Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative Assessment of Parent Well Effect on Hydraulic Fracture Propagation at HFTS2: Insights from Cross-Well Strain Measurements and Microseismic Data

Understanding fracture propagation behavior is essential for optimizing hydraulic fracturing in unconventional reservoirs. This study demonstrates the value of integrating Low-Frequency Distributed Acoustic Sensing (LF-DAS) and microseismic data, which together provide a more complete picture of fracture growth. Using data from Hydraulic Fracturing Test Site 2 (HFTS2), we identify stress changes in depletion zones induced by parent wells as a key factor influencing fracture propagation. This result is shown by new measurements of in-situ fracture propagation velocity and fracture-hit volume (fluid volume at fracture hit?) from LF-DAS and event density from microseismic. These findings highlight the importance of considering parent well effects, well spacing, and stimulation sequencing in completion design to improve reservoir development and production efficiency.

depletion zones↗

A mineral precipitation model based on the volume of fluid method

A novel volume of fluid method is presented for mineral precipitation coupled with fluid flow and reactive transport. The approach describes the fluid-solid interface as a smooth transitional region, which is designed to provide the same precipitation rate and viscous drag force as a sharp interface. Specifically, the governing equation of mineral precipitation is discretized by an upwind scheme, and a rigorous effective viscosity model is derived around the interface. The model is validated against analytical solutions for mineral precipitation in channel and ring-shaped structures. It also compares well with interface tracking simulations of advection-diffusion-reaction problems. Here, the methodology is finally employed to model mineral precipitation in fracture networks, which is challenging due to the low porosity and complex geometry. Compared to other approaches, the proposed model has a concise algorithm and contains no free parameters. In the modeling, only the pore space requires meshing, which improves the computational effciency especially for low-porosity media.

58 GEOSCIENCES↗

A scalable compressible volume of fluid solver using a stratified flow model

Here, in this paper, a Volume of Fluid method which uses a Stratified Flow model for flux calculation is proposed to solve a compressible multiphase flow in a way that has high parallel efficiency. The solver is part of an open-source computing tool to study fuel entrainment and combustion in the application of paraffin-based hybrid rocket motors. This paper focuses on the compressible Volume of Fluid solver for the liquid and gaseous phases in this environment. This solver uses perfect gas and stiffened gas models for equation of state, with the ability to easily add other models as desired. Additionally a comparison of a Riemann solver versus an AUSM+up scheme is conducted, showing improvement with the later in the solution of multiphase flows. This solver successfully reproduces shock tube cases with the expected accuracy, as well as simulating two-dimensional shear and gravity-driven flows. Results also show that the code is able to utilize a Stratified Flow model to evaluate shear flow without the need for interface reconstruction or gradient calculations. Finally, it is shown that the solver has near-ideal scaling under strong scaling tests as well as good performance in static scaling, giving improved performance over current options and implying future advancement of high-performance computing efficiency for multiphase flow solvers.

97 MATHEMATICS AND COMPUTING↗

Fluid flow volume measurements using a capacitance/conductance probe system

A probe system has been developed to measure the flow volume of a single fluid passing through an orifice or flow line. The system employs both capacitance and a conductance probe at the orifice, together with phase detection and data acquisition circuitry to measure flow volume and salinity under low or zero gravity conditions. A wide variety of frequencies can be used for the radio frequency (RF) signal source which is chosen primarily by the capacitance of the orifice probe and the fluid passing through the orifice. Rapid measurements are made using the reflected signal from the orifice probe to determine the 'instantaneous' permittivity of the fluid/gas mixture passing through. The 'instantaneous' measurements are integrated over time to determine flow volume. Analysis reveals that a narrow orifice helps to reduce non-linearities caused by differing flow rates. The geometry of 'deflectors' and 'directors' for the flowing fluid are important in obtaining linearity. Measured data shows that a volume measurement accuracy of approximately four percent can be consistently achieved. The prototype hardware system and associated software have been optimized and are available for further applications. The system has immediate application in low or zero gravity environments for measurements of urine or other liquid volumes.

Nguyen, T. X.↗

Constraining maximum event magnitude during injection-triggered seismicity

Abstract Understanding mechanisms controlling fluid injection-triggered seismicity is key in defining strategies to ameliorate it. Recent triggered events (e.g. Pohang, Mw 5.5) have exceeded predictions of average energy release by a factor of >1000x, necessitating robust methodologies to both define critical antecedent conditions and to thereby constrain anticipated event size. We define maximum event magnitudes resulting from triggering as a function of pre-existing critical stresses and fluid injection volume. Fluid injection experiments on prestressed laboratory faults confirm these estimates of triggered moment magnitudes for varied boundary conditions and injection rates. In addition, observed ratios of shear slip to dilation rates on individual faults signal triggering and may serve as a measurable proxy for impending rupture. This new framework provides a robust method of constraining maximum event size for preloaded faults and unifies prior laboratory and field observations that span sixteen decades in injection volume and four decades in length scale.

