Engineering PapersSearch

SEARCH · Engineering Papers

Results for “anode degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development and Testing of High Surface Area Iridium Anodes for Molten Oxide Electrolysis

Processing of lunar regolith into oxygen for habitat and propulsion is needed to support future space missions. Direct electrochemical reduction of molten regolith is an attractive method of processing, because no additional chemical reagents are needed. The electrochemical processing of molten oxides requires high surface area, inert anodes. Such electrodes need to be structurally robust at elevated temperatures (1400-1600?C), be resistant to thermal shock, have good electrical conductivity, be resistant to attack by molten oxide (silicate), be electrochemically stable and support high current density. Iridium with its high melting point, good oxidation resistance, superior high temperature strength and ductility is the most promising candidate for anodes in high temperature electrochemical processes. Several innovative concepts for manufacturing such anodes by electrodeposition of iridium from molten salt electrolyte (EL-Form? process) were evaluated. Iridium electrodeposition to form of complex shape components and coating was investigated. Iridium coated graphite, porous iridium structure and solid iridium anodes were fabricated. Testing of electroformed iridium anodes shows no visible degradation. The result of development, manufacturing and testing of high surface, inert iridium anodes will be presented.

Shchetkovskiy, Anatoliy

Networks of electrochemical oxidation of common lithium-ion Battery solvents revealed by NMR spectroscopy

Raising the upper cutoff voltage of lithium-ion batteries (LIBs) to increase energy density often exceeds the electrolyte’s anodic stability limit, accelerating degradation and creating a major durability tradeoff. Designing electrolytes that can sustain long-term high-voltage cycling requires a clearer understanding of the fundamental mechanisms occurring when commercial carbonate solvents oxidize. Here, to this end, simplified single-salt, single-solvent formulations of LiClO 4 and LiPF 6 in dimethyl carbonate (DMC), ethylene carbonate (EC), or ethyl methyl carbonate (EMC) were anodically electrolyzed on inert electrodes and monitored for extended periods of time using 1 H, 13 C, 19 F, and 35 Cl nuclear magnetic resonance (NMR) spectroscopy. The controlled environment of the experiments, coupled to the unique sensitivity of NMR, unveiled novel metastable intermediates and the formation of branching networks of products with temporal evolution. Oxidation of the pristine solvent primarily proceeds through a radical pathway that also produces highly reactive protons but faces competition from a second pathway involving a radical carbocation intermediate. In all cases, the intermediates follow a variety of downstream pathways that can intersect with each other. The concomitant network of reactions represents a significant increase in complexity compared to common descriptions in the literature, yet, critically, it helps explain the wide range of products typically identified in electrolyte oxidation in complete cells. The results highlight the need for refocusing fundamental research on anodic stability to analysis of the hierarchy of reaction networks to better inform efforts to mitigate the detrimental effects on battery performance, including prevention and harvesting of proton and radical products.

Electrolytes

Fluorinated Glyme Solvents to Extend Lithium-Sulfur Battery Life (Final Technical Report, Unlimited)

This project investigated a number of partially fluorinated glymes (PFGs) as electrolyte cosolvents to improve the performance of lithium-sulfur (Li-S) batteries. A major issue in Li-S cells is the electrochemical reaction of sulfur in the cathode to form lithium polysulfides (LPS) that dissolve in the electrolyte. Those LPS are electrochemically and chemically reactive at the lithium anode, resulting in lithium sulfide deposition on the anode and also electrochemical reaction at both the anode and cathode, leading to a “polysulfide shuttle” and reduced coulombic efficiency (CE) and self-discharge of the cell. PFGs reduce the solubility of LPS while maintaining good solubility of lithium salts such as LiTFSI. By adjusting the amount of PFG as cosolvent in the electrolyte, we showed that the solubility of LPS in the electrolyte can be tuned. (It is not desirable to completely eliminate LPS in the electrolyte, as they facilitate electrochemical reaction of the electrically insulating S 8 and Li 2 S within the cathode by shuttling charge between them and the conductive carbon.) Another issue in Li-S cells is degradation of the Li anode over many cycles of stripping (discharge) and plating (charge). We showed that PFGs have a beneficial effect on the physical morphology of the Li anode, SEI formation, and the CE of a Li-Li cell. Among the many PFGs tested, we found the best performance from PFGs designated PFG2 and PFG5, and these two PFGs were thoroughly studied. A systematic coin-cell study of electrolyte solvents of 90:10, 80:20, or 70:30 DME:PFG (DME = 1,2-dimethoxyethane) revealed some systematic trends: a higher percentage of PFG solvent led to substantially longer cycle life, but at the same time reduced specific capacity (mAh/g(S)) and cell capacity at higher rates. These studies used LiFSI as the electrolyte salt, as it was found to extend cycle life compared to LiTFSI. Finally, the addition of a small amount of 1,3-dioxolane (DOL) to the electrolyte was found to be beneficial. The overall optimal electrolyte solution was found to be 0.6 M LiFSI + 0.5 M LiNO 3 in 75:5:20 DME/DOL/PFG (either PFG2 or PFG5).

