Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XFELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhanced X-ray diffraction of in vivo-grown μNS crystals by viscous jets at XFELs

μNS is a 70 kDa major nonstructural protein of avian reoviruses, which cause significant economic losses in the poultry industry. They replicate inside viral factories in host cells, and the μNS protein has been suggested to be the minimal viral factor required for factory formation. Thus, determining the structure of μNS is of great importance for understanding its role in viral infection. In the study presented here, a fragment consisting of residues 448–605 of μNS was expressed as an EGFP fusion protein in Sf9 insect cells. EGFP-μNS (448–605) crystallization in Sf9 cells was monitored and verified by several imaging techniques. Cells infected with the EGFP-μNS (448–605) baculovirus formed rod-shaped microcrystals (5–15 µm in length) which were reconstituted in high-viscosity media (LCP and agarose) and investigated by serial femtosecond X-ray diffraction using viscous jets at an X-ray free-electron laser (XFEL). The crystals diffracted to 4.5 Å resolution. A total of 4227 diffraction snapshots were successfully indexed into a hexagonal lattice with unit-cell parameters a = 109.29, b = 110.29, c = 324.97 Å. The final data set was merged and refined to 7.0 Å resolution. Preliminary electron-density maps were obtained. While more diffraction data are required to solve the structure of μNS (448–605) , the current experimental strategy, which couples high-viscosity crystal delivery at an XFEL with in cellulo crystallization, paves the way towards structure determination of the μNS protein.

59 BASIC BIOLOGICAL SCIENCES↗

USING ER@CEBAF TO SHOW THAT A MULTIPASS ERL CAN DRIVE AN XFEL

A multi-pass recirculating superconducting CW linac offers a cost effective path to a multi-user facility with unprecedented scientific and industrial reach over a wide range of disciplines. We propose such a facility as an option for a potential UK-XFEL. Energy Recovery enables multi-MHz FEL sources, for example, an X-ray FEL oscillator or regenerative amplifier FEL. Additionally, combining with external lasers and/or self-interaction would provide access to MeV and GeV gamma-rays via inverse Compton scattering at high average power for nuclear and particle physics applications. An opportunity exists to demonstrate the necessary point-to-parallel longitudinal matches to drive an XFEL and successfully energy recover at the upcoming 5-pass up, 5-pass down Energy Recovery experiment on CEBAF at JLab termed ER@CEBAF. We show candidate matches and simulations supporting the minimal necessary modifications to CEBAF this will require. This includes linearisation of the longitudinal phase space in the injector and a reduction in the dispersion of the arcs, both of which increase the energy acceptance of CEBAF. We expect to commence initial tests of these adaptations on CEBAF during 2021.

Perez-Segurana, G.↗

Superconducting radio frequency photoinjectors for CW-XFEL

A dependable and consistent electron source is a crucial requirement for the achievement of high-power free electron lasers (FELs). Over the past two decades, it has been demonstrated that photoinjectors based on SRF technology (SRF guns) are suitable for continuous wave (CW) beam generation. SRF guns possess both the high accelerating field gradients of normal conducting RF photoinjectors and the low power dissipation thanks to mature SRF cavity technology, and therefore have the potential to provide the high-brightness, high-current beams required for CW-XFELs. After the demonstration of the first SRF gun in Dresden-Rossendorf, several SRF gun programs based on different approaches have achieved promising progress and even succeeded in routine operation. SRF guns are expected to play an important role in XFEL facilities in the near future. In this paper, we give an overview of design concepts, important parameters and development status of the worldwide SRF gun projects.

47 OTHER INSTRUMENTATION↗

The importance of shear on the collective charge transport in CDWs revealed by an XFEL source

Charge transport in materials has an impact on a wide range of devices based on semiconductor, battery, or superconductor technology. Charge transport in sliding charge density waves (CDW) differs from all others in that the atomic lattice is directly involved in the transport process. To obtain an overall picture of the structural changes associated to the collective transport, the large coherent x-ray beam generated by an x-ray free-electron laser (XFEL) source was used. The CDW phase can be retrieved over the entire sample from diffracted intensities using a genetic algorithm. For currents below threshold, increasing shear deformation is observed in the central part of the sample while longitudinal deformation appears above threshold when shear relaxes. Shear thus precedes longitudinal deformation, with relaxation of one leading to the appearance of the other. Moreover, strain accumulates on surface steps in the sliding regime, demonstrating the strong pinning character of these surface discontinuities. The sliding process of nanometric CDW involves macroscopic sample dimensions.

