Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Vapor Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The vapor pressures of solid and liquid ozone

Vapor pressures of solid and liquid ozone have been measured over a temperature range 87 to below 66 K. The experiment was performed under flow conditions, and the gas was analyzed by a precision mass spectrometer system. In the range of solid ozone two forms, supercooled and crystalline ozone, were found. A least-square fit of the data for crystalline ozone resulted in the equation log P(torr) = A + B/T, where A = 10.460 and B = -1021.6. The estimated uncertainty of the data is + or - 1.0 percent. A triple-point temperature of 79.6 + or - 0.3 K was found where supercooled and crystalline ozone data intersect.

Hanson, David

Evaluation of Vapor Pressure and Ultra-High Vacuum Tribological Properties of Ionic Liquids (2) Mixtures and Additives

Ionic liquids are salts, many of which are typically viscous fluids at room temperature. The fluids are characterized by negligible vapor pressures under ambient conditions. These properties have led us to study the effectiveness of ionic liquids containing both organic cations and anions for use as space lubricants. In the previous paper we have measured the vapor pressure and some tribological properties of two distinct ionic liquids under simulated space conditions. In this paper we will present vapor pressure measurements for two new ionic liquids and friction coefficient data for boundary lubrication conditions in a spiral orbit tribometer using stainless steel tribocouples. In addition we present the first tribological data on mixed ionic liquids and an ionic liquid additive. Post mortem infrared and Raman analysis of the balls and races indicates the major degradation pathway for these two organic ionic liquids is similar to those of other carbon based lubricants, i.e. deterioration of the organic structure into amorphous graphitic carbon. The coefficients of friction and lifetimes of these lubricants are comparable to or exceed these properties for several commonly used space oils.

Morales, Wilfredo

Methods of Measuring Vapor Pressures of Lubricants With Their Additives Using TGA and/or Microbalances

The life of a space system may be critically dependent on the lubrication of some of its moving parts. The vapor pressure, the quantity of the available lubricant, the temperature and the exhaust venting conductance passage are important considerations in the selection and application of a lubricant. In addition, the oil additives employed to provide certain properties of low friction, surface tension, antioxidant and load bearing characteristics, are also very important and need to be known with regard to their amounts and vapor pressures. This paper reports on the measurements and analyses carried out to obtain those parameters for two often employed lubricants, the Apiezon(TM)-C and the Krytox(TM) AB. The measurements were made employing an electronic microbalance and a thermogravimetric analyzer (TGA) modified to operate in a vacuum. The results have been compared to other data on these oils when available. The identification of the mass fractions of the additives in the oil and their vapor pressures as a function of the temperature were carried out. These may be used to estimate the lubricant life given its quantity and the system vent exhaust conductance. It was found that the Apiezon(TM)-C has three main components with different rates of evaporation while the Krytox(TM) did not indicate any measurable additive.

Scialdone, John J.

Evaporation rate and vapor pressure of selected polymeric lubricating oils.

A recently developed ultrahigh-vacuum quartz spring mass sorption microbalance has been utilized to measure the evaporation rates of several low-volatility polymeric lubricating oils at various temperatures. The evaporation rates are used to calculate the vapor pressures by the Langmuir equation. A method is presented to accurately estimate extended temperature range evaporation rate and vapor pressure data for polymeric oils, incorporating appropriate corrections for the increases in molecular weight and the change in volatility of the progressively evaporating polymer fractions. The logarithms of the calculated data appear to follow linear relationships within the test temperature ranges, when plotted versus 1000/T. These functions and the observed effusion characteristics of the fluids on progressive volatilization are useful in estimating evaporation rate and vapor pressure changes on evaporative depletion.

Gardos, M. N.

Effusion Cell Measurements of the Vapor Pressure of Cobalt at Temperatures up to 2000K; Comparisons with Iron and Nickel

It has become increasingly clear over the past decade that high temperature processes played important roles in the Primitive Solar Nebula. Unfortunately, basic data, such as the vapor pressures of Fe, Ni, Co or SiO have not been measured over the appropriate temperature range (near T approx. 2000K), but must be extrapolated from lower temperature measurements often made more than 50 years ago. The extrapolation of the available data to higher temperatures can be quite complex (e.g., see [1] for SiO vapor pressures) and can depend on other factors such as the oxygen fugacity or the presence of hydrogen gas not accounted for in the original measurements. Moreover, modern technology has made possible more accurate measurements of such quantities over a wider temperature range. We have acquired a commercial Thermo-Cahn Thermogravimetric system capable of vacuum operation to 1700C and measurement of a 10g change in sample mass using up to a 100g sample, with microgram accuracy. With this new system we have initiated a series of basic vapor pressure measurements on simple metals such as Fe[2] and Ni[3] with the intention to extend such measurements to more complex systems once we gain sufficient experience.

