Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “W1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Testing for Controlled Rapid Pressurization

Borehole W1 is a NQ core hole drilled at our test site in Socorro. The rock is rhyolite. Borehole W1 which was used to test gas-gas explosive mixtures is 55 feet deep with casing (pinkish in the drawing) set to 35 feet. The model is a representation of the borehole and the holes we cored around the central borehole after the test. The brown colored core holes showed dye when we filled W1 with water and slightly pressurized it. This indicates there was some path between W1 and the colored core hole. The core holes are shown to their TD in the drawing. The green plane is a fracture plane which we believe is the result of the explosions of the gas mixture in W1. Data resource is a 2D .pdf Solid Works Drawing of borehole W1.

15 GEOTHERMAL ENERGY↗

Scission of the Five-Membered Ring in 1- H -Inden-1-one C 9 H 6 O and Indenyl C 9 H 7 in the Reactions with H and O Atoms

Quantum chemical G3(MP2,CC)//B3LYP/6-311G(d,p) calculations of the C 9 H 7 O potential energy surface were utilized to investigate the mechanism of the 1-H-inden-1-one (C 9 H 6 O) + H and indenyl (C 9 H 7 ) + O reactions and were combined with Rice–Ramsperger–Kassel–Marcus Master Equation (RRKM-ME) calculations to predict temperature- and pressure-dependent reaction rate constants and product branching ratios. The most favorable reaction pathways for C 9 H 6 O + H lead to the bimolecular C 8 H 7 + CO products, which are slightly endothermic with respect to the reactants. The reaction begins with H addition to the ortho or meta C atoms in the five-membered ring, C 9 H 6 O + H → w2/w3, and then proceeds by isomerization to w1, (w3 →) w2 → w1. From thereon, the w1 → w9 → w8 → p1 and w2 → w8 → p1 pathways lead to ortho-vinyl phenyl + CO, whereas w1 → w10 → w11 → p2 and C 9 H 6 O + H → w10 → w11 → p2 produce styrenyl + CO. The results of the RRKM-ME calculations showed that only the well-skipping C 9 H 6 O + H → C 8 H 7 (p1/p2) + CO mechanism is relevant under combustion conditions. A comparison with a smaller prototype 2,4-cyclopentadienone + H → C 4 H 5 + CO reaction demonstrated that the H atom is a less efficient destroyer of a cyclopentadienone-like moiety when this moiety is linked to an aromatic or a PAH structure. The C 9 H 7 + O reaction begins with highly exothermic barrierless addition of the oxygen atom to the radical site in the five-membered ring of indenyl producing w1 and then, the reaction mostly proceeds by β-scission in the five-membered ring, which may be preceded by H migration to w2 or w10, and completes by the CO loss forming the highly exothermic C 8 H 7 radical products. Modified Arrhenius expressions for the rate constants of all reactions pertinent to the formation of C 8 H 7 + CO from C 9 H 6 O + H, C 9 H 7 + H, and unimolecular decomposition of benzopyranyl have been generated and suggested for combustion kinetic modeling. Furthermore, it is concluded that the oxidation reactions of a five-membered ring with atomic oxygen remain fast in the presence of attached or surrounding six-membered rings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-73: Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector

Purpose: The aim of this work was to determine experimentally the effective point of measurement (EPOM) in clinical electron beams for three cylindrical ionization chambers using a commercial scintillation detector as a reference detector. Methods: Percent depth dose (PDD) curves were measured using an Exradin W1 scintillation detector and were used as a representative PDD to water. Depth dose curves were measured with the Exradin A18, A1SL, and A28 ionization chambers. The raw ionization chamber curve data were corrected by the chamber fluence perturbation correction factor and restricted mass collisional stopping power ratio at each depth to obtain a percent depth dose curve to the gas volume (PDDGV) of the detector. Ratios of the W1 PDD to the ion chamber PDDGV were calculated for each measurement depth. The W1 PDD curve was shifted by small depth increments, Δz, until the ratio of the W1 PDD to the ion chamber PDDGV was depth-independent (optimal Δz). A MATLAB routine was developed to determine the optimal Δz value. Results: The optimal Δz shift was used as an estimate of the EPOM for each chamber. The average calculated EPOM shifts (expressed as a fraction of the chamber cavity radius) for the A18, A1SL, and A28 ionization chambers were 0.21 ± 0.04, 0.10 ± 0.05, and 0.22 ± 0.03, respectively. Conclusion: The experimentally determined EPOM values for the A18 and A1SL in this work agreed with the simulated values of Muir and Rogers (MedPhys 2014). The results also indicate that the Exradin W1 scintillator is water equivalent for electron energies of 6 MeV, 9 MeV, 12 MeV, and 16 MeV. In addition, we confirmed that the AAPM TG51 recommended EPOM shift of 0.5 times the cavity radius is not accurate for the A18 and A1SL chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CatWISE Preliminary Catalog: Motions from WISE and NEOWISE Data

