Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Very Low Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantum metrology of low-frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the very high frequency band (VHF) ( ≲ 300 MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ( ∼ 5 GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use nonclassical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc VHF electromagnetic modes as quantum sensors with sensitivity better than the standard quantum limit (SQL). We demonstrate signal upconversion from low frequencies to the microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of 46.9 dB , which is a necessary step towards the realization of full BAE. Published by the American Physical Society 2025

Kuenstner, Stephen E. (ORCID:0000000346128846)↗

The Regulatory Treatment of Low Frequency External Events as Part of a Risk-Informed, Performance-Based Approach

To assist the developing advanced reactor industry in future licensing efforts, the U.S. Department of Energy Advanced Reactor Demonstration Program Regulatory Development area initiated a project at Argonne National Laboratory to examine the regulatory treatment of external hazards as part of a risk-informed performance-based (RIPB) licensing framework. A RIPB licensing framework for advanced reactors built on establishing an affirmative safety case offers the benefits of increased flexibility regarding key design and licensing decisions based on a detailed assessment and understanding of plant risk. Historically, reactor licensing addressed events of very low frequency primarily through the application of design margin and defense-in-depth philosophy. In contrast, RIPB approaches attempt to evaluate these scenarios at a level of detail commensurate with their risk, which often necessitates an explicit treatment of their frequency and associated consequence. While the detailed analysis of low frequency events provides insights that can help justify alternative treatments to past conservatism, the findings are dependent on the quality and confidence associated with the analyses. The assessment of external hazards presents a unique challenge, as their potential frequency of occurrence, especially of large magnitude events, is inherently uncertain given the long return periods in question. This project aims to identify the benefits and challenges of such approaches for advanced reactor vendors and aid in the development of consistent and appropriate analysis methodologies. The paper summarizes project findings and explores the application of various approaches for different external hazards. In addition, the current work also evaluates the application of the quantitative health objectives as a limit on external event risk, as they are a potential regulatory requirement under the current draft 10 CFR Part 53, which is a new technology-neutral reactor licensing pathway in the U.S.

Grabaskas, David↗

BEYONDPLANCK X. Planck Low Frequency Instrument frequency maps with sample-based error propagation

We present Planck Low Frequency Instrument (LFI) frequency sky maps derived within the BEYONDPLANCK framework. This framework draws samples from a global posterior distribution that includes instrumental, astrophysical, and cosmological parameters, and the main product is an entire ensemble of frequency sky map samples, each of which corresponds to one possible realization of the various modeled instrumental systematic corrections, including correlated noise, time-variable gain, as well as far sidelobe and bandpass corrections. This ensemble allows for computationally convenient end-to-end propagation of low-level instrumental uncertainties into higher-level science products, including astrophysical component maps, angular power spectra, and cosmological parameters. We show that the two dominant sources of LFI instrumental systematic uncertainties are correlated noise and gain fluctuations, and the products presented here support – for the first time – full Bayesian error propagation for these effects at full angular resolution. We compared our posterior mean maps with traditional frequency maps delivered by the Planck Collaboration, and find generally good agreement. The most important quality improvement is due to significantly lower calibration uncertainties in the new processing, as we find a fractional absolute calibration uncertainty at 70 GHz of Δg 0 /g 0 = 5 x 10 -5 , which is nominally 40 times smaller than that reported by Planck 2018. However, we also note that the original Planck 2018 estimate has a nontrivial statistical interpretation, and this further illustrates the advantage of the new framework in terms of producing self-consistent and well-defined error estimates of all involved quantities without the need of ad hoc uncertainty contributions. We describe how low-resolution data products, including dense pixel-pixel covariance matrices, may be produced from the posterior samples directly, without the need for computationally expensive analytic calculations or simulations. We conclude that posterior-based frequency map sampling provides unique capabilities in terms of low-level systematics modeling and error propagation, and may play an important role for future Cosmic Microwave Background (CMB) B-mode experiments aiming at nanokelvin precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple Mutations Associated with Emergent Variants Can Be Detected as Low-Frequency Mutations in Early SARS-CoV-2 Pandemic Clinical Samples

Genetic analysis of intra-host viral populations provides unique insight into pre-emergent mutations that may contribute to the genotype of future variants. Clinical samples positive for SARS-CoV-2 collected in California during the first months of the pandemic were sequenced to define the dynamics of mutation emergence as the virus became established in the state. Deep sequencing of 90 nasopharyngeal samples showed that many mutations associated with the establishment of SARS-CoV-2 globally were present at varying frequencies in a majority of the samples, even those collected as the virus was first detected in the US. A subset of mutations that emerged months later in consensus sequences were detected as subconsensus members of intra-host populations. Spike mutations P681H, H655Y, and V1104L were detected prior to emergence in variant genotypes, mutations were detected at multiple positions within the furin cleavage site, and pre-emergent mutations were identified in the nucleocapsid and the envelope genes. Because many of the samples had a very high depth of coverage, a bioinformatics pipeline, “Mappgene”, was established that uses both iVar and LoFreq variant calling to enable identification of very low-frequency variants. This enabled detection of a spike protein deletion present in many samples at low frequency and associated with a variant of concern.

