Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WTG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Wind and turbine characteristics needed for integration of wind turbine arrays into a utility system

Wind data and wind turbine generator (WTG) performance characteristics are often available in a form inconvenient for use by utility planners and engineers. The steps used by utility planners are summarized and the type of wind and WTG data needed for integration of WTG arrays suggested. These included long term yearly velocity averages for preliminary site feasibility, hourly velocities on a 'wind season' basis for more detailed economic analysis and for reliability studies, worst-case velocity profiles for gusts, and various minute-to-hourly velocity profiles for estimating the effect of longer-term wind fluctuations on utility operations. wind turbine data needed includes electrical properties of the generator, startup and shutdown characteristics, protection characteristics, pitch control response and control strategy, and electro-mechanical model for stability analysis.

Park, G. L.↗

Utility experience with two demonstration wind turbine generators

Edison has committed 360 MW of nameplate generating capacity to wind energy by year 1990 in its long-range generation plan. To reach this goal the Company's wind energy program focuses on three areas: the continuous evaluation of the wind resource, the hands-on demonstration of wind turbine generators (WTG) and an association with wind park developers. Two demonstration WTGs have been installed and operated at Edison's Wind Energy Center near Palm Springs, California: a 3 MW horizontal axis Bendix/Schachle WTG and a 500 kW vertical axis Alcoa WTG. They are part of a one to two year test program during which the performance of the WTGs will be evaluated, their system operation and environmental impact will be assessed and the design criteria of future WTGs will be identified. Edison's experience with these two WTGs is summarized and the problems encountered with the operation of the two machines are discussed.

Wehrey, M. C.↗

Techno-economic performances and life cycle greenhouse gas emissions of various ammonia production pathways including conventional, carbon-capturing, nuclear-powered, and renewable production

Ammonia (NH 3 ) is conventionally produced using fossil natural gas (NG) for hydrogen production through steam reformation and synthesis in the Haber–Bosch (HB) process. The global conventional ammonia production contributes more than 420 million tons of CO 2 emissions annually. Here, in this work, we investigated the techno-economics and well-to-plant-gate (WTG) greenhouse gas (GHG) emissions of conventional NG-based, carbon-capturing, nuclear-powered, and renewable ammonia production by developing an engineering process model for each. Carbon-capturing ammonia production refers to the NG-based ammonia production while capturing CO 2 and transporting it via pipelines for storage or utilization. Nuclear-powered and renewable ammonia production represents an alternative ammonia production through water electrolysis, air separation, and the HB process using carbon-free energy sources. Nuclear and renewable energy sources are assumed to be used for nuclear-powered and renewable ammonia production, respectively. Sensitivity analyses are performed for CO 2 pipeline transport distances, potential carbon capture tax credits, and clean H 2 production cost. Carbon-capturing ammonia production reduces WTG GHG emissions by 55–70% compared to conventional NG-based ammonia production methods. Nuclear-powered and renewable ammonia production almost eliminate GHG emissions since energy supply is either zero carbon or near-zero carbon. However, when $4.16–4.83 per kg is the cost assumed for clean H 2 production using state-of-the-art electrolysis technologies, the levelized costs of nuclear-powered and renewable ammonia are calculated to be $0.92–1.06 per kg NH 3 , which are approximately four times higher than the conventional NG-based ammonia production cost. The cost of CO 2 emission avoidance is estimated in the range of $266–318 per metric ton of CO 2 for nuclear-powered and renewable ammonia production. The clean H 2 production cost is the major contributor to the levelized costs of nuclear-powered and renewable ammonia production. A lower production cost, near $1 per kg H 2 , for clean H 2 is required for nuclear-powered and renewable ammonia production to be cost-competitive with conventional NG-based ammonia production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control and stabilization of the DOE/NASA Mod-1 two megawatt wind turbine generator

This paper describes the controls design, performance simulation process and specialized dynamic considerations for the DOE/NASA Mod 1 wind turbine generator (WTG). It shows controls, structural and utility interface considerations of the wind turbine generator and shows how a wind turbine generator can be integrated with a synchronous power system. Differences with respect to fossil or hydro generation and their implications are vital to long-term WTG reliability and availability and acceptance by utilities and consumers. The paper describes the control performance requirements to provide stable pitch and excitation control with drivetrain torsional dynamics, and the control of power swing stability and utility feeder voltage due to wind gusts.

Barton, R. S.↗

Low cost composite materials for wind energy conversion systems

A winding process utilizing a low-cost E-glass fabric called transverse-filament tape for low-cost production of wind turbine generators (WTG) is described. The process can be carried out continuously at high speed to produce large one-piece parts with tapered wall thicknesses on a tapered mandrel. It is being used to manufacture blades for the NASA/DOE 200-ft-diameter MOD-1 WTG and Rockwell/DOE 40-kW small wind energy conversion system (SWECS).

