Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water Treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Upcycling Metal(loid) Contaminants to Produce Critical Raw Materials: The Nexus of Water Treatment and Material Criticality

The Critical Raw Materials Act adopted by the European Commission in 2024 signals a growing shift in the societal value of many elements, which has important implications for the water treatment sector. This legislation partly aims to increase production of Critical Raw Materials (CRMs) from waste streams, with many CRMs being elements with which the water sector has decades of experience, such as the notorious contaminant and newly classified CRM, arsenic. In this Perspective, we use arsenic as a case study to explore how water treatment waste can be repurposed to contribute to CRM supply chain requirements. Combining arsenic mass balances for indicative groundwater treatment plants and EU statistics of water use and arsenic compound consumption, we propose that arsenic upcycling integrated with water treatment can help offset imports of arsenic compounds. However, research is now needed to develop more holistic treatment systems that integrate CRM upcycling with contaminant removal and to better understand the political, institutional, and social drivers that can accelerate adoption of such systems at water utilities. With this work, we intend to stimulate a discussion of water treatment as a discipline that can both improve water quality by removing metal(loid) contaminants and generate local sources of CRMs.

Arsenic↗

Supercritical water desalination and oxidation (SCWDO): Effectiveness on complex solutions, technoeconomic, and CO 2 impact for produced water treatment

The modern energy-economy is increasingly causing the production of highly saline brines, including from produced water. Supercritical water desalination can concentrate and extract minerals from these brines, but the effects of mixed salt interactions, organic degradation with additives, and the technology's economics are not well understood at supercritical condition. The present study evaluated and experimentally studied an integrated supercritical water desalination and oxidation (SCWDO) process for treating real-produced water samples from oil/natural gas field. The complex interactions between the various anions and cations in produced water were extensively evaluated. Most of the divalent and trivalent ions were extracted below 250 °C while the majority of the monovalent salt were removed between 380 to 410 °C. The treated real produced water was of drinking water quality, with <500 mg/l of total dissolved solid (TDS) and with 100% organics removal. Furthermore, the heat liberated during the organic oxidation could be utilized internally and for electricity generation for enhanced the energy efficiency and lower cost of produced water treatment. With system optimization, the proposed SCWDO process can essentially be made a net zero energy process. A novel process flow diagram for the commercial scale self-powered hybrid SCWDO technology was proposed as a cost-effective produced water treatment to mitigate the environmental crises. Techno-economic analysis showed that produced water treatment cost with SCWDO can be reduced to 2–3 $/m 3 and can be up to 60 % cheaper to traditional deep well reinjection. Additionally, the proposed SCWDO process could achieve net negative CO 2 emission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream

Changes in climate, season, and vegetation can alter organic export from watersheds. While an accepted tradeoff to protect public health, disinfection processes during drinking water treatment can adversely react with organic compounds to form disinfection byproducts (DBPs). By extension, DBP monitoring can yield insights into hydrobiogeochemical dynamics within watersheds and their implications for water resource management. In this study, we analyzed temporal trends from a water treatment facility that sources water from Coal Creek in Crested Butte, Colorado. These trends revealed a long-term increase in haloacetic acid and trihalomethane formation over the period of 2005-2020. Additionally, disproportionate export of dissolved organic carbon and formation of DBPs that exceeded regulatory guidelines were consistently recorded in association with late spring freshet. Synoptic sampling of the creek in 2020 and 2021 identified a biogeochemical hotspot for organic carbon export in the upper domain of the watershed that contained a prominent fulvic acid-like fluorescent signature. DBP formation potential analyses from this domain yielded similar ratios of dominant DBP species to those formed at the drinking water facility. Spectrometric qualitative analyses of pre and post-reacted waters with hypochlorite indicated ligninlike and condensed hydrocarbon-like molecules were the major reactive chemical classes during chlorine-based disinfection. This study demonstrates how drinking water quality archives can be coupled with synoptic sampling to identify and understand export control points for dissolved organic matter. Resultant understanding can be applied in water treatment and watershed management plans to improve drinking water quality sourced from analogous watersheds.

