Application of Fe-doped biochar in Cr(VI) removal from washing wastewater and residual Cr(VI) immobilization in contaminated soil

High-content Cr(VI)-contaminated soils are challenging to remediate using a single remediation technique. This study combined soil washing and immobilization to remediate high-content (3440 mg kg -1 ) Cr(VI)-contaminated soil, which investigated the effects of operating time, temperature, and liquid-solid ratio (LSR) on the Cr(VI) removal efficiency of soil washing and evaluated the potential of Fe-doped biochar (FeBC) in soluble Cr(VI) removal from the washing wastewater and residual Cr(VI) immobilization in the washed soil. The Cr(VI) removal efficiency of soil washing increased with the operating time, temperature, and LSR, but still cannot remove Cr(VI) to achieve the safety content (<100 mg kg -1 ). FeBC showed satisfactory potential in both Cr(VI) removal and immobilization from wastewater and soil, in which the main mechanisms involve ion exchange, redox, and coprecipitation. These results demonstrate applying soil washing & immobilization to remediate high-content Cr(VI)-contaminated soil is a promising alternative method.

54 ENVIRONMENTAL SCIENCES↗

Characterization of the SRNL-Washed tank 51 sludge batch 9 qualification sample

Savannah River National Laboratory (SRNL) personnel have been requested to qualify the next sludge batch (Sludge Batch 9 – SB9) for processing at the Defense Waste Processing Facility (DWPF). To accomplish this task, Savannah River Remediation (SRR) sent SRNL a 3-L sample of Tank 51H slurry to be characterized, washed, and then used in a lab-scale demonstration of the DWPF flowsheet (after combining with Tank 40H sludge). SRNL has washed the Tank 51H sample per the Tank Farm washing strategy as of October 20, 2015. A part of the qualification process is extensive radionuclide and chemical characterization of the SRNL-washed Tank 51H slurry. This report documents the chemical characterization of the washed slurry; radiological characterization is in progress and will be documented in a separate report. The analytical results of this characterization are comparable to the Tank Farm projections. Therefore, it is recommended that SRNL use this washed slurry for the ongoing SB9 qualification activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of sanitizer application on Salmonella mitigation and microbiome shift on diced tomato during washing and storage

Here, this study examined the shift in Salmonella and indigenous microbiota on diced tomato after washing with three different sanitizers and during post-wash cold storage. Roma tomatoes were inoculated with a Salmonella cocktail (initial level ~ 5.6 CFU g –1 ), diced and washed along with uninoculated diced tomato in simulated flume wash water with sanitizers, including 10 mg L –1 free chlorine (FC10), 90 mg L –1 peracetic acid (PA90), PA90 in combination with a proprietary acidified surfactant blend (PS90), and unsanitized control (CK). Salmonella, total mesophilic aerobic bacteria (MAB), and yeast and mold (YM) populations on both inoculated and uninoculated samples were measured before and after washing, and during storage at 4 °C. 16S rRNA amplicon sequencing was also performed to determine the shift in bacterial microbiome. Washing with all tested sanitizers, especially PS90 (> 4 log Salmonella reduction), reduced Salmonella and MAB populations on inoculated diced tomatoes. Additionally, application of sanitizers mitigated Salmonella cross-contamination onto uninoculated samples. PS90 treatment inhibited the proliferation of most dominant bacteria on diced tomatoes during storage, including Erwiniaceae, Curtobacterium, Pantoea, Erwinia and Enterobacterales, which may benefit product quality and safety.

16S rRNA amplicon sequencing↗

Study of phase transformation and microstructure of alcohol washed titania nanoparticles for thermal stability

Nanostructured titania have been successfully synthesized by hydrolysis of alkoxide at calcination temperatures 500 °C, 600 °C and 700 °C. As the calcination temperature increases, alcohol washed samples show lesser rutile content as compared to water washed samples. Morphology and Particle sizes was determined by field emission scanning electron microscopy (FESEM), while thermogravimetric-differential scanning calorimetry (TG-DSC) was used to determine thermal stability. Alcohol washed samples undergo 30% weight loss whereas 16% in water washed samples was observed. The mean particle sizes were found to be increase from 37 nm to 100.9 nm and 35.3 nm to 55.2 nm for water and alcohol washed samples respectively. Hydrolysis of alkoxide was shown to be an effective means to prepare thermally stable titania by using alcohol washed samples as a precursor.

