Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Vacuum Vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Minimizing the Electromechanical Stresses in Poloidal Field Coils by Optimizing their Numbers and Locations using FREDA Framework

Poloidal field (PF) and central solenoid (CS) coils play a crucial role in sustaining the equilibrium and preserving the shape of highly confined tokamak plasmas. Ensuring that PF coil current and mechanical stress stay within superconducting and structural limitations is an important check in the design assessment. Minimizing the PF coil currents and mechanical stresses influences reliability, cost, and performance. A free-boundary MHD equilibrium code—FreeGS is employed within the fusion reactor design and assessment (FREDA) whole facility modeling (WFM) framework to construct the plasma equilibrium based on the configuration and currents in the PF coils. Here, we present the capability of the FreeGS code to minimize the currents, forces, and electromagnetic stresses on the PF coils by optimizing their number, sizes, structures, and locations while maintaining an MHD stable plasma configuration with a large confinement factor. The workflow is initialized with a configuration of plasma parameters and coils’ locations from the 0-D tokamak build systems code in the FREDA framework. Then, FreeGS is called to calculate the initial equilibrium at the minimum total current in PF coils. Thereafter, FreeGS’s internal optimizer minimizes the currents and hoop and central forces on the PF coils while maintaining the reference equilibrium. Finally, the input configuration is updated with the optimized parameters for equilibria over the ramp-up phase of a burning-plasma operation. FREDA’s whole facility optimization capability, which includes all magnetic field coil systems, blanket, vacuum vessel (VV), first wall, divertor, etc., is under development and out of the scope for this study.

Hassan, Ehab [ORNL] (ORCID:0000000181060301)↗

Cryogenic pressurized storage with hump-reinforced vacuum jacket

A cryogenic hydrogen storage vessel includes an outer vacuum vessel, a reinforcement ring on the outer vacuum vessel, an inner pressure vessel inside of the outer vacuum vessel, and a vacuum space between the outer vacuum vessel and the inner pressure vessel. One embodiment of the cryogenic hydrogen storage vessel includes an outer vacuum vessel; a hump-shaped reinforcement ring on the outer vacuum vessel, the hump-shaped reinforcement ring including an external hump portion that protrudes from the hump-shaped reinforcement ring and an internal recess in the hump-shaped reinforcement ring; an inner pressure vessel inside of the outer vacuum vessel, a vacuum space between the outer vacuum vessel and the inner pressure vessel, and a composite support ring in the vacuum space extending from the hump-shaped reinforcement ring on the outer vacuum vessel to the inner pressure vessel, the composite support ring nested in the recess in the hump-shaped reinforcement ring.

Aceves, Salvador M.↗

Precision measurement of the magnetic field in run 1 of the g-2 experiment

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

Vacuum commissioning and operation result after the KSTAR PFC upgrade

The first vacuum commissioning after the installation of new tungsten mono-block cassette divertor has been successfully conducted in KSTAR. The tungsten divertor has been installed in the lower divertor region to handle the high divertor heat loads up to 10 MW/m 2 . On the one hand, the plasma facing components except for the tungsten divertor in the KSTAR vacuum vessel still consists of graphite tiles. Thus, it was much more challenging to maintain high-quality vacuum condition mainly because of various possible impurity sources inside the vessel compared with previous experiment campaigns. In this paper, the detailed procedure for securing vacuum condition of the KSTAR tokamak after the installation of the new tungsten divertor is presented. The vacuum condition is also examined regarding the plasma start-up and the long-pulse high-performance quality.

KSTAR↗

AUP First Pre-Series Cryo-Assembly Design Production and Test Overview

New high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) have been built and tested as part of the high-luminosity upgrade of the Large Hadron Collider (HL-LHC). These new quadrupole magnets are based on Nb3Sn superconducting technology. The US Accelerator Upgrade Project (US-AUP) is producing the Q1 and Q3 Cryo-Assemblies: a pair of ~5 m long magnet structures installed in a stainless-steel helium vessel (Cold Mass) and surrounded by cryostat shields, piping, and a vacuum vessel. In conclusion, this paper gives an overview of the design, production, and the results of the horizontal test of the first pre-series Q1/Q3 Cryo-Assembly.

