Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reconciling Contrasting Relationships Between Relative Dispersion and Volume-Mean Radius of Cloud Droplet Size Distributions

Cloud droplet spectral relative dispersion is critical to parameterizations of cloud radiative properties, warm-rain initiation, and aerosol-cloud interactions in models; however, there is no consistent relationship between relative dispersion and volume-mean radius in literature, which hinders improving relative dispersion parameterization and calls for physical explanation. Here we show, by analyzing aircraft observations of cumulus clouds during Routine AAF [Atmospheric Radiation Measurement (ARM) Aerial Facility] Clouds with Low Optical Water Depths (CLOWD) Optical Radiative Observations, that the correlation between relative dispersion and volume-mean radius changes from positive to negative as volume-mean radius increases. With the new observation, we postulate that the sign of the correlation is determined by whether or not condensation (evaporation) occurs simultaneously with significant new activation (deactivation). The hypothesis is validated by simulations of both an adiabatic cloud parcel model and a parcel model accounting for entrainment-mixing. A new quantity, first bin strength, is introduced to quantify this new observation. Theoretical analysis of truncated gamma and modified gamma size distributions further supports the hypothesis and reconciles the contrasting relationships between relative dispersion and volume-mean radius, including the results in polluted fog observations. The results could shed new light on the so-called “twilight zone” between cloudy and cloud-free air, which in turn affects evaluation of aerosol-cloud interactions and retrieval of aerosol optical depth.

Lu, Chunsong↗

SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

60 APPLIED LIFE SCIENCES↗

SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

60 APPLIED LIFE SCIENCES↗

Comparison of Statistically Modeled Contaminated Soil Volume Estimates and Actual Excavation Volumes at the Maywood FUSRAP Site - 13555

As part of the ongoing remediation process at the Maywood Formerly Utilized Sites Remedial Action Program (FUSRAP) properties, Argonne National Laboratory (Argonne) assisted the U.S. Army Corps of Engineers (USACE) New York District by providing contaminated soil volume estimates for the main site area, much of which is fully or partially remediated. As part of the volume estimation process, an initial conceptual site model (ICSM) was prepared for the entire site that captured existing information (with the exception of soil sampling results) pertinent to the possible location of surface and subsurface contamination above cleanup requirements. This ICSM was based on historical anecdotal information, aerial photographs, and the logs from several hundred soil cores that identified the depth of fill material and the depth to bedrock under the site. Specialized geostatistical software developed by Argonne was used to update the ICSM with historical sampling results and down-hole gamma survey information for hundreds of soil core locations. The updating process yielded both a best guess estimate of contamination volumes and a conservative upper bound on the volume estimate that reflected the estimate's uncertainty. Comparison of model results to actual removed soil volumes was conducted on a parcel-by-parcel basis. Where sampling data density was adequate, the actual volume matched the model's average or best guess results. Where contamination was un-characterized and unknown to the model, the actual volume exceeded the model's conservative estimate. Factors affecting volume estimation were identified to assist in planning further excavations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of the Post-Lumpectomy Target Volume Versus the Use of Pre-Lumpectomy Tumor Volume for Early-Stage Breast Cancer: Implications for the Future

Purpose: Three-dimensional conformal accelerated partial breast irradiation (APBI-3D-CRT) is commonly associated with the treatment of large amounts of normal breast tissue. We hypothesized that a planning tumor volume (PTV) generation based on an expansion of the pre-lumpectomy (pre-LPC) intact tumor volume would result in smaller volumes of irradiated normal breast tissue compared with using a PTV based on the post-lumpectomy cavity (post-LPC). Use of PTVs based on the pre-LPC might also result in greater patient eligibility for APBI-3D-CRT. Methods and Materials: Forty-one early-stage breast cancers were analyzed. Preoperative imaging was used to determine a pre-LPC tumor volume. PTVs were developed in the pre- and post-LPC settings as per National Surgical Breast and Bowel Project (NSABP)-B39 guidelines. The pre- and post-LPC PTV volumes were compared and eligibility for APBI-3D-CRT determined using NSABP-B39 criteria. Results: The post-LPC PTV exceeded the pre-LPC PTV in all cases. The median volume for the pre- and post-LPC PTVs were 93 cm{sup 3} (range, 24-570 cm{sup 3}) and 250 cm{sup 3} (range, 45-879 cm{sup 3}), respectively, p <0.001. The difference between pre- and post-LPC PTVs represented a median of 165 cc (range, 21-482 cc) or 16% (range, 3%-42%) of the whole breast volume. Three of 41 vs. 13 of 41 cases were ineligible for APBI-3D-CRT when using the pre- and post-LPC PTVs, respectively. Conclusion: PTVs based on pre-LPC tumor expansion are likely associated with reduced amounts of irradiated normal breast tissue compared with post-LPC PTVs, possibly leading to greater patient eligibility for APBI-3D-CRT. These findings support future investigation as to the feasibility of neoadjuvant APBI-3D-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exponential reduction of finite volume effects with twisted boundary conditions

