Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIPP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reevaluation of Actinide(IV)-Humic Complexation in the WIPP Performance Assessment - 16547

The legacy humic colloid model for tetravalent actinides (Th(IV), U(IV), Np(IV), and Pu(IV)) in the performance assessment (PA) of the Waste Isolation Pilot Plant (WIPP) is highly conservative. The model structure is feasible, but substantial reductions are needed for two constants, PHUMSIM and PHUMCIM. These constants are proportionality constants representing the equilibrium aqueous concentration ratio of humic-bound An(IV) to non-colloidal An(IV) for the Salado and Castile formations. In the WIPP PA model, both constants are set at 6.3 based on observed colloidal partitioning of Th(IV) in seawater. This value greatly enhances the mobile An(IV) concentration in the WIPP PA. Actual humic partitioning of An(IV) in WIPP brines is expected to be significantly lower than in seawater because the pH of WIPP brines (∼9) is higher, concentrations of competing cations (e.g., Mg{sup 2+}) are higher, and concentrations of aqueous humic substances may be lower. In this work, the results of recent studies of Th(IV)-humic and Ca{sup 2+}-humic complexation are used to simulate competitive humic complexation under WIPP conditions. The PHUMSIM and PHUMCIM values calculated for these simulations are in the range of 0.0013-0.0016 and 0.0047-0.0056, respectively. These values reduce humic-bound An(IV) to less than 1% of aqueous non-colloidal concentrations and would reduce mobile An(IV) concentrations in the WIPP PA by as much as 85%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternate Packaging Options for Remote-Handled Transuranic Waste Disposal at WIPP - 19093

Sandia National Laboratories/New Mexico (Sandia) began a remote-handled (RH) transuranic (TRU) repackaging campaign two weeks before the Waste Isolation Pilot Plant (WIPP) shutdown in February 2014. Since a contract with Nuclear Waste Partnerships (NWP), the WIPP Management and Operation (M and O) contractor, was already in place for certified visual examination (VE) and dose-to-curie (DTC) support, repackaging continued and was completed in October 2015. Twenty-five 55-gallon drums of RH TRU waste were packaged, awaiting certification and shipment to WIPP. However, in February 2017 at the National TRU Program (NTP) Corporate Board meeting, Sandia learned that RH TRU waste normally transported in removable lid canisters (RLCs) and 72-B casks was not being accepted for disposal when WIPP re-opened after the shutdown. One option, shielded container assemblies (SCAs), was available and approved for RH TRU waste disposal at the WIPP. Sandia made the decision to pursue the use of SCAs. The use of SCAs allow RH TRU waste to be shipped as contact-handled (CH) in HalfPACTs, emplaced on the floor of the WIPP instead of in boreholes in the walls, if the dose rate is less than 200 millirem/hour on contact. The RH TRU waste remains on the WIPP inventory as RH. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expanded Use of ISOCS Characterization Techniques for WIPP Certification at the Idaho Clean-up Project - 19623

