Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VO2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oxygen uptake kinetics of constant-load work - Upright vs. supine exercise

Supine and upright positions were used in a comparitive study of the effects of constant load exercise on oxygen uptake (VO2), O2 deficit, steady-state VO2 and VO2 following recovery from constant load work. Ten male subjects (36-40 yr.) performed one submaximal exercise test in the supine and one test in the upright position consisting of 5 min rest and 5 min cycle ergometer exercise at 700 kg/min followed by ten minutes of recovery. It is found that the significant difference in VO2 kinetics during exercise in the upright compared to supine position resulted from changes in oxygen transport and utilization mechanisms rather than changes in mechanical efficiency. To the extent that data measured in the supine position can be used to estimate physiological responses to zero gravity, it is suggested that limitation of systemic O2 consumption may be the result of slow rates of oxygen uptake during transient periods of muscular work. Significant reductions in the rate of steady-state VO2 attainment at submaximal work intensities may produce an onset of muscle fatigue and exhaustion.

Convertino, V. A.↗

Effect of simulated weightlessness on exercise-induced anaerobic threshold

The effect of simulated weightlessness, induced by ten days of continuous bedrest (BR) in the -6 deg head-down position, on the exercise-induced anaerobic threshold (AT) was determined by comparing specific ventilatory and gas-exchange measurements during an incremental ergometer test performed before and after BR. The primary index for determining the exercise-induced AT values of each subject was visual identification of the workrate or oxygen uptake (VO2) at which the ratio of the expired minute ventilation volume (VE) to VO2 exhibited a systematic increase without a concomitant increase in the VE/VCO2 value. Following BR, the mean VO2max of the subjects decreased by 7.0 percent, and the AT decreased from a mean of 1.26 L/min VO2 before BR to 0.95 L/min VO2 after BR. The decrease in AT was manifested by a decrease in both absolute and relative workrates. The change in AT correlated significantly with the change in plasma volume but not with the change in VO2max. The results suggest that the reduction in AT cannot be completely explained by the reduction in VO2, and that the AT decrease is associated with the reduction in intravascular fluid volume.

Convertino, V. A.↗

Cardiopulmonary Responses to Supine Cycling during Short-Arm Centrifugation

The purpose of this study was to investigate cardiopulmonary responses to supine cycling with concomitant +G(sub z) acceleration using the NASA/Ames Human Powered Short-Arm Centrifuge (HPC). Subjects were eight consenting males (32+/-5 yrs, 178+/-5 cm, 86.1+/- 6.2 kg). All subjects completed two maximal exercise tests on the HPC (with and without acceleration) within a three-day period. A two tailed t-test with statistical significance set at p less than or equal to 0.05 was used to compare treatments. Peak acceleration was 3.4+/-0.1 G(sub z), (head to foot acceleration). Peak oxygen uptake (VO2(sub peak) was not different between treatment groups (3.1+/-0.1 Lmin(exp -1) vs. 3.2+/-0.1 Lmin(exp -1) for stationary and acceleration trials, respectively). Peak HR and pulmonary minute ventilation (V(sub E(sub BTPS))) were significantly elevated (p less than or equal to 0.05) for the acceleration trial (182+/-3 BPM (Beats per Minute); 132.0+/-9.0 Lmin(exp -1)) when compared to the stationary trial (175+/-3 BPM; 115.5+/-8.5 Lmin(exp -1)). Ventilatory threshold expressed as a percent of VO2(sub peak) was not different for acceleration and stationary trials (72+/-2% vs. 68+/-2% respectively). Results suggest that 3.4 G(sub z) acceleration does not alter VO2(sub peak) response to supine cycling. However, peak HR and V(sub E(sub BTPS)) response may be increased while ventilatory threshold response expressed as a function of percent VO2(sub peak) is relatively unaffected. Thus, traditional exercise prescription based on VO2 response would be appropriate for this mode of exercise. Prescriptions based on HR response may require modification.