25 ENERGY STORAGE

Fracture Dynamics in Silicon Anode Solid-State Batteries

Solid-state batteries (SSBs) with silicon anodes could enable improved safety and energy density compared to lithium-ion batteries. However, degradation arising from the massive volumetric changes of silicon anodes during cycling is not well understood in solid-state systems. Here, we use operando X-ray computed microtomography to reveal micro- to macro-scale chemo-mechanical degradation processes of silicon anodes in SSBs. Mud-type channel cracks driven by biaxial tensile stress form across the electrode during delithiation. We also find detrimental cracks at the silicon/ solid electrolyte interface that form due to local reaction competition between neighboring domains of different sizes. Continuum phase-field damage modeling quantifies stress-driven channel cracking and shows that the lithiated silicon stress state is critical for determining the extent of interfacial fracture. This work reveals the mechanisms that govern SSBs compared to conventional lithium-ion batteries and provides guidelines for engineering chemomechanically resilient electrodes for high-energy batteries.

25 ENERGY STORAGE

Effect of Post-HALT Annealing on Leakage Currents in Solid Tantalum Capacitors

Degradation of leakage currents is often observed during life testing of tantalum capacitors and is sometimes attributed to the field-induced crystallization in amorphous anodic tantalum pentoxide dielectrics. However, degradation of leakage currents and the possibility of annealing of degraded capacitors have not been investigated yet. In this work the effect of annealing after highly accelerated life testing (HALT) on leakage currents in various types of solid tantalum capacitors was analyzed. Variations of leakage currents with time during annealing at temperatures from 125 oC to 180 oC, thermally stimulated depolarization (TSD) currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. Annealing resulted in a gradual decrease of leakage currents and restored their initial values. Repeat HALT after annealing resulted in reproducible degradation of leakage currents. The observed results are explained based on ionic charge instability (drift/diffusion of oxygen vacancies) in the tantalum pentoxide dielectrics using a modified Schottky conduction mechanism.

Teverovsky, Alexander

Inert gas ion thruster development

Two 12 cm magneto-electrostatic containment (MESC) ion thrusters were performance mapped with argon and xenon. The first, hexagonal, thruster produced optimized performance of 48.5to 79 percent argon mass utilization efficiencies at discharge energies of 240 to 425 eV/ion, respectively, Xenon mass utilization efficiencies of 78 to 95 percent were observed at discharge energies of 220 to 290 eV/ion with the same optimized hexagonal thruster. Changes to the cathode baffle reduced the discharge anode potential during xenon operation from approximately 40 volts to about 30 volts. Preliminary tests conducted with the second, hemispherical, MESC thruster showed a nonuniform anode magnetic field adversely affected thruster performance. This performance degradation was partially overcome by changes in the boundary anode placement. Conclusions drawn the hemispherical thruster tests gave insights into the plasma processes in the MESC discharge that will aid in the design of future thrusters.

Ramsey, W. D.

Life test studies on tungsten impregnated cathodes

NASA-Lewis Research Center has conducted an ongoing life test program on commercial impregnated tungsten cathodes since 1971. This brief is an update of the information as of December 1979. B-type cathodes, operated at 1100 C have been run in simulated microwave tubes at 2 A/sq cm for more than four years with about 6-percent degradation in current at a constant reference anode voltage. M-type cathodes have been operated for 30,000 h at a cathode temperature of 1010 C and 2 A/sq cm with no degradation in current as a constant reference anode voltage.