The Advanced Mixed Waste Treatment Project (AMWTP) has been retrieving, treating, characterizing, and shipping legacy Transuranic (TRU) waste for disposal since 2003 as part of the overall Idaho Cleanup Project (ICP) in support of the US Department of Energy. As the ICP has progressed, over 700 containers have been identified that cannot be successfully assayed using the current suite of non-destructive assay (NDA) instruments. To meet this challenge, Fluor Idaho, LLC, and Mirion Technologies (formerly Canberra Industries) have teamed to deploy the In-Situ Object Counting System (ISOCS) to supplement the current NDA capabilities. ISOCS has long been used in various radioactive waste management applications, but never has the ISOCS ability to perform intrinsic efficiency modeling of discrete waste containers been employed to characterize and certify TRU waste for disposal at the Waste Isolation Pilot Plant (WIPP), near Carlsbad, New Mexico. Since the primary disposal facility for this waste is the WIPP, the characterization processes for determining the quantity of radioactive material entrained in the waste are subject to WIPP Waste Acceptance Criteria (WAC) quality requirements and associated performance criteria. Until now, the Carlsbad Field Office (CBFO) WIPP-certified NDA equipment has utilized pre-defined efficiency calibrations for fixed geometries. However, due to the radioactive material content, activity levels, waste stream matrix, and/or the geometries of various size drums, boxes and other-odd-shaped containers or container integrity issues, it may not be suitable to characterize these containers with any of the existing WIPP-certified NDA equipment located at the AMWTP. Therefore, advanced technologies are needed to complete characterization of these problematic waste containers. The July 5, 2016 release of the WIPP WAC, DOE/WIPP-02-3122, Revision 8.0, Appendix A, 'Radioassay Requirements for Transuranic Waste,' was expanded to include several newer concepts such as American Society for Testing and Materials (ASTM) approved methods for efficiency-based calibrations and the use of mathematical computer modeling techniques for calibration. This change prompted AMWTP to pursue obtaining WIPP certification authority for expanded ISOCS techniques to deal with the remaining challenging waste containers and the development and implementation of Mirion's Figures of Merit (FOM) evaluations. These vital FOM evaluations enhance the ISOCS's modeling capabilities by optimizing the dynamic efficiency calibration for each object and reducing the assay's Total Measurement Uncertainty (TMU) budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WASTE ISOLATION PILOT PLANT (WIPP): THE NATIONS' SOLUTION TO NUCLEAR WASTE STORAGE AND DISPOSAL ISSUES

In the southeastern portion of my home state of New Mexico lies the Chihuahauan desert, where a transuranic (TRU), underground disposal site known as the Waste Isolation Pilot Plant (WIPP) occupies 16 square miles. Full operation status began in March 1999, the year I graduated from Los Alamos High School, in Los Alamos, NM, the birthplace of the atomic bomb and one of the nation’s main TRU waste generator sites. During the time of its development and until recently, I did not have a full grasp on the role Los Alamos was playing in regards to WIPP. WIPP is used to store and dispose of TRU waste that has been generated since the 1940s because of nuclear weapons research and testing operations that have occurred in Los Alamos, NM and at other sites throughout the United States (U.S.). TRU waste consists of items that are contaminated with artificial, man-made radioactive elements that have atomic numbers greater than uranium, or are trans-uranic, on the periodic table of elements and it has longevity characteristics that may be hazardous to human health and the environment. Therefore, WIPP has underground rooms that have been carved out of 2,000 square foot thick salt formations approximately 2,150 feet underground so that the TRU waste can be isolated and disposed of. WIPP has operated safely and successfully until this year, when two unrelated events occurred in February 2014. With these events, the safety precautions and measures that have been operating at WIPP for the last 15 years are being revised and improved to ensure that other such events do not occur again.

07 ISOTOPE AND RADIATION SOURCES↗

There Are Safe Limits for Radioactivity - Does WIPP Need to Filter its Exhaust Air? - 17165