Nuth, J. A.

The effect of relative humidity and temperature on the response of stomatal conductance to vapor pressure deficit in tropical trees

Understanding how leaf gas exchange responds to changes in vapor pressure deficit (VPD) is key to predicting tropical forest resilience to climate change. Stomata regulate leaf water and CO2 diffusion, and respond to changes in temperature and relative humidity (RH), two drivers of VPD. At high temperatures, the cuticular pathway may also become significant and participate in the overall leaf conductance. Here, we measured gas exchange under light and dark conditions to investigate the stomatal and cuticular responses to temperature and RH on detached branches in five tropical tree species. Leaf conductance in the dark, when stomata are essentially closed, was not markedly impacted by temperature and RH, suggesting a minimal response of the cuticular pathway to these conditions. We compared six steady-state conductance models incorporating different effects of photosynthesis and evaporative demand on stomatal control. All models performed well (residual standard deviation, σ, < 0.025 mol m-2 s-1), but the best-fitting model (σ = 0.017 mol m-2 s-1) used a nonlinear relationship between photosynthesis and stomatal conductance and incorporated RH rather than vapor pressure difference. All models overestimated the steady-state conductance at high RH. Furthermore, leaf conductance immediately increased after a decrease in RH (wrong-way response), but not after an increase in leaf temperature. This suggests that the mechanisms underlying stomatal response to VPD need further investigation. The non-linear coupling between photosynthetic rate and stomatal conductance indicates a sharper physiological response than previously acknowledged.

Lamour, Julien

Measurement of partial vapor pressures of salt mixtures via combined horizontal transpiration and thermogravimetric analysis

A method combining thermogravimetric analysis (TGA) and horizontal transpiration with elemental analysis via inductively coupled plasma mass spectrometry or ion chromatography enabled calculation of partial pressures of individual salts in molten mixtures. TGA quantified total mass loss, while transpiration identified vapor-phase composition. Furthermore, two chloride (NaCl-MgCl 2 , NaCl-MgCl 2 + UCl 3 ) salts and one mixed halide (LiCl-LiF + Li 2 O) salt were analyzed at 750 °C and 550 °C, respectively. NaCl and MgCl 2 vapor pressures were 2.19–2.61 × 10 -4 atm and 2.47–2.48 × 10 -5 atm (dependent upon the identity of the invesitgated mixture); UCl 3 was 1.42 × 10 -7 atm. LiCl and LiF vapor pressures at 550 °C were 1.53 × 10 -6 and 6.32 × 10 -6 atm, respectively. Additionally, the TGA method was validated against values from the literature for unary LiCl and LiF.

36 MATERIALS SCIENCE

Low vapor pressure braze alloys for thermionic energy converters

Preliminary results in the use of some low-vapor-pressure braze alloys are reported; these are binary alloys of refractory metals (Th, Zr, Hf, Ru, Nb, Ir, Mo, Ta, Os, Re, W) with vapor pressures below 0.1 nanotorr at 1500 K or 10 microtorr at 2000 K. The melting point minima or eutectics of the alloys range from 1510 K to above 3000 K. Melting points and surface wetting on a Ta base are given. Results are presented on brazing of Ir, LaB6, Nb, Re, W, and ZrO2 (with 22 wt % Zr) into a Ta base or a Nb-1% Zr base. The results are applicable in electrode screening programs for thermionic cesium diodes.

Bair, V. L.

Accurate determination of the vapor pressure of potassium using optical absorption

The vapor pressure of potassium has been measured in absorption using a CW tunable laser and calibrated against the accurate radiative lifetime of the 4s-4p doublet of potassium. An accurate value of 20,850 + or - 30 cal/mol for the heat of vaporization (from the liquid phase) at the melting point was determined.

Shirinzadeh, B.

Low vapor pressure braze alloys for thermionic energy converters

The evaluation of cesium diode electrode materials called for braze fillers with very low vapor pressures and a wide range of melting points. Binary alloys of low vapor pressure refractory metals were chosen to fill this need. These alloys of Th, Zr, Hf, Ru, Nb, Ir, Mo, Ta, Os, Re, and W have reported melting point minima or eutectics from 1,510 K to above 3,000 K. Preliminary data are compiled on the use of several of these braze alloys. Melting points and surface wetting on a Ta base are given. Results of brazing Ir, LaB6, Nb, Re, W, and Zr-22 wt % ZrO2 materials into Ta and Nb-1% Zr bases are presented. Current braze usage is summarized.

Bair, V. L.