Here, flavor-twisted boundary conditions can be used for exponential reduction of finite volume artifacts in flavor-averaged observables in lattice QCD calculations with S U ( N f ) light quark flavor symmetry. Finite volume artifact reduction arises from destructive interference effects in a manner closely related to the phase averaging which leads to large N c volume independence. With a specific choice of flavor-twisted boundary conditions, finite volume artifacts for flavor-singlet observables in a hypercubic spacetime volume are reduced to the size of finite volume artifacts in a spacetime volume with periodic boundary conditions that is four times larger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation of Electrolyte Volume and Electrochemical Performance in Lithium-Ion Pouch Cells with Graphite Anodes and NMC532 Cathodes

The work herein reports on studies aimed at exploring the correlation between electrolyte volume and electrochemical performance of full cell, pouch-cells consisting of graphite/ Li 1.02 Ni 0.50 Mn 0.29 Co 0.19 O 2 (NMC-532) as the electrodes and 1.2 M LiPF 6 in ethylene carbonate:ethylmethyl carbonate (EC:EMC) as the electrolyte. In addition, it is demonstrated that a minimum electrolyte volume factor of 1.9 times the total pore volume of cell components (cathode, anode, and separator) is needed for long-term cyclability and low impedance. Less electrolyte results in an increase of the measured Ohmic resistances. Increased resistance ratios for charge transfer and passivation layers at cathode, relative to initial values, were 1.5 2.0 after 100 cycles. At the cathode, the resistance from charge transfer was 2-3 times higher than for passivation layers. Lastly, differential voltage analysis showed that anodes were less delithiated after discharging as the cells were cycled.

25 ENERGY STORAGE↗

Fermi surface volume of interacting systems

Three Fermion sumrules for interacting systems are derived at T=0, involving the number expectation N-bar (μ), canonical chemical potentials μ(m), a logarithmic time derivative of the Greens function γ{sub k-vector σ} and the static Greens function. In essence we establish at zero temperature the sumrules linking: N-bar (μ)↔∑{sub m}Θ(μ−μ(m))↔∑{sub k-vector ,σ}Θ(γ{sub k-vector σ})↔∑{sub k-vector ,σ}Θ(G{sub σ}( k-vector ,0)). Connecting them across leads to the Luttinger and Ward sumrule, originally proved perturbatively for Fermi liquids. Our sumrules are nonperturbative in character and valid in a considerably broader setting that additionally includes non-canonical Fermions and Tomonaga–Luttinger models. Generalizations are given for singlet-paired superconductors, where one of the sumrules requires a testable assumption of particle–hole symmetry at all couplings. The sumrules are found by requiring a continuous evolution from the Fermi gas, and by assuming a monotonic increase of μ(m) with particle number m. At finite T a pseudo-Fermi surface, accessible to angle resolved photoemission, is defined using the zero crossings of the first frequency moment of a weighted spectral function.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changes in Excision Cavity Volume: Prediction of the Reduction in Absolute Volume During Breast Irradiation