Vener, J. M.↗

Thermoregulatory effects of caffeine ingestion during rest and exercise in men

Body temperatures and thermoregulatory responses were measured at rest and during submaximal exercise under normal ambient conditions in 11 aerobically-conditioned men (age = 29.2 +/- 6.2 yr, VO2(max) = 3.73 +/- 0.46 min(sup -1), relative body fat = 12.3 +/- 3.7 percent, mean +/- SD) with (CT) and without (NCT) the ingestion of 10 mg of caffeine per kg of body weight. Oxygen uptake (VO2), heart rate (HR), and rectal (T(sub re)) and mean skin (T-bar(sub sk)) temperatures were recorded for 100 minutes starting one minute after ingestion of caffeine or a placebo. Data were collected throughout 30 minutes of rest (sitting) and the following 70 minutes of sitting leg ergometer exercise using the same constant load (1,088 +/- 153 kgm/min) in both NCT and CT. The load resulted in a mean relative exercise intensity equal to approximately 68 percent of VO2(sub max). Skin heat conductance (H(sub sk)) and sweat rate were calculated. Two-way analysis of covariance revealed no significant (P greater than 0.05) differences between NCT and CT in VO2, HR, T(sub re), T-bar(sub sk), or H(sub sk). A dependent t-test indicated no significant difference between NCT and CT in sweat rate. Thus, a high level of caffeine ingestion has no detrimental effects on body temperatures and thermoregulatory responses during moderately heavy exercise in normal ambient conditions.

Dunagan, Nancy↗

Hypervolemia in men from drinking hyperhydration fluids at rest and during exercise

To test the hypothesis that drink composition is more important than drink osmolality (Osm) for maintaining and increasing plasma volume (PV) at rest and during exercise, six men (22-39 yr, 76.84 +/- 16.19 kg, 2.99 +/- 0.45 L/min VO2 peak) each underwent six treatments while sitting for 90 min (VO2 = 0.39 L/min) and then performed upright ergometer exercise for 70 min (VO2 = 2.08 +/- 0.33 1/min, 70% +/- 7% VO2 peak). Drink formulations (10 ml/kg body weight, X = 768 ml) for the sitting period were: P1 (55 mEq Na(+), 365 mOsm/kg H2O), P2 (97.1 mEq Na(+), 791 mOsm/kg), P2G (113 mEqNa(+), 80 ml glycerol, 1,382 mOsm/kg, HyperAde (HA) (164 mEq Na(+), 253 mOsm/kg), and 01 and 02 (no drinking). The exercise drink (10 ml/kg, 768 ml) was P1 for all treatments except 02. Plasma volume at rest increased (p less than 0.05) by 4.7% with P1 and by 7.9% with HA. Percent change in PV during exercise was +1% to +3%0(NS) with HA; -6% to 0% (NS) with P1, P2, P2G, and 01; and -8% to -5% (p less than 0.05) with 02. HyperAde, with the lowest osmolality (253 mOsm/kg), maintained PV at rest and during exercise, whereas the other drinks with lower Na(+) and higher osmolality (365 to 1,382 mOsm/kg) did not. But Performance 1 also increased PV at rest. Thus, drink composition may be more important than drink osmolality for increasing plasma volume at rest and for maintaining it during exercise.

Greenleaf, J. E.↗

Relation of systemic and local muscle exercise capacity to skeletal muscle characteristics in men with congestive heart failure

