Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array induction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PRIMA: The PRobe Far-Infrared Mission for Astrophysics

PRIMA is a far-infrared observatory concept being developed to address timely and fundamental questions about the growths of galaxies and solar systems and their constituents. It will observe the build-up of heavy elements, dust, stars, and black holes in galaxies and their interrelationships, and trace the masses and water contents of protoplanetary disks to probe the growths of solar systems. The majority of observing time will be devoted to Guest Observer programs to enable the astrophysics community to identify and plan the most critical observations, with focused PI programs to address key science with rapid releases of data to inform community planning. PRIMA will have spectral, hyperspectral imaging, and polarimetric capabilities, enabled now for the first time by extraordinary progress in kinetic inductance detector (KID) array technology over the last two decades. The 2.0-meter telescope will be cooled to < 5 K to take maximum advantage of the KID sensitivities. For observations of atomic fine-structure lines, molecular lines, and solid-state emission and absorption bands, R = 200 spectral coverage will range from approximately 25 µm to 200 µm, with a high-resolution mode across the entire band that will have a spectral resolving power of a few thousand at 100 µm. R ~ 10 moderate-resolution (hyperspectral) imaging will range from 25 to 80 µm for rest-frame, mid- and far-infrared spectral energy distribution measurements to probe dust grain composition and disambiguate star formation and active galactic nuclei in galaxies. Polarimetric observations of large areas of Galactic molecular clouds and the Magellanic Clouds from 80 to ~200 µm will bridge between the large-scale polarimetry of the interstellar medium from cosmic microwave background observatories and protostellar disk-scale interferometric observations to probe magnetic fields at the critical scales at which clouds collapse to form stars. An overview of PRIMA’s basic design and capabilities will be presented. Other posters in this session describe PRIMA science, technology, and instrumentation in greater depth.

Jason Glenn↗

SPT-3G+: mapping the high-frequency cosmic microwave background using kinetic inductance detectors

We present the design and science goals of SPT-3G+, a new camera for the South Pole Telescope, which will consist of a dense array of 34100 kinetic inductance detectors measuring the cosmic microwave background (CMB) at 220, 285 and 345 GHz. The SPT-3G+ dataset will enable new constraints on the process of reionization, including measurements of the patchy kinematic Sunyaev-Zeldovich effect and improved constraints on the optical depth due to reionization. At the same time, it will serve as a pathfinder for the detection of Rayleigh scattering, which could allow future CMB surveys to constrain cosmological parameters better than from the primary CMB alone. In addition, the combined, multi-band SPT-3G and SPT-3G+ survey data, will have several synergies that enhance the original SPT-3G survey, including: extending the redshift-reach of SZ cluster surveys to z > 2; understanding the relationship between magnetic fields and star formation in our Galaxy; improved characterization of the impact of dust on inflationary B-mode searches; and characterizing astrophysical transients at the boundary between mm and sub-mm wavelengths. Finally, the modular design of the SPT-3G+ camera allows it to serve as an on-sky demonstrator for new detector technologies employing microwave readout, such as the on-chip spectrometers that we expect to deploy during the SPT-3G+ survey. In this paper, we describe the science goals of the project and the key technology developments that enable its powerful yet compact design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

Quantum Versus Classical Switching Dynamics of Driven Dissipative Kerr Resonators

Here, we report a first-principles study of the driven dissipative dynamics for Kerr oscillators in the mesoscopic regime. This regime is characterized by large Kerr nonlinearity, realized here using the nonlinear kinetic inductance of a large array of Josephson junctions. The experimentally measured nonlinear resonance lineshapes of the junction array modes show significant deviations from steady-state numerical predictions, and necessitate time-dependent numerical simulations indicative of strong measurement-induced dephasing in the system arising from the large cross-Kerr effect between array modes. Analytical and numerical calculations of switching rate corroborate this by showing the emergence of a slow time scale, which is much longer than the linear decay rate and is set by fluctuation-induced switching times in the bistable regime. Furthermore, our analysis shows that the usual quantum-activated escape treatment is inadequate for prediction of the switching rates at large frequency shifts caused by strong nonlinearities, necessitating a quantum treatment that utilizes the full system Liouvillian. Based on our analysis, we identify a universal crossover parameter that delineates the regimes of validity of semiclassical and quantum descriptions, respectively. Our work shows how dynamical switching effects in strongly nonlinear systems provide a platform to study quantum-to-classical transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Magneto-inductive skin sensor for robot collision avoidance: A new development

