Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of Pseudomonas aeruginosa and Acinetobacter calcoaceticus-baumannii complex traumatic wound isolates

Healing of traumatic wounds is complicated by infecting pathogens, with Pseudomonas aeruginosa and members of the Acinetobacter calcoaceticus-baumannii complex among the most common infectious agents. However, a full understanding of genotypic and phenotypic differences between circulating wound isolates is lacking. To address this, traumatic wounds were sampled at Emory University Hospital, and 24 isolates were characterized; we focused on P. aeruginosa and Acinetobacter due to their prevalence and tendency for antibiotic resistance. Even though these species are renowned for antibiotic resistance, only two of the tested isolates could be classified as multidrug resistant. Whole-genome sequencing and analysis revealed that isolates from different patients were genetically distinct; however, longitudinal isolates from the same patient were closely related and appeared to represent chronic colonization by the same strain. Phylogenetic analysis revealed that laboratory strains (PAO1 and AB5075) that were isolated decades previously and from different locations grouped closely to subsets of the recent wound isolates. Given the importance of biofilm formation in infection, the ability of the isolates to form biofilms was assessed; all isolates formed biofilms but showed temporal and magnitude differences. Analysis of a subset of isolates revealed that planktonic P. aeruginosa was resistant to human serum-mediated killing. While the same was true for the majority of Acinetobacter isolates, one showed planktonic sensitivity that was abrogated when grown in a biofilm. Taken together, these data reveal genotypic and phenotypic differences in circulating isolates of P. aeruginosa and A. baumannii.

Acinetobacter↗

Compressive behavior of undulations in filament-wound composites

The compressive performance of a filament-wound cylinder can be severely degraded by unavoidable fiber curvatures due to the presence of crossover bands. These crossover bands contain fiber undulations which influence the compressive strength, stiffness, and associated failure mechanisms of a filament-wound structure. The primary objectives of this study were to identify failure mechanisms and measure the compressive strength and stiffness of test specimens which model the microundulations. Compressive tests were conducted on flat-panel coupons which were developed to model the mechanics of large-scale fiber undulation regions in filament-wound composite cylinders. The primary effect of the undulation regions within a filament-wound structure is to initiate failure. Depending on the overall laminate configuration, the failure process includes various combinations of failure mechanisms, such as delaminations, matrix splitting and/or fiber fracture. These failure mechanisms are aggravated by the presence of large deformations caused by the reduction in local compressive stiffness and the introduction of complex material couplings due to the fiber undulation. Furthermore, the adjacent layers have been shown to strongly influence the compressive strength, stiffness, and associated failure mechanisms by weakening or reinforcing the laminate.

Jensen, David W.↗

Impact damage in filament wound composite bottles

Increasingly, composite materials are being used in advanced structural applications because of the significant weight savings they offer when compared to more traditional engineering materials. The higher cost of composites must be offset by the increased performance that results from reduced structural weight if these new materials are to be used effectively. At present, there is considerable interest in fabricating solid rocket motor cases out of composite materials, and capitalizing on the reduced structural weight to increase rocket performance. However, one of the difficulties that arises when composite materials are used is that composites can develop significant amounts of internal damage during low velocity impacts. Such low velocity impacts may be encountered in routine handling of a structural component like a rocket motor case. The ability to assess the reduction in structural integrity of composite motor cases that experience accidental impacts is essential if composite rocket motor cases are to be certified for manned flight. While experimental studies of the post-impact performance of filament wound composite motor cases haven been proven performed (2,3), scaling impact data from small specimens to full scale structures has proven difficult. If such a scaling methodology is to be achieved, an increased understanding of the damage processes which influence residual strength is required. The study described herein was part of an ongoing investigation of damage development and reduction of tensile strength in filament wound composites subjected to low velocity impacts. The present study, which focused on documenting the damage that develops in filament wound composites as a result of such impacts, included two distinct tasks. The first task was to experimentally assess impact damage in small, filament wound pressure bottles using x-ray radiography. The second task was to study the feasibility of using digital image processing techniques to assist in determining the 3-D distribution of damage from stereo x-ray pairs.

