Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Xray imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design of a Large Diffraction Grating Optical Assembly

The Advanced Radiographic Capability (ARC) is a diagnostic system in the National Ignition Facility (NIF) that will enable high-speed imaging of imploding targets in the NIF Target Chamber. NIF is a multi-billion dollar project to focus 192 laser beams onto a small target (approximately the size of a pencil eraser) to generate nuclear fusion. The complete ARC system is composed of approximately 80 modular large optical assemblies known as Line Replaceable Units (LRUs). The total estimated weight of the ARC optics alone is 16,000 lbs, with an average optic weight of 200 lbs. Key to the function and performance of ARC is an optical compressor, which uses diffraction gratings known as Grating LRUs to temporally compress a total of 8 laser beams. The resulting high-power beams are focused onto a back-lighter target to create high-energy xrays for imaging. These Grating LRUs are housed inside vacuum vessels called Compressor Vessels (Figures 1-5). There are a total of 32 Grating LRUs, 16 in each Compressor Vessel.

42 ENGINEERING↗

Fracture Intersections under Stress: Laboratory Data and Code [Data set]

The connectivity of natural and induced fractures governs the injection and withdrawal of fluids from subsurface reservoirs. Connectivity depends on intersections that control how fluids mix and move through the entire system. Here, we present data sets from 3D X-ray microscopy measurements of simple fracture networks under stress. 3D printing was used to create prismatic blocks that formed fracture networks composed of 2 orthogonal fractures. The network orientation was either "x" or "+" relative to an applied vertical stress. 3D data sets were collected for normal loads of 25, 100 and 200 Newtons for samples with fracture surfaces with either correlated or uncorrelated asperity distributions. The file contains data from the 12 samples analyzed along with an example code used to extract the intersection geometry. Additional experimental details can be found in the manuscript "Geologic Stress Modulates Fluid Mixing at Fracture Intersections" (10.1038/s43247-026-03525-9)and supplemental information to appear in Communications Earth & Environment in 2026.

02 PETROLEUM↗

X-ray Computed Tomography Imaging of Printed Circuit Boards

Nondestructive inspection of printed circuit boards (PCB) can be efficiently carried out with xray Computed Tomography (XCT). However, image artifacts can obscure some of the PCB details. As a demonstration of LLNL’s XCT capabilities, an internally-funded effort was recently executed that acquired XCT data for a PCB. These data were reconstructed with both traditional and physics-based iterative techniques to illustrate the use of advanced algorithms to reduce artifacts and thus improve image quality.

42 ENGINEERING↗

Eccentric needle motion effect on near-nozzle dynamics of diesel spray

Here, the eccentric needle motion has been regarded as an important cause of in-nozzle flow disturbances and hole-to-hole spray variations of modern fuel injectors. However, the experimental investigations on this subject have rarely been reported due to great difficulties in the direct measurements of eccentric needle motion and the flow characteristics of individual holes in an injection nozzle. In this study, the axial and eccentric needle motion and the ear-nozzle spray dynamics of 3-hole, 5-hole and 8-hole diesel injection nozzles were investigated in varied injection pressure conditions using an xray phase-contrast imaging technique. The eccentric needle motion and near-nozzle spray axial velocity showed temporal oscillations during the injection with different oscillation frequencies. The frequencies of these two oscillations were independent to the nozzle and injection pressure. To discuss the mutual dependency of these two oscillations, the time traces of the spray axial velocity were measured for individual holes. The results showed that the oscillation phase, frequency and amplitude of the spray axial velocity were almost identical for all holes, which indicated that the sac pressure variation rather than hole-to-hole flow variation can be the primary cause of the spray axial velocity oscillation by the eccentric needle motion. The adequacy of this consideration was thoroughly discussed using a mass balance model in the nozzle sac that predicted the sac pressure variation during an injection event.

42 ENGINEERING↗

3D deformation field throughout the interior of materials.

This report contains the one-year feasibility study for our three-year LDRD proposal that is aimed to develop an experimental technique to measure the 3D deformation fields inside a material body. In this feasibility study, we first apply Digital Volume Correlation (DVC) algorithm to pre-existing in-situ Xray Computed Tomography (XCT) image sets with pure rigid body translation. The calculated displacement field has very large random errors and low precision that are unacceptable. Then we enhance these tomography images by setting threshold of the intensity of each slice. DVC algorithm is able to obtain accurate deformation fields from these enhanced image sets and the deformation fields are consistent with the global mechanical loading that is applied to the specimen. Through this study, we prove that the internal markers inside the pre-existing tomography images of aluminum alloy can be enhanced and are suitable for DVC to calculate the deformation field throughout the material body.