Safety is a primary concern for robots operating in space. The tri-mode sensor addresses that concern by employing a collision avoidance/management skin around the robot arms. This rf-based skin sensor is at present a dual mode (proximity and tactile). The third mode, pyroelectric, will complement the other two. The proximity mode permits the robot to sense an intruding object, to range the object, and to detect the edges of the object. The tactile mode permits the robot to sense when it has contacted an object, where on the arm it has made contact, and provides a three-dimensional image of the shape of the contact impression. The pyroelectric mode will be added to permit the robot arm to detect the proximity of a hot object and to add sensing redundancy to the two other modes. The rf-modes of the sensing skin are presented. These modes employ a highly efficient magnetic material (amorphous metal) in a sensing technique. This results in a flexible sensor array which uses a primarily inductive configuration to permit both capacitive and magnetoinductive sensing of object; thus optimizing performance in both proximity and tactile modes with the same sensing skin. The fundamental operating principles, design particulars, and theoretical models are provided to aid in the description and understanding of this sensor. Test results are also given.

Chauhan, D. S.↗

Inductive energy storage for MPD thrusters

The high thrust density of the self-field magnetoplasmadynamic (MPD) thruster makes it a promising candidate for many advanced space missions. The high power requirements of this thruster lead to its operation in a pulsed mode from an energy storage device. The system characteristics of an inductive energy storage circuit with a solar array power from 25 kwe to 400 kwe are considered, by solving the circuit equations for the inductor charge and discharge phases. Using simple analytic models of the circuit components, the total system efficiency and inductance are determined as functions of the array output power and circuit resistance. The total system efficiency increases with array power and is acceptable only for low values of circuit resistance, indicating that superconducting circuitry may be desirable. The optimum charge-discharge cycle changes fundamentally as the circuit resistance is decreased through a critical value dependent on the thruster operating characteristics.

Rudolph, L. K.↗

Can lidars assess wind plant blockage in simple terrain? A WRF-LES study

Wind plant blockage reduces wind velocity upstream of wind plants, reducing the power generated by turbines adjacent to the inflow, and potentially throughout the plant as well. The nature of the mechanism that amplifies blockage as well as the velocity reductions in both the induction zone and potentially deeper into the array are not well understood. Field observations can provide valuable insight into the characteristics of the induction zone and the mechanisms that amplify it. However, the relatively small velocity reductions that have been measured experimentally pose a challenge in quantifying blockage, especially in onshore environments with flow heterogeneities that may be of the same scale as the blockage effect itself. We simulate the flow around the King Plains wind plant in the relatively simple terrain of Oklahoma, the location of the American WAKE experimeNt, to evaluate wind plant blockage in this environment. Using numerical simulations, we find the largest velocity deceleration (0.64 m s−1; 8%) immediately upstream of the wind plant, and 1% velocity deficits 24 rotor diameters upstream of the first turbine row. We also use virtual measurements upstream of the wind plant to analyze the uncertainties and difficulties in measuring blockage using a scanning lidar on shore. Based on our virtual lidar study, the induction zone of land-based wind plants can be incorrectly estimated using observations if the effects of nonuniform terrain on the flow are not carefully considered. Changes in terrain elevation produce local variations in wind speed (as measured by a scanning lidar) that exceed in magnitude the deceleration within the induction zone. We refer to these local changes in wind speed as terrain effects. A methodology to differentiate between terrain effects and blockage in experimental settings is proposed and evaluated herein, highlighting the difficulties and uncertainties associated with measurement and simulation of blockage in even relatively simple onshore environments.

17 WIND ENERGY↗

An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

semi-empirical model↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

Inductively Coupled Plasma Etching for Delineation of InAs/GaSb Pixels

We developed 320x256 Complimentary Barrier Infrared (CBIRD) focal plane array (FPA) for long wave infrared (LWIR) imaging application. The FPA layers grown by molecular beam epitaxy (MBE) had 300 periods 1.9 micro m thick absorber. The CBIRD arrays showed the mean dark current density of 2.2 x 10(exp -4) A/cm2, when 128 mV bias voltage was applied. The long wave cut off was observed at 8.8 micrometers at the 50% peak and the maximum quantum efficiency was 54% at 5.6 micrometers. The arrays had 81% fill factor with 97% operability with noise equivalent difference temperature (NE(delta)T) of 18.6 mK and a mean detectivity of D*=1.3 x 10(exp 11) Hz(exp 1/2)/W.

InAs/GaSb↗