Highsmith, Alton L.↗

Methods and apparatus for microwave tissue welding for wound closure

Methods and apparatus for joining biological tissue together are provided. In at least one specific embodiment, a method for joining biological tissue together can include applying a biological solder on a wound. A barrier layer can be disposed on the biological solder. An antenna can be located in proximate spatial relationship to the barrier layer. An impedance of the antenna can be matched to an impedance of the wound. Microwaves from a signal generator can be transmitted through the antenna to weld two or more biological tissue pieces of the wound together. A power of the microwaves can be adjusted by a control circuit disposed between the antenna and the signal generator. The heating profile within the tissue may be adjusted and controlled by the placement of metallic microspheres in or around the wound.

Arndt, G. Dickey↗

Filament Wound Composite Analysis Using the NASA Multiscale Analysis Tool (NASMAT) and Finite Element Analysis

Fiber reinforced composite materials, owing to their tailorable thermomechanical and functional properties, allow one to produce a structure that is stronger, stiffer, and lighter than its metal counterpart while performing the same function, yielding a more efficient structure. This not only allows for the improvement of current technologies like aircraft structures, but also enables new technologies like gaseous hydrogen storage for mobility applications, which are otherwise impractical when manufactured using traditional metals due to weight and space restrictions or material embrittlement. However, the use of composites imposes greater design and manufacturing challenges on an engineer, since they are heterogenous, having a distinct structure across multiple length scale, behave generally anisotropically at the structural level and require complex manufacturing and processing methods. Capturing this complex behavior requires detailed numerical simulations, including the modeling of microstructural features like undulations, voids, and fiber alignment. In this paper, multiple repeating unit cells (RUCs), representing filament wound composites, are developed (via a script provided in the Appendix) and analyzed. The refinement of these RUCs is varied, and the analyses are performed using both the Abaqus finite element software and the NASA Multiscale Analysis Tool (NASMAT). A study is undertaken to compare the predicted effective elastic properties of the wound RUC to a laminate representation of the wound RUC, which neglects the undulations. Additionally, two different sets of periodic boundary conditions (PBCs) have been examined. One approximates the real boundary conditions using a standard approach and the other represents the PBCs exactly through the use of an offset. Lastly, a comparison of the local elastic stress fields is made among the models and approaches. Since wound structures are often approximated as laminated structures, it is important to understand the degree to which this assumption is valid, namely by first comparing the elastic constants and local elastic fields. This will provide, on the one hand, information concerning the bulk mechanical behavior and, on the other hand, insights concerning local load distributions and likely damage initiation sites.

Composites↗

High modulus filament wound vessels for cryogenic containers in spacecraft.

Compared to metallic vessels, filament-wound vessels for containment of cryogens and high pressure gases offer high potential weight savings for NASA spacecraft applications. Since carbon fiber/epoxy resin composites exhibit high strength-to-density ratios, high-cycle fatigue life, and excellent strain compatibility with internal metallic liners, filament-wound carbon fiber/epoxy resin composites were evaluated for application to cryogenic internal pressure vessels. Compared to room temperature values, the cryogenic strengths of the composites were reduced by about 15% at -423 F (with the exception of one composite) while moduli increased as much as 25%. Filament-wound carbon fiber/epoxy resin vessel specimens, made by three fabricators, defined and solved problems in the processing of these friable high-modulus fibers into structurally efficient vessel specimens.

Simon, R. A.↗

A thermal analysis of a spirally wound battery using a simple mathematical model

A two-dimensional thermal model for spirally wound batteries has been developed. The governing equation of the model is the energy balance. Convective and insulated boundary conditions are used, and the equations are solved using a finite element code called TOPAZ2D. The finite element mesh is generated using a preprocessor to TOPAZ2D called MAZE. The model is used to estimate temperature profiles within a spirally wound D-size cell. The model is applied to the lithium/thionyl chloride cell because of the thermal management problems that this cell exhibits. Simplified one-dimensional models are presented that can be used to predict best and worst temperature profiles. The two-dimensional model is used to predict the regions of maximum temperature within the spirally wound cell. Normal discharge as well as thermal runaway conditions are investigated.