47 OTHER INSTRUMENTATION↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

Covalent Organic Frameworks for Water Treatment

Covalent organic frameworks (COFs) are an emerging type of porous crystalline material with highly ordered aperture size and tunable structures with designer properties. COFs have been proposed as promising materials for water treatment because of their notable intrinsic properties like excellent chemostability, high surface area, abundant functional sites, and uniform adjustable aperture size. This review focuses on fundamental COF design principles for water treatment (stability, aperture size, and surface functionalization) and the state-of-the-art application of COFs in desalination, organic contaminant sorption, and ion capture. Additional potential promising applications of COFs for water treatment, including solar steam generation, photocatalysis for degradation of organic contaminants, and capacitive deionization are also presented along with an outlook toward future opportunities in the field.

36 MATERIALS SCIENCE↗

Techno-economic assessment of distributed wellhead RO water treatment for nitrate removal and salinity reduction: A field study in small disadvantaged communities

Techno-economic analysis of distributed wellhead water treatment and desalination (DWTD) systems was carried out based on a three-year field study in three small, disadvantaged communities (DACs) to evaluate the reliability and affordability of upgrading their impaired well water. The local water supplies of the three study DACs, located in Salinas Valley, California, were contaminated with nitrate at levels (~ 12–87 mg/L NO$^{-}_{3}$ - N) ) above the California maximum contaminant level (MCL) of 10 mg/L NO$^{-}_{3}$ - N , and had elevated water salinity (~600–1,600 mg/L total dissolved solids(TDS)) above its secondary MCL (SMCL) of 500 mg/L TDS. Well water nitrate removal and salinity reduction were accomplished via reverse osmosis (RO) based DWTD systems that operated autonomously, supported by remote monitoring and supervisory cyberinfrastructure. Reliable DWTD operation provided treated water quality, with respect to nitrate and salinity, in the range of 0.5–6.3 mg/L NO$^{-}_{3}$ - N and 57–161 mg/L TDS, respectively, which were well below the respective MCL and SMCL. The levelized cost of water treatment was in the range of ~$$2/m 3 - $$2.9/m 3 which aligns with typical residential water costs in California and in the study region, and monthly residential water costs (39 dollars-74 dollars/residential unit/month) were also within the range in California. The study showcased the DWTD approach as a viable and potentially scalable solution for upgrading impaired local potable water supply of communities lacking centralized water delivery infrastructure. However, streamlined permitting processes and standardized regulatory frameworks are critical to promoting wider adoption and maximizing the socio-economic benefits of the DWT approach. Moreover, DACs are likely to require government subsidies in order to cover the CapEx of DWTD systems in addition to upgrade of site infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrocoagulation in Water Treatment: Targeted Contaminant Removal and Laboratory Best Practices

Electrocoagulation for water treatment offers many advantages over traditional treatment technologies, including improved energy efficiency and modularity. One challenge with electrocoagulation is the lack of standardization in the methodology and reporting. This review provides a novel contribution by examining the past literature using a uniform metric (charge loading) as a basis for comparison, highlighting the importance of uniform reporting practices in this field. Furthermore, this review provides practical guidance for experimentalists in standardizing the electrocoagulation design and operating procedures. First, we present a comprehensive overview of contaminant-specific electrocoagulation as an electrochemical treatment technology for processing industrial, municipal, and agricultural water, with a focus on aluminum and iron electrocoagulation. We detail the fundamental mechanisms that allow for constituent removal during pretreatment. Specifically, we highlight electrocoagulation’s potential for organics, metalloids, microbes, and hardness remediation, examining the optimal removal conditions in terms of charge loading and current density. We conclude this work with some experimental best practices for lab-scale electrocoagulation experiments.

aluminum↗

Surface Water Disinfection Byproducts and Organic Matter Characterization Data Associated with: “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream”