CatWISE is a program to catalog sources selected from combined WISE and NEOWISE all-sky survey data at 3.4 and 4.6 μm (W1 and W2). The CatWISE Preliminary Catalog consists of 900,849,014 sources measured in data collected from 2010 to 2016. This data set represents four times as many exposures and spans over 10 times as large a time baseline as that used for the AllWISE Catalog. CatWISE adapts AllWISE software to measure the sources in coadded images created from six-month subsets of these data, each representing one coverage of the inertial sky, or epoch. The catalog includes the measured motion of sources in eight epochs over the 6.5 yr span of the data. From comparison to Spitzer, signal-to-noise ratio = 5 limits in magnitudes in the Vega system are W1 = 17.67 and W2 = 16.47, compared to W1 = 16.96 and W2 = 16.02 for AllWISE. From comparison to Gaia, CatWISE positions have typical accuracies of 50 mas for stars at W1 = 10 mag and 275 mas for stars at W1 = 15.5 mag. Proper motions have typical accuracies of 10 mas yr -1 and 30 mas yr -1 for stars with these brightnesses, an order of magnitude better than from AllWISE. The catalog is available in the WISE/NEOWISE Enhanced and Contributed Products area of the NASA/IPAC Infrared Science Archive.

79 ASTRONOMY AND ASTROPHYSICS↗

Being WISE. I. Validating stellar population models and M {sub *}/L ratios at 3.4 and 4.6 μm

Using data from the Wide-field Infrared Survey Explorer mission, we have measured near infra-red (NIR) photometry of a diverse sample of dust-free stellar systems (globular clusters, dwarf and giant early-type galaxies) which have metallicities that span the range -2.2 < [Fe/H] (dex) < 0.3. This dramatically increases the sample size and broadens the metallicity regime over which the 3.4 (W1) and 4.6 μm (W2) photometry of stellar populations have been examined. We find that the W1 – W2 colors of intermediate and old (>2 Gyr) stellar populations are insensitive to the age of the stellar population, but that the W1 – W2 colors become bluer with increasing metallicity, a trend not well reproduced by most stellar population synthesis (SPS) models. In common with previous studies, we attribute this behavior to the increasing strength of the CO absorption feature located in the 4.6 μm bandpass with metallicity. Having used our sample to validate the efficacy of some of the SPS models, we use these models to derive stellar mass-to-light ratios in the W1 and W2 bands. Utilizing observational data from the SAURON and ATLAS3D surveys, we demonstrate that these bands provide extremely simple, yet robust stellar mass tracers for dust free older stellar populations that are freed from many of the uncertainties common among optical estimators.

79 ASTRONOMY AND ASTROPHYSICS↗

Giant wormholes in ghost-free bigravity theory

We study Lorentzian wormholes in the ghost-free bigravity theory described by two metrics, g and f. Wormholes can exist if only the null energy condition is violated, which happens naturally in the bigravity theory since the graviton energy-momentum tensors do not apriori fulfill any energy conditions. As a result, the field equations admit solutions describing wormholes whose throat size is typically of the order of the inverse graviton mass. Hence, they are as large as the universe, so that in principle we might all live in a giant wormhole. The wormholes can be of two different types that we call W1 and W2. The W1 wormholes interpolate between the AdS spaces and have Killing horizons shielding the throat. The Fierz-Pauli graviton mass for these solutions becomes imaginary in the AdS zone, hence the gravitons behave as tachyons, but since the Breitenlohner-Freedman bound is fulfilled, there should be no tachyon instability. For the W2 wormholes the g-geometry is globally regular and in the far field zone it becomes the AdS up to subleading terms, its throat can be traversed by timelike geodesics, while the f-geometry has a completely different structure and is not geodesically complete. There is no evidence of tachyons for these solutions, although a detailed stability analysis remains an open issue. It is possible that the solutions may admit a holographic interpretation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-C-304-03: Experimental Investigation On the Accuracy of Plastic Scintillation Dosimeters in Small Fields