Pilot Plant (WIPP) underground repository resulted in the release of americium and plutonium (mostly {sup 241}Am) into the environment and contaminated portions of the repository, primarily along the ventilation path from the location of the incident. The WIPP uses a ventilation system to ensure that underground air is circulated through the repository and to ensure that air quality conditions are safe for the workers. Since the air in the repository exits to the surface through an exhaust shaft, this shaft is the sole potential pathway for airborne radioactivity release from the repository. During normal operations before the 2014 incident, exhaust air was released to the environment unfiltered, with an automatic switch to filtration when airborne radioactivity was detected immediately down-stream from the active waste disposal operation. However, since the radiation release event, the WIPP ventilation system has been, and will likely remain in what is called 'filtration mode,' (i.e., exhaust air is routed through a HEPA filter system). Redirection of the ventilation system through the HEPA (High Efficiency Particulate Air) filter system was necessary at the peak of the radiation release event to protect aboveground workers at the site and the public in the surrounding areas; however, it has hampered recovery efforts and has exacerbated the inherent safety issues of working underground. As a component of the Carlsbad Environmental Monitoring and Research Center's (CEMRC) WIPP environmental monitoring program, airborne radioactivity samples are collected daily in the exhaust shaft ventilation air as it reaches the surface, and before entering the HEPA filters. Since June 2014, airborne radiation levels entering the HEPA filters have averaged about 1% of a derived air concentration (DAC) for {sup 241}Am. An airborne radioactivity level of one DAC is equivalent to a potential worker internal dose exposure of 50 mSv per work year, if a worker were continuously exposed for a full work year (2000 hours). During Project Reach and throughout decontamination campaigns conducted in Panel 7 for several months in 2015, these unfiltered levels rose to 3-5% of a DAC, with a one week spike reaching almost one DAC in June 2015, during decontamination of the most heavily contaminated exhaust drift in Panel 7. Since that period, the unfiltered levels have never exceeded 2% of a DAC. Going forward, the question is, should WIPP resume unfiltered discharge of its underground ventilation air? Evaluation of more than two years of underground ventilation sampling data indicates that residual radioactivity levels in the underground no longer warrant HEPA filtration in order to meet either worker or environmental protection criteria. In terms of radiological risk at or in the vicinity of the WIPP site, the increased risk from resuming unfiltered ventilation is exceedingly small and would not result in a hypothetical dose to a member of the public in excess of the 100 micro Sv per year limit for periodic confirmatory sampling as required for operating repositories by the Environmental Protection Agency (40 CFR 191). In addition, the requirement for respiratory protection for workers underground exposed to 1-2% of a DAC is questionable, given the added industrial safety risk of heavy equipment operation while wearing respirators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of three-dimensional models for WIPP performance assessment using PFLOTRAN - 15073

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been developed by the U.S. Department of Energy (DOE) for the deep geologic disposal of transuranic (TRU) waste. WIPP performance assessment (PA) calculations estimate the probability and consequence of potential radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. To date, WIPP PA calculations have employed multiple 2D numerical models requiring simplification of the mesh and processes. Introducing 3D numerical models within WIPP PA enables increasingly realistic representations of the WIPP subsurface domain and improved flexibility for incorporating relevant features. Furthermore, the increased computing capacity afforded by modern hardware architectures enables this 3D modeling. Modeling in 3D will be more flexible because less homogenization is required and better accuracy of the results can be obtained by making fewer assumptions and/or simplifications. The use of PFLOTRAN, a state-of-art massively parallel subsurface flow and reactive transport code, will enable this 3D modeling, and eliminate the need for multiple related, but decoupled 2D models. However, there are capabilities that PFLOTRAN must be demonstrated in order to fulfill requirements for WIPP PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Certification of the Retrieval Box Assay System at the Advanced Mixed Waste Treatment Plant, Idaho - 16241