36 MATERIALS SCIENCE↗

Optimizing Vehicle Fleet and Assignment for Concentrating Solar Power Plant Heliostat Washing

Concentrating solar power central-receiver plants use thousands of sun-tracking mirrors, i.e., heliostats, to reflect sunlight to a central receiver, which collects and uses the heat to generate electricity. Over time, soiling reduces the reflectivity of the heliostats and, therefore, the efficiency of the system. Current industry practice sends vehicles to wash heliostats in an ad hoc fashion. We present a mixed-integer nonlinear program that determines wash vehicle fleet size, mix, and assignment of wash crews to heliostats to minimize the sum of (i) the revenues lost due to heliostat soiling, (ii) the costs of hiring wash crews and operating the vehicles, and (iii) the costs of purchasing wash vehicles. We establish conditions for convexity of the objective function, and then propose a decomposition method that enables near-optimal solutions to the wash vehicle fleet sizing and assignment problem on the order of a couple of minutes. Furthermore, these solutions yield hundreds of thousands of dollars in savings per year over current industry practices.

14 SOLAR ENERGY↗

Composition and Wash Solution Measurements for LAW Melter Sulfur Tolerance Study Glasses

In this report, the Savannah River National Laboratory (SRNL) provides chemical analysis for several simulated low-activity waste (LAW) glass compositions, as well as chemical analysis of the wash solutions resulting from the preparation of these glasses. The Pacific Northwest National Laboratory (PNNL) selected and fabricated these glasses as part of a study on sulfur retention in glasses previously evaluated. The resulting data will be used in the development of improved property/composition models for LAW glass production at Hanford. Chemical analyses were performed on a representative sample of each of the study glasses to allow for comparisons with the targeted compositions. Glass standards were intermittently measured to assess the performance of the analytical instruments over the course of these analyses. There were no issues with measurements of the glass standards. A review of the individual glass composition measurements identified no analytical issues of concern. Minor differences between the targeted and measured concentrations of some of the baseline glass components were noted, including some low values for Al 2 O 3 , CaO, Na 2 O, and ZrO 2 . Chemical analyses were also performed on a representative sample of each of the wash solutions resulting from the preparation of the sulfur saturated melt (SSM) versions of the study glasses. No issues were noted for the measurements of the solution standards. Several elements had measurable concentrations in the wash solutions, including B, Ca, Cl, Cr, K, Li, Na, P, S, and V. The measured concentrations of Na in the wash solutions were in the range of 200-1200 mg/L. This may be attributed to both the excess sodium sulfate added as part of the SSM preparation process, as well as to the lower measured concentrations of Na 2 O in some of the SSM versions of the study glasses. The measured concentrations of sulfate in the wash solutions were in the range of about 750-2250 mg/L. PNNL may wish to make further comparisons between the compositions of the glasses and the compositions of the wash solutions.

36 MATERIALS SCIENCE↗

Washing Study with SRS Tank 26 Samples FTF-26-19-12 and -13

A recent analysis of Tank 26, one of the feed tanks for the Defense Waste Processing Facility (DWPF) Sludge Batch 10 (SB10), determined a higher than anticipated sulfur concentration in the supernatant and a significant amount of insoluble sulfur, which could negatively impact the DWPF glass waste form. Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) perform a washing study with Tank 26 material to determine amount of sulfur removed during washing tests. SRNL decanted supernate from a sample of Tank 26 until it was at 12 wt% insoluble solids. Subsequently, SRNL performed washing experiments from the 8 M sodium initial concentration to targeted endpoints of 4 M, 2 M and 1 M sodium concentration (assuming no sodium dissolution). Results show that over 80% of the sulfur was removed and nearly all the sulfur was in the aqueous phase at the end of washing, demonstrating effective removal of sulfur during washing. Additional washing is likely to decrease the sulfur concentration further since most of the sulfur was in the aqueous phase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Wash-Aid, Treatment, and Emergency Reuse System (IWATERS) for Strontium Contaminations - 17390