Weingart, O.↗

Scale Analysis of Moist Thermodynamics in a Simple Model and the Relationship Between Moisture Modes and Gravity Waves

Observations and theory of convectively-coupled equatorial waves suggest that they can be categorized into two distinct groups. Moisture modes are waves whose thermodynamics are governed by moisture fluctuations. The thermodynamics of the gravity wave group, on the other hand, are rooted in buoyancy (temperature) fluctuations. On the basis of scale analysis it is found that a simple nondimensional parameter –akin to the Rossby number– can explain the processes that lead to the existence of these two groups. This parameter, defined as Nmode, indicates that moisture modes arise when anomalous convection lasts sufficiently long so that dry gravity waves eliminate the temperature anomalies in the convective region, satisfying weak temperature gradient (WTG) balance. This process causes moisture anomalies to dominate the distribution of moist enthalpy (or moist static energy), and hence the evolution of the wave. Conversely, convectively-coupled gravity waves arise when anomalous convection eliminates the moisture anomalies more rapidly than dry gravity waves can adjust the troposphere towards WTG balance, causing temperature to govern the moist enthalpy distribution and evolution. Spectral analysis of reanalysis data indicates that slowly-propagating waves (cp ~ 3 m s-1) are likely to be moisture modes while fast waves (cp ~ 30 m s-1) exhibit gravity wave behavior, with "mixed moisture-gravity" waves existing in between. While these findings are obtained from a highly idealized framework, it is hypothesized that they can be extended to understand simulations of convectively-coupled waves in GCMs and the thermodynamics of more complex phenomena.

Angel F Adames↗

Is the Madden-Julian Oscillation a Moisture Mode?

The governing thermodynamics of the Madden-Julian Oscillation (MJO) is examined using sounding and reanalysis data. On the basis of four objective criteria, results suggest that the MJO behaves like a moisture mode-a system whose thermodynamics is governed by moisture-only over the Indian Ocean. Over this basin, the MJO shows a slow convective adjustment timescale, its zonal scale is smaller, and it exhibits slow propagation, allowing moisture modes to exist. Elsewhere, the faster-propagating wavenumber 1-2 components are more prominent preventing weak temperature gradient (WTG) balance to be established. As a result, temperature and moisture play similar roles in the MJO's thermodynamics outside the Indian Ocean.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Environmental Effects Assessment for Proposed Offshore Wind Farm off the Coast of Grays Harbor, Washington

Grays Harbor Wind LLC (GHW) is proposing to develop a floating offshore wind farm offshore of west Grays Harbor County, Washington (Grays Harbor). The proposed GHW Offshore Wind Project (Project) would entail construction, installation and operation of a 1,000-megawatt (MW) offshore wind farm consisting of approximately 75 floating units, each containing a floating foundation and wind turbine generator (WTG). The Project location is approximately 25 miles (21.7 nautical miles [nmi]) offshore west of Grays Harbor, at waters depths of 360 to 700 feet. The Pacific Northwest National Laboratory (PNNL) was contracted by Herrera Environmental Consultants, Inc. on behalf of GHW to carry out this preliminary scoping study to evaluate baseline conditions and potential effects on fish and marine mammals from development and operation of a floating offshore wind farm installed within a designated area off the coast of Washington1. Floating offshore wind units installed in an ocean environment as part of the Project would interact with marine wildlife. This Study report provides an initial data aggregation and analysis, using publicly available data, of the Project effects, both negative and positive, on the marine environment. The scope of this assessment is limited by the fact that the Project development is presently at the conceptual level. Data on marine organisms were aggregated and evaluated; however seabirds were evaluated by Herrera Environmental Consulting and, along with bats, were not included in the scope of this study. Significant additional work is necessary to characterize ocean, seafloor, and environmental conditions; select appropriate floating offshore wind technologies; identify construction methods and locations; and assess facility locations, including electrical interconnection. Data aggregation and analysis of seabirds and bats is also needed. Evaluation of the full range of potential environmental effects would be conducted following an award of a lease from the Bureau of Ocean Energy Management (BOEM) as part of the leasing, National Environmental Policy Act (NEPA)/State Environmental Policy Act (SEPA) environmental review and permitting processes. While this initial data aggregation and analysis uses best available public scientific information and current assumptions about the Project configuration, the effects discussed herein are based on the status of review to-date and may change as Project-specific details are developed.

