Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “activity measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Balloon-based interferometric techniques

A balloon-borne triple-etalon Fabry-Perot Interferometer, observing the Doppler shifts of absorption lines caused by molecular oxygen and water vapor in the far red/near infrared spectrum of backscattered sunlight, has been used to evaluate a passive spaceborne remote sensing technique for measuring winds in the troposphere and stratosphere. There have been two successful high altitude balloon flights of the prototype UCL instrument from the National Scientific Balloon Facility at Palestine, TE (May 80, Oct. 83). The results from these flights have demonstrated that an interferometer with adequate resolution, stability and sensitivity can be built. The wind data are of comparable quality to those obtained from operational techniques (balloon and rocket sonde, cloud-top drift analysis, and from the gradient wind analysis of satellite radiance measurements). However, the interferometric data can provide a regular global grid, over a height range from 5 to 50 km in regions of clear air. Between the middle troposphere (5 km) and the upper stratosphere (40 to 50 km), an optimized instrument can make wind measurements over the daylit hemisphere with an accuracy of about 3 to 5 m/sec (2 sigma). It is possible to obtain full height profiles between altitudes of 5 and 50 km, with 4 km height resolution, and a spatial resolution of about 200 km, along the orbit track. Below an altitude of about 10 km, Fraunhofer lines of solar origin are possible targets of the Doppler wind analysis. Above an altitude of 50 km, the weakness of the backscattered solar spectrum (decreasing air density) is coupled with the low absorption crosssection of all atmospheric species in the spectral region up to 800 nm (where imaging photon detectors can be used), causing the along-the-track resolution (or error) to increase beyond values useful for operational purposes. Within the region of optimum performance (5 to 50 km), however, the technique is a valuable potential complement to existing wind measuring systems and can provide a low cost addition to powerful active (LIDAR) wind measuring systems now under development.

Rees, David↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

Outline for Feasibility Study on a Nuclear Material Accounting and Control System for Measurement of High-Activity Waste at Tokai Reprocessing Plant during Decommissioning

The objective of this collaboration between the DOE/NNSA International Nuclear Security Program (INS) and JAEA is to conduct a feasibility study on nuclear material accounting and control needs and requirements for NDA measurement of high-activity waste at TRP during the decommissioning process. Under this study, both sides will exchange information, perform an assessment of needs and requirements, and develop joint recommendations for development of the A-HMMS.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Active microwave investigation of snowpacks: Experimental documentation, Colorado 1979-1980

During the winter of 1979-1980, the University of Kansas Microwave Active Spectrometer systems measured the backscattering properties of snowpacks under varying conditions at four test sites in Colorado. In addition to the radar data over 1-35 GHz, ground-truth measurements of the atmospheric, snow, and soil characteristics were obtained for each radar data set. The test sites, data acquisition procedures, and data that were acquired in this experiment are presented and described.

Stiles, W. H.↗

Utilizing Advanced Statistics to Determine Anomalistic Conditions in Pebble-Bed Reactors

Pebble-bed reactors (PBRs) utilize hundreds of thousands of fuel pebbles, which continuously circulate through the core, in lieu of traditional fuel assemblies to generate fissions and produce power. The use of unmarked fuel pebbles presents a challenge for international safeguards verification that nuclear material is not being diverted. To ensure pebble diversion is not taking place, new methods for accounting for and monitoring the pebbles should be examined to determine an appropriate methodology for performing bulk accountancy with pebbles. Here, this work examines the use of statistical methods for determining if the reactor is within a declared range of operation by examining the statistical distribution of pebble burnup as they are discharged from the core. Using this methodology, we created a model that detects diversion over 95% of the time, over multiple diversion pathways, if the reactor core maintains a constant power density during the diversion process and only falsely labels a diversion case nominal 2% of the time. For a diversion scenario where the reactor is maintained at a constant power, the statistical analysis can correctly identify if diversion is occurring over 80% of the time; however, nearly 20% of specific diversion pathways are mislabeled nominal. These results provide a basis and framework for exploring the further use of statistical methods to determine where these methods could be most useful and where additional methods, such as machine learning, could be used to capture if diversion is occurring in pebble-bed reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automatic Phasing for Active Antenna Elements

Automatic phasing system periodically interrupts antenna operation for calibration intervals and measures phase and amplitude response at each active antenna element. Using these measurements, system adjusts phase shift and possibly gain of active elements during operating intervals to give desired antenna-gain pattern.

