Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ampere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

Electrolyte design for Li-ion batteries under extreme operating conditions

The ideal electrolyte for the widely used LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811)||graphite lithium-ion batteries is expected to have the capability of supporting higher voltages (≥4.5 volts), fast charging (≤15 minutes), charging/discharging over a wide temperature range (±60 degrees Celsius) without lithium plating, and non-flammability. No existing electrolyte simultaneously meets all these requirements and electrolyte design is hindered by the absence of an effective guiding principle that addresses the relationships between battery performance, solvation structure and solid-electrolyte-interphase chemistry. Here we report and validate an electrolyte design strategy based on a group of soft solvents that strikes a balance between weak Li+-solvent interactions, sufficient salt dissociation and desired electrochemistry to fulfil all the aforementioned requirements. Remarkably, the 4.5-volt NMC811||graphite coin cells with areal capacities of more than 2.5 milliampere hours per square centimetre retain 75 per cent (54 per cent) of their room-temperature capacity when these cells are charged and discharged at -50 degrees Celsius (-60 degrees Celsius) at a C rate of 0.1C, and the NMC811||graphite pouch cells with lean electrolyte (2.5 grams per ampere hour) achieve stable cycling with an average Coulombic efficiency of more than 99.9 per cent at -30 degrees Celsius. The comprehensive analysis further reveals an impedance matching between the NMC811 cathode and the graphite anode owing to the formation of similar lithium-fluoride-rich interphases, thus effectively avoiding lithium plating at low temperatures. Additionally, this electrolyte design principle can be extended to other alkali-metal-ion batteries operating under extreme conditions.

25 ENERGY STORAGE↗

Validating and optimizing mismatch tolerance of Doppler backscattering measurements with the beam model (invited)

In this work, we use the beam model of Doppler backscattering (DBS), which was previously derived from beam tracing and the reciprocity theorem, to shed light on mismatch attenuation. This attenuation of the backscattered signal occurs when the wavevector of the probe beam’s electric field is not in the plane perpendicular to the magnetic field. Correcting for this effect is important for determining the amplitude of the actual density fluctuations. Previous preliminary comparisons between the model and Mega-Ampere Spherical Tokamak (MAST) plasmas were promising. In this work, we quantitatively account for this effect on DIII-D, a conventional tokamak. We compare the predicted and measured mismatch attenuation in various DIII-D, MAST, and MAST-U plasmas, showing that the beam model is applicable in a wide variety of situations. Finally, we performed a preliminary parameter sweep and found that the mismatch tolerance can be improved by optimizing the probe beam’s width and curvature at launch. This is potentially a design consideration for new DBS systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Design of a low frequency, density profile reflectometer system for the MAST-U spherical tokamak

Validated and accurate edge profiles (temperature, density, etc.) are vitally important to the Mega Ampere Spherical Tokamak Upgrade (MAST-U) divertor and confinement effort. Density profile reflectometry has the potential to significantly add to the measurement capabilities currently available on MAST-U (e.g., Thomson scattering and Langmuir probes). This work presents the diagnostic requirements, problems, and solutions facing profile reflectometry in spherical tokamaks and MAST-U in particular. Requirements include density measurements near zero electron density in the scrape off layer region, coverage for a broad range of MAST-U plasma parameters, high time (≤10 microseconds) and spatial resolutions (≤1 cm), reliability, and identification of the plasma start frequency.

Instruments & Instrumentation↗

Density limits as disruption forecasters for spherical tokamaks

Fusion power output from spherical tokamaks would benefit from increased confined plasma density, but there exists a limit on the density before confinement is lost and the plasma current is disrupted. This density limit has long been characterized by a simple, global Greenwald limit proportional to the plasma current and inversely proportional to the cross sectional area of the plasma. It is shown that in the database of discharges from the National Spherical Tokamak Experiment (NSTX) and Mega Ampere Spherical Tokamak (MAST) spherical tokamaks, the likelihood of disruption does increase above the Greenwald limit, and especially in the plasma current rampdown phase. The physics of the density limit has been recently theoretically explored through local criteria. Several of these are tested using the disruption event characterization and forecasting (DECAF TM ) code for their potential effectiveness as disruption warning signals. For a limited set of NSTX discharges, a local island power balance criteria was found to be less reliable, presently, than the Greenwald limit. For this work, an empirical critical edge line density and a boundary turbulent transport limit were both tested for MAST-U, which has an electron density profile measurement with high spatial resolution in the outer part of the plasma. Both were found to have similar dependencies on key plasma parameters. In a limited set of MAST-U discharges that appear to disrupt due to rising density at values under the Greenwald limit, crossing of the boundary turbulent transport limit occurred close to the time of disruption. Finally, these limits were evaluated for their potential use in real-time, and it was found that with the necessary real-time inputs and with refinement through further testing, these limits could be implemented in a real-time disruption forecasting system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A review of collaborative studies between the NSTX/-U and MAST/-U spherical tokamaks

