Medical applications of artificial olfactometry

The present invention provides methods for detecting the presence of an analyte indicative of various medical conditions, including halitosis, periodontal disease and other diseases are also disclosed.

Lewis, Nathan S.↗

Separation at Crossing Waypoints Under Wind Uncertainty in Urban Air Mobility

To enable high-density operations in major metropolitan areas, urban air mobility networks are anticipated to have air traffic management with higher levels of autonomy. To ensure that this type of autonomy is feasible, one of the critical steps from a safety and efficiency perspective is understanding various factors that affect the spatial separation between airborne flights and ensure that these factors can be managed. In terms of separation assurance and scheduling, an important real-world concern is that future states of aircraft cannot be perfectly predicted. The focus of this research paper is to understand how these prediction errors affect separation and scheduling services and to explore mitigation strategies to handle these errors. In this research, we have simulated these types of uncertainty by adding wind-prediction errors to trajectory predictions for separation. With these wind-prediction errors, we decompose the problem into two separate questions. First, using both simulation and analytical methods, we look at conflict-detection-only scenarios to understand how the wind errors affect required minimum temporal separation between crossing flights to ensure a specific spatial separation. Next, we study how trajectory errors effect conflict resolution, and we explore different combinations of scheduling and separation assurance to mitigate the effects of uncertainty between crossing flights. The conflict resolution algorithm aims to minimize necessary temporal separation between crossing flights under uncertainty, still ensuring safety-critical spatial separation. In summary, this research suggests that the required minimum temporal separation at a crossing waypoint is dependent on factors such as inbound crossing angle, the relative angle between wind direction and bearing of each route, wind magnitude, wind magnitude uncertainty, nominal cruise airspeed of aircraft, and look-ahead time of the conflict detection algorithm. This research also suggests that different combinations of scheduling and separation have different qualitative results. Using a combination of strategic, flow-based scheduling, tactical scheduling at crossings, speed control near crossing points, and separation management leads to a system that is insensitive to trajectory prediction errors with high throughput and flexibility for aircraft away from shared resources.

urban air mobility↗

Separation at Crossing Waypoints Under Wind Uncertainty in Urban Air Mobility

To enable high-density operations in major metropolitan areas, urban air mobility networks are anticipated to have air traffic management with higher levels of autonomy. To ensure that this type of autonomy is feasible, one of the critical steps from a safety and efficiency perspective is understanding various factors that affect the spatial separation between airborne flights and ensure that these factors can be managed. In terms of separation assurance and scheduling, an important real-world concern is that future states of aircraft cannot be perfectly predicted. The focus of this research paper is to understand how these prediction errors affect separation and scheduling services and to explore mitigation strategies to handle these errors. In this research, we have simulated these types of uncertainty by adding wind-prediction errors to trajectory predictions for separation. With these wind-prediction errors, we decompose the problem into two separate questions. First, using both simulation and analytical methods, we look at conflict-detection-only scenarios to understand how the wind errors affect required minimum temporal separation between crossing flights to ensure a specific spatial separation. Next, we study how trajectory errors effect conflict resolution, and we explore different combinations of scheduling and separation assurance to mitigate the effects of uncertainty between crossing flights. The conflict resolution algorithm aims to minimize necessary temporal separation between crossing flights under uncertainty, still ensuring safety-critical spatial separation. In summary, this research suggests that the required minimum temporal separation at a crossing waypoint is dependent on factors such as inbound crossing angle, the relative angle between wind direction and bearing of each route, wind magnitude, wind magnitude uncertainty, nominal cruise airspeed of aircraft, and look-ahead time of the conflict detection algorithm. This research also suggests that different combinations of scheduling and separation have different qualitative results. Using a combination of strategic, flow-based scheduling, tactical scheduling at crossings, speed control near crossing points, and separation management leads to a system that is insensitive to trajectory prediction errors with high throughput and flexibility for aircraft away from shared resources.

urban air mobility↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

Search for and investigation of extraterrestrial forms of life

Correct combinations of remote, analytic, and functional methods and measuring devices for detecting extraterrestrial life are elaborated. Considered are techniques and instruments available both on earth and aboard spacecraft and artificial planetary satellites. Emphasis is placed on the abiogenetic synthesis of organic compounds formed in photosynthesis on Mars.