Evans, T. I.↗

Comparison of hand laid-up tape and filament wound composite cylinders and panels with and without impact damage

Experimentally determined axial compressive failure loads, strains and failure modes of composite flat panels and cylinders are presented. A comparison of two types of filament wound flat graphite-epoxy panels indicates that the winding pattern can influence structural response. A comparison of hand laid-up tape and filament wound composite cylinders indicates that fabrication method may not significantly influence the failure mode or average failure strain of thick-walled (radius-to-thickness ratio less than 15) graphite-epoxy cylinders. The interaction of manufacturing-induced features (fiber cross-overs) and low-speed impact damage for graphite-epoxy specimens is also presented. Filament would flat panels with many fiber cross-overs exhibited lower failure strains than filament wound panels without fiber cross-overs for all impact speeds examined. Graphite-thermoplastic cylinders exhibited a significantly different failure mode from the graphite-epoxy cylinders.

Jegley, Dawn C.↗

Mechanical load induces sarcoplasmic wounding and FGF release in differentiated human skeletal muscle cultures

The transduction mechanism (or mechanisms) responsible for converting a mechanical load into a skeletal muscle growth response are unclear. In this study we have used a mechanically active tissue culture model of differentiated human skeletal muscle cells to investigate the relationship between mechanical load, sarcolemma wounding, fibroblast growth factor release, and skeletal muscle cell growth. Using the Flexcell Strain Unit we demonstrate that as mechanical load increases, so too does the amount of sarcolemma wounding. A similar relationship was also observed between the level of mechanical load inflicted on the cells and the amount of bFGF (FGF2) released into the surrounding medium. In addition, we demonstrate that the muscle cell growth response induced by chronic mechanical loading in culture can be inhibited by the presence of an antibody capable of neutralizing the biological activity of FGF. This study provides direct evidence that mechanically induced, sarcolemma wound-mediated FGF release is an important autocrine mechanism for transducing the stimulus of mechanical load into a skeletal muscle growth response.

NASA Center JSC↗

Using Light to Treat Mucositis and Help Wounds Heal

A continuing program of research and development is focusing on the use of controlled illumination by light-emitting diodes (LEDs) to treat mucositis and to accelerate healing of wounds. The basic idea is to illuminate the affected area of a patient with light of an intensity, duration, and wavelength (or combination of wavelengths) chosen to produce a therapeutic effect while generating only a minimal amount of heat. This method of treatment was originally intended for treating the mucositis that is a common complication of chemotherapy and radiation therapy for cancer. It is now also under consideration as a means to accelerate the healing of wounds and possibly also to treat exposure to chemical and radioactive warfare agents. Radiation therapy and many chemotherapeutic drugs often damage the mucosal linings of the mouth and gastrointestinal tract, leading to mouth ulcers (oral mucositis), nausea, and diarrhea. Hyperbaric-oxygen therapy is currently the standard of care for ischemic, hypoxic, infected, and otherwise slowlyhealing problem wounds, including those of oral mucositis. Hyperbaric-oxygen therapy increases such cellular activities as collagen production and angiogenesis, leading to an increased rate of healing. Biostimulation by use of laser light has also been found to be effective in treating mucositis. For hyperbaricoxygen treatment, a patient must remain inside a hyperbaric chamber for an extended time. Laser treatment is limited by laser-wavelength capabilities and by narrowness of laser beams, and usually entails the generation of significant amounts of heat.

Ignatius, Robert W.↗

Excitation control of dual-wound machines for coupling mitigation

A dual-wound machine comprises a dual-wound generator supplying power to two separate powered zones. The generator comprises a wound rotor with a field winding and a stator with two sets of phase windings and a field control loop that controls the excitation voltage applied to the field winding and therefore the magnetic field produced by the rotor, in order to maintain a constant field flux in the generator and mitigate dynamic coupling between the two sets of phase windings when supplying power to unbalanced loads.