58 GEOSCIENCES↗

User Interactive Software for Analysis of Human Physiological Data

Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

Cowings, Patricia S.↗

Development, Verification and Validation of Parallel, Scalable Volume of Fluid CFD Program for Propulsion Applications

There are many instances involving liquid/gas interfaces and their dynamics in the design of liquid engine powered rockets such as the Space Launch System (SLS). Some examples of these applications are: Propellant tank draining and slosh, subcritical condition injector analysis for gas generators, preburners and thrust chambers, water deluge mitigation for launch induced environments and even solid rocket motor liquid slag dynamics. Commercially available CFD programs simulating gas/liquid interfaces using the Volume of Fluid approach are currently limited in their parallel scalability. In 2010 for instance, an internal NASA/MSFC review of three commercial tools revealed that parallel scalability was seriously compromised at 8 cpus and no additional speedup was possible after 32 cpus. Other non-interface CFD applications at the time were demonstrating useful parallel scalability up to 4,096 processors or more. Based on this review, NASA/MSFC initiated an effort to implement a Volume of Fluid implementation within the unstructured mesh, pressure-based algorithm CFD program, Loci-STREAM. After verification was achieved by comparing results to the commercial CFD program CFD-Ace+, and validation by direct comparison with data, Loci-STREAM-VoF is now the production CFD tool for propellant slosh force and slosh damping rate simulations at NASA/MSFC. On these applications, good parallel scalability has been demonstrated for problems sizes of tens of millions of cells and thousands of cpu cores. Ongoing efforts are focused on the application of Loci-STREAM-VoF to predict the transient flow patterns of water on the SLS Mobile Launch Platform in order to support the phasing of water for launch environment mitigation so that vehicle determinantal effects are not realized.

West, Jeff↗

Water Metabolism and Fluid Compartment Volumes in Humans at Altitude. A Compendium of Research (1914 - 1996)

This compendium includes abstracts and synopses of clinical observations and of more basic studies involving physiological mechanisms concerning interaction of water metabolism and fluid compartment volumes in humans during altitude exposure. If the author's abstract or summary was appropriate, it was included. In other cases a more detailed synopsis of the paper was prepared under the subheadings Purpose, Methods, Results, and Conclusions. Author and subject indices are provided, plus an additional selected bibliography of related work of those papers received after the volume was being prepared for publication. This volume includes material published from 1914 through 1995.

Chou, J. L.↗

Exercise Increases the Cardiovascular Stimulus Provided by Artificial Gravity

We investigated fluid shifts and regulatory responses to variations of posture, exercise, Gz level and radius of rotation in subjects riding NASA Ames 20G centrifuge. Results are from 4 protocols that address radius and exercise effects only. Protocol A: After 10 min supine control, 12 healthy men (35 plus or minus 9 yr, 82.8 plus or minus 7.9 kg) were exposed to rotational 1 Gz (2.5 m radius) for 2 min followed by 20 min alternating between 1 and 1.25 Gz. Blood samples were taken pre and post spin. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 8.3 m. Protocol D: Same as B but at 8.3 m. The 8 subjects who completed all protocols, increased heart rate (HR) from control, on average, by: A: 5, B: 39, C: 11, D: 44 bpm. For thoracic fluid volume, (bioimpedance), the 8 subjects changed from control, on average: A: -394, B: -548, C: -537, D: -708 mL. For thigh fluid volume, changes from control, on average, were: A: -137, B: 129, C: -75, D: 159 mL. Hematocrit changes from control were: A: 2.3, B: 3.5, C: 2.3, D: 4.3 %. Radius effects were mild and included greater loss of fluid from the thorax, less fluid loss from the thigh and increased heart rate at the longer radius. Pre-acceleration exercise effects were more dramatic and included additional loss of fluid from the chest, increased fluid volume of the thigh, increased hematocrit and greater heart rate increases. We propose that short bouts of intense exercise can be used to magnify the cardiovascular stress delivered by artificial gravity (AG) training and the combination of AG with exercise training can be fine-tuned to preserve orthostatic tolerance of astronauts during spaceflight.

Howarth, M. S.↗

Completion Effects on Diagnosing Multistage Facture Treatments with Distributed Temperature Sensing

