming impacts these binning metrics. Methods: Twenty-three Miscanthus x giganteus rhizosphere metagenomes were subjected to different combinations and thresholds of force, kmer, and quality trimming and decontamination using BBDuk. Reads were assembled and binned in KBase. Phylogenomic and statistical analyses were applied to evaluate the effects of trimming and decontamination on downstream analyses. Results: We found that JGI trimmed and decontaminated reads had significant impacts on assembly and binning metrics compared to raw reads, including significantly higher total contig counts, more contigs greater than 10k bp in length, and larger total lengths of raw assemblies compared to QC assemblies, and 2.0% lower average contamination of QC MAGs compared to raw MAGs. We also found that differences in the placement of MAGs in species trees increased with decreasing completeness and contamination thresholds. Furthermore, aggressive trimming (Q20) was found to significantly reduce MAG counts. Conclusion: Trimming and decontamination of metagenomics reads prior to assembly can change an investigator’s answer to the questions, “Who is there and what are they doing?” However, mild trimming and decontamination of metagenomic reads with high-quality scores are recommended for removing sample processing and sequencing artifacts.

Whitham, Jason M.↗

Seeing the whole picture: Methods for getting the most from micro X-ray computed tomography of TRISO nuclear fuel particles

Tristructural isotropic (TRISO) coated fuel particles are a nuclear fuel form under extensive study for use in advanced nuclear reactor concepts. TRISO fuels are subjected to high temperature neutron irradiations and then examined to assess their performance by determining fission product retention and studying morphological changes. Micro X-ray computed tomography is one method of nondestructively studying the effects of TRISO performance. This work addresses the need for image processing to remove X-ray tomographic reconstruction artifacts that prevent the study of TRISO features, as the TRISO particles’ high Z kernel can introduce metal artifacts that degrade the image quality in the surrounding low Z coating layers. These metal artifacts were reduced by imaging the TRISO particles with both high- and low-energy X-rays and applying a mask to the radiographs obtained with low-energy X-rays to digitally remove the dense fuel kernel region. These masked radiographs were then used to produce a tomographic reconstruction which was combined with the tomographic reconstruction of the high-energy data. This enabled the relatively-low-density TRISO buffer layer to be examined in more detail, providing information on irradiation induced dimensional changes of the coatings. This methodology, which helps see the full picture of a TRISO particle, is not limited to nuclear fuels but can be applied to systems that contain highly attenuating material surrounded by less dense materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fourier Analyses of High-Order Continuous and Discontinuous Galerkin Methods

In this paper, we present a Fourier analysis of wave propagation problems subject to a class of continuous and discontinuous discretizations using high-degree Lagrange polynomials. This allows us to obtain explicit analytical formulas for the dispersion relation and group velocity and, for the first time to our knowledge, characterize analytically the emergence of gaps in the dispersion relation at specific wavenumbers, when they exist, and compute their specific locations. Wave packets with energy at these wavenumbers will fail to propagate correctly, leading to significant numerical dispersion. We also show that the Fourier analysis generates mathematical artifacts, and we explain how to remove them through a branch selection procedure conducted by analysis of eigenvectors and associated reconstructed solutions. The higher frequency eigenmodes, named erratic in this study, are also investigated analytically and numerically.

97 MATHEMATICS AND COMPUTING↗

Using a modified double deep image prior for crosstalk mitigation in multislice ptychography

Multislice ptychography is a high-resolution microscopy technique used to image multiple separate axial planes using a single illumination direction. However, multislice ptychography reconstructions are often degraded by crosstalk, where some features on one plane erroneously contribute to the reconstructed image of another plane. Here, the use of a modified `double deep image prior' (DDIP) architecture is demonstrated in mitigating crosstalk artifacts in multislice ptychography. Utilizing the tendency of generative neural networks to produce natural images, a modified DDIP method yielded good results on experimental data. For one of the datasets, it is shown that using DDIP could remove the need of using additional experimental data, such as from X-ray fluorescence, to suppress the crosstalk. This method may help X-ray multislice ptychography work for more general experimental scenarios.

36 MATERIALS SCIENCE↗