Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-Ray Microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Consolidation of silicon nitride without additives

The feasibility of producing a sound, dense Si3N4 body without additives was explored, using conventional gas hot isostatic pressing techniques and an uncommon hydraulic hot isostatic pressing technique. These two techniques produce much higher pressure 275-413 MN/m sq (40,000 - 60,000 psi) than hot-pressing techniques. Evaluation was based on density measurement, microscopic examination, both optical and electron, and X-ray diffraction analysis. The results are summarized as follows: (1) Si3N4 can be densified to high density, greater than 95% of theoretical, without additions. (2) The higher density Si3N4 specimens appear to be associated with a greater amount of alpha to beta transformation. (3) Under high pressure, the alpha to beta transformation can occur at a temperature as low as 1150 C. (4) Grain deformation and subsequent recrystallization and grain refinement result from hot isostatic pressing of Si3N4.

Sikora, P. F.↗

Lunar plagioclase - A mineralogical study.

Mineralogical properties of calcic plagioclase have been analyzed using U-stage, microprobe, X-ray precession cameras, and a 650-kV electron microscope. The orientation of the optical indicatrix in lunar and eucrite anorthites is described with Euler angles. All crystals, except one, show strong b- and diffuse c-reflections in precession photographs. In 10017, b-split-reflections have been found. Dark-field electron micrographs of 14310 anorthite show both large and small b-antiphase domains, and an exsolution structure in crystals that display b-split reflections in the diffractogram. Diffuseness of c-reflections in X-ray photographs and the inability to resolve c-domains in electron micrographs in An 94 anorthite of 14310 indicate relatively rapid cooling of this rock compared to plutonic rocks.

Wenk, H.-R.↗

Analysis of ablation debris from natural and artificial iron meteorites

Artificial ablation studies were performed on iron and nickel-iron samples using an arc-heated plasma of ionized air. Experiment conditions simulated a meteoroid traveling about 12 km/sec at an altitude of 70 km. The artificially produced fusion crusts and ablation debris show features very similar to natural fusion crusts of the iron meteorites Boguslavka, Norfork, and N'Kandhla and to magnetic spherules recovered from Mn nodules. X-ray diffraction, electron microprobe, optical, and scanning electron microscope analyses reveal that important mineralogical, elemental, and textural changes occur during ablation. Some metal is melted and ablated. The outer margin of the melted rind is oxidized and recrystallizes as a discontinuous crust of magnetite and wustite. Adjacent to the oxidized metallic ablation zone is an unoxidized metallic ablation zone in which structures such as Widmannstatten bands are obliterated as the metal is transformed to unequilibrated alpha 2 nickel-iron. Volatile elements are vaporized and less volatile elements undergo fractionation.

Blanchard, M. B.↗

TRIIG - Time-lapse reproduction of images through interactive graphics

Description of the hardware and software implementing the system of time-lapse reproduction of images through interactive graphics (TRIIG). The system produces a quality hard copy of processed images in a fast and inexpensive manner. This capability allows for optimal development of processing software through the rapid viewing of many image frames in an interactive mode. Three critical optical devices are used to reproduce an image: an Optronics photo reader/writer, the Adage Graphics Terminal, and Polaroid Type 57 high speed film. Typical sources of digitized images are observation satellites, such as ERTS or Mariner, computer coupled electron microscopes for high-magnification studies, or computer coupled X-ray devices for medical research.

Buckner, J. D.↗

Preliminary results from the noctilucent sampling from Kiruna in 1970.

On Aug. 8, 1970 at 0148 and 0354 local time, two Pandora sounding rocket payloads were launched from the ESRO range in Kiruna, Sweden, during a noctilucent cloud display. Large numbers of particles were collected, many of which appear to be micrometeorites coated with a low density material. Typical electron micrographs are shown, and numerical densities as a function of altitude are given. Particle composition information has been obtained by use of dispersive X-ray analysis equipment attached to our Philips EM 300 electron microscope.

Hallgren, D. S.↗

Rocket effluent: Its ice nucleation activity and related properties

To investigate the possibility of inadvertent weather modification from rocket effluent, aerosol samples were collected from an instrumented aircraft subsequent to the Voyager 1 and 2 launches. The aerosol's morphology, concentration, and size distribution were examined with an electron microscope. The elemental compositions of individual particles were analyzed with an X-ray energy spectrometer. Ice nucleus concentration was measured with a thermal diffusion chamber. The particles' physical and chemical properties were related to their ice nucleation activity. A laboratory experiment on rocket propellant exhaust was conducted under controlled conditions. Both laboratory and field experimental results indicated that rocket propellant exhaust can produce active ice nuclei and modify local weather in suitable meteorological conditions.