The Retrieval Box Assay System (RBAS) at the Advanced Mixed Waste Treatment Plant (AMWTP) is an Imaging Passive Active Neutron system supplemented with a High Purity Germanium (HPGe) gamma system for the quantification of Pu-239 Fissile Gram Equivalent (FGE) and transuranic (TRU) alpha activity of waste containers of various sizes up to 249 cm x 149 cm x 198 cm (Length x Width x Height). The system was originally calibrated in 2002 (with a range of surrogate matrices and radioactive sources in a 213 cm x 122 cm x 122 cm FRP box) and has been operational for over a decade. As of August 2015, the RBAS has measured approximately 18,000 boxes (50,000 m3 of waste) which has subsequently been fed into the facility's treatment process. Its success, and the wide envelope of waste that it can characterize, has led AMWTP to extend the RBAS mission to include WIPP certification. As part of this new project, the instrument must be capable of meeting WIPP's Waste Acceptance Criteria (WAC) which include reporting activities and masses of the 10 WIPP-tracked radionuclides. The system will be required to assay sludge and debris waste streams, shredded waste and large metal items. The container size includes Standard Waste Box (SWBs), Fiberglass Reinforced Plywood (FRPs) and large Shredder Boxes. Sludge matrices will be loaded into 210-liter (55-gallon) drums and placed inside an SWB. After assay, boxes will be over-packed into SLB-II's for shipment to WIPP. The target waste streams will contain mixtures of Weapons Grade plutonium, Heat Source plutonium (high in Pu-238 content) and Mixed Oxide (MOX). The activity of the waste is expected to encompass a wide dynamic range of activity from low-level waste (LLW) to TRU with up to several hundred grams of plutonium. Some packages will have high gamma activity associated with fission and activation products such as Cs-137 and Co-60. The existing RBAS hardware (detectors, electronics, assay chamber etc.) was retained for this project. Two lead filters were provided and installed on the existing filter wheels to attenuate the gamma ray flux from the highest activity boxes to avoid overload of the HPGe detectors. The new software suite includes PC-FRAM (Version 5), which is used for the isotopic analysis of the gamma spectra. Integration of FRAM and neutron results is performed using a software package known as RBAS WIPP Analysis Reporting Software (RWARS). This package also performs matrix dependent background adjustments. Other upgrades provided include automated tests that identify when assay parameters fall outside a predetermined range and a new Quality Checking (QC) application. Minimum Detectable Activity (MDA) values were determined for the active and passive neutron modes as a function of measured matrix correction indices. The resulting Minimum Detectable Concentration (MDC) has been demonstrated to be less than 3700 Bq/g alpha activity (100 nCi/g). Modifications were performed to update the system TMU parameters to accommodate assay of non-standard size boxes and a wider range of matrix materials. A series of calibration confirmation, measurements were performed on site in 2014 using a representative range of surrogate boxes and radioactive sources including Pu. The WIPP WAC performance criteria were successfully demonstrated up to 157 g Pu and the system passed its first Performance Demonstration Program (PDP) cycle in the Spring of 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Evaluation Criteria to Meet the WIPP Waste Acceptance Criteria - 18655

The Waste Isolation Pilot Plant (WIPP) is a deep geologic repository for the disposal of Transuranic (TRU) waste and the only such disposal facility of its kind. TRU waste is radioactive mixed waste generated by the U. S. Department of Energy in support of National Defense. In 2014, the WIPP facility was shut down when two separate accidents occurred in the repository. The two accidents were a fire on a large underground haul truck that prompted evacuation and filled the mine with smoke and soot, and a radiation release that contaminated the exhaust ventilation and disposal areas of the mine. DOE performed two accident investigations in 2014 that resulted in many corrective actions. Some of the corrective actions resulted in significant changes in the WIPP Waste Acceptance Criteria (WAC) and are required to be applied to all TRU waste upon the resumption of shipments to WIPP. WIPP re-opened and began taking shipments again in 2017 and a large backlog of over 25,000 TRU waste containers that were certified prior to the new WAC have been undergoing re-evaluation since the re-opening. This paper will focus on the new WAC criteria that TRU waste must meet above-and-beyond previous WAC criteria and the implementation of new processes for approval. The primary area for these changes is in the area of waste characterization using Acceptable Knowledge (AK) and new detailed analyses required for chemical compatibility. The accident investigation revealed that the radiation release was due to a thermal runaway and bursting of the waste container due to inadvertent mixtures of nitrates and combustibles resulting in ignitable waste forms. In other words, the TRU waste container had incompatible contents that went undiscovered and created a hazard characteristic that was prohibited at WIPP. Through detailed chemical compatibility evaluations and new oversight, the DOE should be able to prevent a similar accident (see Figure 1). The new chemical compatibility evaluations and evaluations of oxidizing chemicals combined with combustibles are complex and detailed. Chemical compatibility is not a new requirement, but a much more detailed evaluation is a new requirement. And, obtaining historical information about the generation of the final waste form for legacy packaged waste can be very challenging. Specifically, determining possible amounts of chemicals in the waste can be extremely challenging. This paper does not explore in depth, the details of oxidizing chemicals. Other papers presented will discuss oxidizing chemicals. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium Oxidation State Distribution in the Presence of WIPP-Relevant Organics and Iron Corrosion Products