36 MATERIALS SCIENCE↗

Photon-shot-noise-limited transient absorption soft X-ray spectroscopy at the European XFEL

Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystallization of ApoA1 and ApoE4 Nanolipoprotein Particles and Initial XFEL-Based Structural Studies

Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via high-density lipoprotein (HDL) and low-density lipoprotein (LDL) maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics, and to develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compression rate effects on the Bi-III stability field in dynamic diamond anvil cell XFEL studies of bismuth

This study aims to resolve conflicting observations of bismuth’s high-pressure phase transitions across static, intermediate, and shock compression regimes. We probed its high-pressure structural sequence using the dynamic diamond anvil cell with and time-resolved X-ray diffraction with microsecond resolution at an X-ray free-electron laser. At room temperature and pressures up to 20 gigapascals, bismuth evolves through the same structural sequence previously identified under static compression. However, the transformation behavior differs in important ways under dynamic loading. In particular, the transition from the incommensurate intermediate-pressure phase to the high symmetry high pressure phase begins at pressures about 2 to 4 gigapascals lower than in static experiments, and the onset of this transformation depends on the compression rate. As a result, the stability field of the intermediate-pressure phase is reduced under rapid compression. Our results suggest that at sufficiently fast loading rates the intermediate phase may be bypassed entirely, consistent with previous shock-compression observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Spatiotemporal dynamics of fast electron heating in solid-density matter via XFEL

Abstract High-intensity, short-pulse lasers are crucial for generating energetic electrons that produce high-energy-density (HED) states in matter, offering potential applications in igniting dense fusion fuels for fast ignition laser fusion. High-density targets heated by these electrons exhibit spatially non-uniform and highly transient conditions, which have been challenging to characterize due to limitations in diagnostics that provide simultaneous high spatial and temporal resolution. Here, we employ an X-ray Free Electron Laser (XFEL) to achieve spatiotemporally resolved measurements at sub-micron and femtosecond scales on a solid-density copper foil heated by laser-driven fast electrons. Our X-ray transmission imaging reveals the formation of a solid-density hot plasma localized to the laser spot size, surrounded by Fermi degenerate, warm dense matter within a picosecond, and the energy relaxation occurring within the hot plasma over tens of picoseconds. These results validate 2D particle-in-cell simulations incorporating atomic processes and provide insights into the energy transfer mechanisms beyond current simulation capabilities. This work significantly advances our understanding of rapid fast electron heating and energy relaxation in solid-density matter, serving as a key stepping stone towards efficient high-density plasma heating and furthering the fields of HED science and inertial fusion energy research using intense, short-pulse lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small-wedge synchrotron and serial XFEL datasets for Cysteinyl leukotriene GPCRs

Structural studies of challenging targets such as G protein-coupled receptors (GPCRs) have accelerated during the last several years due to the development of new approaches, including small-wedge and serial crystallography. Here, we describe the deposition of seven datasets consisting of X-ray diffraction images acquired from lipidic cubic phase (LCP) grown microcrystals of two human GPCRs, Cysteinyl leukotriene receptors 1 and 2 (CysLT 1 R and CysLT 2 R), in complex with various antagonists. Five datasets were collected using small-wedge synchrotron crystallography (SWSX) at the European Synchrotron Radiation Facility with multiple crystals under cryo-conditions. Two datasets were collected using X-ray free electron laser (XFEL) serial femtosecond crystallography (SFX) at the Linac Coherent Light Source, with microcrystals delivered at room temperature into the beam within LCP matrix by a viscous media microextrusion injector. All seven datasets have been deposited in the open-access databases Zenodo and CXIDB. Here, we describe sample preparation and annotate crystallization conditions for each partial and full datasets. We also document full processing pipelines and provide wrapper scripts for SWSX and SFX data processing. A Correction to this paper has been published: https://doi.org/10.1038/s41597-020-00759-w