Summary Distributed temperature sensing (DTS) is a valuable tool to diagnose multistage hydraulic fracture treatments. When a stage interval is shut in, the clusters that take more fluid during pumping warm up more slowly. Therefore, the fluid volume injected into each cluster can be quantitatively interpreted by numerical inversion of the warm-back temperature behavior. This general concept assumes that the different warm-back behavior is controlled by only the injected fluid volume; however, recent observations of DTS data indicate that completion configurations significantly influence the warm-back behavior. This paper investigates the completion effects on the DTS interpretation. In ideal conditions, when a stage is fractured, the upstream stage intervals should show an almost uniform temperature that is close to the injected fluid temperature. This is due to the high fluid velocity of injected fluid in the wellbore, and the upstream intervals have not been perforated (noncommunicating intervals), so the only heat transfer is heat conduction between the wellbore fluid and the surrounding reservoir. But the field DTS data show considerably irregular variations in temperature along the upstream stage intervals. These variations are caused by the completion effects. The nonuniform temperature profile is caused by different heat transfer behavior induced by completion hardware along the production casing string, such as joints, clamps, and blast protectors, and by the sensing cable location in the cement, as well as the cement quality. Because the varying heat transfer behavior impacts the warm-back behavior as well as the temperature profile, the completion effects need to be considered in DTS interpretation. A method of DTS interpretation considering the completion effects to diagnose multistage fracture treatments was developed. Because the heat transfer between a wellbore and a reservoir depends on the overall heat transfer coefficient describing heat conduction through the completion in a forward model, this parameter needs to be tuned all along the wellbore. To calibrate the completion effect, the temperature inversion is conducted using the temperature measured at a stage interval that is upstream of a stage interval currently being treated. Because the interpreted stage interval is not perforated at that time, the thermal behavior at the noncommunicating interval is governed by only the heat conduction through the completion environment. Once the effective values of the overall heat transfer coefficient are estimated along the interpreted stage interval, they can be assumed to be constant physical parameters. Then, the fluid volume distribution is interpreted by using the effective overall heat transfer coefficient profile along each interval. This study provides a field application of the developed interpretation method. The new interpretation method provides more accurate diagnosis of fracture treatments by DTS interpretation.

Engineering↗

Prosthetic occlusive device for an internal passageway

An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.

Tenney, J. B., Jr.↗

Vorticity-induced flow-focusing leads to bubble entrainment in an inkjet printhead: Synchrotron x-ray and volume-of-fluid visualizations

The oscillatory flows present in an inkjet printhead can lead to strong deformations of the air-liquid interface at the nozzle exit. Such deformations may lead to an inward directed air jet with bubble pinch-off and the subsequent entrainment of an air bubble, which is highly detrimental to the stability of inkjet printing. Understanding the mechanisms of bubble entrainment is therefore crucial to improving print stability. Here, in the present work, we use ultrafast x-ray phase-contrast imaging and direct numerical simulations based on the volume-of-fluid method to study the mechanisms underlying the bubble entrainment in a piezoacoustic printhead. We first demonstrate good agreement between experiments and numerics. We then show the different classes of bubble pinch-off obtained in experiments, and that those were also captured numerically. The numerical results are then used to show that the baroclinic torque, which is generated at the gas-liquid interface due to the misalignment of density and pressure gradients, results in a flow-focusing effect that drives the formation of the air jet from which a bubble can pinch off.

42 ENGINEERING↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Evaporation Submodel Development for Volume of Fluid (eVOF) Method Applicable to Spray-Wall Interaction Including Film Characteristics with Validation at High Pressure and Temperature Conditions

Internal combustion engines have seen a great evolution over the last several decades through application of high pressure direct injection, multiple injections, and other technologies to reduced fuel consumption, NOx, and PM. Although combustion systems with advanced injection strategies have been studied extensively, there exists a significant fundamental knowledge gap on the fuel-spray interactions with the piston surface and chamber walls. Advanced computational codes validated with experimental techniques have to be developed for accurate representation of the drop impingement, fuel film formation, and vaporization. Current engine CFD (Computational Fluid Dynamics) spray models utilize a Lagrangian framework for modeling which lacks critical considerations of the physics pertaining to these interactions and thus requiring extensive parameterization, tuning and validation. The team from Michigan Technological University, University of Massachusetts Dartmouth, and Argonne National Laboratory is composed of experts in sprays, combustion, engines and CFD with a wide spectrum of knowledge including specific expertise in the area under consideration. In the proposed work, a VOF (Volume of Fluid) modeling approach has been adopted for the spray-wall interaction, film formation and spreading, and vaporization. With the inclusion of a vaporization submodel, a more predictive and accurate simulation of the spray-film was performed without extensive need of parameterization and tuning. Extensive experimentation of the spray-wall interaction under the range of conditions matching the thermodynamic and surface temperatures that occur in diesel and gasoline engines were conducted to validate the SWI submodels and for development of the evaporation submodel, which has been implemented in the flow solver.

42 ENGINEERING↗

Design of Accumulators and Liquid/Gas Charging of Single Phase Mechanically Pumped Fluid Loop Heat Rejection Systems

For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.

HRS↗

Fluid shifts and endocrine responses during chair rest and water immersion in man

The effects of external water pressure on intercompartmental fluid volume shifts and endocrine responses in man are investigated. Extracellular fluid volumes and plasma and urine electrolyte and endocrine responses of four male subjects were measured during eight hours of head-out water immersion and 16 hours of recovery bed rest and compared to responses obtained during eight hours of chair rest and 16 hours of bed rest without external hydrostatic pressure obtained in the same subjects five months later. Immersion is found to result in a substantial diuresis with respect to chair rest, accounted for by decreases in extracellular volume. A negative water balance during immersion and a positive water balance during chair rest were observed to be accompanied by a shift of extracellular volume to the intracellular compartment, as well as the suppression of plasma arginine vasopressin and renin activities in both regimes. The vasopressin and renin activity decreases are attributed to the increased central blood volume, and half of the plasma loss in immersed subjects is attributed to the effects of external water pressure.

Greenleaf, J. E.↗