Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltage Sensitivity Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$\sigma$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online Detection of Low-Quality Synchrophasor Data Considering Frequency Similarity

Here, this letter proposes a new approach for online detection of low-quality synchrophasor data under both normal and event conditions. The proposed approach utilizes the features of synchrophasor data in time and frequency domains to distinguish multiple regional PMU signals and detect low-quality synchrophasor data. It is more effective to detect low-quality data with apparently indistinguishable profiles. Case studies from recorded synchrophasor measurements verify the effectiveness of the proposed approach for detecting low-quality synchrophasor data in frequency, voltage magnitude and voltage angle.

42 ENGINEERING↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Sensitivity analysis of the technical and economic feasibility of converter-interfaced CHP System

The adoption of small-to-medium sized (1MW~20MW) combined heat and power (CHP) system is lagging, especially in industrial and commercial applications. Our prior research has proved that interfacing CHP with grid-ready converters can increase its economic value and technical benefits; this paper is focused on investigating the critical parameters impacting profitability of converter-interfaced CHP, including CHP sizing scenario, energy price, generator cost, converter cost, voltage support price, converter to engine size ratio and interconnection delay. An automatic toolkit for evaluating CHP return on investment (ROI) is developed to enhance the computation capability and efficiency. Based on varying the value of critical parameters, 975 use cases are analyzed. Results show that the profitability of converter-interfaced CHP over directly-coupled CHP is more sensitive to energy price, delays in interconnection process, converter cost and much less to generator cost or voltage support price.

converter, CHP, ROI, economic feasibility, sensiti↗

Fluorescent toxins as ion channel activity sensors.

Voltage gated ion channels (VGICs) shape the electrical character of cells by undergoing structural changes in response to membrane depolarization. High-resolution techniques have provided a wealth of data on individual VGIC structures, but the conformational changes of endogenous channels in live cell membranes have remained unexplored. Here, we describe methods for imaging structural changes of voltage-gated K + channels in living cells, using peptidyl toxins labeled with fluorophores that report specific protein conformations. These Endogenous Voltage-sensor Activity Probes (EVAPs) enable study of both VGIC allostery and function in the context of endogenous live-cell membranes under different physiological states. In this chapter, we describe methods for the synthesis, imaging, and analysis of dynamic EVAPs, which can report K + channel activity in complex tissue preparations via 2-photon excitation microscopy, and environment-sensitive EVAPs, which report voltage-dependent conformational changes at the VGIC-toxin interface. The methods here present the utility of current EVAPs and lay the groundwork for the development of other probes that act by similar mechanisms. EVAPs can be correlated with electrophysiology, offering insight into the molecular details of endogenous channel function and allostery in live cells. This enables investigation of conformational changes of channels in their native, functional states, putting structures and models into a context of live-cell membranes. The expansive array of state-dependent ligands and optical probes should enable probes more generally for investigating the molecular motions of endogenous proteins.

Stewart, Robert↗

Grid Impact Analysis of Heavy-Duty Electric Vehicle Charging Stations

This paper presents a grid impact analysis of heavy-duty electric vehicle (EV) charging stations. In this work, heavy-duty EVs have battery capacities high enough to provide a range of 250-500 miles on a single charge, such as long-haul trucks. Heavy-duty EVs will require extremely fast charging rates to reduce charging time and will induce very high charging loads (at the multiple-megawatt scale) if several vehicles charge at the same time. Therefore, analysis is needed to understand the impact of charging station loads on the electric power grid and set the baseline for developing mitigation plans and necessary system upgrades. We develop a systematic procedure to analyze the potential impact of the placement of charging stations on the grid. Charging load is modeled using a DC fast-charging station model. A voltage load sensitivity matrix approach is leveraged to investigate the challenges of placing charging stations on the feeder. Given the charging load profiles and suggested charging station locations, time-series simulations are performed on various connection points on the feeder to understand the impact. The analysis is performed on both the IEEE 34-bus system and a realistic feeder from California. Initial mitigation solutions are developed based on insights from this analysis.

47 OTHER INSTRUMENTATION↗

Operando detection of Li plating during fast charging of Li-ion batteries using incremental capacity analysis

A major challenge that limits fast charging of Li-ion batteries is lithium (Li) plating on the graphite electrode. Furthermore, it remains challenging to detect and diagnose Li plating in operando during charging. In this work, incremental capacity (IC) analysis is applied while charging graphite-NMC pouch cells over a range of rates from C/2 to 4C. Three-electrode pouch cell measurements and post-mortem SEM imaging was performed to demonstrate that the onset of Li plating is correlated with a specific IC peak. IC analysis was also applied to study the fast-charge performance of multi-layer pouch cells with 3-D anode architectures. The results demonstrate that: 1) IC curves have a characteristic peak that is an indicator of Li plating during fast charging, which grows in magnitude as charging rate increases; 2) the plating IC peak correlates with the voltage minimum of the graphite anode, indicating a transition from intercalation to plating; 3) the plating IC peak is sensitive to small amounts of Li plating; 4) IC analysis can be applied to study Li plating in novel cell architectures; 5) the plating IC peak evolves during extended fast-charge cycling, which is a result of reduced Li plating as the Li inventory decreases.