Purpose: The aim of this study was to determine the changes in the excision cavity volume due to the resolution of the surgical effects during the whole breast treatment. Materials and Methods: Seventy-seven patients with early-stage (T1-2 N0) breast cancer treated with breast-conserving therapy were included for this study. All patients underwent a standard planning computed tomography (CT) scan before irradiation treatment. A second CT scan was performed in the week before the start of the boost. Excision cavity volumes were delineated based on the surgical clips and the (surrounding) seroma or hematoma or other surgical changes on both scans by an experienced physician. This resulted in the gross tumor volumes GTV1 and GTV2. Results: The delineated volumes of the GTVs were on average 78.7 cm{sup 3} (range, 1.1-236.0 cm{sup 3}) and 29.7 cm{sup 3} (range, 1.3-123.6 cm{sup 3}) for, respectively, GTV1 and GTV2. The time between the CT scans was on average 37 days (range, 29-74 days). This resulted in a reduction of on average 62%. The absolute reduction per day of the GTV1 was -1.3 cm{sup 3}/day (range, 0.3 to -5.4 cm{sup 3}/day). A linear correlation (correlation coefficient r{sup 2} = 0.81) was observed between the absolute volume of GTV1 and the absolute reduction per day. Conclusion: A significant reduction in excision cavity volume during whole breast irradiation was shown. The observed correlation might be helpful in the decision to perform a second CT scan to adapt the treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging- Versus Computed Tomography-Based Target Volume Delineation of the Glandular Breast Tissue (Clinical Target Volume Breast) in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine MRI and CT for glandular breast tissue (GBT) volume delineation and to assess interobserver variability. Methods and Materials: Fifteen breast cancer patients underwent a planning CT and MRI, consecutively, in the treatment position. Four observers (two radiation oncologists and two radiologists) delineated the GBT according to the CT and separately to the MR images. Volumes, centers of mass, maximum extensions with standard deviations (SD), and interobserver variability were quantified. Observers viewed delineation differences between MRI and CT and delineation differences among observers. Results: In cranio-lateral and cranio-medial directions, GBT volumes were delineated larger using MRI when compared with those delineated with CT. Center of mass on MRI shifted a mean (SD) 17% (4%) into the cranial direction and a mean 3% (4%) into the dorsal direction when compared with that on the planning CT. Only small variations between observers were noted. The GBT volumes were approximately 4% larger on MRI (mean [SD] ratio MRI to CT GBT volumes, 1.04 [0.06]). Findings were concordant with viewed MRI and CT images and contours. Conformity indices were only slightly different; mean conformity index was 77% (3%) for MRI and 79% (4%) for CT. Delineation differences arising from personal preferences remained recognizable irrespective of the imaging modality used. Conclusions: Contoured GBT extends substantially further into the cranio-lateral and cranio-medial directions on MRI when compared with CT. Interobserver variability is comparable for both imaging modalities. Observers should be aware of existing personal delineation preferences. Institutions are recommended to review and discuss target volume delineations and to design supplementary guidelines if necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Gross Tumor Volume and Clinical Target Volume for Preoperative Radiotherapy of Primary Large High-Grade Soft Tissue Sarcoma of the Extremity Among RTOG Sarcoma Radiation Oncologists

Purpose: To evaluate variability in the definition of preoperative radiotherapy gross tumor volume (GTV) and clinical target volume (CTV) delineated by sarcoma radiation oncologists. Methods and Materials: Extremity sarcoma planning CT images along with the corresponding diagnostic MRI from two patients were distributed to 10 Radiation Therapy Oncology Group sarcoma radiation oncologists with instructions to define GTV and CTV using standardized guidelines. The CT data with contours were then returned for central analysis. Contours representing statistically corrected 95% (V95) and 100% (V100) agreement were computed for each structure. Results: For the GTV, the minimum, maximum, mean (SD) volumes (mL) were 674, 798, 752 {+-} 35 for the lower extremity case and 383, 543, 447 {+-} 46 for the upper extremity case. The volume (cc) of the union, V95 and V100 were 882, 761, and 752 for the lower, and 587, 461, and 455 for the upper extremity, respectively. The overall GTV agreement was judged to be almost perfect in both lower and upper extremity cases (kappa = 0.9 [p < 0.0001] and kappa = 0.86 [p < 0.0001]). For the CTV, the minimum, maximum, mean (SD) volumes (mL) were 1145, 1911, 1605 {+-} 211 for the lower extremity case and 637, 1246, 1006 {+-} 180 for the upper extremity case. The volume (cc) of the union, V95, and V100 were 2094, 1609, and 1593 for the lower, and 1533, 1020, and 965 for the upper extremity cases, respectively. The overall CTV agreement was judged to be almost perfect in the lower extremity case (kappa = 0.85 [p < 0.0001]) but only substantial in the upper extremity case (kappa = 0.77 [p < 0.0001]). Conclusions: Almost perfect agreement existed in the GTV of these two representative cases. Tshere was no significant disagreement in the CTV of the lower extremity, but variation in the CTV of upper extremity was seen, perhaps related to the positional differences between the planning CT and the diagnostic MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helium-volume dynamics of Upper Freeport coal powder and lumps