The oxidation state and solubility of plutonium (Pu) in high ionic strength synthetic WIPP (Waste Isolation Pilot Plant) brines as a function of pC H+ in the presence and absence of WIPP-relevant organic ligands (EDTA [Ethylenediaminetetraacetic acid], oxalate, citrate, acetate) and iron corrosion products (magnetite and metallic iron) at 𝑇 = 23 ± 2 ∘C was thoroughly studied by long-term batch solubility experiments (between approximately 800-1,100 days) from an undersaturation approach. The oxidation state of Pu in the WIPP environment has been a topic of interest since the initial Compliance Certification Application (CCA). This study aims to investigate the solubility of Pu under the expected WIPP conditions and to determine the oxidation state of the solid phase that will control the solubility. One of the most important results of this study is that the Pu oxidation state was analyzed both from the surface area of the corrosion products and in the precipitated solid. The analysis of the Pu oxidation state on the surface of the iron mineral from the ongoing undersaturated experiments is more relevant to the performance assessment of nuclear waste disposal than short term batch (plutonium-iron phase) experiments. The X-ray Absorption Near-Edge Spectroscopy (XANES) analysis showed that Pu oxidation state is different on the metal surface and in the precipitated solid. Pu(III) is the dominant oxidation state in the metallic iron (Fe 0 ) system in the presence and absence of organics. Pu(IV) is the dominant oxidation state in the magnetite system in the presence and absence of organics. Also, organics stabilize Pu(IV) in the magnetite system. Analysis of Pu in the precipitated solid by Extended X-ray Absorption Fine Structure (EXAFS) analysis showed that Pu formed an inner-sphere complex with iron with minor amounts of PuO 2 present. X-ray diffraction (XRD) results indicate that metallic iron and magnetite did not oxidize in three years in the alkaline and high ionic strength system. Under these conditions (8 < pC H+ < 10 at T = (22 ± 2) °C under nitrogen atmosphere, the solubility of Pu changes by up to three orders of magnitude (10 -5 and 10 -8 M). The spread in solubility is highest at pC H+ = 9. Pu(III) and Pu(IV) showed different solubility behavior in the synthetic WIPP brine. A summary of the data collected in this report will be submitted to Sandia National Laboratories as part of a parameter update report which will outline the changes to the OXSTAT parameter for the 2026 Compliance Recertification Application (CRA-2026). The experiments performed were done according to the U.S. Department of Energy (DOE) approved Test Plan entitled “Effects of Radiolysis, Organic Complexation, and Redox Conditions on the Speciation and Oxidation State Distribution of Pu(III/IV)” (LCO-ACP-25). All data reported were obtained under the Los Alamos National Laboratory-Carlsbad Office (LANL-CO) Quality Assurance Program, which is compliant with the DOE Carlsbad Field Office, Quality Assurance Program Document (CBFO/QAPD).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance assessment modernization at WIPP - 15077

To aid in WIPP PA calculations, the US DOE has undertaken a broad modernization effort that includes: 1) updating the hardware and operating system used; 2) moving the current PA (performance assessment) codes to the new system; and 3) adding a database to store results essential for the analysis of assessments; 4) integrating run-control scripts with a web site to facilitate monitoring of performance assessment calculations; and 5) adding new capabilities via implementation of the PFLOTRAN code to replace multiple codes currently in use. The majority of codes were migrated from an Open VMS/Alpha processor system to a Unix/Intel processor system. Most codes were upgraded to use the dynamic allocation features of Fortran 95 and double precision variables. A few codes were migrated from Linux/Intel systems to the Unix/Intel systems and these code required nearly no changes to the source code. All of the migrated codes were re-qualified under Sandia's WIPP QA program. The implementation of some of the conceptual models using PFLOTRAN is being driven by the expectation that changes in the configuration of the repository will require a 3-dimensional representation of the mined areas. Symmetry in the current configuration of the repository made a 2-D representation adequate. PFLOTRAN is an open-source, state-of-the-art massively parallel subsurface flow and reactive transport code. A version of this code is being developed specifically for WIPP PA in order to maintain the capabilities of the current flow and transport codes, as well as add the capabilities of a parallel code that will treat additional processes, including: 1) miscible multi-phase flow; and 2) heat transfer. PFLOTRAN will replace the two codes (i.e. BRAGFLO and NUTS) currently used for flow and transport calculations, simplifying the PA code structure and speeding up calculations by simultaneously solving for flow and transport with a single code. To ensure that PFLOTRAN reproduces the results of the current code suite, existing test cases have been used for verification purposes. Additional test cases have been developed to establish the new capabilities for WIPP PA. The result of the modernization effort will be a state-of-the-art subsurface flow and transport capability that will serve WIPP PA into the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The role of independent monitoring in maintaining community support through a radiological incident - a WIPP case study - 15107