Jin, Huiqing↗

Pink Spinel in Apollo Impact Melt Rock 68815: Implications for Mg-Suite Magmatism

Introduction: Magnesian rocks from the lunar highlands are collectively termed the Mg-suite. Characterized by high (>60) Mg# (molar 100×Mg/[Mg+Fe]) in mafic phases and calcic plagioclase, these rocks are plutonic to hypabyssal in origin, and include a range of bulk mineralogies such as troctolites, dunites, norites, gabbronorites, and spinel troctolites [1]. These Mg-suite lithologies have distinct trace element concentrations and ratios that differentiate them from other lunar rock types. These rocks are ancient, generally dated to between 4.5 and 4.1 Ga, although it is unknown if this represents the full range of Mg-suite ages [1–2]. Among the Mg-suite lithologies, the spinel troctolites are relatively rare, to date only found in polymict breccias [3]. Spinel troctolites, as their name suggests, consist of calcic plagioclase and forsteritic olivine, with minor amounts of spinel (MgAl2O4), ± pyroxene and cordierite [1,4]. This form of spinel is often called ‘pink’ spinel because of its appearance in thin section under plane polarized light (PPL; Fig. 1), due to minor amounts of Cr. Spinel troctolites are generally plutonic or hypabyssal in origin (subsequently exhumed and incorporated into polymict breccias), or formed through impact processes (e.g., crystalline impact melt) [5]. A spinel-rich lithology has also been found in the Moscoviense region of the Moon via the Moon Mineralogy Mapper (M3) and lacks other mafic phases [6]. Finally, while the Mg-suite sampled thus far consists of plutonic (or hypabyssal) rocks, the question remains if such magmas could have erupted on the surface of the Moon [7]. These magmas have much lower density than mare basalts, but little sample or remote sensing evidence has been found to support the idea that extrusive Mg-suite volcanism occurred [7]. Here, we present a coordinated microanalytical study of spinel-bearing lithic and mineral clasts found in Apollo sample 68815. These data will be used to understand their petrogenesis (magmatic or impact) and modification histories, and to shed light on the existence of volcanic Mg-suite rocks. Sample Description: Apollo sample 68815 is a polymict impact melt breccia containing a variety of lithic and mineral fragments embedded in devitrified impact melt. This sample was chipped off the top of a boulder at Station 8 during the Apollo 16 mission and had an original weight of nearly 1.8 kg. In this study, we investigated two polished thin sections of 68815: 68815,17 and 68815,148, both containing spinel. Methods: The thin sections of 68815 were studied using optical light microscopy (PPL, cross-polarized light, and reflected light) with a Keyence VHX-7100 Digital Microscope. Each section was then X-ray mapped for 13–14 elements using a Cameca SX100 electron probe microanalyzer (EPMA) located in the Kuiper Materials Imaging and Characterization Facility (KMICF) at the University of Arizona. We have obtained geochemical information about the phases (olivine, plagioclase, spinel, pyroxene) in the thin sections also using the EPMA. In addition, we have used ThermoScientific Helios NanoLab 660 Focused-Ion-Beam Scanning-Electron Microscope (FIB-SEM) and a Hitachi S-4800 SEM (both in KMICF) to obtain backscattered electron (BSE) images and energy dispersive Xray spectrometry (EDS) maps of areas of interest. Using a JEOL 7900F SEM at the Astromaterials Research & Exploration Science (ARES) at NASA Johnson Space Center (JSC), we have obtained electron backscatter diffraction (EBSD) maps of the spinel-bearing portions of the thin sections. The EBSD data were collected under beam conditions of 20 kV, and ~90 μA, with step sizes varying from 0.05 to 2 μm. Following EBSD data collection, we processed the data using AZtecCrystal and MTEX, a free MATLAB toolbox. Results: We have found clasts with subophitic textures, that consist of primarily olivine and plagioclase, with minor amounts of pink Mg-Al spinel and pyroxene (Fig. 1). These clasts are up to ~1 mm in length and contain spinels up to 50 μm across. We have additionally identified pink Mg-Al spinels within the impact melt (i.e., not contained in lithic clasts) in both thin sections. In one instance, a single spinel grain is approximately 300 μm across (Fig. 1b, 2). The spinel fragments embedded in impact melt have varying compositions, typically distinct from the compositions of spinels in the lithic clasts. Spinel-Bearing Clasts: Ten lithic clasts with similar textures and mineral compositions were identified between 68815,17 (two clasts) and ,148 (eight clasts). These clasts fall into two groups. The first has skeletal olivine with intergranular plagioclase, with minor amounts of pyroxene and spinel (Fig. 1a, 2c, 2d). The spinel in these clasts are found amid the plagioclase. The second group have an intergranular texture of olivine and plagioclase, again with minor spinel and pyroxene. The second group may contain spinels surrounded by plagioclase, and spinels enclosed in olivine. Spinels located within both clast types range from no apparent Cr zoning, to reverse zoning (Cr-enrichment inward; Fig. 2d), to normal zoning (Cr-enrichment outward). In the clasts thus far investigated with EPMA, plagioclase compositions range from An# (molar 100×Ca/[Ca+Na+K]) 92–96. Olivine Mg# ranged from 77 to 94, while pyroxene had Mg# from 54–84. Spinel in the clasts have Cr# (molar 100×Cr/[Cr+Al]) 2–4 and Mg# 88–91, which is within the range of pristine and plutonic spinel troctolites [8]. Isolated Spinels: These crystals are generally euhedral to subhedral, and can exhibit reverse Cr zoning (Cr enrichment inward) or no apparent Cr zoning. The spinels thus far investigated via EPMA have Cr# 9–14 and Mg# 65–82. The Cr# for these spinels is within the range reported by [8], but have lower Mg#. Future Work: We will continue to process the EBSD data for these lithic and mineral clasts. We will also continue to characterize these clasts using EPMA and SEM. By thoroughly characterizing the various spinels and spinel-bearing clasts, we aim to constrain the petrogenesis of these minerals and rock fragments. Acknowledgments: We thank NASA for the loan of these thin sections. We thank Ken Domanik and Jerry Chang for their support with data collection. Work was supported by a University of Arizona RII Core Facilities Pilot Program grant and start-up funds to JJB. We acknowledge support from NASA’s Planetary Science Research program for analysis performed at JSC. References: [1] Shearer C. K. et al. (2015) Am. Min. 100, 294–325. [2] Borg L. E. et al. (2020) GCA 290, 312–332. [3] Warren P. H. (1993) Am. Min. 78, 360–376. [4] Dymek R. F. et al. (1976) LPS VII, 2335–2378. [5] Treiman et al. (2019) Am. Min. 104, 370–384. [6] Pieters et al. (2011) JGR: Plan. 116:E00G08. [7] Prissel et al. (2016) Icarus 277, 319–329. [8] Prissel et al. (2016) Am. Min. 101, 1624–1635.

