Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Windows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Si–Cl 2 –Ar + Atomic Layer Etching Window: A Fundamental Study Using Molecular Dynamics Simulations and a Reduced Order Model

Silicon (Si) atomic layer etching (ALE) by alternating exposure to chlorine gas (Cl 2 ) and argon ions (Ar + ) is studied by using molecular dynamics (MD) simulations and a reduced order model (ROM). Here, the purpose of this study is to elucidate the properties of the ALE window, a range of ion energies where the amount of Si etched over a series of cycles is nonzero and nearly independent of ion energy. Experimental studies of the Si–Cl 2 –Ar + ALE system report contradictory results related to the ALE window’s ion energy range. Both MD simulations and the ROM show that there is an ALE window present from approximately 15 to 20 eV for normal incidence argon ions. The Si–Cl 2 –Ar + system, therefore, exhibits a narrow ALE window. The amount of Si etched per cycle is less than one atomic layer because of the higher etch yield of Cl atoms relative to atomic Si and silicon chlorides. A modified version of the ROM with an artificially increased Si physical sputtering threshold energy expands the ALE window, illustrating the importance of the difference in chemical and physical sputtering threshold energies in the ALE window energy range. The ROM is also used to examine the dependence of the EPC on the Ar + ion fluence.

energy↗

Identification of a window for quiescent H-mode operation in MHD stability diagram of DIII-D plasmas

A window for quiescent H-mode (QH-mode) operation in DIII-D plasmas in the diagram of pedestal magnetohydrodynamic (MHD) stability was identified through linear MHD stability analysis, accounting for the effects of plasma rotation and ion diamagnetic drift. The operation window lies between the stability boundaries of the kink/peeling mode (K/PM) identified with and without the inclusion of plasma rotation effects. In this region, the mode remains unstable unless rotation effects are considered alongside the ion diamagnetic drift, which is consistently included in the analysis. The stabilization of the MHD mode, facilitated by the coupled effects of plasma rotation and ion diamagnetic drift, plays a crucial role in widening the window, enabling the attainment of the QH-mode state. Furthermore, the suppression of edge localized modes (ELM) can be achieved by controlling the pedestal structure to ensure the plasma state remains within the operation window. The location of the operation window in the stability diagram depends on the K/PM stability properties. Therefore, optimizing conditions for QH-mode requires adjustments based on changes in stability characteristics. A pressure pedestal and its associated bootstrap current density near the last closed flux surface are advantageous for situating the plasma state within the window. However, excessive current density can trigger ELMs. This trend was confirmed through comparisons of MHD stability diagrams between QH-mode and ELMy H-mode plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the impact of the galaxy window function on cosmological parameter estimation

One important source of systematics in galaxy redshift surveys comes from the estimation of the galaxy window function. Up until now, the impact of the uncertainty in estimating the galaxy window function on parameter inference has not been properly studied. In this paper, we show that the uncertainty and the bias in estimating the galaxy window function will be salient for ongoing and next-generation galaxy surveys using a simulation-based approach. With a specific case study of cross-correlating emission-line galaxies from the DESI Legacy Imaging Surveys and the Planck cosmic microwave background lensing map, we show that neural network-based regression approaches to modelling the window function are superior in comparison to linear regression-based models. Here, we additionally show that the definition of the galaxy overdensity estimator can impact the overall signal-to-noise of observed power spectra. Finally, we show that the additive biases coming from the window functions can significantly bias the modes of the inferred parameters and also degrade their precision. Thus, a careful understanding of the window functions will be essential to conduct cosmological experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing the dark-state bistability and thermal stability of zinc dynamic windows with nitrile electrolytes

Reversible metal electrodeposition (RME) for dynamic windows is a promising alternative to traditional electrochromics. We explore the reasons behind the bistability of practical RME dynamic windows under a wide temperature range, i.e., how well they maintain their dark state without external power. While Zn dynamic windows with dimethyl sulfoxide electrolytes exhibit adequate bistability at room temperature, their performance degrades at elevated temperatures due to the presence of small amounts of water. Here, to overcome this problem, we developed a set of Zn nitrile electrolytes. The integrated devices can maintain dark-state bistability over at least 1 month at 85°C with 0.1% transmission using a propionitrile (PrCN) electrolyte. Additionally, the PrCN-based Zn dynamic windows possess high optical contrast, color-neutral switching, and promising cyclability, making Zn RME in nitrile electrolytes a promising solution for achieving robust dynamic windows.

RME↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. This report, Performance of Windows in Walls with Continuous Insulation , explores the common method for installing windows in walls with continuous insulation and presents acceptance criteria for evaluating the performance of windows installed in walls with and without continuous insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Impact of window temperature variations on ITER toroidal interferometer and polarimeter (TIP) measurements

Abstract The toroidal interferometer and polarimeter (TIP) is one of the primary electron density diagnostics on ITER. To meet measurement requirements over several thousand seconds, environmental factors such as changes in the window temperature, air temperature, and humidity, which can cause uncompensated phase drifts, must be minimized. This paper reports measurements of the phase shift induced by ZnSe and BaF₂ windows as their temperature is varied utilizing the TIP prototype. To accomplish these measurements, test pieces of BaF₂ and ZnSe are placed in a small oven that is located in one leg of the 10.59/5.22 micron two-color interferometer TIP prototype. The oven temperature was varied from room temperature to ∼90 °C, which is slightly higher than the expected window temperatures on ITER. The vibration compensated phase shifts measured for these two materials are dϕᵥ꜀ /dT/L = 0.0121 and −0.275 deg. /°C/cm −1 for BaF₂ and ZnSe, respectively. From these measurements, it was concluded that temperature variations of the environmental/secondary confinement barrier window and primary vacuum window have to be suppressed within approximately 1°C and 2°C, respectively, in order to passively meet the electron density measurement requirements in ITER.