60 APPLIED LIFE SCIENCES↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry↗

Low Frequency Cable Dual Shield Penetration Using Complete Transfer Immittance Model

This report discusses low frequency coupling and subsequent penetration of a dual shield cable using a transfer immittance model with reciprocal sources. Configurations include: 1) where the cable is above a ground plane and shorted at both ends, 2) a monopole arrangement where it is shorted at one end and open at the other end, and 3) a monopole arrangement where the open end is loaded by a disc. The open circuit voltage within the cable is estimated for each case.

42 ENGINEERING↗

Low-frequency Raman active modes of twisted bilayer MoS 2

Abstract We study the low-frequency Raman active modes of twisted bilayer MoS 2 for several twist angles using a force-field approach and a parametrized bond polarizability model. We show that twist angles near high-symmetry stacking configurations exhibit stacking frustration that leads to significant buckling of the moiré superlattice. We find that atomic relaxation due to the twist is of prime importance. The periodic displacement of the Mo atoms shows the realization of a soliton network, and in turn, leads to the emergence of a number of frequency modes not seen in the high-symmetry stacking systems. Some of the modes are only seen in the XZ Raman polarization setup while others are seen in the XY setup. The symmetry of the normal modes, and how this affects the Raman tensors is examined in detail.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Perturbative analysis of low-frequency instabilities in high-field ST40 experiments

Abstract Linear and nonlinear perturbative analyses of low-frequency instabilities are presented for ST40 spherical torus high field plasmas, with simultaneous neutral beam heating due to two tangential sources at 25 keV and 55 keV. Initial plasma profiles on which the TRANSP and NUBEAM codes were based were obtained using an integrated analysis of several diagnostics including line-of-sight integrated and volume average measurements, as well as limited profile information from a charge-exchange-recombination spectrometer. Magnetohydrodynamics (MHD) analysis using the NOVA/NOVA-K codes suggests that the modes in the experiments are core-localized n = 1 eigenmodes with mixed acoustic and electromagnetic Alfvénic polarization. The global transport combined with the perturbative mode analysis indicates that there is greater tendency for bursty chirping response as the level of background micro-turbulence decreases in time and those predictions are shown to be consistent with the experimental data. This finding is interpreted in terms of the suppression of coherent phase-space structures that support chirping when the resonant fast ion dynamics is dominated by frequent stochastic, orbit-decorrelating events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-frequency noise in β-(Al x Ga1 −x )2O3 Schottky barrier diodes

We report on the low-frequency electronic noise in β-(AlxGa1−x)2O3 Schottky barrier diodes. The noise spectral density reveals 1/f dependence, characteristic of the flicker noise, with superimposed Lorentzian bulges at the intermediate current levels (f is the frequency). The normalized noise spectral density in such diodes was determined to be on the order of 10−12 cm2/Hz (f = 10 Hz) at 1 A/cm2 current density. At the intermediate current regime, we observed the random telegraph signal noise, correlated with the appearance of Lorentzian bulges in the noise spectrum. The random telegraph signal noise was attributed to the defects near the Schottky barrier. The defects can affect the local electric field and the potential barrier and, correspondingly, impact the electric current. The obtained results help in understanding the noise in Schottky barrier diodes made of ultra-wide bandgap semiconductors and can be used for the material and device quality assessment.

Physics↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗

Temperature Dependence of Low‐Frequency Noise Characteristics of NiO x /β‐Ga 2 O 3 p–n Heterojunction Diodes

Temperature dependence of the low-frequency electronic noise in NiO x /β-Ga 2 O 3 p–n heterojunction diodes is reported. The noise spectral density is of the 1/f-type near room temperature but shows signatures of Lorentzian components at elevated temperatures and at higher current levels (f is the frequency). It is observed that there is an intriguing non-monotonic dependence of the noise on temperature near T = 380 K. The Raman spectroscopy of the device structure suggests material changes, which results in reduced noise above this temperature. The normalized noise spectral density in such diodes is determined to be on the order of 10 −14 cm 2 Hz −1 (f = 10 Hz) at 0.1 A cm −2 current density. In terms of the noise level, NiO x /β-Ga 2 O 3 p–n diodes perform excellently for new technology and occupy an intermediate position among devices of various designs implemented with different ultra-wide-bandgap semiconductors. The obtained results are important for understanding the electronic properties of NiO x /β-Ga 2 O 3 heterojunctions and contribute to the development of noise spectroscopy as the quality assessment tool for new electronic materials and device technologies.