Rashkin, Lee Joshua↗

Wound Field and Hybrid Synchronous Machines for EV Traction with Brushless Capacitive Rotor Field Excitation (Final Report)

This project focused on the development of wound field synchronous machines (WFSMs) and hybrid excitation synchronous machines (HESMs) with brushless capacitive power transfer for the field excitation. The target application for the machines developed is the main traction motor in electric vehicles. The magnetization in these types of machines is provided by a field winding on the rotor which is excited with DC current. The magnetization level in the machine can be varied by changing the magnitude of the field current. The variable magnetization or field is one of the key features of WFSMs. WFSMs are commonly used as generators however they have several attractive features for automotive traction applications. 1) No use of permanent magnet: Rare earth permanent magnets are primarily mined and processed in China. They have been subject to large price and supply variations and their export may be restricted during times of geopolitical tension. 2) Easy field weakening: Wound field synchronous machines have complete control of their field excitation. With proper design, this type of machine can electromagnetically have an infinite constant power speed range. 3) High power factor: With proper choice of the field excitation, WFSMs may be operated with high or even unity power factor. This potentially allows for the inverter connected to the stator winding to be downsized. In comparison induction machines and interior permanent magnet synchronous machines must supply reactive power to the stator increasing the kVA rating and cost of the inverter. 4) Reduced iron losses at high speed: By reducing the field excitation, the iron loss in the stator can be reduced. This is in comparison to interior permanent magnet synchronous machines which must use stator current to buck or reduce the flux produced by the permanent magnets. Generally, WFSMs have their highest efficiency at high speed. 5) Torque output at high temperatures: The magnetization provided by the field winding only depends on the field current and not on the field winding temperature. This is in contrast to permanent magnet machines where the permanent magnet flux decreases as the magnet temperature increases. Historically a number of approaches have been developed to provide DC current to the rotating field winding in WFSM’s including brushes and slip rings, low frequency brushless exciters, and high frequency rotary transformers and rectifiers. In this project, a different approach was used: brushless capacitive power transfer. Brushless capacitive power transfer uses two sets of rotating capacitors or electrodes in which an AC electric field is established by a high frequency inverter. A displacement current can flow through the airgap in the rotating capacitors which is rectified on the rotor using a diode bridge. The potential advantage of capacitive power transfer is that there is no need for heavy iron to guide magnetic flux. The electric flux lines terminate on the charges on the rotary capacitor surfaces. This should also limit the electric field outside the rotary capacitor airgaps. The main challenge with capacitive power transfer is that the capacitance and surface area of the rotating capacitors is small. Because capacitive power transfer systems are essentially a dual of a magnetic system, an Ampere per Hertz relationship is characteristic versus a Volts per Hertz relationship. A very high frequency power inverter must be used to provide sufficient excitation to the field winding. The concept of using capacitive power transfer to excite a high performance WFSM was initially developed in a previous U.S.A. Dept. of Energy project, DE-EE0006829. This project focused on increasing the power density of the WFSMs and reducing the cost and manufacturing complexity of the capacitive power transfer system. This project has demonstrated that WFSMs with brushless capacitive field power transfer can provide a high-power density and low-cost automotive powertrain technology.

33 ADVANCED PROPULSION SYSTEMS↗

Ribbon Wrinkling Origin and Its Effect on Tape-Wound Core Shape

Improved understanding of advanced manufacturing techniques is needed to fabricate next- generation soft magnetic tape-wound cores. These utilize metal amorphous nano-composites (MANCs) in the form of long thin ribbons. MANCs exhibit attractive soft magnetic properties for use in high frequency and high power density magnetic components. Of particular interest here, the permeability and hysteresis of MANC ribbons can be tuned in a strain annealing process. An unexpected consequence is that wider ribbons develop longitudinal wrinkle patterns. This can substantially reduce the tape-wound core stacking factor. However, when winding a wrinkled ribbon into a toroidal core, the wrinkles can completely flatten, or crinkle. By this phenomenon, the stacking factor can be recovered. To understand the crinkling effect we have developed analytical and finite element analysis (FEA) models. Experiments with known boundary conditions demonstrate the transition from wrinkled to crinkled versus winding curvature. The models utilize an elastic modulus measured via ribbon tensile testing and a ribbon thickness value measurement made by profilometry. The analytical model provides insight into the crinkling effect but cannot explain the length of the transition region from wrinkling to crinkling. With FEA, we successfully predict the transition region and depending on wrinkling amplitude can determine when a ribbon will wind into a useable core. Such mechanics-based insight provides critical feedback for allowable processing parameters in the strain annealing process.