Purpose: To investigate the accuracy of the Exradin W1 (SI) and of an “in-house” plastic scintillation dosimeter (CHUQ PSD) in small radiation fields. Methods: Output factor (OF) measurements with the W1 and CHUQ PSD were performed for field sizes of 0.5 x 0.5, 1 x 1 and 2 x 2 cm{sup 2}. Both detectors were placed parallel to the central axis (CAX) in water. The spectrum discrimination calibration method was performed in each set-up to account for the Cerenkov (CRV) signal created in the fiber. The OFs were compared to the expected field factors in water derived using i) Monte Carlo (MC) simulations of an accurate accelerator model and ii) microLion (PTW) and D1V diode (SI) OFs. MC-derived correction factors were applied to both the microLion and D1V OFs. For the CHUQ PSD the calibration was repeated in water (// CAX), solid water (perpendicular to CAX) and under a shielded configuration. The signal was collected using a spectrometer (wavelength range = 185–1100 nm). Spectral analysis was performed to evaluate potential changes of the spectral distributions under the various calibration set-up configurations. Results: The W1 OFs presented an over-response for the 0.5 x 0.5 cm{sup 2} in the range of 3 – 4.1% relative to the expected field factor. The CHUQ PSD presented an under-response in the range of 1.5 – 2.7%, without accounting for volume averaging. The CRV spectra under the various calibration procedures appeared similar to each other and only minor changes were observed to the respective OFs. Conclusion: The W1 and CHUQ PSD can be used in small fields down to a 1 x 1 cm{sup 2} field size. Discrepancies were encountered between the two detectors for the smallest field size of 0.5 x 0.5 cm{sup 2} with the CHUQ PSD exhibiting a closer agreement to the expected field factor. Funding sources: 1) Alexander S. Onassis Public Benefit Foundation in Greece and 2) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council, Grant number: 432290, RGPIN-2014-06475.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-506: Intercomparison Study On Small Field Output Factor Measurements

Purpose In radiotherapy, uncertainties due to small field measurements (SFM) introduce systematic errors to the treatment process and the development of new dosimeters for quality assurance programs is a challenge. In this work we analyze the behavior of seven detectors measuring output factors of 6MV photon beam. Methods The dosimeters employed are: a single cristal diamond detector (SCCD) developed at the University of Rome Tor Vergata, a silicon diode developed within the project MAESTRO, a IBA Razor silicon diode, A1SL and A26 Exradin ion chambers, an EBT3 Gafchromic film and the Exradin W1 Scintillator.Diamond sensitive volume is a cylinder 2.2mm in diameter and 1μm thick. MAESTRO diode is 2×2mm2 active area. Razor sensitive volume is a cylinder 0.6 mm in diameter and 0.02 mm thick. A16 and A1Sl have a collecting volume of 0,015cc and 0,053cc. The W1 is an optical fiber with an active volume of 0.002cc. All measurements were performed in a water phantom, with detector positioned at the isocenter (SSD=90cm, d=10cm), MAESTRO diode being sandwiched in solid water to obtain an equivalent experimental setup. Results These measurements are challenging due to the absence of charged particle equilibrium conditions, detector size and positioning problems. They are in good agreement among each other, especially GAF, Razor, W1 and SCDD. Maximum deviations reported are related to the field 0.8×0.8cm2 for MAESTRO and chambers data with respect to EBT3: around 15% (A1SLvsEBT3), 16% (MAESTROvsEBT3). Razor and W1 show a deviation around 3% with respect to SCDD. Conclusion In this work measurements made with a variety of detectors are compared. These study show the possibility to choose different detectors for SFM and that smaller ion chambers are still not competitive with solid state detectors. Silicon, diamond and optical fiber dosimeters show a similar behavior with minor discrepancies for the smallest field.