43 PARTICLE ACCELERATORS↗

AUP first Pre-series Cold Mass Installation into the Cryostat

For the Hi-Lumi LHC Upgrade (HL-LHC) new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP) ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested and delivered to CERN. The first of the LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during the fall of 2022 and spring 2023. We will present the integration work of the Cold Mass assembly into the Cryostat Kit provided by CERN. Each Cold Mass contains two trained MQXFA magnets of ~ 5 m length installed in a stainless-steel helium pressure vessel. The Cold Mass will be surrounded by cryostat shields, piping, and vacuum vessel. We will discuss the metrology survey results and present the LQXFA measurements prior testing at the Fermilab Magnet Test facility and lessons learned.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of transient CHI startup using a floating biased electrode configuration

Abstract Results from the successful solenoid-free plasma startup using the method of transient coaxial helicity injection (transient CHI) in the QUEST spherical tokamak (ST) are reported. Unlike previous applications of CHI on HIT-II and on NSTX which required two toroidal insulating breaks to the vacuum vessel, QUEST uses a first of its kind, floating single biased electrode configuration, which does not use such a vacuum break. Instead, the CHI electrode is simply insulated from the outer lower divertor plate support structure. This configuration is much more suitable for implementation in a fusion reactor than the previous configurations. Transient CHI generated toroidal currents of 135 kA were obtained. The toroidal current during the formation of a closed flux configuration was over 50 kA. These results bode well for the application of transient CHI in a new generation of compact high-field STs and tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Improvements to the High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (CHI) is a promising candidate for solenoid-free plasma current start-up in a low-aspect-ratio tokamak in support of developing fully non-inductive scenarios. The aim of the transient CHI research on QUEST is to develop a reactor-relevant CHI design. On QUEST, a CHI discharge is initiated by driving current along magnetic field lines that connect an electrically insulated electrode plate (which is referred to as a bias electrode) to a vessel component at the bottom region of the spherical tokamak. In the first application of CHI on QUEST, the electrically insulated electrode plate was biased with respect to the outer vessel in a configuration referred to as low-field-side (LFS) injection. To maintain a narrow injector flux footprint width throughout the discharge, QUEST is now developing a high-field-side (HFS) injection configuration, in which the electrically insulated electrode plate is biased with respect to the inner vessel components. Through the implementation of a CHI-dedicated gas injection system, studies in the HFS injection configuration have now demonstrated good magnetic flux evolution into the vacuum vessel. Toroidal currents up to 43 kA have been achieved, and the generated current has increased in proportion to the magnetic flux connecting the electrodes. Finally, these results which show agreement with the CHI-scaling suggest that much higher levels of toroidal current can be generated on QUEST in an optimized CHI system in which the magnetic flux connecting the CHI electrodes is further increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A MINi Powder INjector (MINPIN) for the SMART tokamak

Here, this article presents the design and performance characterization of a MINi Powder INjector (MINPIN) developed for boron wall conditioning (boronization) in the SMall Aspect Ratio Tokamak (SMART) at the University of Seville, Spain. SMART studies positive and negative triangularity plasmas within the low aspect ratio range of 1.4 < R/a < 3, with a major radius (R) of 0.40–0.60 m and a minor radius (a) of 0.20–0.33 m. MINPIN, in design, will gravitationally deliver boron (B) powder into the plasma, which ablates and transports the injected material. Mounted on the top of the vessel, the MINPIN will drop controlled amounts of powder using a piezoelectric blade driven by a signal generator that vibrates at a set frequency. The B will then be deposited in a layer on SMART’s stainless steel vacuum vessel walls, and this boronization process reduces the influx of intrinsic wall impurities, such as oxygen, carbon, nitrogen, and iron, which radiate power and cool the plasma. In the laboratory, we calibrated the drop rate for 1–10 mg/s, which will enable controlled boronization coating while achieving efficient powder ablation. We propose MINPIN’s operational scenarios based on the calibrated drop rate and estimated drop duration, assuming the distance from MINPIN to SMART’s plasmas.

Boron powder↗

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗

Boundary condition effects on runaway electron mitigation coil modeling for the SPARC and DIII-D tokamaks