20 FOSSIL-FUELED POWER PLANTS↗

Characterization of a Human Platelet Lysate-Loaded Keratin Hydrogel for Wound Healing Applications In Vitro

One of the promising approaches to facilitate healing and regenerative capacity includes the application of growth-factor-loaded biomaterials. Human platelet lysate (hPL) derived from platelet-rich plasma through a freeze-thaw process has been used as a growth factor rich therapeutic in many regenerative applications. To provide sustained local delivery of the hPL-derived growth factors such as epidermal growth factor (EGF), the hPL can be loaded into biomaterials that do not degrade rapidly in vivo. Keratin (KSO), a strong filamentous protein found in human hair, when formulated as a hydrogel, is shown to sustain the release of drugs and promote wound healing. In the current study, we created a KSO biomaterial that spontaneously forms a hydrogel when rehydrated with hPL that is capable of controlled and sustained release of pro-regenerative molecules. Our study demonstrates that the release of hPL is controlled by changing the KSO hydrogel and hPL-loading concentrations, with hPL loading concentrations having a greater effect in changing release profiles. In addition, the 15% KSO concentration proved to form a stable hydrogel, and supported cell proliferation over 3 days without cytotoxic effects in vitro. The hPL-loaded keratin hydrogels show promise in potential applications for wound healing with the sustained release of pro-regenerative growth factors with easy tailoring of hydrogel properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filament-wound, fiberglass cryogenic tank supports

The design, fabrication, and testing of filament-wound, fiberglass cryogenic tank supports for a LH2 tank, a LF2/FLOX tank and a CH4 tank. These supports consist of filament-wound fiberglass tubes with titanium end fittings. These units were satisfactorily tested at cryogenic temperatures, thereby offering a design that can be reliably and economically produced in large or small quantities. The basic design concept is applicable to any situation where strong, lightweight axial load members are desired.

Carter, J. S.↗

High performance filament wound composites for pressure vessel applications.

A new high modulus fiber was evaluated as a reinforcement for filament wound pressure vessels. Based on preliminary data it offers significant specific strength and modulus improvements over an S-glass reinforcement. Winding parameters and design data were established for the fiber with two different epoxy resin systems. NOL composite rings were evaluated for tensile strength, modulus and interlaminar shear strength at +70 F, -320 F and -423 F. Results showed that the fiber reinforced composite exhibited a specific strength of 4,100,000 inches and a specific modulus of 290,000,000 inches compared to 3,260,000 inches and 110,000,000 inches respectively for S-glass. Utilizing this data to design small filament wound pressure vessels, a performance factor of 806,000 inches was obtained experimentally with PRD 49-1 fiber compared to values of 632,000 inches and 501,000 inches for S-glass and high modulus graphite vessels, respectively.

Hoggatt, J. T.↗

Graphite filament wound pressure vessels

Filament wound NOL rings, 4-inch and 8-inch diameter closed-end vessels involving three epoxy resin systems and three graphite fibers were tested to develop property data and fabrication technology for filament wound graphite/epoxy pressure vessels. Vessels were subjected to single-cycle burst tests at room temperature. Manufacturing parameters were established for tooling, winding, and curing that resulted in the development of a pressure/vessel performance factor (pressure x volume/weight) or more than 900,000 in. for an oblate spheroid specimen.

Feldman, A.↗

Filament-wound composite vessels material technology

Programs are reviewed that were conducted to establish a technology base for applying advanced fibers or resins to high performance filament-wound pressure vessels for containment of cryogens and high pressure gases. Materials evaluated included boron, graphite, PRD 49-1 and 3/epoxy and S-glass/polyimide composites. Closed-end cylindrical, and oblate spheroid-shaped vessels were fabricated in 4- and 8-inch diameter sizes. Vessels were subjected to single-cycle burst, low-cycle fatigue, and sustained loading tests over a -423 F to room temperature range for epoxy composites and a -423 to 500 F temperature range for the polyimide composites. Vessels tested at cryogenic and/or 500 F had thin (3 to 20 mils) metallic liners whereas vessels tested at room temperature had elastomeric liners. Correlations between acoustic emissions and burst and cyclic properties of PRD 49-1 filament-wound vessels are discussed.

Lark, R. F.↗