Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alarms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Alarms Philosophy

An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits. In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.

alarms↗

Remote Monitor Alarm System

A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

Stute, Robert A.↗

Unstated assumptions in alarm management - 202

Alarm management in the process industries has been an increasing area of activity since the first publications of EEMUA 191 in 1999 and ISA18.2 in 2008. Most major oil and chemical companies have adopted some or all of the metrics for alarm management presented in these documents. However, simply targeting for these metrics might not be the best course of action for a company. Many of the metrics involve assumptions or logic not explicitly stated in the guidelines, assumptions that might not be valid for a given console or plant. In other cases, metrics are the result of implied, rather than explicit, relationships between alarm guidelines. Again, the implied connection might not be true under certain circumstances. Understanding these unstated underpinnings of alarm management can facilitate the implementation of a useful and efficient alarm management program. This paper explores some of the key unstated assumptions in alarm management and how changes in those assumptions can alter both the interpretation of alarm metrics as well as what metrics are utilized. (authors)

47 OTHER INSTRUMENTATION↗

Analysis and Recommendation of Alpha-Beta Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) alpha-beta continuous air monitor (CAM) is used for real-time detection of “artificial” alpha-beta particulates from the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory—called the “PNNL OS3300 Alpha-Beta Monitoring Software”—that provides real-time estimates of alpha-beta air concentrations and integrated activities that are calculated from measured CAM counts. The OS3300 software has alarm setpoints that can be used to provide an early indication of larger releases, that if allowed to persist, could approach defined dose limits. This report performs a detailed review of historical and current alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios, meteorology, and adjustment factors used in estimating released stack activity. Based on the results, the alpha and beta air concentration alarm setpoints will remain 1.77 × 10 -8 µCi/ml and 3.47 × 10 -8 µCi/ml, respectively; and the alpha and beta integrated activity alarm setpoints will remain 70.22 µCi and 137.63 µCi, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned radiological work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are below defined and regulatory limits.

325RPL↗

Xcel Energy implements an alarm management strategy

Not so long ago, Xcel Energy's Pawnee Station, a 505 MW coal-fired generating station in Brush, Colorado, USA was commonly generating 300 to 400 alarms per 8-hour shift. The article describes how the alarm system was revised and improved by tackling alarm dead-bands, and rationalising alarms for routine events. Operators are trained to understand the functions of alarm management components, their use and response, and obtain feedback. Today the power station reports about one alarm per hour. 3 photos.

20 FOSSIL-FUELED POWER PLANTS↗

Incorporating realistic conservatism into criticality alarm placement and emergency response: a regulatory perspective - 14425

Review of historical process plant criticality accidents shows that their consequences vary widely and are extremely difficult to predict accurately. Because of the wide variability and inherent uncertainty in estimating consequences, criticality detector placement analysis and consequence estimation for emergency response typically utilize very conservative assumptions with regard to the total fissions, time-dependent fission rate, and intervening shielding. For detector placement, a 'minimum accident of concern' is typically defined, whereas emergency consequence evaluations typically define a maximum fission source term. These require different mindsets because what is conservative for one type of analysis may be non-conservative for the other. While some conservatism is commonly practiced in both cases, excessive conservatism can result in a net increase in risk, such as resulting from inadvertent alarm activations, that can be costly to operations and counterproductive to safety. Conversely, reliance on very detailed calculational models to reduce conservatism could increase the number and complexity of controls, such as shielding for dose mitigation. Deterministic regulatory criteria have also been applied for determining where criticality detectors are to be deployed and what areas must be evacuated in the event of an accident. This paper explores several issues associated with criticality alarm placement and emergency response from a regulatory perspective. This paper will discuss insights gained from historical fuel facility accidents and significant events regarding the inherent risk of criticality, the most likely locations for criticality to occur, and the most probable characteristics of a critical excursion. This will include discussion of the previously disputed relevance of the United States Nuclear Regulatory Commission's (USNRC's) longstanding model for a critical excursion. While USNRC regulations deterministically require dual alarm coverage in all areas having greater than a 'critical mass' of fissionable material, a process is provided to grant exemptions when a risk-informed argument is technically justified. Similar risk-informed considerations have been used to justify compensatory measures allowing limited operation during periods of alarm system outage due to component failure or maintenance. This paper will explore the application of risk information and performance history to address requirements for criticality alarm system coverage, granting exemptions from deterministic criteria, allowing compensatory measures during system outages, determining evacuation areas and routes, and assessing the significance associated with alarm system issues. Finally, the impact of shielding on the USNRC's regulatory risk basis and approved subcritical margin will be reviewed. (authors)