Forman, R.

Critical insights into the steam electrolysis electrode in protonic ceramic cells for hydrogen production

Intermediate-temperature protonic ceramic electrolysis cells (PCECs), which combine the benefits of both lower- and higher-temperature electrolysis, are among the most efficient technologies for the production of green hydrogen. To ensure economic competitiveness and broad adoption, ongoing innovations in cell materials are essential to improve durability and reduce costs. The water oxidation half-reaction at the anode is a key area for improvement as it is a major contributor to performance degradation and efficiency loss in PCECs. Current anode designs, which are largely derived from solid oxide electrolysis cells, fail to address the specific requirements for PCECs under realistic operating conditions. Here, this Perspective highlights the unique challenges faced by PCEC anodes, focusing on the impact of high steam concentrations and the critical role of proton-coupled electron-transfer mechanisms—factors that are absent in solid oxide electrolysis cells. Furthermore, we explore design principles for advancing anodes tailored for PCECs, offering guidance for future research and development in this promising field.

Electrocatalysis

The Impact of Catalyst Layer Properties and Transport Layer Interactions on Rutile Iridium Oxide Anode Durability in Proton Exchange Membrane Electrolysis

The performance and durability of proton exchange membrane electrolyzers are governed by the interplay between catalyst inks and integration, the resulting catalyst layer (CL) structure, and the interface between the CL and porous transport layer (PTL). In this study, we examine the impact of these factors on cell performance and degradation using rutile IrO2 as the anode catalyst. The two commercial rutile IrO2 catalysts differ from each other and from the amorphous benchmark in agglomerate size and ink stability. This has implications for CL morphology and electronic connectivity. In the context of long-term pressurized operation for up to 1000 h, the selection of the PTL has a marginal effect on the durability of CLs with good structural and compositional properties, whereas poorly structured CLs demonstrate evident degradation when used with certain PTLs. Poor CL properties amplify the negative impact of non-ideal CL/PTL interfaces, demonstrating the importance of CL/PTL interface engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE

Decoupling Failure Pathways in Li-O 2 Cells Operated Under Lean Electrolyte Conditions

The operation of lithium-oxygen (Li-O 2 ) batteries under lean electrolyte conditions offers higher energy density but leads to rapid degradation and short cycle life. Although cathode passivation and electrolyte decomposition occur in all regimes, we show that under lean electrolyte conditions, failure is primarily driven by progressive electrolyte consumption at the lithium/solid electrolyte interphase (SEI), rather than by irreversible cathode passivation. Poor wetting of the lithium surface results in heterogeneous SEI growth and high local current densities, which accelerate electrolyte loss and cell failure. Strategies aimed at improving interfacial stability, including optimized wetting and SEI forming additives, significantly extend cycle life without compromising energy density. Our results establish anode-electrolyte interactions as the dominant degradation mechanism under lean electrolyte conditions, and emphasize the need to engineer a stable Li/SEI interface for long-lasting Li-O 2 batteries.

Córdoba, Daniel [Argonne National Laboratory (ANL)

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE

Development of advanced fuel cell system, phase 3

A multiple task research and development program was performed to improve the weight, life, and performance characteristics of hydrogen-oxygen alkaline fuel cells for advanced power systems. Gradual wetting of the anode structure and subsequent long-term performance loss was determined to be caused by deposition of a silicon-containing material on the anode. This deposit was attributed to degradation of the asbestos matrix, and attention was therefore placed on development of a substitute matrix of potassium titanate. An 80 percent gold 20 percent platinum catalyst cathode was developed which has the same performance and stability as the standard 90 percent gold - 10 percent platinum cathode but at half the loading. A hybrid polysulfone/epoxy-glass fiber frame was developed which combines the resistance to the cell environment of pure polysulfone with the fabricating ease of epoxy-glass fiber laminate. These cell components were evaluated in various configurations of full-size cells. The ways in which the baseline engineering model system would be modified to accommodate the requirements of the space tug application are identified.

Handley, L. M.