This dataset is associated with the publication “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream” published in Water Research X (Leonard et al. 2022; https://doi.org/10.1016/j.wroa.2022.100144). The associated study analyzed temporal trends from the Town of Crested Butte water treatment facility and synoptic sampling at Coal Creek in Crested Butte, Colorado, US. This work demonstrates how drinking water quality archives combined with synoptic sampling and targeted analyses can be used to identify and understand export control points for dissolved organic matter. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) metadata and international geo-sample number (IGSN) mapping file; (4) dissolved organic carbon (DOC), ultraviolet absorbance at 254 nanometers (UV254), total nitrogen (TN), and specific ultraviolet absorbance (SUVA) data; (5) disinfection bioproduct formation potential (DBP-FP) data; (6) readme; (7) methods codes; (8) water collection protocol; (9) folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory); and (10) folder of excitation emissions matrix (EEM) spectra. The FTICR folder contains a file of DOC (measured as non-purgeable organic carbon; NPOC) used for FTICR sample preparation. The FTICR folder also contains three subfolders: one subfolder containing the raw .xml data files, one containing the processed data, and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .dat, .R, .ref, or .xml

54 ENVIRONMENTAL SCIENCES↗

GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} for Fukushima Daiichi Water Treatment Secondary Wastes - 20212

The Japanese government is supporting development work implemented jointly by Veolia subsidiaries Kurion Japan, K.K., Veolia Nuclear Solutions (VNS), Inc., and Veolia Nuclear Solutions Federal Services, LLC for treating radioactive waste generated from Fukushima Daiichi Nuclear Power Station (NPS) water treatment using the GeoMelt{sup TM} In-Container Vitrification (ICV){sup TM} technology. The initial work consisted of glass formulation and engineering-scale testing which was completed in 2018, in the frame of an IRID (International Research Institute for Nuclear Decommissioning) program as part of a project subsidized by Japan's Ministry of Economy, Trade and Industry (METI). The Fukushima Daiichi NPS Mid- and Long-Term Road-map requires investigation of methods to stabilize solid wastes (and to immobilize radioisotopes in the wastes) generated as a result of emergency response and decommissioning activities. Cooling water treatment has resulted in a significant amount of solid and slurry secondary wastes (mostly adsorbents and ion-exchange materials) which will require processing at some point. GeoMelt{sup R} ICV{sup TM} is a joule-heated melter technology which uses a refractory-lined single-use container combining the melter and disposal container. There is no pouring required nor concerns with refractory corrosion which allows the process to accommodate a wide range of waste chemistries and high waste loadings. The testing described here consisted of three engineering-scale melts, each processing between 212 kg and 240 kg of waste simulants, glass formers, and non-radioactive cesium (Cs) and strontium (Sr) tracers. Continuous isokinetic stack sampling of off-gas emissions was performed for each test in order to calculate Cs and Sr retention in the glass wasteform. Single-pass retention of Cs in the final glass wasteform ranged from 91.46 to 99.30%, and single-pass retention of Sr ranged from 99.76 to 100%. Planned particulate recycle will increase these retention levels. Melt 1 processed a mixture of KUR-EH (a zeolite-based ion-exchange material), simulated Advanced Liquid Processing System (ALPS) Carbonate and Iron Slurries, and glass additives. Melt 2 processed a mixture of KUR-EH, KUR-TSG (a titanate-based adsorbent), and glass additives. Melt 3 processed a mixture of KUR-EH, simulated barium sulfate/iron ferrocyanide sludge (AREVA sludge), and glass additives. Waste loadings for these melts ranged from 70 weight percent (wt%) to 82 wt%. Vitrification produces a waste form much denser than the stored water treatment secondary waste wastes, resulting in significant volume reduction. Volume reductions for the three tests ranged from 74 to 79 vol%. Vitrification produces a chemically durable wasteform. Pacific Northwest National Laboratory (PNNL) tested three glass samples from each engineering-scale melt) by the Materials Characterization Center 1 (MCC-1) test, an international standard leach test of the chemical durability of nuclear waste glasses. PNNL also obtained one U.S. reference glass (EA Glass) and two Japan reference glasses P0798) and tested these under the same MCC-1 conditions (90 deg. C, 10 m-1, DIW, and 7, 14, 28-day) as the GeoMelt{sup R} ICV{sup TM} glasses. The GeoMelt{sup R} ICV{sup TM} glasses exhibited lower total normalized releases and 14- to 28-day normalized release rates than the three reference glasses. These results suggest that the GeoMelt{sup R} ICV{sup TM} glasses have durabilities on par with high-level waste glasses under standard test conditions. Post-melt process sampling and analysis indicated no Cs migration into the melter refractory materials and very little deposition of Cs or Sr onto the melter hood or off-gas piping internals. The results of the testing indicated good Cs retention in the glass, high volume reduction and waste loadings, and excellent chemical durability. These factors are important to minimize treatment costs and to protect workers and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Parameter Sweep in WaterTAP to Analyze New Water Treatment Technologies

