SEARCH · Engineering Papers
Results for “Voltage control”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Voltage-Controlled Sensitivity of the Spin Seebeck Effect in Pt/Y 3 Fe 5 O 12 /MgO/(PbMg 1/3 Nb 2/3 O 3 ) 0.7 (PbTiO 3 ) 0.3 Multiferroic Heterostructures
The characteristics of pure spin current from the longitudinal spin Seebeck effect are investigated at room temperature in Pt / Y 3 Fe 5 O 12 deposited on the ( Pb Mg 1 / 3 Nb 2 / 3 O 3 ) 0.7 ( Pb Ti O 3 ) 0.3 substrate, through which electrostrain can be controllably applied. The applied voltage enables the modification of magnetic anisotropy in the magnetic insulating Y 3 Fe 5 O 12 layer, and thus the sensitivity of the spin Seebeck effect at small magnetic fields, without suppressing the spin Seebeck effect and the inverse spin Hall effect. This is due to the robust intrinsic physical parameters in Pt / Y 3 Fe 5 O 12 . In conclusion, our results pave the way for the application of voltage-controlled pure spin-current devices.
Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders
This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.
Digital voltage-controlled oscillator
Digital voltage-controlled oscillator generates a variable frequency signal controlled linearly about a center frequency with high stability and is phase controlled by an applied voltage. Integration ahead of the digital circuitry provides linear operation with control voltage having appreciable noise components.
Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control
In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.
Multi-Agent Graph-Attention Deep Reinforcement Learning for Post-Contingency Grid Emergency Voltage Control
Grid emergency voltage control (GEVC) is paramount in electric power systems to improve voltage stability and prevent cascading outages and blackouts in case of contingencies. While most deep reinforcement learning (DRL)-based paradigms perform single agents in a static environment, real-world agents for GEVC are expected to cooperate in a dynamically shifting grid. Moreover, due to high uncertainties from combinatory natures of various contingencies and load consumption, along with the complexity of dynamic grid operation, the data efficiency and control performance of the existing DRL-based methods are challenged. To address these limitations, we propose a multi-agent graph-attention (GATT)-based DRL algorithm for GEVC in multi-area power systems. Here, we develop graph convolutional network (GCN)-based agents for feature representation of the graph-structured voltages to improve the decision accuracy in a data-efficient manner. Furthermore, a cutting-edge attention mechanism concentrates on effective information sharing among multiple agents, synergizing different-sized subnetworks in the grid for cooperative learning. We address several key challenges in the existing DRL-based GEVC approaches, including low scalability and poor stability against high uncertainties. Test results in the IEEE benchmark system verify the advantages of the proposed method over several recent multi-agent DRL-based algorithms.
Voltage-controlled magnetic devices
Voltage controlled magnetic components are described. The magnetic components include a thin layer of ferromagnet adjacent to an oxide layer. The magnetic properties of the ferromagnet may be controlled in a reversible manner via application of an external electric field and voltage-induced reversible oxidation of the ferromagnet.
Signal ratio system utilizing voltage controlled oscillators Patent
Voltage controlled oscillators and pulse amplitude modulation for signal ratio system
Optimal Structures for Voltage Controllers in Inverters: Preprint
Output voltage regulation is a primary performance objective in power electronics systems which are not supported by a stiff voltage source. In this paper, we pose an optimal voltage control problem for ac inverter systems and study the structure of the resulting feedback laws. Here, it is demonstrated that the solution to the optimal voltage regulation control problem exhibits an inner current-controller structure even though there are no explicit objectives on tracking current which are targeted. Furthermore, the outer-loop voltage control and inner-loop current control structure is insensitive to the weighting transfer functions used in the optimal control problem. Although the inner-outer structure has been used in prior works, the optimal nature of such a structure was not known. In deriving the optimal controller, we also present a systematic design framework which is cognizant of the physical properties of inverters. Case studies are used to study the optimal controller and its performance.
Voltage-controlled spin–orbit torque switching in W/CoFeB/MgO
Voltage control of magnetism and spintronics have been highly desirable but rarely realized. In this work, we show voltage-controlled spin–orbit torque (SOT) switching in W/CoFeB/MgO films with perpendicular magnetic anisotropy (PMA) with voltage administered through SrTiO 3 with a high dielectric constant. We show that a DC voltage can significantly lower PMA by 45%, reduce switching current by 23%, and increase the damping-like torque as revealed by the first- and second-harmonic measurements. These are characteristics that are prerequisites for voltage-controlled and voltage-select SOT switching spintronic devices.
Nonvolatile voltage controlled molecular spin state switching
Voltage-controlled room temperature isothermal reversible spin crossover switching of [Fe{H 2 B(pz) 2 } 2 (bipy)] thin films is demonstrated. This isothermal switching is evident in thin film bilayer structures where the molecular spin crossover film is adjacent to a molecular ferroelectric. The adjacent molecular ferroelectric, either polyvinylidene fluoride hexafluoropropylene or croconic acid (C 5 H 2 O 5 ), appears to lock the spin crossover [Fe{H 2 B(pz) 2 } 2 (bipy)] molecular complex largely in the low or high spin state depending on the direction of ferroelectric polarization. In both a planar two terminal diode structure and a transistor structure, the voltage controlled isothermal reversible spin crossover switching of [Fe{H 2 B(pz) 2 } 2 (bipy)] is accompanied by a resistance change and is seen to be nonvolatile, i.e., retained in the absence of an applied electric field. Here, the result appears general, as the voltage controlled nonvolatile switching can be made to work with two different molecular ferroelectrics: croconic acid and polyvinylidene fluoride hexafluoropropylene.