The Integrated Wash-Aid, Treatment, and Emergency Reuse System (IWATERS) is being developed to mitigate the release of radioactivity to the urban environment by disseminating, collecting, and processing decontamination wash water. Previously, IWATERS was designed for the treatment of surfaces contaminated with radioactive cesium. Experiments were performed to investigate the expansion of IWATERS for strontium contamination. Bench-scale tests were performed to investigate various counter-ions and chelators to promote ion exchange of strontium from building surfaces. Desorption results for Cs, Sr, and Eu from concrete aggregate and concrete, brick, and asphalt coupons using low- and high-pressure flow with Ca{sup 2+} and Ba{sup 2+} rich wash water are reported along with those from non-porous surfaces such as glass and vinyl siding. Several sorbents were tested for their ability to specifically separate Sr{sup 2+} from these high ionic strength wash waters. Alkali metal and alkaline earth salts were found to be effective counter-ions for decontamination of Sr{sup 2+}, which may facilitate the use of common sorbents, even if their K{sub d} values are <100 mL/g. In practice, low K{sub d} values require the use of large quantities of sorbent. Computer simulations were run using the GoldSim Contaminant Fate Module software package to optimize the efficiency of IWATERS for strontium and account for the technical limitations of the sorbents. This modeling allows greater flexibility to design the wash water recycling system for various end-user specifications including options from rain barrel designs for treating runoff from roofs and facades to larger options like drainage basins for larger-scale wash down activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Penetration of Fission Products Ions into Complex Solids and the Effect of Ionic Wash Methods

During washing of radiologically impacted building surfaces, penetration of radionuclide ions into complex solids associated with these surfaces may occur. This study investigates the penetration of Cs-137, Sr-85, and Eu-152 solutions into numerous common building materials and radionuclide behavior when these materials were exposed to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for Cs-137 and Eu-152 and 50-80% for Sr-85. Water effectively removed all contaminants from hard nonporous surfaces. Finally, this paper illustrates that a wash penalty factor concept-defined as ratio of the depth at which 50% of the radioactivity is found in the washed sample divided by the depth at which 50% of radioactivity is found in the control-can serve as a way to quantify whether the wash method increases the depth at which contamination penetrates into the material and thus the material becomes more difficult to decontaminate.

building materials↗

Evaluation of a multifiltration water reclamation subsystem to reclaim domestic clothes wash water

An evaluation has been performed of a multifiltration water reclamation subsystem to determine its capability to recover water from domestic clothes wash water. A total of 32.89 kg (72.5 lb) of clothes were washed during eight wash cycles which used 1.4 lb of detergent, 145 gallons of hot water and 133.9 gallons of cold water. Water recovered at a weighted average process rate of 3.81 gallons per hour met the majority of the 23 requirements established for potable water by the U.S. Public Health Service. Average power consumed during this evaluation was approximately 71 watt-hours per gallon of water recovered. Filter replacement, which was required primarily for the control of micro-organisms in the recovered water averaged 4.86 filters per 100 gallons of wash water processed. The subsystem removed approximately 98 percent and virtually 100 percent of the phosphates and surfactants, respectively, from the wash water.

Hall, J. B., Jr.↗

Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

Hall, J. B., Jr.↗

Hyperfiltration wash water recovery subsystem - Design and test results

The Hyperfiltration Wash Water Recovery (HWWR) subsystem, designed to offer low-power high-volume wash water purification for extended mission spacecraft, is discussed in terms of preprototype design and configuration. Heated wash water collected from the shower, hand wash, and laundry flows into a temperature-controlled (374 K) waste storage tank. Two parallel 25 micron absolute filters at the tank outlet remove large particles from the feed stream. A positive displacement feed pump delivers wash water to the hyperfiltration module at a constant flow rate of 0.20 lpm with discharge pressure variations from 4181-7239 Kpa. The hyperfiltration membrane module is a single-pass design including 36 porous stainless steel tubes, and is designed to provide an approximate water recovery rate of 90 percent. Permeate and brine water flows are monitored by flow meters, and removal of urea and ammonia is achieved by adding 15 percent NaOCl solution to the permeate fluid stream. An alternate module design using two diameters of tubing (allowing a smaller pressure drop and a larger membrane area) gave a superior predicted performance over the first module with larger tubing throughout.

Reysa, R. P.↗

Irreversible Wash Aid Additive for Cesium Mitigation. Small-Scale Demonstration and Lessons Learned

The Irreversible Wash Aid Additive process has been under development by the U.S. Environmental Protection Agency (EPA) and Argonne National Laboratory (Argonne). This process for radioactive cesium mitigation consists of a solution to wash down contaminated structures, roadways, and vehicles and a sequestering agent to bind the radionuclides from the wash water and render them environmentally immobile. The purpose of this process is to restore functionality to basic services and immediately reduce the consequences of a radiologically-contaminated urban environment. Research and development have resulted in a down-selection of technologies for integration and demonstration at the pilot-scale level as part of the Wide Area Recovery and Resiliency Program (WARRP) under the Department of Homeland Security and the Denver Urban Area Security Initiative. As part of developing the methods for performing a pilot-scale demonstration at the WARRP conference in Denver in 2012, Argonne conducted small-scale field experiments at Separmatic Systems. The main purpose of these experiments was to refine the wash water collection and separations systems and demonstrate key unit operations to help in planning for the large scale demonstration in Denver. Since the purpose of these tests was to demonstrate the operations of the system, we used no radioactive materials. After a brief set of experiments with the LAKOS unit to familiarize ourselves with its operation, two experiments were completed on two separate dates with the Separmatic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technology Solutions Case Study: Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States

