Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wide dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Log amplifier instrument measures physiological biopotentials over wide dynamic range

To record biopotentials with extreme dynamic ranges, biopotential inputs are capacitatively coupled to a miniature, low power, solid-state signal conditioner consisting of a two-stage differential preamplifier that has a low noise figure. The ouput of the preamplifier uses diodes to provide an overall gain which is nearly logarithmic.

Kado, R. T.↗

Wide-range dynamic pressure sensor

Transducer measures pressure by sensing the damping of a vibrating diaphragm immersed in the atmosphere to be measured. Improved sensor can be included in rugged, lightweight package for use aboard aircraft, meteorological vehicles, and space probes.

Dimeff, J.↗

Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Franklin, M. L.↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

Wide-dynamic-range detector

Circuit drives diode detector with amplifier having high and constant output impedance. Basic circuit could be used in high-performance AM radios, tape players, and phonographs.

Matheson, R. J.↗

(abstract) Wide Dynamic Range Porous Plug and Vent Line for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperture on orbit. At launch the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially the helium flow on orbit will be 10 to 20 times larger than required for steady-state operation. The vent line and the liquid-vapor phase separator (porous plug) therefore must accomodate a large dynamic operational range. For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be 1.4 K. We will present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of Gravity Probe-B cryostat will also be presented.

infrared space helium cryostat↗

Wide Dynamic Range Porous Plug for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperature on orbit. At launch, the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially, the helium flow on orbit will be 20 to 30 times larger than required for steady-state operation. The vent line and the liquid/vapor phase separator (porous plug) therefore must accommodate a large dynamic operational range.For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be at 1.4 K. We present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of the Gravity Probe-B cryostat will be presented also.

SIRTF, Liquid/Vapor Phase, Separator, Porous Plug↗

Conductance measurement circuit with wide dynamic range

A conductance measurement circuit to measure conductance of a solution under test with an output voltage proportional to conductance over a 5-decade range, i.e., 0.01 uS to 1000 uS or from 0.1 uS to 10,000 uS. An increase in conductance indicates growth, or multiplication, of the bacteria in the test solution. Two circuits are used each for an alternate half-cycle time periods of an alternate squarewave in order to cause alternate and opposite currents to be applied to the test solution. The output of one of the two circuits may be scaled for a different range optimum switching frequency dependent upon the solution conductance and to enable uninterrupted measurement over the complete 5-decade range. This circuitry provides two overlapping ranges of conductance which can be read simultaneously without discontinuity thereby eliminating range switching within the basic circuitry. A VCO is used to automatically change the operating frequency according to the particular value of the conductance being measured, and comparators indicate which range is valid and also facilitate computer-controlled data acquisition. A multiplexer may be used to monitor any number of solutions under test continuously.

Mount, Bruce E.↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

Use of imaging plates at near saturation for high energy density particles

Since an imaging plate (IP) is sensitive to electron, ion, and x rays, it can be used as a detector for laser plasma experiment using ultraintense laser. Moreover, an IP has the advantageous features such as high sensitivity, wide dynamic range, and high spatial resolution. Even though IP itself has a considerable wide dynamic range up to 10{sup 5}, the IP data have appeared often saturated at an IP reading device. We propose a reading technique by inserting optical density filters so that an apparently saturated IP data can be saved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-frequency range, dynamic matching network and power system for the “Shoelace” radio frequency antenna on the Alcator C-Mod tokamak

A wide-frequency range (50–300 kHz) power system has been implemented for use with a new RF antenna – the “Shoelace” antenna – built to drive coherent plasma fluctuations in the edge of the Alcator C-Mod tokamak. A custom, dynamically tunable matching network allows two commercial 1 kW, 50-Ω RF amplifiers to drive the low-impedance, inductive load presented by the antenna. This is accomplished by a discretely variable L-match network, with 81 independently selected steps available for each of the series and parallel legs of the matching configuration. A compact programmable logic device provides a control system that measures the frequency with better than 1 kHz accuracy and transitions to the correct tuning state in less than 1 ms. At least 85% of source power is dissipated in the antenna across the operational frequency range, with a minimum frequency slew rate of 1 MHz/s; the best performance is achieved in the narrower band from 80 to 150 kHz which is of interest in typical experiments. The RF frequency can be run with open-loop control, following a pre-programmed analog waveform, or phase-locked to track a plasma fluctuation diagnostic signal in real time with programmable phase delay; the amplitude control is always open-loop. The control waveforms and phase delay are programmed remotely. These tools have enabled first-of-a-kind measurements of the tokamak edge plasma system response in the frequency range and at the wave number at which coherent fluctuations regulate heat and particle transport through the plasma boundary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 100,000 pulse height analyzer for use in High Energy Cosmic Ray Experiments (HECRE) on high altitude balloon flights

A description is given of a wide dynamic range pulse height analyzer system developed for use on High Energy Cosmic Ray Experiment (HECRE) Balloon Flights. A wide dynamic range of 100,000 is obtained by extending the range of a basic 1024 channel analyzer through the use of multiple ranges and range selection. The system described here contains four 100,000 pulse height analyzers. Each 100,000 pulse height analyzer consists of a group of cordwood welded modules mounted and interconnected on a printed circuit card. Four of these card assemblies, the required clock drive circuitry (discrete components mounted and interconnected on a separate card) and three input-output connectors are interconnected and mounted on the system board.

Cancro, C. A.↗