Akiyama, T (ORCID:0000000198469795)↗

Data-driven estimates for light-quark-connected and strange-plus-disconnected hadronic g − 2 window quantities

A number of discrepancies have emerged between lattice computations and data-driven dispersive evaluations of the RBC/UKQCD intermediate-window-hadronic contribution to the muon anomalous magnetic moment. It is therefore interesting to obtain data-driven estimates for the light-quark-connected and strange-plus-disconnected components of this window quantity, allowing for a more detailed comparison between the lattice and data-driven approaches. The aim of this paper is to provide these estimates, extending the analysis to several other window quantities, including two windows designed to focus on the region in which the two-pion contribution is dominant. Clear discrepancies are observed for all light-quark-connected contributions considered, while good agreement with lattice results is found for strange-plus-disconnected contributions to the quantities for which corresponding lattice results exist. The largest of these discrepancies is that for the RBC/UKQCD intermediate window, where, as previously reported, our data-driven result, a μ W 1 , lqc = 198.9 ( 1.1 ) × 10 − 10 , is in significant tension with the results of 8 different recent lattice determinations. Our strategy is the same as recently employed in obtaining data-driven estimates for the light-quark-connected and strange-plus-disconnected components of the full leading-order hadronic vacuum polarization contribution to the muon anomalous magnetic moment. Updated versions of those earlier results are also presented, for completeness. Published by the American Physical Society 2024

Benton, Genessa (ORCID:0009000515763654)↗

Low RF Loss DC Conductive Ceramic for High Power Input Coupler Windows for SRF Cavities

Euclid Techlabs, LLC is developing a low RF loss/DC conductive MgTi ceramics for high power input coupler windows for SRF cavities, under DOE SBIR phase II grant DE-SC0017150. JLab was subcontracted to: fabricate two 500 kW capable pre-stressed coaxial windows; provide an RF testing fixture, and test the window with low power and high power RF. This collaboration helped to develop a better material for high power RF windows, with low RF loss and less prone to arcing, with the potential to improve the state of the art high power RF window performance.

36 MATERIALS SCIENCE↗

Thermally Insulating Transparent Barrier (THINNER) coatings on single pane windows

Conventional silica aerogel monoliths can provide remarkable thermal insulation but the presence of large pores (> 30 nm) tends to scatter visible light and render the material opaque or translucent instead of transparent. In addition, they are prone to cracking during synthesis and handling which makes them difficult to integrate in products and in particular in window solutions. This project developed two new solgel synthesis methods using silica precursors or preformed silica nanoparticles and ambient drying to produce mesoporous organo-silica monoliths. The monoliths were (i) thermally insulating, (ii) optically transparent, (iii) flexible, and (iv) hydrophobic. They feature porosity ranging from 50% to 90% with narrow pore size distribution with pore less than 20 nm resulting in excellent optical clarity (haze < 2%) and very low thermal conductivity (< 30 mW/mK). Interestingly, not only porosity but also pore size and mass fractal dimension were found to affect the thermal conductivity of the mesoporous silica. The superior transparency of the monoliths was shown to be attributed to dependent scattering among silica nanoparticles. Flexibility was achieved through trimethylchlorosilane surface modification. Furthermore, process scale-up and integration of the ambigel monoliths into window solutions using optically clear adhesives were also demonstrated in 6”x6” double-pane windows. The aerogel and the window solution were shown to be durable to accelerated aging under UV, moisture, and/or temperature gradient and thermal cycling. Overall, the window solution achieved the technical performance and the cost target of $10/sqft set for the SHIELD program. However, scaling to industry relevant scale (> 10’x10’) remains a challenge due to requirements on the drying process and fume hood size and to the propensity of large aerogel slab to crack during drying.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

Origin of high optical contrast in zinc-zinc oxide electrodeposits for dynamic windows

The control of solar light and heat emission through windows is an important strategy for increasing the energy efficiency of buildings. Reversible Zn electrodeposition has recently emerged as a promising method for constructing electronically tintable robust dynamic windows. In Zn electrodeposits formed from dimethyl sulfoxide (DMSO) electrolytes during device tinting, we observe extraordinary absorption that is in excess of what is predicted by the Beer-Lambert law for a uniform Zn thin film. Here, the charge required to electroplate these films is abnormally low, significantly less than previously reported dynamic windows based on reversible metal electrodeposition, which facilitates the construction of large-area devices that switch uniformly. Finite-difference time-domain (FDTD) simulations are used to investigate the origin of this enhanced absorption, which arises from plasmonic effects among the Zn nanoparticles and ZnO dendrites in the film. The dielectric ZnO dendrites promote absorption via slit-like Zn-dielectric-Zn structures that from hybrid surface plasmon resonance at metal walls. Through these investigations, we provide design principles to construct low-charge and high-contrast metal and metal oxide-based dynamic windows.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