Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Variable speed pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

An electrified boom actuation system with energy regeneration capability driven by a novel electro-hydraulic unit

This paper presents a novel electrified solution for linear actuation systems, which has undergone a successful in-vehicle demonstration, marking a significant advancement in this field. Aligned with the growing trend towards electrification, this solution holds promise for a wide range of off-road applications. The showcased electrohydraulic actuation architecture enables efficient four-quadrant operation and incorporates energy recovery capabilities. At the core of the system lies a distinctive electro-hydraulic unit, integrating a fixed hydraulic pump and a variable-speed electric motor into a compact and powerful entity. A specialized hydraulic system is designed to efficiently transform electrical energy from the electro-hydraulic unit into boom cylinder actuation. The sizing of the system is determined by the boom operation of a commercial compact loader. The maximum power output of the electro-hydraulic system is approximately 15 kW. The components of the proposed system are integrated into the reference vehicle, and comprehensive performance tests are conducted. The results of the tests performed on the vehicle with the boom lifting and lowering cycle indicate an overall system efficiency of 60%. The electrified solution consumes only about one-third of the energy used by the conventional boom actuation system on the reference machine, while exhibiting energy savings exceeding 75% during specific work phases. The energy savings come mainly from energy regeneration and minimal loss from throttling through the specialized hydraulic circuit design. Finally, the successful demonstration on the reference vehicle underscores the practicality and effectiveness of the proposed electrified solution in current mobile hydraulic applications

42 ENGINEERING↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Irrigation system

A gravity irrigation system includes a distribution piping having apertures to distribute water to a field, and a valve located upstream of the distribution piping. The valve limits a pressure of the water being delivered to the distribution piping. The system also includes a sump to receive the water at a lowest elevation of the field, a depth sensor disposed within the sump, and a return pump disposed at least partially within the sump to move the water to an elevated portion of the field. The system also includes a motor to drive the return pump, and a power source coupled to a variable frequency drive that powers the motor and controls a motor speed proportionately to an indication of the depth sensor. The system also includes a transfer piping to bring the water from the return pump to a check valve and to the distribution piping.

Henry, Christopher G.↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VALVE TIMING AND AREA PROFILE SELECTION FOR HYDRAULIC PUMPS AND MOTORS

A significant amount of research has been conducted to select valve timing and area profiles that create efficient and quiet hydraulic pumps and motors. Numerous active valve architectures have been modeled and optimized, but the rationale for the final solution is often unclear. The solution is usually highly dependent on the modeled valve geometry constraints and the duty cycle of the pump or motor for which the valve was optimized. This paper first presents an ideal valve area profile and what compromises are made to design for a working pressure and speed range. The ideal valve area profile is resolved using a piston-cylinder model with a pressure dependent bulk modulus and variable valve openings. The piston-cylinder is first modeled as a pump with passive (check) valves and a specified pressure drop across the valves to determine the ideal area profile. A generalization of the ideal timing is demonstrated for positive pressure differential and positive rotation direction, also known as the first quadrant. The effects on valve timing when varying pressure are shown for the first quadrant, but the trends can be extrapolated for all quadrants of operation. The ideal valve profile is implemented as fixed valve timing, meaning the valve area is only a function of the timing angle, in a pump-motor. The pump-motor is simulated in one rotation direction through a pressure range. Performance is high in pumping operation, but when the pressure differential is reversed, cylinder pressure spikes ensue. Two strategies to modify an ideal valve area profile are presented: timing grooves and a pressure shifted valve timing. Timing grooves reduce pressure spikes and cavitation in the cylinder but generally increase throttling losses. A pressure shifted valve timing has lower throttling energy losses, making it the favored solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

Cold Climate Heat Pump Evaluation

The use of heat pumps in cold and very cold climates increased by 63% between 2009 and 2015 [1, 2]. This can be attributed to development of heat pumps with higher heating capacity at lower temperatures and increased efficiency. A primary technology driving this trend is the use of variable-speed compressors, which come with an increase in the level of controls in the equipment. Most units with variable-speed compressors also include electronic expansion valves and variable-speed indoor (ID) and outdoor (OD) fans. With the increased complexity of these systems, developing a test procedure that is representative of typical performance and not too burdensome on manufacturers presents a difficult challenge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