The National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory in the United States, and the mega ampere spherical tokamak (MAST) at the United Kingdom Atomic Energy Authority in the United Kingdom, and their respective upgrades (NSTX-U and MAST-U) are two MAST fusion devices that have operated roughly over the past two decades. Both devices have made significant contributions to understanding spherical tokamak (ST) plasma physics, and fusion plasmas in general, and both have contributed data to multi-machine database studies. Several diagnostics have been physically moved from one machine to the other by diagnostic teams working on both devices. Collaboration has benefited both research teams in the areas of operational expertise, scenario development, and equilibrium reconstruction techniques. More focused comparative studies between the two devices have been pursued over the years in many areas as well, including stability calculations, disruption characterization, pedestal and edge localized mode stability, confinement and transport, energetic particles, and heating and current drive modelling. Together NSTX/-U and MAST/-U set the stage for the future of STs, which is entering the phase of design of demonstration power plant devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of resistive peeling–ballooning modes across spherical tokamaks

We investigate how non-ideal-magnetohydrodynamics (MHD) effects, in particular plasma resistivity, impact the peeling–ballooning stability thresholds in spherical tokamaks. This analysis follows the discovery of resistive kink-peeling modes in ELMing National Spherical Torus Experiment (NSTX) discharges. In the present study we extend this modeling to ELMing pulses in the Mega Ampere Spherical Tokamak (MAST) and MAST—Upgrade (MAST-U), where we find a clear resistive scaling for peeling–ballooning modes. While in NSTX ideal-MHD predicts stability for ELMing discharges, in MAST-U we find that the plasma is slightly unstable to peeling–ballooning modes, but is fully stabilized once diamagnetic effects are considered in terms of a growth rate normalization. A resistive power law scaling is calculated for these modes on MAST-U, which lies in between that of tearing modes and resistive interchange modes. A comparison between M3D-C1 and NIMROD shows reasonable agreement for this scaling. Resistivity destabilizes the modes and the peeling–ballooning unstable domain is considerably expanded in both, MAST and MAST-U. In addition to the MAST/-U pulses we also analyze resistive PB stability in a NSTX-similarity discharge on DIII-D. While having a different aspect ratio from NSTX, this discharge uses NSTX-like shaping parameters, toroidal field and plasma current. By considering these discharges alongside NSTX cases, we identify conditions influencing the onset of resistive peeling–ballooning modes. Furthermore, our findings indicate that magnetic shear in the pedestal region is closely linked to the emergence of resistive edge modes.

MAST-U↗

Polarization and phase control of electron injection and acceleration in the plasma by a self-steepening laser pulse

Abstract We describe an interplay between two injection mechanism of background electrons into an evolving plasma bubble behind an intense laser pulse: one due to the overall bubble expansion, and another due to its periodic undulation. The two mechanisms occur simultaneously when an intense laser pulse propagating inside a plasma forms a shock-like steepened front. Periodic undulations of the plasma bubble along the laser propagation path can either inhibit or conspire with electron injection due to bubble expansion. We show that carrier-envelope-phase (CEP) controlled plasma bubble undulation induced by the self-steepening laser pulse produces a unique electron injector—expanding phase-controlled undulating bubble (EPUB). The longitudinal structure of the electron bunch injected by the EPUB can be controlled by laser polarization and power, resulting in high-charge (multiple nano-Coulombs) high-current (tens of kilo-amperes) electron beams with ultra-short (femtosecond-scale) temporal structure. Generation of high-energy betatron radiation with polarization- and CEP-controlled energy spectrum and angular distribution is analyzed as a promising application of EPUB-produced beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dyson maps and unitary evolution for Maxwell equations in tensor dielectric media

The propagation and scattering of electromagnetic waves in dielectric media is of theoretical and experimental interest in a wide variety of fields. An understanding of observational results generally requires a numerical solution of Maxwell equations—usually implemented on conventional computers using sophisticated numerical algorithms. In recent years, advances in quantum information science and in the development of quantum computers have piqued curiosity about taking advantage of these resources for an alternate numerical approach to Maxwell equations. This requires a reformulation of the classical Maxwell equations into a form suitable for quantum computers which, unlike conventional computers, are limited to unitary operations. In this paper, a unitary framework is developed for the propagation of electromagnetic waves in a spatially inhomogeneous, passive, nondispersive, and anisotropic dielectric medium. For such a medium, generally, the evolution operator in the combined Faraday-Ampere equations is not unitary. There are two steps needed to convert this equation into a unitary evolution equation. In the first step, a weighted Hilbert space is formulated in which the generator of dynamics is a pseudo-Hermitian operator. In the second step, a Dyson map is constructed which maps the weighted-physical-Hilbert space to the original Hilbert space. Furthermore, the resulting evolution equation for the electromagnetic wave fields is unitary. Utilizing the framework developed in these steps, a unitary evolution equation is derived for electromagnetic wave propagation in a uniaxial dielectric medium. The resulting form is suitable for quantum computing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Runaway electron current reconstitution after a nonaxisymmetric magnetohydrodynamic flush