Abstract Extended-MHD modeling of planned Runaway Electron Mitigation Coils (REMC) for SPARC and DIII-D is performed with the NIMROD code. A coil has been designed for each machine, with the two differing in shape and location, but both having n = 1 symmetry (with n the toroidal mode number). Compared to previous modeling efforts, three improvements are made to the simulations boundary conditions. First a resistive wall model is used in place of an ideal wall. Second, the ThinCurr code is used to compute the time-dependent 3D fields used as magnetic boundary conditions for the simulations. Third, the simulation boundary is moved from the first-wall location to the Vacuum Vessel (VV), which extends the boundary past the location of the internal REMC. To remove the 3D coil from the simulation domain, an equivalent set of 3D fields is calculated at the VV boundary that produce approximately the same field distribution at the last closed flux surface assuming vacuum between the two. Each of these three boundary condition improvements leads to an improvement in the predicted performance of the REMC for both machines. The resistive wall alone primarily effects the resonance of the coil with the plasma after the TQ, affecting the q-profile evolution in the SPARC modeling, and allowing the applied spectrum to be modified in response to the plasma in the DIII-D modeling. The movement of the simulation boundary has the most significant effect on the RE confinement overall, including in the early stages, particularly for a DIII-D inner wall limited equilibrium, where the RE loss fraction increases from 90% to > 99%, with SPARC RE losses also occurring much earlier when the boundary is placed at the VV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bus Design for the Poloidal Field Coils of the NSTX-Upgrade Fusion Device

The National Spherical Torus eXperiment (NSTX) has undergone a major upgrade to NSTX-U at Princeton Plasma Physics Laboratory (PPPL). NSTX upgrade (NSTX-U) will double the toroidal field, plasma current, and neutral beam injection heating power, as well as significantly increase the pulse duration. NSTX-U uses three poloidal field (PF) coils at the vessel top and three at the bottom near the divertor areas to control the local plasma shape there. These shaping coils operate at a maximum terminal voltage of 2 kV, corresponding to a maximum current about 20 kA. To supply the power to the PF coils, hard copper bus bars are typically used near the vacuum vessel, while water cooled flexible cables are used away from the vessel. The detailed design of the hard copper bus bars will be covered in this article. During operation, these hard bus bars are subject to high electromagnetic (EM) forces, thermal displacement loads, as well as plasma halo loads due to disruption. The EM, thermal, and structural analysis were performed, and the results revealed that, with the worst loads combined, the new design meets the NSTX-U thermal, structural, and fatigue cycle requirements. Finally, the manufacturing and installation process of the bus work will be discussed at the end of this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutronics Analysis of Shielding Material Alternative to Tungsten Carbide in the FESS-FNSF Facility

Neutron transport calculations have been performed on advanced shielding materials. Metal hydrides and borohydrides were evaluated to find an alternative to tungsten carbide (WC), which is used in the in-vessel components. The study was conducted using a 22.5° sector and a detailed 360° geometry of the Fusion Energy System Studies-Fusion Nuclear Science Facility (FESS-FNSF) using OpenMC and FENDL-3.2b nuclear data library. Here, the neutronics analysis in this article was concentrated on calculating total nuclear (neutron and photon) heating at the magnet and the radiation damage of the inboard vacuum vessel (IBVV). For example, yttrium hydride (YH 2 ) and vanadium hydride (VH 2 ) showed lower radiation damage values compared to WC and other metals. Whereas alternative shielding materials did not show a significant change in the magnet nuclear heating.

36 MATERIALS SCIENCE↗

DESIGN ISSUES AND QUALIFICATION OF HYDROFORMED DOUBLE WALLED EXPANSION JOINTS IN VACUUM SERVICE

The Vacuum Auxiliary System for ITER is devoted to pumping out, venting, and purging the vacuum volumes of the tokamak. Over 5000 clients including the cryostat and vacuum vessel, at 8500 m3 and 1400 m3 respectively, are serviced by approximately 150 pumping stations through 6 km of pipework. The piping and functions provided to the clients include component operation, routing of potentially tritiated gases, and timely leak localization. Expansion joints are used to reduce loadings on pumps and piping stresses but also to qualify in-line components having low allowable design loads. The ITER project utilizes vacuum valves that are not designed to withstand typical piping system loadings and require detailed design and evaluation. Loading scenarios prescribed by governing system specifications must be considered. To maintain allowable design loads for components and to keep piping stresses below code requirements, double walled hydroformed expansion joints have been employed in the design. These are not standard items and require custom fabrication. Installation space constraints and adjacent pipe support attachment location availability at ITER limit standard expansion joint installation guidelines provided by the Expasion Joint Manufacturers Association (EJMA). Careful consideration must be given to the analysis model to ensure proper function and life expectancy of the component. These considerations include accurate accounting of thrust forces, thermal movements, seismic accelerations, equipment and building differential displacements. In addition to displacements, the process internal, external, and interspace pressures affect the qualification and selection of the double walled expansion joints. The calculation results shall confirm that deflections, forces, and moments are reasonable for the size and type required for the system’s demands as evaluated against the manufacturer’s design.

Clark, Forrest [ORNL] (ORCID:0009000678106843)↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