Complementary Paired G4FETs as Voltage-Controlled NDR Device
It is possible to synthesize a voltage-controlled negative-differential-resistance (NDR) device or circuit by use of a pair of complementary G4FETs (four-gate field-effect transistors). [For more information about G4FETs, please see the immediately preceding article]. As shown in Figure 1, the present voltage-controlled NDR device or circuit is an updated version of a prior NDR device or circuit, known as a lambda diode, that contains a pair of complementary junction field-effect transistors (JFETs). (The lambda diode is so named because its current-versus- voltage plot bears some resemblance to an upper-case lambda.) The present version can be derived from the prior version by substituting G4FETs for the JFETs and connecting both JFET gates of each G4FET together. The front gate terminals of the G4FETs constitute additional terminals (that is, terminals not available in the older JFET version) to which one can apply control voltages VN and VP. Circuits in which NDR devices have been used include (1) Schmitt triggers and (2) oscillators containing inductance/ capacitance (LC) resonant circuits. Figure 2 depicts such circuits containing G4FET NDR devices like that of Figure 1. In the Schmitt trigger shown here, the G4FET NDR is loaded with an ordinary inversion-mode, p-channel, metal oxide/semiconductor field-effect transistor (inversion-mode PMOSFET), the VN terminal of the G4FET NDR device is used as an input terminal, and the input terminals of the PMOSFET and the G4FET NDR device are connected. VP can be used as an extra control voltage (that is, a control voltage not available in a typical prior Schmitt trigger) for adjusting the pinch-off voltage of the p-channel G4FET and thereby adjusting the trigger-voltage window. In the oscillator, a G4FET NDR device is loaded with a conventional LC tank circuit. As in other LC NDR oscillators, oscillation occurs because the NDR counteracts the resistance in the tank circuit. The advantage of this G4FET-NDR LC oscillator over a conventional LC NDR oscillator is that one can apply a time-varying signal to one of the extra control input terminals (VN or VP) to modulate the conductance of the NDR device and thereby amplitude-modulate the output signal.
80-GHz MMIC HEMT Voltage-Controlled Oscillator
A voltage-controlled oscillator (VCO) that operates in the frequency range from 77.5 to 83.5 GHz has been constructed in the form of a monolithic microwave integrated circuit (MMIC) that includes high-electron-mobility transistors (HEMTs). This circuit is a prototype of electronically tunable signal sources in the 75-to-110-GHz range, needed for communication, imaging, and automotive radar applications, among others. This oscillator (see Figure 1) includes two AlInAs/GaInAs/InP HEMTs. One HEMT serves mainly as an oscillator gain element. The other HEMT serves mainly as a varactor for controlling the frequency: the frequency-control element is its gate-to-source capacitance, which is varied by changing its gate supply voltage. The gain HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle). Grounded coplanar waveguides are used as impedance-matching transmission lines, the input and output matching being chosen to sustain oscillation and maximize output power. Air bridges are placed at discontinuities to suppress undesired slot electromagnetic modes. A high density of vias is necessary for suppressing a parallel-plate electromagnetic mode that is undesired because it can propagate energy into the MMIC substrate. Previous attempts at constructing HEMT-based oscillators yielded circuits with relatively low levels of output power and narrow tuning ranges. For example, one HEMT VCO reported in the literature had an output power of 7 dBm (.5 mW) and a tuning range 2-GHz wide centered approximately at a nominal frequency of 77 GHz. In contrast, as shown in Figure 2, the present MMIC HEMT VCO puts out a power of 12.5 dBm (.18 mW) or more over the 6-GHz-wide frequency range from 77.5 to 83.5 GHz
Antiferromagnetic Parametric Resonance Driven by Voltage-Controlled Magnetic Anisotropy
Voltage-controlled magnetic anisotropy (VCMA) is a low-energy alternative to manipulate the ferromagnetic state, which has been recently also considered in antiferromagnets (AFMs). Here, we theoretically demonstrate that VCMA can be used to excite linear and parametric resonant modes in easy-axis AFMs with perpendicular anisotropy, thus opening the way for an efficient electrical control of the Néel vector and for the detection of high-frequency dynamics. Our work leads to two key results: (i) VCMA parametric pumping experiences the so-called “exchange enhancement” of the coupling efficiency and, thus, is 1–2 orders of magnitude more efficient than microwave magnetic fields or spin-orbit torques, and (ii) it also allows for zero-field parametric resonance, which cannot be achieved by other parametric pumping mechanisms in AFMs with an out-of-plane easy axis. Therefore, we demonstrate that VCMA parametric pumping is the most promising method for coherent excitation and manipulation of AFM order in perpendicular easy-axis AFMs.
Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems
Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.
Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV
In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.
Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations
This paper presents an analysis of grid voltage control strategies for heavy-duty electric vehicle charging stations. The performance of three voltage control approaches—including power factor control, standardized volt-volt ampere reactive (VAR) curve control, and customized volt-VAR curve control—are investigated and evaluated for three different sizes of charging stations, including a single-port charging station, a midsized three-port charging station, and six-port travel center. The charging stations are placed on multiple locations of four different types of distribution systems to obtain a comprehensive performance analysis of the voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics are designed to quantify the performance and contribute to the comprehensive analysis.
Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint
This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.