42 ENGINEERING↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning

Idaho National Laboratory (INL) has contracted IFE to support human factors research and the development of leading-edge technology to support control room operators as the U.S. fleet undergoes modernization and digitalization in legacy plants and control rooms. As the nuclear industry starts to shift to more digital controls and systems, these upgrades provide more information to the main control room in the form of digital signals and values. Also, an increase in the number of alarms points is provided by the vendors. New digital control rooms shift from main control boards to soft controls, and alarm panels to a single display. This change to a single display has created a problem of alarm waterfall, a situation in which the addition of new alarm points causes an overload of information to the operator during either a plant disturbance or other than normal full power operations. IFE’s goal is to find a workable solution to assist operators in both handling and understanding incoming alarms during emergency situations under these waterfall conditions.

99 GENERAL AND MISCELLANEOUS↗

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and Recommendation of Tritium Gas Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) tritium continuous air monitor (CAM) is used for near real-time detection of tritium gas (i.e., elemental tritium [HT] and tritiated water vapor [HTO]) in the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory (PNNL)—called the “PNNL OS3700 Tritium Monitoring Software”—that provides near real-time estimates of tritium gas air concentrations and integrated daily activities that are calculated from measured CAM counts. The OS3700 software implements alarm setpoints to alert the facility of larger tritium gas releases that if allowed to persist, could begin to challenge permitted emission and established dose constraints. This report performs a detailed review of historical and current tritium alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios and meteorology. Based on the results, the tritium air concentration and integrated daily tritium activity alarm setpoints will remain 2.0 × 10 -5 µCi/ml and 25 Ci/day, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned tritium work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are well below defined and regulatory limits.

325RPL↗

Soda Pop: A Time-Series Clustering, Alarming and Disease Forecasting Application

To introduce Soda Pop, an R/Shiny application designed to be a disease agnostic time-series clustering, alarming, and forecasting tool to assist in disease surveillance “triage, analysis and reporting” workflows within the Biosurveillance Ecosystem (BSVE). In this poster, we highlight the new capabilities that are brought to the BSVE by Soda Pop with an emphasis on the impact of methodological decisions. The Biosurveillance Ecosystem (BSVE) is a biological and chemical threat surveillance system sponsored by the Defense Threat Reduction Agency (DTRA). BSVE is intended to be user-friendly, multi-agency, cooperative, modular and threat agnostic platform for biosurveillance. In BSVE, a web-based workbench presents the analyst with applications (apps) developed by various DTRA funded researchers, which are deployed on-demand in the cloud(e.g., Amazon Web Services). These apps aim to address emerging needs and refine capabilities to enable early warning of chemical and biological threats for multiple users across local, state, and federal agencies. Soda Pop is an app developed by Pacific Northwest National Laboratory (PNNL) to meet the current needs of the BSVE for early warning and detection of disease outbreaks. Aimed for use bya diverse set of analysts, the application is agnostic to data source and spatial scale enabling it to be generalizable across many diseases and locations. To achieve this, we placed a particular emphasis on clustering and alerting of disease signals within Soda Pop without strong prior assumptions on the nature of observed diseased counts. Although designed to be agnostic to the data source, Soda Pop was initially developed and tested on data summarizing Influenza-Like Illness in military hospitals from collaboration with the Armed Forces Health Surveillance Branch. Currently, the data incorporated also includes the CDC’s National Notifiable Diseases Surveillance System(NNDSS) tables and the WHO’s Influenza A/B Influenza Data(Flunet). These data sources are now present in BSVE’s Postgres data storage for direct access. Soda Pop is designed to automate time-series tasks of data summarization, exploration, clustering, alarming and forecasting. Built as an R/Shiny application, Soda Pop is founded on the powerful statistical tool R.. Where applicable, Soda Pop facilitates nonparametric seasonal decomposition of time-series; hierarchical agglomerative clustering across reporting areas and between diseases within reporting areas; and a variety of alarming techniques including Exponential Weighted Moving Average alarms and Early Aberration Detection. Soda Pop embeds these techniques within a user-interface designed to enhance an analyst’s understanding of emerging trends in their data and enables the inclusion of its graphical elements into their dossier for further tracking and reporting. The ultimate goal of this software is to facilitate the discovery of unknown disease signals along with increasing the speed of detection of unusual patterns within these signals. Soda Pop organizes common statistical disease surveillance tasks in a manner integrated with BSVE data source inputs and outputs. The app analyzes time-series disease data and supports a robust set of clustering and alarming routines that avoid strong assumptions on the nature of observed disease counts. This attribute allows for flexibility in the data source, spatial scale, and disease types making it useful to a wide range of analysts.