Parungo, F. P.↗

Rocket effluent - Its ice nucleation activity and related properties

To investigate the possibility of inadvertent weather modification from rocket effluent, aerosol samples were collected from an instrumented aircraft subsequent to the Voyager I and II launches. The aerosol's morphology, concentration and size distribution were examined with an electron microscope. The elemental compositions of individual particles were analyzed with an X-ray energy spectrometer. Ice nucleus concentration was measured with a subfreezing thermal diffusion chamber. The particles' physical and chemical properties were related to their ice nucleation activity. A laboratory experiment on rocket propellant exhaust was conducted under controlled conditions. Both laboratory and field experimental results indicated that rocket propellant exhaust can produce active ice nuclei. Their consequences for potential inadvertant weather modification demand additional study.

Parungo, F. P.↗

The calibration of photographic and spectroscopic films: 1: A microscopic analysis of IIaO films. 2: The effects of agitation and soaking on IIaO films. 3: The effects of electric field on IIaO films. 4: The effects of X-ray radiation on IIaO films

The grain structure of the emulsion using both reflected and transmission light was examined along with the effects of soaking. The effect of a static charge by a Tesla-coil, and the effects of airport equipment, and dental X-rays on the film were also analyzed.

Hammond, E. C., Jr.↗

Improved plaque materials for aerospace nickel-cadmium cells

Improved cadmium electrode substrates with precisely controlled microstructures for possible use in aerospace nickel-cadmium cells were prepared. The preparative technique was a powder metallurgical process in which a fugitive pore-former and a nickel powder were blended, then isostatically compacted, and subsequently sintered. Cadmium electrodes prepared from such substrates were cycle tested using an accelerated tortuous test regime. It was discovered that plaques of 60% or 80% porosity prepared with a 25 micron pore-former were better than state-of-the-art electrodes in terms of efficienty and/or mechanical strength. The 60% structures were particularly outstanding in this respect in that they had efficiencies only 5-10 percentage points lower than state-of-the-art electrodes and vastly superior mechanical properties. This added strength was observed to eliminate cracking and physical degradation of the electrodes during processing and cycling. The cadmium electrodes prepared from the 80% porous substrates proved to be the best electrodes made during the course of the work from the point of view of highest efficiency. Three-point bend tests were used to measure mechanical properties of the plaques produced and also as a general characterization tool. In addition, the BET surface areas of selected specimens was determined. The SEM was used for judging microscopic uniformity and quantitatively determining the induced pore size and various other fine structures in the substrates. The technique of X-ray radiography was used to follow the bulk uniformity of the substrates at various stages of their processing.

Luksha, E.↗

Some wear studies on aircraft brake systems

An initial investigation of worn surfaces in friction pads and steel rotors used in current aircraft brakes was carried out using electron microprobe and X-ray diffraction analysis. It consists of the topographical study and the analysis of chemical element distribution. Based upon this initial examination, two approaches, microscopic and macroscopic have been conducted to interpret and formulate the wear mechanism of the aircraft brake materials. Microscopically, the wear particles were examined. The initiation and growth of surface cracks and the oxidation were emphasized in this investigation. Macroscopically, it has been found that, for the current copper based brake material sliding against 17-22 AS steel in a caliper brake, the surface temperature raised due to frictional heat is nonlinearly proportional to the load applied and slide time with speed at 1750 rpm. The wear of brake materials is then proportional to this temperature and is also a function of the melting temperature for copper.

Ho, T. L.↗

Airborne particle monitoring by electrostatic precipitation

For qualitative analysis of atmospheric particulates by microscopy, the sampling device should preserve the particles in the state existing at the moment of capture. A collector is described that uses electrostatic precipitation to capture and disperse specimens on various substrates for direct insertion into microscopes. Sampling runs in various atmospheres are described. Micrographs are presented to show particle morphology and distribution on the substrates. Chemical identification by X-ray energy probe and electron diffraction is illustrated.

Robinson, J. C.↗

Generation of ultraviolet and vacuum ultraviolet radiation

The paper describes the use of nonlinear optical techniques for the generation of coherent radiation at ultraviolet, vacuum ultraviolet, and soft X-ray wavelengths. Mixtures of metal vapors and inert gases, and other mixed gas systems, allow generation to regions of the spectrum where nonlinear optical crystals are opaque; and also allow generations at high incident power and energy densities. Progress is reported on programs aimed at efficient conversion from 1.064 microns to 3547 A, and from 3547 A to 1182 A. To date, the shortest wavelength generated by this technique is 887 A. Theoretical considerations indicate that generation into the soft X-ray region should be possible. Using 1182 A radiation, a holographic grating with a fringe spacing of 836 A has been constructed and examined on an electron microscope.