OBJECTIVES. The present study was undertaken to further characterize changes in skeletal muscle morphology and histochemistry in congestive heart failure and to determine the relation of these changes to abnormalities of systemic and local muscle exercise capacity. BACKGROUND. Abnormalities of skeletal muscle appear to play a role in the limitation of exercise capacity in congestive heart failure, but information on the changes in muscle morphology and biochemistry and their relation to alterations in muscle function is limited. METHODS. Eighteen men with predominantly mild to moderate congestive heart failure (mean +/- SEM New York Heart Association functional class 2.6 +/- 0.2, ejection fraction 24 +/- 2%) and eight age- and gender-matched sedentary control subjects underwent measurements of peak systemic oxygen consumption (VO2) during cycle ergometry, resistance to fatigue of the quadriceps femoris muscle group and biopsy of the vastus lateralis muscle. RESULTS. Peak VO2 and resistance to fatigue were lower in the patients with heart failure than in control subjects (15.7 +/- 1.2 vs. 25.1 +/- 1.5 ml/min-kg and 63 +/- 2% vs. 85 +/- 3%, respectively, both p < 0.001). Patients had a lower proportion of slow twitch, type I fibers than did control subjects (36 +/- 3% vs. 46 +/- 5%, p = 0.048) and a higher proportion of fast twitch, type IIab fibers (18 +/- 3% vs. 7 +/- 2%, p = 0.004). Fiber cross-sectional area was smaller, and single-fiber succinate dehydrogenase activity, a mitochondrial oxidative marker, was lower in patients (both p < or = 0.034). Likewise, the ratio of average fast twitch to slow twitch fiber cross-sectional area was lower in patients (0.780 +/- 0.06 vs. 1.05 +/- 0.08, p = 0.019). Peak VO2 was strongly related to integrated succinate dehydrogenase activity in patients (r = 0.896, p = 0.001). Peak VO2, resistance to fatigue and strength also correlated significantly with several measures of fiber size, especially of fast twitch fibers, in patients. None of the skeletal muscle characteristics examined correlated with exercise capacity in control subjects. CONCLUSIONS. These results indicate that congestive heart failure is associated with changes in the characteristics of skeletal muscle and local as well as systemic exercise performance. There are fewer slow twitch fibers, smaller fast twitch fibers and lower succinate dehydrogenase activity. The latter finding suggests that mitochondrial content of muscle is reduced in heart failure and that impaired aerobic-oxidative capacity may play a role in the limitation of systemic exercise capacity.

Non-NASA Center↗

Role of O2 in regulating tissue respiration in dog muscle working in situ

This study was designed to investigate the role of tissue oxygenation in some of the factors that are thought to regulate muscle respiration and metabolism. Tissue oxygenation was altered by reductions in O2 delivery (muscle blood flow x arterial O2 content), induced by decreases in arterial PO2 (PaO2). O2 uptake (VO2) was measured in isolated in situ canine gastrocnemius at rest and while working at two stimulation intensities (isometric tetanic contractions at 0.5 and 1 contractions/s) on three separate occasions, with only the level of PaO2 (78, 30, and 21 Torr) being different for each occasion. Muscle blood flow was held constant (pump perfusion) at each work intensity for the three different levels of PaO2. Muscle biopsies were obtained at the end of each rest and work period. Muscle VO2 was significantly less (P less than 0.05) at both stimulation intensities for the hypoxemic conditions, whereas [ATP] was reduced only during the highest work intensity during both hypoxemic conditions (31% reduction at 21 Torr PaO2 and 17% at 30 Torr). For each level of PaO2, the relationships between the changes that occurred in VO2 and levels of phosphocreatine, ADP, and ATP/ADP.P(i) as the stimulation intensity was increased were significantly correlated; however, the slopes and intercepts of these lines were significantly different for each PaO2. Thus a greater change in any of the proposed regulators of tissue respiration (e.g., phosphocreatine, ADP) was required to achieve a given VO2 as PaO2 was decreased.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

Teal Cycle Ergometer Vibration Isolation and Stabilization System Human-in-the-Loop Ground Evaluation for Long-Duration Spaceflight

