A Bayesian method for selecting data points for thermodynamic modeling of off-stoichiometric metal oxides
A novel Bayesian approach significantly accelerates data collection for metal oxide reduction/re-oxidation thermodynamic fitting.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A novel Bayesian approach significantly accelerates data collection for metal oxide reduction/re-oxidation thermodynamic fitting.
Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.
A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.
Cavities provide a means to manipulate the optical and electronic responses of quantum materials by selectively enhancing light-matter interaction at specific frequencies and momenta. While cavities typically involve external structures, exfoliated flakes of van der Waals (vdW) materials can form intrinsic self-cavities due to their small finite dimensions, confining electromagnetic fields into plasmonic cavity modes, characterized by standing-wave current distributions. While cavity-enhanced phenomena are well-studied at optical frequencies, the impact of self-cavities on nonlinear electronic responses—such as directional photocurrent—remains largely unexplored, particularly in the terahertz regime, critical for emerging ultrafast optoelectronic technologies. Here, we report a self-cavity-induced Purcell enhancement of directional photocurrents in the vdW semimetal WTe 2 . Using ultrafast optoelectronic circuitry, we measured coherent near-field THz emission resulting from nonlinear photocurrents excited at the sample edges. We observed enhanced emission at finite frequencies, tunable via excitation fluence and sample geometry, which we attribute to plasmonic interference effects controlled by the cavity boundaries. We developed an analytical theory that captures the cavity resonance conditions and spectral response across multiple devices. Our findings establish WTe 2 as a bias-free, geometry-tunable THz emitter and demonstrate the potential of self-cavity engineering for controlling nonlinear, nonequilibrium dynamics in quantum materials.
Coupling between microcracks and phase transformation in ion-conducting ceramics can jointly affect mechanical responses and ion transport. In this work we investigate the cubic-to-tetragonal phase transformation in Li₇La₃Zr₂O₁₂ in the presence of a microcrack under hydrostatic loading and quantify its implications for crack-tip stress concentration and Li-ion transport using phase-field and molecular dynamics simulations. The phase transformation exhibits a strong asymmetry between hydrostatic tension and compression. Under tension, the crack edge nucleates one tetragonal variant that amplifies the crack-tip stress intensity and promotes crack opening. Under compression, the crack tip nucleates a different tetragonal variant that enhances the stress-induced crack-closure tendency. Effective Li diffusivity analysis shows faster transport degradation under compression due to accelerated transformation kinetics, exposing a trade-off between mechanical stability and ionic conductivity. These results highlight the intertwined nature of cracking, phase transformation, and ionic transport in ion-conducting oxides and provide mechanistic insights into chemo-mechanical degradation of solid electrolytes.
In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.
CP-PAW is a combined electronic structure and ab initio molecular dynamics code to perform mixed quantum and classical simulations of atomistic condensed phase systems, such as solids, liquids, and molecular systems. As the name suggests, the CP-PAW code unifies the all-electron projector augmented-wave (PAW) method with the Car–Parrinello (CP) approach to determine not only the electronic and nuclear ground states of condensed matter but also to study their properties and dynamics. In addition to briefly outlining the underlying theory, the focus will be on the unique aspects of CP-PAW and how to correctly employ them as a user. How to install CP-PAW using the new build system will also be briefly mentioned.
Presentation at the Photocathode Physics for Photoinjectors Workshop (Arizona State University, Tempe, AZ, November 13, 2025) on the prospects for Ultra-Low MTE Photocathodes.
Explore the source record for details and available documents.
This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.
Endometriosis, defined as the ectopic growth of endometrial tissue outside of the uterine cavity, is an inflammatory and hormone-dependent disease that causes excruciating pelvic pain, infertility, and significantly decreases quality of life in affected patients. The JUN N-terminal kinases (JNKs) are a leading class of nonhormonal therapeutic targets that have been validated in preclinical models of endometriosis and in a Phase 1/2 clinical trial. Despite their therapeutic potential, JNK inhibitors with increased potency and specificity are needed to address the inflammatory pathology of endometriosis and to prevent disease progression. Leveraging a DNA-encoded chemical library collection of ~4 billion compounds, we identified lead inhibitor CDD-2428 and optimized derivatives, CDD-2728 and CDD-3013, with excellent binding affinity to JNK1-3 (K d = 0.12 to 3.7 nM), enhanced selectivity, metabolic stability, and cellular permeability. Crystallographic and biochemical studies confirmed that CDD-3013 exhibited superior kinase selectivity with improved efficacy compared to existing JNK inhibitors. In primary endometriosis cell models, CDD-2728 and CDD-3013 suppressed JNK-dependent inflammatory signaling, dampening pathways linked to pain, invasion, angiogenesis, and macrophage recruitment. In an endometriosis mouse model, both CDD-2728 and CDD-3013 reduced endometriotic lesion size, macrophage infiltration, and cellular proliferation, showing in vivo efficacy. When tested in a lipopolysaccharide-induced hyperalgesia model, CDD-2728 and CDD-3013 decreased markers of induced pain, as measured by changes in a dynamic weight bearing test and Grimace scores. These findings nominate CDD-2728 and CDD-3013 as potent, nonhormonal therapeutic candidates for endometriosis with broad anti-inflammatory and analgesic activity, addressing a critical unmet clinical need.
Explore the source record for details and available documents.
We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.
Explore the source record for details and available documents.
Requirements specific to hydrogen rail transportation and its unique components are currently not well represented in safety codes and standards. Notably, one of the most important components of the system, the hydrogen storage vessel, may be subject to entirely different shock and vibration conditions compared to hydrogen tanks on road vehicles. This report focuses on how composite hydrogen tanks are tested for performance and how this may relate to these tanks being used on rail systems. The shock and vibration testing procedures that are relevant for hydrogen composite tanks used for rail applications have been identified, as well as some general testing requirements for hydrogen tanks and composite tanks.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.