60 APPLIED LIFE SCIENCES↗

Full-Depth Coadds of the WISE and First-Year NEOWISE-Reactivation Images

The Near Earth Object Wide-field Infrared Survey Explorer (NEOWISE) Reactivation mission released data from its first full year of observations in 2015. This data set includes ~2.5 million exposures in each of W1 and W2, effectively doubling the amount of WISE imaging available at 3.4 μm and 4.6 μm relative to the AllWISE release. In this paper, we have created the first ever full-sky set of coadds combining all publicly available W1 and W2 exposures from both the AllWISE and NEOWISE-Reactivation (NEOWISER) mission phases. We employ an adaptation of the unWISE image coaddition framework, which preserves the native WISE angular resolution and is optimized for forced photometry. By incorporating two additional scans of the entire sky, we not only improve the W1/W2 depths, but also largely eliminate time-dependent artifacts such as off-axis scattered moonlight. We anticipate that our new coadds will have a broad range of applications, including target selection for upcoming spectroscopic cosmology surveys, identification of distant/massive galaxy clusters, and discovery of high-redshift quasars. In particular, our full-depth AllWISE+NEOWISER coadds will be an important input for the Dark Energy Spectroscopic Instrument selection of luminous red galaxy and quasar targets. Our full-depth W1/W2 coadds are already in use within the DECam Legacy Survey (DECaLS) and Mayall z-band Legacy Survey (MzLS) reduction pipelines. Finally, much more work still remains in order to fully leverage NEOWISER imaging for astrophysical applications beyond the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

A Study of Quasar Selection in the Supernova Fields of the Dark Energy Survey

In this paper, we present a study of quasar selection using the supernova fields of the Dark Energy Survey (DES). We used a quasar catalog from an overlapping portion of the SDSS Stripe 82 region to quantify the completeness and efficiency of selection methods involving color, probabilistic modeling, variability, and combinations of color/probabilistic modeling with variability. In all cases, we considered only objects that appear as point sources in the DES images. We examine color selection methods based on the Wide-field Infrared Survey Explorer (WISE) mid-IR W1-W2 color, a mixture of WISE and DES colors (g - i and i-W1), and a mixture of Vista Hemisphere Survey and DES colors (g - i and i - K). For probabilistic quasar selection, we used XDQSO, an algorithm that employs an empirical multi-wavelength flux model of quasars to assign quasar probabilities. Our variability selection uses the multi-band χ 2 -probability that sources are constant in the DES Year 1 griz-band light curves. The completeness and efficiency are calculated relative to an underlying sample of point sources that are detected in the required selection bands and pass our data quality and photometric error cuts. We conduct our analyses at two magnitude limits, i < 19.8 mag and i < 22 mag. For the subset of sources with W1 and W2 detections, the W1-W2 color or XDQSOz method combined with variability gives the highest completenesses of >85% for both i-band magnitude limits and efficiencies of >80% to the bright limit and >60% to the faint limit; however, the giW1 and giW1+variability methods give the highest quasar surface densities. The XDQSOz method and combinations of W1W2/giW1/XDQSOz with variability are among the better selection methods when both high completeness and high efficiency are desired. We also present the OzDES Quasar Catalog of 1263 spectroscopically confirmed quasars from three years of OzDES observation in the 30 deg 2 of the DES supernova fields. Finally, the catalog includes quasars with redshifts up to z ~ 4 and brighter than i = 22 mag, although the catalog is not complete up to this magnitude limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep Full-sky Coadds from Three Years of WISE and NEOWISE Observations

We have reprocessed over 100 terabytes of single-exposure Wide-field Infrared Survey Explorer ( WISE )/NEOWISE images to create the deepest ever full-sky maps at 3–5 microns. We include all publicly available W1 and W2 imaging—a total of ∼8 million exposures in each band—from ∼37 months of observations spanning 2010 January to 2015 December. Our coadds preserve the native WISE resolution and typically incorporate ∼3× more input frames than those of the AllWISE Atlas stacks. Our coadds are designed to enable deep forced photometry, in particular for the Dark Energy Camera Legacy Survey (DECaLS) and Mayall z-Band Legacy Survey (MzLS), both of which are being used to select targets for the Dark Energy Spectroscopic Instrument. We describe newly introduced processing steps aimed at leveraging added redundancy to remove artifacts, with the intent of facilitating uniform target selection and searches for rare/exotic objects (e.g., high-redshift quasars and distant galaxy clusters). Forced photometry depths achieved with these coadds extend 0.56 (0.46) magnitudes deeper in W1 (W2) than is possible with only pre-hibernation WISE imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