1/f noise↗

Improved detection of low-frequency within-host variants from deep sequencing: A case study with human papillomavirus

Abstract High-coverage sequencing allows the study of variants occurring at low frequencies within samples, but is susceptible to false-positives caused by sequencing error. Ion Torrent has a very low single nucleotide variant (SNV) error rate and has been employed for the majority of human papillomavirus (HPV) whole genome sequences. However, benchmarking of intrahost SNVs (iSNVs) has been challenging, partly due to limitations imposed by the HPV life cycle. We address this problem by deep sequencing three replicates for each of 31 samples of HPV type 18 (HPV18). Errors, defined as iSNVs observed in only one of three replicates, are dominated by C→T (G→A) changes, independently of trinucleotide context. True iSNVs, defined as those observed in all three replicates, instead show a more diverse SNV type distribution, with particularly elevated C→T rates in CCG context (CCG→CTG; CGG→CAG) and C→A rates in ACG context (ACG→AAG; CGT→CTT). Characterization of true iSNVs allowed us to develop two methods for detecting true variants: (1) VCFgenie, a dynamic binomial filtering tool which uses each variant’s allele count and coverage instead of fixed frequency cut-offs; and (2) a machine learning binary classifier which trains eXtreme Gradient Boosting models on variant features such as quality and trinucleotide context. Each approach outperforms fixed-cut-off filtering of iSNVs, and performance is enhanced when both are used together. Our results provide improved methods for identifying true iSNVs in within-host applications across sequencing platforms, specifically using HPV18 as a case study.

Virology↗

Effects of low-frequency voltage on nonlinear standing wave excitation, plasma uniformity, and ion dynamics in dual-frequency asymmetric capacitive discharges

Abstract It is known that in very-high-frequency (VHF) capacitively coupled plasmas, the higher harmonics generated by nonlinear sheath motion can enhance the standing wave effect (SWE), which can lead to center-peaked plasma density profiles. In this work, an improved nonlinear electromagnetic model incorporating a transmission line model, an electron momentum balance model, a bulk plasma model, a collisionless nonlinear numerical sheath model, and an ion Monte-Carlo collision (MCC) model is developed to study the effects of low-frequency (LF) voltage V L on the nonlinear standing wave excitation, plasma uniformity, and ion energy and angular distribution functions (IEDFs and IADFs) in dual-frequency (DF) asymmetric capacitive argon discharges at relatively low pressure of 3 Pa. The plasma diffusion in the radial direction and ion dynamics within the LF oscillating sheath are self-consistently considered. The LF voltage V L at 2 MHz varies from 0 to 700 V while the HF voltage V H at 60 MHz is fixed at 100 V. Simulation results indicate that without the addition of an LF source (i.e. V L = 0 V), there are a considerable number of high-order harmonics with short wavelengths, leading to significant SWE and central peak in the radial plasma density profile. Nevertheless, the high-order harmonic excitations tend to be weakened and merely occur around the phase of the full LF sheath collapse due to a shorter characteristic damping time of the surface waves as V L increases. This, combined with increased surface wavelengths of both the driving frequency and the higher harmonics at a higher V L , leads to suppressed standing waves and improved plasma uniformity. Meanwhile, the simulations show that both the low and the high energy peaks of IEDF move towards higher energies, and the energy peak separation width ΔEbecomes wider with the increase of V L . The IEDF at the radial center of the powered electrode exhibits a broader ΔEthan that at the edge. For the IADF, an increased V L results in more ions incident on the electrode with a smaller deflection angle. Because of a thinner sheath and a higher sheath voltage at the electrode center, the peak value of IADF at the electrode center is greater than that at the edge.

Physics↗

Quantum metrology of low frequency electromagnetic modes with frequency upconverters

We describe the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) (≲300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band (~ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. The RQU can operate as a quantum-limited op-amp, or use protocols from optomechanics to implement non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. Furthermore, these protocols enable experiments using dc-VHF electromagnetic modes as quantum sensors.

Kuenstner, Stephen E.↗

Polarization and properties of low-frequency waves in warm magnetized two-fluid plasma

This paper presents the derivation of a general wave dispersion relation for warm magnetized plasma under the two-fluid formalism. The discussion is quite general except for the assumption of low frequency and slow phase speed, for which the displacement current is negligible, under the implicit assumption that the plasma is sufficiently dense to satisfy the condition ωpe>ωce, where ωpe and ωce denote the plasma oscillation frequency and electron gyro frequency, respectively. The present discussion does not invoke charge neutrality associated with the fluctuations although it is implicitly satisfied. The resulting dispersion relation that includes the fluid thermal effects shows that there are three eigen modes, which include those corresponding to ideal MHD, namely, fast, slow, and kinetic Alfvén waves, as well as higher-frequency modes including the ion and electron cyclotron and lower-hybrid resonances. The fluid effects in the ideal MHD wave branches are influenced by the finite Larmor radius scales, and when the wave number in the cross field direction is comparable to these values, the fluid effects become significant. It is found that the Larmor radius should be interpreted in the sense as ion-acoustic gyro-radius instead of ion thermal gyro radius only. That is, it is found that the electrons also contribute to the non-ideal effect associated with the kinetic Alfvén wave. A comprehensive explanation of the polarization of each mode is also presented. The present findings indicate that the polarity may change its sign only for the kinetic Alfvén mode branch and that such a transition is based on the propagation angle. When such a change does take place, it is found that the kinetic Alfvén wave transits to an ion-acoustic mode. For each branch, it is also found that the electric field along the ambient magnetic field is purely transverse.

Physics↗