17 WIND ENERGY↗

Land-Based Wind Reference Architecture

This report describes a summary and the final deliverables for the Wind Reference Architecture project funded by the Department of Energy's (DOE) Wind Energy Technology Office (WETO). The project objective was to further refine the reference architecture of the existing wind power plant reference architecture developed by Idaho National Laboratory (INL) and Sandia National Laboratories (SNL) by expanding the wind turbine generator (WTG) into a separate individual wind turbine reference architecture. Additional details regarding the wind turbine system and how it integrates with a wind power plant were researched and reflected in the reference architecture. This addition is important because it allows researchers to understand the components and devices in a wind turbine, how they function and how a wind turbine integrates into a wind power plant to be able to perform cybersecurity evaluations on the system. The communication and control systems were the focus while developing this reference architecture to understand the cybersecurity posture of a wind turbine and power plant. The information technology (IT) and operational technology (OT) systems perspective are integral in helping improve the cybersecurity posture by creating a starting point to study how wind energy can be safely designed and deployed in our power grid from an integrated systems standpoint. A holistic wind power plant and turbine reference architecture and simulation was developed and made open-sourced for further research efforts.

17 WIND ENERGY↗

An operating 200 kW horizontal axis wind turbine

Output from the 200-kilowatt machine will be enough to meet the power requirements of about 60 families. The experimental wind turbine generator (WTG) is a two-bladed, horizontal-axis, rotor system driving a synchronous electric generator through a step-up gear box located within a nacelle. The nacelle is mounted on top of a 100-foot tower with the rotor located downwind from the tower. The 200-kilowatt rated power output of the wind turbine is achieved at a turbine rotor speed of 40 rpm and a rated wind speed of 18.3 mph. The rated wind speed is defined as the lowest wind speed at which full power is achieved. Attention is given to operational details, aspects of blade design, blade fabrication, the use of strain gages, questions of aeroelastic stability, and an early analysis of test data.

Hunnicutt, C. L.↗

MOD-2 wind turbine farm stability study

The dynamics of single and multiple 2.5 ME, Boeing MOD-2 wind turbine generators (WTGs) connected to utility power systems were investigated. The analysis was based on digital simulation. Both time response and frequency response methods were used. The dynamics of this type of WTG are characterized by two torsional modes, a low frequency 'shaft' mode below 1 Hz and an 'electrical' mode at 3-5 Hz. High turbine inertia and low torsional stiffness between turbine and generator are inherent features. Turbine control is based on electrical power, not turbine speed as in conventional utility turbine generators. Multi-machine dynamics differ very little from single machine dynamics.

Hinrichsen, E. N.↗

Conceptual design of the 6 MW Mod-5A wind turbine generator

The General Electric Company, Advanced Energy Programs Department, is designing under DOE/NASA sponsorship the MOD-5A wind turbine system which must generate electricity for 3.75 cent/KWH (1980) or less. During the Conceptual Design Phase, completed in March, 1981, the MOD-5A WTG system size and features were established as a result of tradeoff and optimization studies driven by minimizing the system cost of energy (COE). This led to a 400' rotor diameter size. The MOD-5A system which resulted is defined in this paper along with the operational and environmental factors that drive various portions of the design. Development of weight and cost estimating relationships (WCER's) and their use in optimizing the MOD-5A are discussed. The results of major tradeoff studies are also presented. Subsystem COE contributions for the 100th unit are shown along with the method of computation. Detailed descriptions of the major subsystems are given, in order that the results of the various trade and optimization studies can be more readily visualized.

Barton, R. S.↗

Control design and performance analysis of a 6 MW wind turbine-generator

This paper discusses an approach to the modeling and performance for the preliminary design phase of a large (6.2 MW) horizontal axis wind turbine generator (WTG). Two control philosophies are presented, both of which are based on linearized models of the WT mechanical and electrical systems. The control designs are compared by showing the performance through detailed non-linear time simulation. The disturbances considered are wind gusts, and electrical faults near the WT terminals.

Murdoch, A.↗

Design and dynamic simulation of a fixed pitch 56 kW wind turbine drive train with a continuously variable transmission

The dynamic analysis of a horizontal axis fixed pitch wind turbine generator (WTG) rated at 56 kW is discussed. A mechanical Continuously Variable Transmission (CVT) was incorporated in the drive train to provide variable speed operation capability. One goal of the dynamic analysis was to determine if variable speed operation, by means of a mechanical CVT, is capable of capturing the transient power in the WTG/wind environment. Another goal was to determine the extent of power regulation possible with CVT operation.

Gallo, C.↗

Advanced Lightweight HiE PMDD Generator for WTGs

Preliminary designs of advanced lightweight permanent magnet direct drive generators for offshore and “tall wind” onshore applications utilizing funding from DOE/EERE/WETO were developed by WEG, RTX, NREL and supporting partners. This work significantly reduces tower head mass, increases efficiency, reduces the rare earth content of the generator, and leads to additional turbine system benefits that improve competitiveness, such as the use of taller towers onshore and less expensive foundations (“hull”) for floating offshore. The end result is an approximately 10% reduction of LCOE in both cases, which could significantly improve competitiveness and support the EERE/DOE goal of promoting US manufacturing.

17 WIND ENERGY↗