The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy (DOE) waste repository for the permanent disposal of defense transuranic (TRU) wastes. The repository is mined in the Salado Formation, a bedded salt formation of the Permian era, approximately 655 m (2150 ft.) below land surface. Located near Carlsbad, New Mexico, the WIPP facility is the world's first deep geological disposal facility licensed to accept TRU waste. Environmental monitoring is a key component in the development and operation of any nuclear facility. Well after the WIPP facility had been sited and constructed, but before repository operations began, DOE and local community leaders recognized the value of having an independent environmental monitoring program in addition to the self-monitoring program required by regulation. An independent monitoring organization, the Carlsbad Environmental Monitoring and Research Center (CEMRC) was created by New Mexico State University at its Carlsbad campus. After almost fifteen years of successful waste disposal operations, the first airborne radiation was accidentally released from the WIPP and detected beyond the site boundary on February 14, 2014. The accident released moderate levels of radioactivity into the underground air. A small but measurable amount of radioactivity also escaped to the surface and was detected beyond the site's inner boundary. The results were reported to the public as they were obtained and verified. Releases were low and localized, and no radiation-related health effects among local workers or the public would be expected. CEMRC's independence and its extensive monitoring program played a crucial role in timely informing the local populations on the levels and types of radiation released from the WIPP. CEMRC also helped eliminate unnecessary concern surrounding fear of radiation by engaging local populations through news releases and presentations at 'town hall' meetings sponsored by the Mayor's Office and the Department of Energy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of an additional exhaust shaft on WIPP performance - 15170

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of transuranic (TRU) waste. WIPP performance assessment (PA) demonstrates repository performance from facility closure to 10,000 years after closure. The recent radiological release event at the WIPP site has temporarily halted waste emplacement activities at the facility. A modified ventilation system is envisioned that will provide sufficient airflow necessary for the resumption of full-rate disposal operations in the future. A primary component of the modified ventilation system is an additional exhaust shaft in the north end of the repository. There are four shafts currently in the repository north end, namely a salt handling shaft, an exhaust shaft, a waste shaft, and an air intake shaft. These shafts are combined into a single composite shaft in WIPP PA that captures the combined impacts of all of them. The proposed additional exhaust shaft is combined with the four existing shafts in the repository model to determine its impacts on long-term repository performance. Moreover, mined volume in the repository north end is modified in the repository representation so as to include additional drifts created to access the new shaft. Computed gas and brine flow behaviors corresponding to the repository with the additional exhaust shaft are compared to those obtained in the PA executed for the 2014 Compliance Re-certification Application (the CRA-2014 PA). Results show that the repository with an additional exhaust shaft and drifts yields brine and gas flow behaviors similar to the current repository configuration. It is concluded that WIPP continues to satisfy regulatory compliance limits with the addition of an exhaust shaft and its access drifts, with compliance curves like those found in the CRA-2014 PA for total normalized releases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP - February 2014 operational events and the compliance re-certification application (CRA) 2014 - 15293