In many two-story homes, there are attic spaces above the first-floor of the home that border portions of the second-story conditioned space. These spaces have breaches of the air and thermal boundaries, creating a phenomenon known as wind washing. This can cause attic air above the first-floor space to be driven into the cavity between the first and second floors by wind, thermal buoyancy forces, or mechanical driving forces as well as circulation of hot attic air against the wallboard because of gaps between insulation batts installed on knee walls and the gypsum wallboard. In this project, the U.S. Department of Energy team Building America Partnership for Improved Residential Construction (BA-PIRC) investigated wind washing in 56 homes. The goals were to identify the failure mechanisms that lead to wind washing, characterize the pathways for air and heat to enter the house, and evaluate the seasonal energy savings and peak demand reduction that can result from repairing these wind washing problems. Based on this research, the team developed recommendations for cost-effective retrofit solutions and information that can help avoid these problems in new construction.

air barrier↗

Evaluating Solid Sorbents for Recycling Wash Waters Containing Strontium and Calcium

We have developed a system for rapid reduction of radioactive contamination and capture and recycling of contaminated wash waters called Integrated Wash-Aid, Treatment, and Emergency Reuse System (IWATERS). IWATERS prescribes the use of wash waters containing salt additives to enhance the removal of radionuclides from various surfaces and solid sorbents to remove the radionuclides selectively. One possible additive to the wash water is Ca2+ . However, the concentration of this ion can have a very strong detrimental effect on the ability of sequestration agents to sorb strontium effectively. A literature review, batch tests, and surface complexation modeling revealed a few sorbent options for Sr2+ in the presence of Ca2+. Engineered silicotitanate sorbents exhibited superior Kd values in the presence of Ca2+ but have significant drawbacks in cost and availability.

Oster, Christopher↗

Radioactive Waste Sludge Washing and Demonstration of the Nitric-Glycolic Acid Flowsheet for Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch (SB) is processible. During processing of SB9, DWPF will be transitioning from the Nitric-Formic Acid (NFA) flowsheet to the Nitric-Glycolic Acid (NGA) flowsheet. Thus, the qualification of SB10 was requested to only be performed using the NGA flowsheet. In order to qualify the batch for the NGA flowsheet, Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles, designated SC-19, were performed using SB10 Tank 51 sample material. SRNL received Tank 51 material in the midst of Tank Farm washing. SRNL continued the washing in the SRNL Shielded Cells. The SRNL process included the addition of Sodium Reactor Experiment (SRE) material from H Canyon, simulating the transfer of SRE from H Canyon to Tank 51 during Tank Farm washing. The washed SB10 Tank 51 material, with SRE, was characterized prior to flowsheet qualification testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wash water recovery system

The Wash Water Recovery System (WWRS) is intended for use in processing shower bath water onboard a spacecraft. The WWRS utilizes flash evaporation, vapor compression, and pyrolytic reaction to process the wash water to allow recovery of potable water. Wash water flashing and foaming characteristics, are evaluated physical properties, of concentrated wash water are determined, and a long term feasibility study on the system is performed. In addition, a computer analysis of the system and a detail design of a 10 lb/hr vortex-type water vapor compressor were completed. The computer analysis also sized remaining system components on the basis of the new vortex compressor design.

Deckman, G.↗

Wash water waste pretreatment system study

The use of real wash water had no adverse effect on soap removal when an Olive Leaf soap based system was used; 96 percent of the soap was removed using ferric chloride. Numerous chemical agents were evaluated as antifoams for synthetic wash water. Wash water surfactants used included Olive Leaf Soap, Ivory Soap, Neutrogena and Neutrogena Rain Bath Gel, Alipal CO-436, Aerosol 18, Miranol JEM, Palmeto, and Aerosol MA-80. For each type of soapy wash water evaluated, at least one antifoam capable of causing nonpersistent foam was identified. In general, the silicones and the heavy metal ions (i.e., ferric, aluminum, etc.) were the most effective antifoams. Required dosage was in the range of 50 to 200 ppm.