Wu, C.↗

Thermodynamic Effect of Platinum Addition to beta-NiAl: An Initial Investigation

An initial investigation was conducted to determine the effect of platinum addition on the activities of aluminum and nickel in beta-NiAl(Pt) over the temperature range 1354 to 1692 K. These measurements were made with a multiple effusion-cell configured mass spectrometer (multi-cell KEMS). The results of this study show that Pt additions act to decreased alpha(Al) and increased the alpha(Ni) in beta-NiAl(Pt) for constant X(sub Ni)/X(sub Al) approx. = 1.13, while at constant X(sub Al) the affect of Pt on Al is greatly reduced. The measured partial enthalpies of mixing indicate Al-atoms have a strong self interaction while Ni- and Pt-atoms in have similar interactions with Al-atoms. Conversely the binding of Ni-atoms in beta-NiAl decreases with Pt addition independent of Al concentration. These initial results prove the technique can be applied to the Ni-Al-Pt system but more activity measurements are required to fully understand the thermodynamics of this system and how Pt additions improved the scaling behavior of nickel-based superalloys. In addition, with the choice of a suitable oxide material for the effusion-cell, the "closed" isothermal nature of the effusion-cell allows the direct investigation of an alloy-oxide equilibrium which resembles the "local-equilibrium" description of the metal-scale interface observed during high temperature oxidation. It is proposed that with an Al(l) + Al2O3(s) experimental reference state together with the route measurement of the relative partial-pressures of Al(g) and Al2O(g) allows the activities of O and Al2O3 to be determined along with the activities of Ni and Al. These measurements provide a direct method of investigating the thermodynamics of the metal-scale interface of a TGO-scale.

Source record↗

Equipment Development for Automatic Anthropometric Measurements

An automated procedure for measuring and recording the anthropometric active angles is presented. The small portable system consists of a microprocessor controlled video data acquisition system which measures single plane active angles using television video techniques and provides the measured data on sponsored-specified preformatted data sheets. This system, using only a single video camera, observes the end limits of the movement of a pair of separated lamps and calculates the vector angle between the extreme positions.

Cater, J. P.↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

SiO2 Activity Measurements in the Gd2O3-SiO2 System Via Knudsen Effusion Mass Spectrometry (KEMS)

Environmental barrier coatings (EBCs) are required for the use of silicon carbide (SiC)-based ceramic matrix composites (CMCs) in gas turbine engines, as they protect the SiO 2 thermally grown oxide (TGO) formed at the CMC/coating interface from volatilization in a combustion environment. Current-generation EBCs consist of a silicon bond coat and a rare earth (RE) silicate topcoat. The RE silicate topcoat is exposed to high-velocity steam during engine operation, and SiO 2 within the coating can preferentially volatilize to form Si(OH) 4 gas species, albeit at a lesser degree than SiO 2 alone. Therefore, it is of interest to investigate the stability of these materials in steam as a function of their RE. In this study, SiO 2 activity, which can be related to the partial pressure of Si(OH) 4 , was measured across the Gd 2 O 3 -SiO 2 phase diagram, which includes Gd 2 SiO 5 , Gd 9.33 (SiO 4 ) 6 O 2 , and Gd 2 Si 2 O 7 as line compounds, via Knudsen Effusion Mass Spectrometry (KEMS). Values obtained for the Gd 2 O 3 -SiO 2 system were compared to those of other RE2O3-SiO2 systems and contextualized in terms of EBC viability.

EBCs↗

Structural Alignment Sensor Feasibility Demonstration

A structural alignment sensor (SAS) was developed for use with large deployable antenna systems for contour measurement and/or active control. The SAS is a laser ranging system using frequency modulation and accurate phase measurement to determine distance. Work was done with a CO2 and HeNe laser. The capability of the SAS to measure antenna rib contours was studied over ranges of 50 meters to a resolution of 100 microns. Initial resolution data was taken with the CO2 system. This data shows that it will indeed meet the SAS requirements. The development of the HeNe system was initiated because it offers substantial improvement in size, weight, and power over the CO2 system. The final demonstration was made with the HeNe system and it too showed that the SAS requirements could be met with this alternate approach. The projection of these results to a conceptual design for a flight system and its application are described.

Anderson, R. H.↗

Verification of static rotor-load measurement capabilities of the RSRA helicopter active-isolator system

The Rotor Systems Research Aircraft helicopter technology demonstration test bed incorporates an active isolator system which reduces the rotor vibrations that are transmitted to the airframe and allows the simultaneous measurement of all six forces and moments generated by the rotor. The first full system calibration was performed in 1983 to verify the system's static load measurement capabilities; the analysis of the data encompassed multiple linear regressions to determine calibration matrices for different data sets, and a hysteresis removal algorithm for the estimation of in-flight measurement errors. The results obtained indicate that the active isolator system meets most performance predictions.