Harris, S. E.↗

Wear studies on aircraft brake materials

An investigation of both worn surfaces of friction pads and steel rotors which are being applied in current aircraft brakes has been carried out by employing an X-ray diffraction technique. It consists of the analysis of chemical element distribution in the surface layers. The wear particles were also examined by using the scanning electron microscope. The initiation and growth of surface cracks and the oxidation were emphasized in this investigation. A wear model was proposed for the current aircraft brake materials. Essentially this model proposed that cracks are formed in the surface layer of the brake material due to the normal and frictional stresses. It is primarily surface temperature dependent.

Ho, T. L.↗

Dynamic-scanning-electron-microscope study of friction and wear

A friction and wear apparatus was built into a real time scanning electron microscope (SEM). The apparatus and SEM comprise a system which provides the capability of performing dynamic friction and wear experiments in situ. When the system is used in conjunction with dispersive X-ray analysis, a wide range of information on the wearing process can be obtained. The type of wear and variation with speed, load, and time can be investigated. The source, size, and distribution of wear particles can be determined and metallic transferal observed. Some typical results obtained with aluminum, copper, and iron specimens are given.

Brainard, W. A.↗

Characterization of the adsorption of water vapor and chlorine on microcrystalline silica

The characterization of water adsorption on silica is necessary to an understanding of how hydrogen chloride interacts with silica. The adsorption as a function of outgas temperatures of silica and as a function of the isotherm temperature was studied. Characterization of the silica structure by infrared analysis, X-ray diffraction and differential scanning calorimetry, surface area determinations, characterization of the sample surface by electron spectroscopy for chemical analysis (ESCA), and determinations of the heat of immersion in water of silica were investigated. The silica with a scanning electron microscope was examined.

Skiles, J. A.↗

Scanning electron microscope investigation of the structural growth in thick sputtered coatings

Sputtered S-Monel, silver, and 304 stainless steel coatings and molybdenum disulfide coatings were deposited on mica and metal substrates with various surface finishes to investigate the structural growth of the coating by scanning electron microscopy. The geometry and the surface morphology of the nodules are characterized. Compositional changes within the coating were analyzed by energy dispersive X-ray analysis. Defects in the surface finish act as preferential nucleation sites and form isolated overlapping and complex nodules and various unusual surface overgrowths on the coating. The nodule boundaries are very vulnerable to chemical etching and these nodules do not disappear after full annealing. Further, they have undesirable effects on mechanical properties; cracks are initiated at the nodules when the coating is stressed by mechanical forces.

Spalvins, T.↗

Diffusion length measurement using the scanning electron microscope

The present work describes a measuring technique employing the scanning electron microscope in which values of the true bulk diffusion length are obtained. It is shown that surface recombination effects can be eliminated through application of highly doped surface field layers. The effects of high injection level and low-high junction current generation are investigated. Results obtained with this technique are compared to those obtained by a penetrating radiation (X-ray) method, and a close agreement is found. The SEM technique is limited to cells that contain a back surface field layer.

Weizer, V. G.↗

Medical Image Analysis Facility

To improve the quality of photos sent to Earth by unmanned spacecraft. NASA's Jet Propulsion Laboratory (JPL) developed a computerized image enhancement process that brings out detail not visible in the basic photo. JPL is now applying this technology to biomedical research in its Medical lrnage Analysis Facility, which employs computer enhancement techniques to analyze x-ray films of internal organs, such as the heart and lung. A major objective is study of the effects of I stress on persons with heart disease. In animal tests, computerized image processing is being used to study coronary artery lesions and the degree to which they reduce arterial blood flow when stress is applied. The photos illustrate the enhancement process. The upper picture is an x-ray photo in which the artery (dotted line) is barely discernible; in the post-enhancement photo at right, the whole artery and the lesions along its wall are clearly visible. The Medical lrnage Analysis Facility offers a faster means of studying the effects of complex coronary lesions in humans, and the research now being conducted on animals is expected to have important application to diagnosis and treatment of human coronary disease. Other uses of the facility's image processing capability include analysis of muscle biopsy and pap smear specimens, and study of the microscopic structure of fibroprotein in the human lung. Working with JPL on experiments are NASA's Ames Research Center, the University of Southern California School of Medicine, and Rancho Los Amigos Hospital, Downey, California.

Source record↗