97 MATHEMATICS AND COMPUTING↗

Femtosecond laser produced periodic plasma in a colloidal crystal probed by XFEL radiation

With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free-Electron Lasers (XFELs) delivering intense femtosecond X-ray pulses, allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present a detailed study of the periodic plasma created from the colloidal crystal. Both experimental data and theory modeling show that the periodicity in the sample survives to a large extent the extreme excitation and shock wave propagation inside the colloidal crystal. This feature enables probing the excited crystal, using the powerful Bragg peak analysis, in contrast to the conventional studies of dense plasma created from bulk samples for which probing with Bragg diffraction technique is not possible. X-ray diffraction measurements of excited colloidal crystals may then lead towards a better understanding of matter phase transitions under extreme irradiation conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of gas background on XFEL single-particle imaging

Abstract Single-particle imaging (SPI) using X-ray free-electron Lasers (XFELs) offers the potential to determine protein structures at high spatial and temporal resolutions without the need for crystallization or vitrification. However, the technique faces challenges due to weak diffraction signals from single proteins and significant background scattering from gases used for sample delivery. A recent observation of a diffraction pattern from an isolated GroEL protein complex Ekeberg T et al. (Light Sci Appl 13:15, 2024.https://doi.org/10.1038/274s41377-023-01352-7) had similar numbers of signal and background photons. Ongoing efforts aim to reduce the background created by sample delivery, with one approach replacing most of the used gas with helium Yenupuri T et al. (Sci Rep 14:4401, 2024.https://doi.org/10.1038/s41598-024-54605-9). In this study, we investigate the effects of a reduced background on the resolution limits for SPI of isolated proteins under different experiment conditions. As a test case, we used GroEL, and we used experimentally derived parameters for our simulations. We observe that background significantly impacts the achievable resolution, particularly when the signal strength is comparable to the background. This is best exemplified at 6.0 keV, where a background reduction by a factor of 10 leads to a resolution improvement from 1.9 to 1.2 nm, for a dataset of$$10^4$$patterns.

Science & Technology - Other Topics↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

Fully plasma-based electron injector for a linear collider or XFEL

We demonstrate through high-fidelity particle-in-cell (PIC) simulations a simple approach for efficiently generating 20 + GeV electron beams with the necessary charge, energy spread, and emittance for use as an injector in a future linear collider or a next generation XFEL. A high quality injected bunch is generated by self-focusing an unmatched electron driver in a nonlinear plasma wakefield. Over pump depletion distances, the drive beam dynamics and self-loading effects lead to high energy, low-energy spread output beams. For plasma densities of 10 18 c⁢m −3 , PIC simulation results indicate that self-injected beams with 0.52 n⁢C charge can be accelerated to 20 GeV with projected core energy spreads of ≲ 1%, normalized slice emittances of 110n⁢m, peak normalized brightness of ≳ 10 19 A/m 2 /rad 2 , and transfer efficiencies of ≳ 44%.

Particle acceleration in plasmas↗

Speckle contrast from the split-and-delay unit with seeded X-ray pulses of the MID instrument at European XFEL

We report on the coherence properties and characteristics of the split- and-delay unit at the Materials Imaging and Dynamics instrument of the European XFEL under seeded-beam conditions. Our investigation focuses on the speckle contrast extracted from the scattering patterns from static scatterers and pulse splitting characteristics. Seeded-beam operation enabled a high throughput of the split-and-delay unit. We highlight the invaluable potential of the split-and-delay unit for experimental investigations for enhancing our understanding of ultrafast phenomena in molecular liquids, such as water and aqueous solutions.

Fuoss, Paul↗

Complementarity of neutron, XFEL and synchrotron crystallography for defining the structures of metalloenzymes at room temperature

Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.

36 MATERIALS SCIENCE↗