spinel↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗

Characteristic x-ray emission from undermines plasmas irradiated by ultra-intense lasers

Between FY09 and FY11 we have conducted more than a dozen three-week experimental campaigns at high-power laser facilities around the world to investigate laser-channeling through x-ray and optical imaging and the conversion from laser-energy to xrays. We have performed simultaneous two-wavelength x-ray imaging (K-alpha and He-alpha) to distinguish the hot-plasma region (hot-spot) from the laser-produced electrons (K-alpha). In addition, we have initiated a new collaboration with SNL and have performed first shots on the 100 TW beamlet chamber to commission a fast x-ray streak camera to be used to investigate the temporal evolution of our K-alpha sources. We also collaborated on campaigns at the Rutherford Appleton Laboratory (UK) and the LANL Trident laser to employ laser produced x-ray sources for Thomson scattering off dense matter.

60 APPLIED LIFE SCIENCES↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. Last summer, NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This is a 30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a 60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution Xray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present a first look at the XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

Zeigler, R. A.↗

The Lunar Environment Heliophysics X-Ray Imager (LEXI) Mission

The Lunar Environment heliospheric X-ray Imager (LEXI) is a wide field-of-view soft Xray telescope developed to study solar wind-magnetosphere coupling. LEXI is part of the Blue Ghost 1 mission comprised of 10 payloads to be deployed on the lunar surface. LEXI monitors the dayside magnetopause position and shape as a function of time by observing soft X-rays (0.1–2 keV) emitted from solar wind charge-exchange between exospheric neutrals and high charge-state solar wind plasma in the dayside magnetosheath. Measurements of the shape and position of the magnetopause are used to test temporal models of mesoand macro-scale magnetic reconnection. To image the boundary, LEXI employs lobster-eye optics to focus X-rays to a microchannel plate detector with a 9.1◦ × 9.1◦ field of view.

Lunar↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical Xrays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Center's Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glenn↗

Neutron counting with cameras

A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involved are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy

Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction, each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.

60 APPLIED LIFE SCIENCES↗