We describe a powerful and generalized parameter sweep tool in this report that was originally developed to analyze the performance of existing and novel water treatment models being developed in WaterTAP. Since WaterTAP is built upon IDAES and Pyomo, the parameter sweep tool can be used to systematically explore and debug the behavior of most Pyomo and IDAES numerical models. In order to enable meaningful analyses, the parameter sweep tool has been designed with the following features: 1) Model flexibility: The parameter sweep tool does not enforce any restrictions on the types of models that can be used with it. As long as a Pyomo model can be solved and the parameter is active and mutable, the tool only needs functions that describe how to run the model, the sweep parameters, and the output quantities of interest. 2) Flexible sampling: The parameter sweep tool has inbuilt functions to generate samples from a random distribution or a multidimensional Euclidean space. Furthermore, the users have to ability to supply samples generated from a tool of their choice. 3) Multiple sweep types: A user can choose from one of 3 types of parameter sweeps depending on their needs. 4) Detailed outputs: Outputs generated by the parameter sweep tool can be stored in detailed H5 file or user-friendly CSV files for post processing. 5) Parallel computing: The parameter sweep supports shared and distributed memory parallel computing to enable the use of high performance computers (HPC) for large-scale analyses. 6) Modular: The parameter sweep tool is self-contained and can easily be integrated within an outer-loop analysis or as desired by the user. 7) Ease of use: The tool is well documented and a simple sweep can be easily executed by following the online documentation in a few lines of code. We demonstrate the use of the parameter sweep tool on a simple water treatment system from the WaterTAP repository and show its parallel scaling performance on an Apple laptop and NREL's Eagle HPC. The parameter sweep tool is actively being used with models currently being developed within WaterTAP and we expect its use to grow beyond it to other IDAES and Pyomo models.

97 MATHEMATICS AND COMPUTING↗

The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation

Drinking water treatment residuals (DWTRs) are complex mixtures of organic and inorganic phases generally disposed of as waste materials. However, their strong sorptive properties could be further exploited to immobilize contaminants. To characterize these materials, we applied a range of analytical techniques to a set of aluminum-based DWTRs. Here we determined surface areas, elemental compositions using CHNS analysis and X-ray fluorescence (XRF), performed thermogravimetric analyses paired with mass spectrometry (TGA-MS), and used synchrotron-based methods: X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Elemental analyses and specific surface area measurements – that vary between 7.23 ± 0.03 and 197.6 ± 0.9 m 2 g –1 – indicate that non-coagulant additives must play an important role in controlling sorption. High resolution powder XRD reveals the presence of only a few crystalline minerals mostly derived from source waters or additives. Fe was detected by XRF in all samples, whereas Mn was present in significant levels in samples with potassium permanganate as additive. The chemical speciation of these elements was characterized by performing spectral decompositions of XAS spectra. The spectral features of Fe are consistent with iron(III) oxides/hydroxides and structural iron in clays. On the other hand, Mn is predominantly present under its reduced form, Mn(II).