Rubin, A. B.↗

Failure detection and isolation experiments with the Langley Mini-Mast

A report is presented on experiments to demonstrate failure detection and isolation (FDI) using the flexible truss facility Mini-Mast at the NASA Langley Research Center. Two techniques are selected for study because they are applicable both to sensor and actuator failures and because they do not depend on hypotheses about the forms of possible failures. These two are the method of generalized parity relations and the failure detection filter. These methods utilize the concept of analytical redundancy and therefore their performance depends on the fidelity of the model of the dynamics of the system being monitored. Results are given for sensor FDI using generalized parity relations and input-output data collected during operation of the Mini-Mast. component failures are simulated in the data. The dependence of the performance of the methods on choices of the parameters in their implementation is explored.

Vander Velde, Wallace E.↗

Assessment of an Automated Touchdown Detection Algorithm for the Orion Crew Module

Orion Crew Module (CM) touchdown detection is critical to activating the post-landing sequence that safe?s the Reaction Control Jets (RCS), ensures that the vehicle remains upright, and establishes communication with recovery forces. In order to accommodate safe landing of an unmanned vehicle or incapacitated crew, an onboard automated detection system is required. An Orion-specific touchdown detection algorithm was developed and evaluated to differentiate landing events from in-flight events. The proposed method will be used to initiate post-landing cutting of the parachute riser lines, to prevent CM rollover, and to terminate RCS jet firing prior to submersion. The RCS jets continue to fire until touchdown to maintain proper CM orientation with respect to the flight path and to limit impact loads, but have potentially hazardous consequences if submerged while firing. The time available after impact to cut risers and initiate the CM Up-righting System (CMUS) is measured in minutes, whereas the time from touchdown to RCS jet submersion is a function of descent velocity, sea state conditions, and is often less than one second. Evaluation of the detection algorithms was performed for in-flight events (e.g. descent under chutes) using hi-fidelity rigid body analyses in the Decelerator Systems Simulation (DSS), whereas water impacts were simulated using a rigid finite element model of the Orion CM in LS-DYNA. Two touchdown detection algorithms were evaluated with various thresholds: Acceleration magnitude spike detection, and Accumulated velocity changed (over a given time window) spike detection. Data for both detection methods is acquired from an onboard Inertial Measurement Unit (IMU) sensor. The detection algorithms were tested with analytically generated in-flight and landing IMU data simulations. The acceleration spike detection proved to be faster while maintaining desired safety margin. Time to RCS jet submersion was predicted analytically across a series of simulated Orion landing conditions. This paper details the touchdown detection method chosen and the analysis used to support the decision.

Gay, Robert S.↗

Low level vapor verification of monomethyl hydrazine

The vapor scrubbing system and the coulometric test procedure for the low level vapor verification of monomethyl hydrazine (MMH) are evaluated. Experimental data on precision, efficiency of the scrubbing liquid, instrument response, detection and reliable quantitation limits, stability of the vapor scrubbed solution, and interference were obtained to assess the applicability of the method for the low ppb level detection of the analyte vapor in air. The results indicated that the analyte vapor scrubbing system and the coulometric test procedure can be utilized for the quantitative detection of low ppb level vapor of MMH in air.

Mehta, Narinder↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗

Tunable lasers and their application in analytical chemistry

The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.

Steinfeld, J. I.↗

Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods

In this work we describe an analytical method for determining the presence of organic compounds in rocks, limestone, and other composite materials. Our preliminary laboratory experiments on different rocks/limestone show that the organic component in mineralogical matrices is a minor phase on order of hundreds of ppm and can be better detected using high precision liquid chromatography (HPLC). The matrix, which is the major phase, plays an important role in embedding and protecting the organic molecules from the harsh Martian environment. Some rocks bear significant amounts of amino acids therefore, it is possible to identify these phases using powder x-ray diffraction (XRD) by crystallizing the organic. The method of detection/analysis of organics, in particular amino acids, that have been associated with life will be shown in the next section.

Dragoi, D.↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

Study of excitation transfer in a flowing helium afterglow pumped with a tuneable dye laser. II - Measurement of the rate coefficient for the rotational relaxation of He2/3p 3Pi-g/.

The results of the use of a fast-transient fluorescence technique in the examination of rotational relaxation caused by collisions with neutral helium atoms are discussed. Details regarding the production and detection of reacting species are considered, together with the analytical method used. A dye laser system with 4-methylcoumarin producing a pumping flux in the 4650 A region was employed in the investigations.