A 3π Search for Planet Nine at 3.4 μm with WISE and NEOWISE

The recent “Planet Nine” hypothesis has led to many observational and archival searches for this giant planet proposed to orbit the Sun at hundreds of astronomical units. While trans-Neptunian object searches are typically conducted in the optical, models suggest Planet Nine could be self-luminous and potentially bright enough at ∼3–5 μm to be detected by the Wide-field Infrared Survey Explorer (WISE). We have previously demonstrated a Planet Nine search methodology based on time-resolved WISE coadds, allowing us to detect moving objects much fainter than would be possible using single-frame extractions. In the present work, we extend our 3.4 μm (W1) search to cover more than three-quarters of the sky and incorporate four years of WISE observations spanning a seven-year time period. This represents the deepest and widest-area WISE search for Planet Nine to date. We characterize the spatial variation of our survey’s sensitivity and rule out the presence of Planet Nine in the parameter space searched at W1 < 16.7 in high Galactic latitude regions (90% completeness).

79 ASTRONOMY AND ASTROPHYSICS↗

RR Lyrae Mid-infrared Period–Luminosity–Metallicity and Period–Wesenheit–Metallicity Relations Based on Gaia DR3 Parallaxes

We present new empirical infrared period–luminosity–metallicity (PLZ) and period–Wesenheit–metallicity (PWZ) relations for RR Lyae based on the latest Gaia Early Data Release 3 (EDR3) parallaxes. The relations are provided in the Wide-field Infrared Survey Explorer (WISE) W1 and W2 bands, as well as in the W(W1, V - W1) and W(W2, V - W2) Wesenheit magnitudes. The relations are calibrated using a very large sample of Galactic halo field RR Lyrae stars with homogeneous spectroscopic [Fe/H] abundances (over 1000 stars in the W1 band), covering a broad range of metallicities (-2.5 ≲ [Fe/H] ≲ 0.0). We test the performance of our PLZ and PWZ relations by determining the distance moduli of both galactic and extragalactic stellar associations: the Sculptor dwarf spheroidal galaxy in the Local Group (finding ${\bar{\mu }}_{0}=19.47\pm 0.06$ ), the Galactic globular clusters M4 (${\bar{\mu }}_{0}=11.16\pm 0.05$ ), and the Reticulum globular cluster in the Large Magellanic Cloud (${\bar{\mu }}_{0}=18.23\pm 0.06$ ). The distance moduli determined through all our relations are internally self-consistent (within ≲0.05 mag) but are systematically smaller (by ~2–3σ) than previous literature measurements taken from a variety of methods/anchors. However, a comparison with similar recent RR Lyrae empirical relations anchored with EDR3 likewise shows, to varying extents, a systematically smaller distance modulus for PLZ/PWZ RR Lyrae relations.

79 ASTRONOMY AND ASTROPHYSICS↗

The CatWISE2020 Catalog

The CatWISE2020 Catalog consists of 1,890,715,640 sources over the entire sky selected from Wide-field Infrared Survey Explorer (WISE) and NEOWISE survey data at 3.4 and 4.6 μm (W1 and W2) collected from 2010 January 7 to 2018 December 13. This data set adds two years to that used for the CatWISE Preliminary Catalog, bringing the total to six times as many exposures spanning over 16 times as large a time baseline as the AllWISE catalog. The other major change from the CatWISE Preliminary Catalog is that the detection list for the CatWISE2020 Catalog was generated using crowdsource from Schlafly et al., while the CatWISE Preliminary Catalog used the detection software used for AllWISE. These two factors result in roughly twice as many sources in the CatWISE2020 Catalog. The scatter with respect to Spitzer photometry at faint magnitudes in the COSMOS field, which is out of the Galactic Plane and at low ecliptic latitude (corresponding to lower WISE coverage depth) is similar to that for the CatWISE Preliminary Catalog. The 90% completeness depth for the CatWISE2020 Catalog is at W1 = 17.7 mag and W2 = 17.5 mag, 1.7 mag deeper than in the CatWISE Preliminary Catalog. In comparison to Gaia, CatWISE2020 motions are accurate at the 20 mas yr-1 level for W1~15 mag sources and at the ~100 mas yr-1 level for W1~17 mag sources. This level of accuracy represents a 12 improvement over AllWISE. Finally, the CatWISE catalogs are available in the WISE/NEOWISE Enhanced and Contributed Products area of the NASA/IPAC Infrared Science Archive.