54 ENVIRONMENTAL SCIENCES↗

DEM and MELT In-Can Vitrification Process for Fukushima Daiichi Water Treatment Secondary Waste - 20034

Fukushima Daiichi Nuclear Power Station was severely damaged by a tsunami induced by the earthquake on March 11, 2011. A large amount of water treatment secondary waste has been generated from the purification work of contaminated water that consists of the water flowing into the reactor building. The Mid and Long-Term Road map specifies that solid waste at Fukushima Daiichi Nuclear Power Station should be stored safely and reasonably according to its characteristics. In order to meet this goal, a versatile treatment solution is needed, and the In-Can vitrification seems to be a suitable solution. The DEM and MELT In-Can vitrification process is being developed and qualified in France to treat waste arising from decommissioning and dismantling operations. This qualification is carried out through the consortium of the DEM and MELT project coordinated by CEA which gathers Orano, ECM technologies and Andra. The DEM and MELT In-Can vitrification process is a robust, simple and versatile in situ vitrification process. It is designed for high or intermediate level waste and is compact enough to be implemented in an existing facility or close to the waste to be treated. It is developed to treat liquid and solid waste, to produce a small amount of secondary waste and to minimize investment and operating costs. The DEM and MELT In-Can vitrification process is also developed with a modular design in order to be adapted to nuclear operators needs and requirements. The In-Can melting process has already been developed and fully qualified by the CEA for Alpha liquid waste and can be rated TRL 7 for this scope. The In-Can vitrification technology is considered as a qualified solution that could be applied for the treatment of waste resulting from the D and D work in Fukushima Daiichi Nuclear Power Station. The feasibility evaluation of the DEM and MELT In-Can vitrification process for Fukushima Daiichi water treatment secondary waste is a project led by Orano, CEA and ANADEC. This R and D project is performed by the funds from the Ministry of Economy, Trade and Industry as The Subsidy Program 'Project of Decommissioning and Contaminated Water Management'. This paper presents the first results of this feasibility evaluation, from the scenarios and glass formulation definition to the industrial implementation feasibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opportunities and Challenges for Industrial Water Treatment and Reuse

As the impact of water scarcity in the United States (U.S.) continues to grow through the 21st century, it is critical to develop strategies to reduce water use and improve the security of water resources. One such strategy is to diversify the sources from which water is supplied. Industrial withdrawals represent the fourth largest category of U.S. water use, the majority of which is sourced from fresh surface and groundwater. In this study, we critically explore the potential of industrial wastewater to serve as an alternative water resource through direct treatment and reuse. We begin by reviewing the state of the art of water use, treatment, and reuse across six representative industries: food and beverages, primary metals, pulp and paper, petroleum refining, chemicals, and data centers and campuses, highlighting key challenges and opportunities toward the expansion of reuse. We then employ a technoeconomic assessment of water treatment processes to analyze the capital investment, operating and maintenance costs, levelized cost of water, and electricity consumption of three specific industrial plants as case studies to better understand where research can promote impactful innovation. Finally, drawing together the results of our literature review and technoeconomic analyses, we provide a broad outlook on the future of industrial water reuse and discuss strategies for its expansion.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In Situ Polymerization of Polypyrrole and Polyaniline on the Surface of Magnetic Molybdenum Trioxide Nanoparticles: Implications for Water Treatment

Photocatalyst dissolution greatly diminishes the usability of photocatalysts in water treatments. Coating conductive polymers on the surface of photocatalysts can reduce dissolution without compromising the photocatalytic properties of the material. In this investigation, polypyrrole (PPy) and polyaniline (PANI) were used to coat two magnetic MoO 3 nanoparticles with different surface chemistries. The polymer-coated MoO 3 @Fe 3 O 4 nanoparticles were synthesized by optimizing the mole fractions of PPy or PANI, MoO 3 , and Fe 3 O 4 . The optimized PPy@ MoO 3 @Fe 3 O 4 (PMF1) and PANI@MoO 3 @Fe 3 O 4 (PMF2) resulted in 95.39 and 75.98% methylene blue dye removal, respectively. MoO 3 dissolutions of 4.12 and 5.6% were obtained for PMF1 and PMF2, respectively, demonstrating the reduced solubility of the coated nanoparticles as compared to their uncoated counterparts (7.87% for MF1 and 18.1% for MF2). In situ small-angle neutron scattering (SANS) was utilized to investigate the polymerization kinetics of PPy and PANI on nanoparticles. The results revealed that an increase in base material oxygen vacancies resulted in the reduction of both the polymer size and the polymerization rate. Furthermore, this study demonstrated that SANS provides valuable insights into the polymer growth mechanisms on nanoparticle surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