Acree, C. W., Jr.↗

High-Reynolds Number Active Blowing Semi-Span Force Measurement System Development

Recent wind-tunnel tests at the NASA Langley Research Center National Transonic Facility utilized high-pressure bellows to route air to the model for evaluating aircraft circulation control. The introduction of these bellows within the Sidewall Model Support System significantly impacted the performance of the external sidewall mounted semi-span balance. As a result of this impact on the semi-span balance measurement performance, it became apparent that a new capability needed to be built into the National Transonic Facility s infrastructure to allow for performing pressure tare calibrations on the balance in order to properly characterize its performance under the influence of static bellows pressure tare loads and bellows thermal effects. The objective of this study was to design both mechanical calibration hardware and an experimental calibration design that can be employed at the facility in order to efficiently and precisely perform the necessary loadings in order to characterize the semi-span balance under the influence of multiple calibration factors (balance forces/moments and bellows pressure/temperature). Using statistical design of experiments, an experimental design was developed allowing for strategically characterizing the behavior of the semi-span balance for use in circulation control and propulsion-type flow control testing at the National Transonic Facility.

Lynn, Keith C.↗

Component Activity Measurements in the Ti-Al-O System by Knudsen Cell Mass Spectrometry

Titanium-aluminides (containing (alpha)2-Ti3Al and gamma-TiAl intermetallic phases) have received continued research focus due to their potential as low-density materials for structural applications at intermediate temperatures. However their application above about 850C is hindered by poor oxidation resistance, characterized by the formation of a non-protective TiO2+Al2O3 scale and an oxygen-enriched subsurface zone. Consistent with this are measured titanium and aluminum activities in "oxygen-free" titanium-aluminides, which indicate Al2O3 is only stable for aluminum concentrations greater then 54 atom percent at 1373 K. However, the inability to form a protective Al2O3 scale is in apparent conflict with phase diagram studies, as experimental isothermal sections of the Ti-Al-O system show gamma-TiAl + alpha2-Ti3Al structures are in equilibrium only with Al2O3. The apparent resolution to this conflict lies in the inclusion of oxygen effects in the thermodynamic measurements

Copland, Evan↗

Radio continuum and X-ray properties of the coronae of RS Canum Venaticorum and related active binary systems

Data from circular polarization measurements are reported which yield radio-continuum and X-ray characterizations of the coronae of active binaries including RS CVn. The circular polarization measurements are taken at 6 cm for 28 binary systems detected at flux densities of more than 0.7 mJy, and the data are examined in conjunction with those by Drake et al. (1989). Optical positions are derived for 8 RS CVn objects, three previous detections are confirmed, and seven sources are shown to have circular polarization at levels of 2-13 percent. A total of 49 X-ray sources are confirmed in a total of 190 positions, and the correlation between X-ray and radio emissions is analyzed. No observational evidence exists to support the notion that radio and X-ray emissions are due to nonthermal electrons, and the data provide evidence for and against thermal gyrosynchrotron radio emission.

Drake, Stephen A.↗

Laser Doppler And Range Systems For Spacecraft

Report discusses two types of proposed laser systems containing active transponders measuring distance (range) and line-of-sight velocity (via Doppler effect) between deep space vehicle and earth-orbiting satellite. Laser system offers diffraction advantage over microwave system. Delivers comparable power to distant receiver while using smaller transmitting and receiving antennas and less-powerful transmitter. Less subject to phase scintillations caused by passage through such inhomogeneous media as solar corona. One type of system called "incoherent" because range and Doppler measurements do not require coherence with laser carrier signals. Other type of system called "coherent" because successful operation requires coherent tracking of laser signals.

Kinman, P. W.↗

Metrology: Calibration and measurement processes guidelines

The guide is intended as a resource to aid engineers and systems contracts in the design, implementation, and operation of metrology, calibration, and measurement systems, and to assist NASA personnel in the uniform evaluation of such systems supplied or operated by contractors. Methodologies and techniques acceptable in fulfilling metrology quality requirements for NASA programs are outlined. The measurement process is covered from a high level through more detailed discussions of key elements within the process, Emphasis is given to the flowdown of project requirements to measurement system requirements, then through the activities that will provide measurements with defined quality. In addition, innovations and techniques for error analysis, development of statistical measurement process control, optimization of calibration recall systems, and evaluation of measurement uncertainty are presented.

Castrup, Howard T.↗