On Wednesday, February 5, 2014, an underground mine fire involving a salt haul truck occurred at the Waste Isolation Pilot Plant (WIPP). There were 86 workers in the mine when the fire occurred. All workers were evacuated. Nine days later, on Friday, February 14, 2014, there was an incident in the underground repository at WIPP which resulted in the release of americium and plutonium from one or more transuranic (TRU) waste containers into the environment. The release was detected by an underground continuous air monitor and then directed through high-efficiency particulate air (HEPA) filter banks located in the surface exhaust building. However, a measurable portion bypassed the HEPA filters via leakage through two ventilation system dampers and was discharged directly to the environment from an exhaust duct. No personnel were determined to have received external contamination; however, some individuals that were on site were identified through bioassay to have initially tested positive for low level amounts of internal contamination. Trace amounts of americium and plutonium were detected off-site.While significant to day-to-day operations, these events have no impact to the long-term performance of the repository. Because WIPP's re-certification is based solely on the post-closure performance of the repository (40 CFR 191, Subparts B and C), these recent events do not affect the long-term performance predictions or its technical and scientific basis. In this paper we will further explore the requirements for WIPP's re-certification, and the basis for our contention that the recent WIPP operational events do not impact long-term repository performance or have any implications on salt as a geologic disposal media, and that re-certification efforts should continue uninterrupted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovering New Type of Sources by Off-Site Source Recovery Project for WIPP Disposal - 16604

OSRP uses two types of eligible packaging configurations for Cm-244 and Cf-252 disposal to WIPP: an S-100 drum and a 12'' Pipe Overpack (POC) drum. Both types of packaging are WIPP accepted configurations for Contact Handled (CH) waste, which offer different advantages and disadvantages when used in the case of the two isotopes. The S-100 is a poly-shielded type A, 55 gallon drum, containing a 6'' diameter POC. The 12'' POC drum is a type A, 55 gallon drum without the internal poly-shield and with a pipe component of 12'' diameter. The S-100 drum presents the advantage of poly-shielding which is very important for neutron sources, such as the Cf-252, or Cm-244Be, at the expense of reduced internal volume. The 12'' POC drum presents a larger pipe component accommodating many more sources, like Cm-244 alpha emitters or shielded Cf-252, for which the CH dose rate is not an issue. All the sources prepared for disposal to WIPP are required to be special form, as defined in 49 CFR 173.403. When OSRP recovers normal form sources, these can be packaged in a field closable DOT certified Special Form Capsule (SFC) model II or model III, thus becoming special form. These capsules are then packaged in the type-A containers. The difference between the two types of packaging is that the 12'' POC can hold more sources, or a mix of sources and capsules at the expense of less shielding. This becomes important when the TRU content criteria of 100 nCi/g of TRU waste has to be met for the drums that are packaged for WIPP disposal. Measured neutron dose rates for Cm-244 packaged in S-100 agree reasonably well with calculated dose rates based on the models developed with MCNP. Future work will include validating the model for Cm-244 packaged in 12'' POC. A 1:1 ratio of neutron to gamma is expected for Cm-244Be dose rates packaged in S-100 drums. For Cf-252 packaged in S-100 and 12'' POC, the contribution of Cf-250 to the total emission neutron rate had to be taken into account due to the increasing role of Cf-250 as sources age. The uncertainty in the measurement of Cf-252 neutron dose rate for S-100 drum was quite high due to a high neutron background. A larger Cf- 252 source needs to be used for measurements in the future, in order to fully validate the model developed. A better agreement for measured versus calculated rate was obtained for a Cf-252 packaged in 12'' POC. For the WIPP disposal of these sources, OSRP will use the best packaging configuration for these isotopes in order to minimize the dose rate and maximize the TRU content. The S-100 packaging will be used for Cf-252 and Cm-244Be sources, when neutron dose reduction by the poly-shielding is important. Neutron dose rates will be estimated using the new MCNP correlations.

