Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air-source heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

ComStock Measure Scenario Documentation: Reduced Thermostat Setbacks for Heat Pumps

This report provides documentation of a measure for the End Use Savings Shapes project, which consists of analysis of different energy efficiency and renewable energy measures on the commercial building stock, using NREL's ComStock tool. The measure consists of a reduction in thermostat setbacks for air-source heat pump RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Assessing the behavioral realism of energy system models in light of the consumer adoption literature

Effective policymaking to achieve net zero greenhouse gas emissions demands an understanding of the complex drivers of, and barriers to, consumer adoption behavior via behaviorally realistic energy system models. Existing models tend to oversimplify by focusing on homogenized financial factors while neglecting consumer heterogeneity and non-monetary influences. This study develops and applies a comprehensive framework for evaluating the behavioral realism of consumer adoption models, informed by the adoption literature. It introduces a typology for factors influencing low-carbon technology adoption decisions: monetary and non-monetary factors relating to household characteristics, psychology, technological attributes, and contextual conditions. Next, reviews of the consumer adoption and decision-making literature identify the most influential adoption factor categories for distributed solar photovoltaics, electric vehicles, and air-source heat pumps. Finally, the extent to which a selection of energy system models accounts for these adoption factors is assessed. Existing models predominantly emphasize the economic aspects of technology, which are generally identified as the most important factors. Where the models fall short — in considering moderately important factor categories — sector-specific and agent-based models can offer more behaviorally realistic insights. This study sheds light on which types of factors are most important for consumer adoption decisions and investigates how well current models rise to the challenge of behavioral realism. The end-to-end analysis presented enables internally consistent comparisons across models and energy technologies. This research advances timely conversations on consumer adoption. It could inform more behaviorally realistic energy system modeling, and thereby more effective decarbonization policymaking.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

REopt Federal User Support Session Two

This presentation is for FEMP's second user support session for federal REopt users. These sessions cover topics such as: overviews of REopt capabilities, hands-on REopt trainings and demonstrations, discussion and feedback about the tool and user support, federal REopt case studies and success stories, and links to REopt resources. This particular session covers discussion about federal onsite energy projects and challenges, using REopt to evaluate air-source and geothermal heat pumps, a federal success story about using REopt for heat pump analysis, a summary of available resources, and open question and answer session.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