Reversible Losses in Proton Exchange Membrane Water Electrolysis

Lower anode catalyst loadings and higher current densities are essential to lowering the levelized cost of H 2 production via proton exchange membrane water electrolysis (PEMWE). However, these approaches can induce significant durability challenges. Here, we show that cell degradation can include large reversible voltage losses across a variety of conditions, including low loadings and high currents. Although there is limited published discussion of reversible voltage losses in PEMWE, we demonstrate that they are an important consideration in cell efficiency and durability. Understanding the mechanisms of reversible losses and developing mitigation strategies is therefore a key priority for enabling low-cost PEMWE.

08 HYDROGEN

Impact of Anode to Cathode Crossover in Lithium‐metal Batteries With High‐Nickel Cathodes

The advancement of high-energy-density lithium-metal batteries (LMBs) is hindered by the chemical instability of both lithium-metal anode and high-nickel layered oxide cathodes. While cathode-to-anode crossover is well-documented, the reverse process of anode-to-cathode crossover remains underexplored. Here, we systematically investigate such crossovers and the degradation pathway in pouch cells with a localized high-concentration electrolyte, comparing NMC622, NMC811, and NMC90 cathodes paired with lithium-metal and graphite anodes. Despite delivering higher initial capacities, LMBs exhibit faster capacity fade under long-term cycling at 45 °C. To isolate cathode-side degradation, galvanostatic electrochemical impedance spectroscopy (GEIS) measurements of cycled cathodes paired with delithiated lithium iron phosphate (LFP) counter electrodes reveal significantly higher charge-transfer resistance in cathodes cycled with lithium-metal. Surface characterization via X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) reveals greater electrolyte decomposition on cathodes cycled with lithium metal, leading to thicker, more organic-rich cathode–electrolyte interphases (CEIs), consistent with the elevated charge-transfer resistance observed in GEIS measurements. Notably, NMC90 shows the most pronounced CEI thickening, linking higher cathode surface reactivity to greater susceptibility to anode-to-cathode crossover. This work presents compelling evidence of crosstalk degradation originating from lithium-metal anodes and underscores the importance of cross-interface stability for the design of durable LMBs.

25 ENERGY STORAGE

Plasma effects on the passive external thermal control coating of Space Station Freedom

The current baseline chromic acid anodized thermal control coating on 6061-T6 aluminum meteoroid debris (M/D) shields for SSF has been evaluated. The degradation of the solar absorptance, alpha, and the thermal emittance, epsilon, of chromic acid anodized aluminum due to dielectric breakdown in plasma was measured to predict the on-orbit lifetime of the SSF M/D shields. The lifetime of the thermal control coating was based on the surface temperatures achieved with degradation of the thermal control properties, alpha and epsilon. The temperatures of each M/D shield from first element launch (FEL) through FEL+15 years were analyzed. It is shown that the baseline thermal control coating cannot withstand the -140 V potential between the conductive structure of the SSF and the current plasma environment.

Carruth, Ralph, Jr.

Understanding the Cathode Electrochemistry of Humidified Solid‐State Lithium‐Oxygen Batteries

Lithium-oxygen batteries (LOBs) possess a high theoretical energy density, making them potential candidates for next-generation energy storage. However, challenges such as reactive oxygen species-induced component degradation hinder their practical use. Inorganic solid-state electrolytes offer an alternative to degradation-prone aprotic electrolytes, while also protecting lithium anodes from potential atmospheric reactants. Here, this study explores the cathode electrochemistry of solid-state LOBs using humidified oxygen, which forms an aqueous catholyte during initial cycling, thereby improving cathode-electrolyte contact. To quantitatively analyze the cathode electrochemistry, a ‘Humidity-Incorporated’ Differential Electrochemical Gas Monitoring System (HiDEMS) is developed to control humidity and monitor gas consumption and evolution in real time. When studying a Li-O 2 cell that employs a NASICON-type Li 1.3 Al 0.3 Ti 1.7 (PO 4 ) 3 (LATP) solid electrolyte and a porous carbon cathode, a shift in discharge products from Li 2 O 2 to LiOH is observed over repeated cycles. While Li 2 O 2 evolves O 2 during charging, LiOH oxidation leads to minimal O 2 release and increased CO 2 production, originating from oxidation of carbon electrodes. Further, dissolution of Al and P from LATP is observed, likely driven by the formation of the alkaline catholyte. The findings highlight the need for carbon-free cathode materials and more stable solid-state conductors to minimize side reactions and improve rechargeability in humidified solid-state Li-O 2 batteries.

LATP degradation