07 ISOTOPE AND RADIATION SOURCES↗

WIPP Space Faces TRU Waste Disposal Limits; The Volume Reducing Solution - 18365

Transuranic (TRU) waste packaging for removal from a glovebox has for many years involved the use of bags as the primary containment. In many cases, many hydrogenous layers of bags, yards of tape, and multiple filters are added to the waste stream in order to get the TRU waste into the final 55 gallon drum package to be shipped and buried at the Waste Isolation Pilot Plant (WIPP). The WIPP is currently limited to a total finite disposed volume of Contact Handled (CH) and Remote Handled (RH) TRU waste. As of early 2014 over half of the allotted WIPP volume had been filled with mainly CH-TRU waste. Based on current bag operation packaging methods used, the Department of Energy's (DOE) remaining CH and RH waste will not fit in the remaining limited WIPP space. Bag operations, can be performed safely by good operators following tedious repetitive processes and many Administrative Safety Controls. Since the bag is the only confinement layer between the contamination and the operator, contamination incidents can occur. Bag-out operations require close proximity to the waste to perform the process. With some waste streams, this close to waste proximity increases operator radiation dose. Central Research Laboratories (CRL), based in Red Wing Minnesota, who for many decades has developed proven engineered material transfer solutions based around their Rapid Transfer Port (RTP) technology, has worked with DOE sites to develop a TRU Waste Management Solution. The solution is a single filtered large Polyethylene (PE) or Stainless Steel (SST) Rapid Transfer Port container in a standard Department of Transportation (DOT) 7A, Type A drum, which allows for loading of TRU waste directly from the operational glovebox without the use of bags, sleeves or tapes to provide leak tight containment. All operator interventions to connect and disconnect a drum to and from the glovebox are achieved in an upright ergonomic position by one (1) operator in less than three (3) minutes. Minimal As Low As Reasonably Achievable (ALARA) levels are achieved during connect and disconnect of the drum, due to the engineered safety controls of the RTP. The CRL RTP solution allows glovebox or re-packaged TRU waste to be safely transferred to the final 55 Gallon drum container without additional bags or tape. The high diffusion coefficient filter on the CRL RTP 55G container and elimination of added hydrogenous packaging, improves the Decay Heat Limit (DHL) per drum for most TRU waste types compared with bagged drums, and in most cases allows more TRU waste to be loaded per drum. Inorganic TRU waste materials can be packaged directly into the CRL RTP SST drum container to the maximum DHL and Fissile Gram Equivalent (FGE) allowable for a drum. This paper will show how highly efficient TRAMPAC approved TRU waste packaging of CH and RH TRU waste can be accomplished in a safer, cost effective manner without adding any additional packaging materials to the waste stream, thus increasing the chance of placing all DOE's legacy and to be generated TRU waste in the remaining WIPP space. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 25: DOE Waste Isolation Pilot Plant (WIPP) Update 2020

This panel focused on the WIPP operational efficiencies and capital improvement progress in the year 2020. Because WIPP is a key component of the US DOE EM cleanup strategy, the progress on returning WIPP to full design capacity and throughput by 2021 is of importance. Panelists with presentations: Status of WIPP Capital Asset Projects (Stephen Smith); WIPP Update (Sean Dunagan); CBFO Update (Greg Sosson)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actinide (III/IV) - Silica Colloids in the WIPP

During the completeness process for the 2019 Compliance Recertification Application (CRA) for the Waste Isolation Pilot Plant (WIPP), the US Environmental Protection Agency (EPA) raised concerns about the possible presence of actinide-silica colloids in the WIPP. Several publications that studied the An(IV)- silica system indicated that these colloids could form under conditions similar to WIPP. Colloids are important for WIPP Performance Assessment (PA) as these are a mobile fraction of actinides that contribute to release. As the previously published papers did not explore the formation of actinide-silica colloids under the high ionic strength environment expected in WIPP, an experimental strategy to study these systems was developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neptunium (V) Solubility in the Presence and Absence of WIPP Relevant Ligands

CRA (Compliance Recertification Application)-2024 will update the oxidation state specific model used to calculate actinide solubility in the WIPP (Waste Isolation Pilot Plant). The pentavalent Np(V) ion is the most stable ion in solution within the An(V) series. This valence stability of Np(V) in aqueous solution makes Np a useful representative element for studying the aqueous complex chemistry of all An(V), but in the predicted WIPP scenario, this is the only TRU component that increases in the inventory with time as it is the main daughter product of 241 Am decay (alpha, n) so its relative importance increases throughout the 10,000-year performance period of the WIPP, it is only used to represent itself. This work is focused on confirming organic, borate and carbonate effects on solubility of Np(V) in WIPP simulated brines and 5 M NaCl and reassessing the predicted model speciation to strengthen the overall WIPP An(V) model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