Collins, C. B.↗

Statistical analysis of SSME system data

A statistical methodology to enhance the Space Shuttle Main Engine (SSME) performance prediction accuracy is proposed. This methodology was to be used in conjunction with existing SSME performance prediction computer codes to improve parameter prediction accuracy and to quantify that accuracy. However, after a review of related literature, researchers concluded that the proposed problem required a coverage of areas such as linear and nonlinear system theory, measurement theory, statistics, and stochastic estimation. Since state space theory is the foundation for a more complete study of each of the before mentioned areas, these researchers chose to refocus emphasis to cover the more specialized topic of state vector estimation procedures. State vector estimation was also selected because of current and future concerns by NASA for SSME performance evaluation; i.e., there is a current interest in an improved evaluation procedure for actual SSME post flight performance as well as for post static test performance of a single SSME. A current investigation of analytical methods may be used to improve test stand failure detection. This paper considers the issue of post flight/test state variable reconstruction through the application of observations made on the output of the Space Shuttle propulsion system. Rogers used the Kalman filtering procedure to reconstruct the state variables of the Space Shuttle propulsion system. An objective of this paper is to give the general setup of the Kalman filter and its connection to linear regression. A second objective is to examine the reconstruction methodology for application to the reconstruction of the state vector of a single Space Shuttle Main Engine (SSME) by using static test firing data.

Temple, Enoch C.↗

Deformed Shape Calculation of a Full-Scale Wing Using Fiber Optic Strain Data from a Ground Loads Test

A ground loads test of a full-scale wing (175-ft span) was conducted using a fiber optic strain-sensing system to obtain distributed surface strain data. These data were input into previously developed deformed shape equations to calculate the wing s bending and twist deformation. A photogrammetry system measured actual shape deformation. The wing deflections reached 100 percent of the positive design limit load (equivalent to 3 g) and 97 percent of the negative design limit load (equivalent to -1 g). The calculated wing bending results were in excellent agreement with the actual bending; tip deflections were within +/- 2.7 in. (out of 155-in. max deflection) for 91 percent of the load steps. Experimental testing revealed valuable opportunities for improving the deformed shape equations robustness to real world (not perfect) strain data, which previous analytical testing did not detect. These improvements, which include filtering methods developed in this work, minimize errors due to numerical anomalies discovered in the remaining 9 percent of the load steps. As a result, all load steps attained +/- 2.7 in. accuracy. Wing twist results were very sensitive to errors in bending and require further development. A sensitivity analysis and recommendations for fiber implementation practices, along with, effective filtering methods are included

Jutte, Christine V.↗

Nine-analyte detection using an array-based biosensor

A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 x 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 x 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersiniapestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.

NASA Discipline Life Sciences Technologies↗

Extensive 1-year survey of trace elements and compounds in the airborne suspended particulate matter in Cleveland, Ohio

Concentrations of 75 chemical constituents in the airborne particulate matter were measured in Cleveland, Ohio, during 1971 and 1972. Values covering a 1-year period (45 to 50 sampling days) at each of 16 sites are presented for 60 elements. A lesser number of values is given for sulfate, nitrate, fluoride, acidity, 10 polynuclear aromatic hydrocarbon compounds, and the aliphatic hydrocarbon compounds as a group. Methods used included instrumental neutron activation, emission spectroscopy, gas chromatography, combustion techniques, and colorimetry. Uncertainties in the concentrations associated with the sampling procedures, the analysis methods, the use of several analytical facilities, and samples with concentrations below the detection limits are evaluated in detail. The data is discussed in relation to other studies and source origins. The trace constituent concentrations as a function of wind direction are used to suggest a practical method for air pollution source identification.

King, R. B.↗

Elemental composition of airborne particulates and source identification - An extensive one year survey

Concentrations of 60 chemical elements in the airborne particulate matter were measured at 16 sites in Cleveland, OH over a 1 year period during 1971 and 1972 (45 to 50 sampling days). Analytical methods used included instrumental neutron activation, emission spectroscopy, and combustion techniques. Uncertainties in the concentrations associated with the sampling procedures, the analytical methods, the use of several analytical facilities, and samples with concentrations below the detection limits are evaluated in detail. The data are discussed in relation to other studies and source origins. The trace constituent concentrations as a function of wind direction are used to suggest a practical method for air pollution source identification.