25 ENERGY STORAGE↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of humidity sensitivity of silicon strip sensors for ATLAS upgrade tracker, pre- and post-irradiation

During the prototyping phase of the new ATLAS Inner-Tracker (ITk) strip sensors, a degradation of the device breakdown voltage at high humidity was observed. Although the degradation was temporary, showing a fast recovery in dry conditions, the study of the influence of humidity on the sensor performance was critical to establish counter-measures and handling protocols during production testing in order to ensure the proper performance of the upgraded detector. The work presented here has the objective to study for the first time the breakdown voltage deterioration in presence of ambient humidity of ATLAS ITk production-layout strip sensors with different surface properties, before and after proton, neutron and gamma irradiations. A study of the humidity sensitivity of miniature ATLAS ITk strip sensors, before and after proton irradiations, is also presented to compare the sensitivity of devices with different sizes. The sensors were also exposed for several days to high humidity with the aim to recreate and evaluate the influence of the detector integration environment expected during the Large Hadron Collider (LHC) Long Shutdown 3 (LS3) in 2026, where the sensors will be exposed to ambient humidity for prolonged times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Algorithms for Screening Electronic Parts for Aging using Power Spectra Analysis (PSA) Data

Understanding the age of semiconductor parts being built into devices and systems is of interest for manufacturing quality control. Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining semiconductor parts. This talk will cover the use of multivariate analysis on both PSA data and conventional current-voltage data generated prior to PSA analysis to create algorithms that can be automated to screen semiconductor parts for aging.

Multari, Rosalie A↗

Deep learning for exploring ultra-thin ferroelectrics with highly improved sensitivity of piezoresponse force microscopy

Hafnium oxide-based ferroelectrics have been extensively studied because of their existing ferroelectricity, even in ultra-thin film form. However, studying the weak response from ultra-thin film requires improved measurement sensitivity. In general, resonance-enhanced piezoresponse force microscopy (PFM) has been used to characterize ferroelectricity by fitting a simple harmonic oscillation model with the resonance spectrum. However, an iterative approach, such as traditional least squares (LS) fitting, is sensitive to noise and can result in the misunderstanding of weak responses. In this study, we developed the deep neural network (DNN) hybrid with deep denoising autoencoder (DDA) and principal component analysis (PCA) to extract resonance information. The DDA/PCA-DNN improves the PFM sensitivity down to 0.3 pm, allowing measurement of weak piezoresponse with low excitation voltage in 10-nm-thick Hf 0.5 Zr 0.5 O 2 thin films. Our hybrid approaches could provide more chances to explore the low piezoresponse of the ultra-thin ferroelectrics and could be applied to other microscopic techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Homogenous Voltage-Matched Strings Using Three-Terminal Tandem Solar Cells: Fundamentals and End Losses

Strings constructed from three-terminal tandem (3TT) solar cells offer the performance benefits of voltage-matching (which reduces sensitivity to spectral variation), but without the subcell voltage isolation required by four-terminal cells. However, the circuitry for a 3TT string can become complex, making circuit analysis more challenging. Here, we illustrate the essential features of “homogenous” voltage-matched (VM) 3TT strings, for which all 3TT cells in the string are nominally identical (with the same design/doping sequence, such that they can be fabricated on the same manufacturing line). Several representative VM string configurations are explicitly considered, and used to describe the general construction of string I(V) curves. End losses intrinsic to these strings are discussed in detail, along with mitigation strategies to minimize their impact. Our analysis agrees with experimental results for eight-cell strings constructed from GaInP/GaAs 3TT devices.

14 SOLAR ENERGY↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Analysis of Critical Conditions for Crack Formation and Propagation, and Optimal Operation of SOECs

A theoretical analysis on crack formation and propagation was performed based on the coupling between the electrochemical process, classical elasticity, and fracture mechanics. The chemical potential of oxygen, thus oxygen partial pressure, at the oxygen electrode-electrolyte interface ( μ O 2 OE∣El ) was investigated as a function of transport properties, electrolyte thickness and operating conditions (e.g., steam concentration, constant current, and constant voltage). Our analysis shows that: a lower ionic area specific resistance (ASR), r i O E , and a higher electronic ASR ( r e O E ) of the oxygen electrode/electrolyte interface are in favor of suppressing crack formation. The μ O 2 O E ∣ E l , thus local pO 2 , are sensitive towards the operating parameters under galvanostatic or potentiostatic electrolysis. Constant current density electrolysis provides better robustness, especially at a high current density with a high steam content. While constant voltage electrolysis leads to greater variations of μ O 2 O E ∣ E l . Constant current electrolysis, however, is not suitable for an unstable oxygen electrode because μ O 2 O E ∣ E l can reach a very high value with a gradually increased r i O E . A crack may only occur under certain conditions when p O 2 T P B > p c r .

42 ENGINEERING↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