79 ASTRONOMY AND ASTROPHYSICS↗

Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-C-304-06: Determination of Intermediate Correction Factors for Three Dosimeters in Small Composite Photon Fields Used in Robotic Radiosurgery

Purpose: To calculate using Monte-Carlo the intermediate and total correction factors (CFs) for two microchambers and a plastic scintillator for composite fields delivered by the CyberKnife system. Methods: A linac model was created in BEAMnrc by matching percentage depth dose (PDD) curves and output factors (OFs) measured using an A16 microchamber with Monte Carlo calculations performed in egs-chamber to explicitly model detector response. Intermediate CFs were determined for the A16 and A26 microchambers and the W1 plastic scintillator in fourteen different composite fields inside a solid water phantom. Seven of these fields used a 5 mm diameter collimator; the remaining fields employed a 7.5 mm collimator but were otherwise identical to the first seven. Intermediate CFs are reported relative to the respective CF for a 60 mm collimator (800 mm source to detector distance and 100 mm depth in water). Results: For microchambers in composite fields, the intermediate CFs that account for detector density and volume were the largest contributors to total CFs. The total CFs for the A26 were larger than those for the A16, especially for the 5 mm cone (1.227±0.003 to 1.144±0.004 versus 1.142±0.003 to 1.099±0.004), due to the A26’s larger active volume (0.015 cc) relative to the A16 (0.007 cc), despite the A26 using similar wall and electrode material. The W1 total and intermediate CFs are closer to unity, due to its smaller active volume and near water-equivalent composition, however, 3–4% detector volume corrections are required for 5 mm collimator fields. In fields using the 7.5 mm collimator, the correction is nearly eliminated for the W1 except for a non-isocentric field. Conclusion: Large and variable CFs are required for microchambers in small composite fields primarily due to density and volume effects. Corrections are reduced but not eliminated for a plastic scintillator in the same fields.

60 APPLIED LIFE SCIENCES↗

Design and Characterization of New 90 GHz Detectors for the Cosmology Large Angular Scale Surveyor (CLASS)

The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert. CLASS is designed to measure “E-mode” (even parity) and “B-mode” (odd parity) polarization patterns in the Cosmic Microwave Background (CMB) over large angular scales with the aim of improving our understanding of inflation, reionization, and dark matter. CLASS is currently observing with three telescopes covering four frequency bands: one at 40 GHz (Q); one at 90 GHz (W1); and one dichroic system at 150/220 GHz (G). In these proceedings, we discuss the updated design and in-lab characterization of new 90 GHz detectors. The new detectors include design changes to the transition-edge sensor (TES) bolometer architecture, which aim to improve stability and optical efficiency. We assembled and tested four new detector wafers, to replace four modules of the W1 focal plane. These detectors were installed into the W1 telescope, and will achieve first light in the austral winter of 2022. We present electrothermal parameters and bandpass measurements from in-lab dark and optical testing. From in-lab dark tests, we also measure a median NEP of 12.3 aW √ s across all four wafers about the CLASS signal band, which is below the expected photon NEP of 32 aW √ s from the field. We therefore expect the new detectors to be photon noise limited."

Carolina Nunez↗

Structure and Thermal Stability of (H 2 O) 4 Tetrahedron and (H 2 O) 6 Hexagon Adsorbed on NaY Zeolite Studied by Synchrotron-Based Time-Resolved X-ray Diffraction

Water adsorption and desorption features play an important role in determining the adsorptive and catalytic properties of zeolites. In this study, the extraframework structure (water and cations) in NaY faujasite zeolite was studied by synchrotron-based in situ time-resolved X-ray diffraction (TR-XRD) in combination with the Rietveld refinement method. It was observed that Na cations locating at different sites migrated between each other during the dehydration process. Water molecules at three separate sites showed interesting geometries: (H 2 O) 4 tetrahedron W1, (H 2 O) 6 ice-like hexagonal W2, and disordered triangle W3. Interactions between each form of water and Na cations were deeply investigated. Here, the stability of the waters followed the sequence of W1 > W3 > W2. This work provides insights into both framework structure and cation positions of model zeolite under actual working conditions, which helps fully understand the properties of zeolites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