Benign termination of mega-ampere (MA) level runaway current has been convincingly demonstrated in recent JET and DIII-D experiments, establishing it as a leading candidate for runaway mitigation on ITER. This comes in the form of a runaway flush by parallel streaming loss along stochastic magnetic field lines formed by global magnetohydrodynamic instabilities, which are found to correlate with a low-Z injection that purges the high-Z impurities from a post-thermal-quench plasma. Here, in this study, we show the competing physics that govern the postflush reconstitution of the runaway current in an ITER-like reactor where significantly higher current is expected. The trapped “runaways” are found to dominate the seeding for runaway reconstitution, and the incomplete purge of high-Z impurities helps drain the seed but produces a more efficient avalanche, two of which compete to produce a 2–3 MA step in current drop before runaway reconstitution of the plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating performance and portability of high-level programming models: Julia, Python/Numba, and Kokkos on exascale nodes

We explore the performance and portability of the high-level programming models: the LLVM-based Julia and Python/Numba, and Kokkos on high-performance computing (HPC) nodes: AMD Epyc CPUs and MI250X graphical processing units (GPUs) on Frontier’s test bed Crusher system and Ampere’s Arm-based CPUs and NVIDIA’s A100 GPUs on the Wombat system at the Oak Ridge Leadership Computing Facilities. We compare the default performance of a hand-rolled dense matrix multiplication algorithm on CPUs against vendor-compiled C/OpenMP implementations, and on each GPU against CUDA and HIP. Rather than focusing on the kernel optimization per-se, we select this naive approach to resemble exploratory work in science and as a lower-bound for performance to isolate the effect of each programming model. Julia and Kokkos perform comparably with C/OpenMP on CPUs, while Julia implementations are competitive with CUDA and HIP on GPUs. Performance gaps are identified on NVIDIA A100 GPUs for Julia’s single precision and Kokkos, and for Python/Numba in all scenarios. We also comment on half-precision support, productivity, performance portability metrics, and platform readiness. We expect to contribute to the understanding and direction for high-level, high-productivity languages in HPC as the first-generation exascale systems are deployed.

Godoy, William↗

Engineering Design of D1/D3 Dipole Magnets for the Electron-Ion Collider (EIC)

Here, the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 10 34 cm −2 s −1 . An electron storage ring (ESR) will be installed in the existing Relativistic Heavy Ion Collider (RHIC) tunnel and will store polarized electron beams from 5 to 18 GeV. The ESR will have 750 dipole magnets with varying field requirements, including 576 super-bend triplets consisting of two magnets D1/D3 and D2. This paper presents on the engineering design of the D1/D3 dipole magnets within the arcs, with special focus on the coil design that allows the magnet to be configured for variable ampere-turns per energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electro-physical properties of surface-barrier diodes on low-resistance n-Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 crystals

The electro-physical properties of Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 n-type conductivity single crystals with relatively low resistivity were studied. The determined resistivity of semiconductor single crystals Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 n-type conductivity is equal to ρ≈2 Ω-cm at 293K. The activation energy of dark conductivity, measured from the temperature dependence of the resistivity of the In/Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 /In structure, is equal to ΔE≈0.11eV. From optical measurements of the absorption coefficient from the energy of photons in the region of large α, the band-gap width of the single crystal was found, which is equal to E g =1.53eV. Diode structures of Ni/Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 /In obtained by vacuum sputtering of Ni on the surface of a single crystal n-Cd 0.96 Mn 0.04 Te 0.96 Se 0.04 were manufactured and studied. Here, the rectification coefficient at a voltage of U=1V is equal to 10 8 . Within the framework of the Sah-Noys-Shockley carrier generation-recombination model, a quantitative match of the experimental measurements of the volt-ampere characteristics with the calculation was achieved.

(Cd,Mn)(Te,Se)↗

Redesigning protonic ceramic electrochemical cells to lower the operating temperature

Protonic ceramic electrochemical cells (PCECs) can operate at intermediate temperatures (450° to 600°C) for power generation and hydrogen production. However, the operating temperature is still too high to revolutionize ceramic electrochemical cell technology. Lowering the operating temperature to <450°C will enable a wider material choice and reduce system costs. We present approaches to redesigning PCECs via readily fabricated single-grain–thick, chemically homogeneous, and robust electrolytes and a nano-micro positive electrode. At 450°C, the PCECs achieve a peak power density of 1.6 watt per square centimeter on H 2 fuel, 0.5 watt per square centimeter on NH 3 fuel, and 0.3 watt per square centimeter on CH 4 fuel in fuel cell mode. In steam electrolysis mode, a current density of >0.6 ampere per square centimeter with a Faradaic efficiency of >90% is achievable at 1.4 volt and 400°C. In addition, exceptional durability (>2000 hours) has been demonstrated, with a degradation rate of <0.01 millivolt per 100 hours in fuel cell mode at 400°C.

Science & Technology - Other Topics↗