Exposure to 7 MPa of helium at room temperature alters the texture of Upper Freeport coal in a lump form. The differences in texture and porosity between coal powder and lumps may affect the transport and interaction of fluids and coal. In this work, the information about the coal texture and micro- and meso-porosity was obtained via the BET, BJH, and Dubinin–Astakhov analyses. We further investigated the free-fluid-phase volume (free-volume) effects due to helium interaction with the powder and the lumps. During the manometric experiment, helium penetration into the dry coal matrix resulted in slow relaxation of pressure. After exposure of coal to helium, there have been no significant changes of the macroscopic dimensions observed and the relaxation process can be attributed to microscopic ‘free-volume’ effects. Evolution of the sorption–desorption rates indicates that exposure to helium may change the texture and apparent (helium) density of dry coal.

ADSORPTION HEAT↗

SU-E-J-241: Wavelet-Based Temporal Feature Extraction From DCE-MRI to Identify Sub-Volumes of Low Blood Volume in Head-And-Neck Cancer

Purpose: A previous study showed that large sub-volumes of tumor with low blood volume (BV) (poorly perfused) in head-and-neck (HN) cancers are significantly associated with local-regional failure (LRF) after chemoradiation therapy, and could be targeted with intensified radiation doses. This study aimed to develop an automated and scalable model to extract voxel-wise contrast-enhanced temporal features of dynamic contrastenhanced (DCE) MRI in HN cancers for predicting LRF. Methods: Our model development consists of training and testing stages. The training stage includes preprocessing of individual-voxel DCE curves from tumors for intensity normalization and temporal alignment, temporal feature extraction from the curves, feature selection, and training classifiers. For feature extraction, multiresolution Haar discrete wavelet transformation is applied to each DCE curve to capture temporal contrast-enhanced features. The wavelet coefficients as feature vectors are selected. Support vector machine classifiers are trained to classify tumor voxels having either low or high BV, for which a BV threshold of 7.6% is previously established and used as ground truth. The model is tested by a new dataset. The voxel-wise DCE curves for training and testing were from 14 and 8 patients, respectively. A posterior probability map of the low BV class was created to examine the tumor sub-volume classification. Voxel-wise classification accuracy was computed to evaluate performance of the model. Results: Average classification accuracies were 87.2% for training (10-fold crossvalidation) and 82.5% for testing. The lowest and highest accuracies (patient-wise) were 68.7% and 96.4%, respectively. Posterior probability maps of the low BV class showed the sub-volumes extracted by our model similar to ones defined by the BV maps with most misclassifications occurred near the sub-volume boundaries. Conclusion: This model could be valuable to support adaptive clinical trials with further validation. The framework could be extendable and scalable to extract temporal contrastenhanced features of DCE-MRI in other tumors. We would like to acknowledge NIH for funding support: UO1 CA183848.

60 APPLIED LIFE SCIENCES↗

A robust and efficient finite volume method for compressible inviscid and viscous two-phase flows [A robust and efficient finite volume method for compressible viscous two-phase flows]

A robust and efficient density-based finite volume method is developed for solving the six-equation single pressure system of two-phase flows at all speeds on hybrid unstructured grids. Unlike conventional approaches where an expensive exact Riemann solver is normally required for computing numerical fluxes at the two-phase interfaces in addition to AUSM-type fluxes for single-phase interfaces in order to maintain stability and robustness in cases involving interactions of strong pressure and void-fraction discontinuities, a volume-fraction coupling term for the AUSM + -up fluxes is introduced in this work to impart the required robustness without the need of the exact Riemann solver. The resulting method is significantly less expensive in regions where otherwise the Riemann solver would be invoked. A transformation from conservative variables to primitive variables is presented and the primitive variables are then solved in the implicit method in order for the current finite volume method to be able to solve, effectively and efficiently, low Mach number flows in traditional multiphase applications, which otherwise is a great challenge for the standard density-based algorithms. Here, a number of benchmark test cases are presented to assess the performance and robustness of the developed finite volume method for both inviscid and viscous two-phase flow problems. The numerical results indicate that the current density-based method provides an attractive and viable alternative to its pressure-based counterpart for compressible two-phase flows at all speeds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