97 MATHEMATICS AND COMPUTING↗

Methods for Detector Placement and Analysis of Criticality Accident Alarm Systems

Determining the optimum placement to minimize the number of detectors for a criticality accident alarm system (CAAS) in a large manufacturing facility is a complex problem. There is typically a target for the number of detectors that can be used over a given zone of the facility. A study to optimize detector placement typically begins with some initial guess at the placement of the detectors and is followed by either predictive calculations of accidents at specific locations or adjoint calculations based on preferred detector locations. Within an area of a facility, there may be a large number of potential criticality accident sites. For any given placement of the detectors, the list of accident sites can be reduced to a smaller number of locations at which accidents may be difficult for detectors to detect. Developing the initial detector placement and determining the list of difficult accident locations are both based on the practitioner's experience. Simulations following fission particles released from an accident location are called 'forward calculations.' These calculations can be used to answer the question 'where would an alarm be triggered?' by an accident at a specified location. Conversely, 'adjoint calculations' start at a detector site using the detector response function as a source and essentially run in reverse. These calculations can be used to answer the question 'where would an accident be detected?' by a specified detector location. If the number of accidents, P, is much less than the number of detectors, Q, then forward simulations may be more convenient and less time-consuming. If Q is large or the detectors are not placed yet, then a mesh tally of dose observed by a detector at any location must be computed over the entire zone. If Q is much less than P, then adjoint calculations may be more efficient. Adjoint calculations employing a mesh tally can be even more advantageous because they do not rely on a list of specific difficult-to-detect accident sites, which may not have included every possible accident location. Analog calculations (no biasing) simply follow particles naturally. For sparse buildings and line-of-sight calculations, analog Monte Carlo (MC) may be adequate. For buildings with internal walls or large amounts of heavy equipment (dense geometry), variance reduction may be required. Calculations employing the CADIS method use a deterministic calculation to create an importance map and a matching biased source distribution that optimize the final MC to quickly calculate one specific tally. Calculations employing the FW-CADIS method use two deterministic calculations (one forward and one adjoint) to create an importance map and a matching biased source distribution that are designed to make the MC calculate a mesh tally with more uniform uncertainties in both high-dose and low-dose areas. Depending on the geometry of the problem, the number of detectors, and the number of accident sites, different approaches to CAAS placement studies can be taken. These are summarized in Table I. SCALE 6.1 contains the MAVRIC sequence, which can be used to perform any of the forward-based approaches outlined in Table I. For analog calculations, MAVRIC simply calls the Monaco MC code. For CADIS and FW-CADIS, MAVRIC uses the Denovo discrete ordinates (SN) deterministic code to generate the importance map and biased source used by Monaco. An adjoint capability is currently being added to Monaco and should be available in the next release of SCALE. An adjoint-based approach could be performed with Denovo alone - although fine meshes, large amounts of memory, and long computation times may be required to obtain accurate solutions. Coarse-mesh SN simulations could be employed for adjoint-based scoping studies until the adjoint capability in Monaco is complete. CAAS placement studies, especially those dealing with mesh tallies, require some extra utilities to aid in the analysis. Detectors must receive a minimum dose rate in order to alarm; therefore, a simple yes/no plot could be more useful to the analyst than a standard dose rate contour plot. Alarm systems that require several detectors to alarm simultaneously for a given accident would need to combine several yes/no plots in order to show accident sites where multiple detectors would be triggered. This could require a plot of 'areas of coverage' that is mapped over the building geometry. Several new utilities (which will be part of SCALE 6.2) were created to help with CAAS analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Monitoring techniques and alarm procedures for CMS services and sites in WLCG

The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

Molina-Perez, J.↗

Container with expiration date alarm

A container assembly with an expiration date alarm that preserves its battery life by only triggering its alarm when needed. The container assembly includes a container for enclosing a food item, medication, or other product that should not be used after an expiration date; a sensor for sensing when the container has been opened; an alarm; and a timing circuit coupled with the sensor and the alarm for triggering the alarm only if the container is opened after the expiration date has been reached.

42 ENGINEERING↗

A Human Factors Perspective on Alarm System Research and Development 2000 to 2010

By definition, alarms serve to notify human operators of out-of-parameter conditions that could threaten equipment, the environment, product quality and, of course, human life. Given the complexities of industrial systems, human machine interfaces, and the human operator, the understanding of how alarms and humans can best work together to prevent disaster is continually developing. This review examines advances in alarm research and development from 2000 to 2010 and includes the writings of trade professionals, engineering and human factors researchers, and standards organizations with the goal of documenting advances in alarms system design, research, and implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