Purpose: To counter the deleterious effects of weightlessness on the cardiopulmonary system, astronauts living on the International Space Station exercise on a variety of countermeasure equipment including the Cycle Ergometer Vibration Isolation and Stabilization System (CEVIS). Operational since 2001, the onboard CEVIS will be replaced by a new model, known as Teal CEVIS (TC). As a part of ground evaluation, TC hardware underwent human-in-the-loop (HITL) testing to verify the TC hardware produces workloads that elicit physiologic responses comparable to a laboratory cycle ergometer (LAB). Methods: Seven subjects (5 M/2 F) performed submaximal cycle ergometer testing with indirect calorimetry measures on TC and LAB on separate test days. Testing consisted of graded 30 watt increases in workload until subjects reached 85% of age-predicted max heart rate (HR). Exercise outcomes included rate of oxygen uptake (VO2; liters/min), rate of energy expenditure (REE; kcal/min), and HR (beats/min). Linear mixed models (LMM) were fitted to compare VO2, REE, and HR responses between devices across power outputs with fixed effects for power (P) and device (D) and with random effects for subject. LMM effect coefficients (β), std errors (SE), pseudo-partial R2 of effects (pR2), and model likelihood ratio statistics (χ2, Pr(> chisq); α<.05) are provided. Results: LMM main effects for P and D were observed for VO2 (βp=.0107, SE = .0002, pR2=0.97; βd = -0.075, SE = 0.019, pR2=0.14; χ2(1)= 13.57, p<.001), such that VO2 was higher across stages on TC. Main effects of P and D were observed for REE (βp= .0586, SE = 0.001, pR2= 0.97; βd = -0.33208, SE = 0.099, pR2= 0.056; χ2(1)=10.481, p < .01), such that REE was higher across power outputs on TC. A P x D interaction was observed for HR, along with main effects for P and D (βp x d =-0.048, SE = 0.02, pR2=0.048; βp= 0.42, SE = 0.016, pR2=0.87; χ2(1) = 5.398, p = 0.02), such that higher workloads elicited a greater difference in HR between devices. Conclusions: HITL results show, TC elicits greater physiologic responses across power outputs compared to LAB. However, pR2 for device effects show small differences between devices. Therefore, TC can be expected to provide appropriate physiological stimulus across workloads and be considered a reliable tool to mitigate the effects of weightlessness.

Cycle Ergometer Vibration and Isolation System↗

Work capacity during 30 days of bed rest with isotonic and isokinetic exercise training

Results are presented from a study to determine whether or not short-term variable intensity isotonic and intermittent high-intensity isokinetic short-duration leg exercise is effective for the maintenance of peak O2 (VO2) uptake and muscular strength and endurance, respectively, during 30 days of -6 deg head-down bed rest deconditioning. The results show no significant changes in leg peak torque, leg mean total work, arm total peak torque, or arm mean total work for members of the isotonic, isokinetic, and controls groups. Changes are observed, however, in peak VO2 levels. The results suggest that near-peak variabile intensity, isotonic leg excercise maintains peak VO2 during 30 days of bed rest, while peak intermittent, isokinetic leg excercise protocol does not.

Greenleaf, J. E.↗

High degree gravitational sensitivity from Mars orbiters for the GMM-1 gravity model

Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.

Lerch, F. J.↗

Intensive Exercise Training During Bed Rest Attenuates Deconditioning

Intensive exercise training during bed rest attenuates deconditioning. Med. Sci. Sports Exerc., Vol. 29, No. 2, pp. 207-215, 1997. A 30-d 6 deg head-down bed rest project was conducted to evaluate variable high-intensity, short-duration, isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent resistive isokinetic exercise (IKE) training regimens designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (adaptive) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Major findings are summarized in this paper. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volumes, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (f) attenuated the decrease in peak VO2 by 50%, (g) attenuated loss of red cell volume by 40% but had no effect on loss of plasma volume, (b) induced positive body water balance, (i) had no adverse effect on quality of sleep or concentration, and 0) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regimens and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

Greenleaf, John E.↗

Exercise Training During Bed Rest Attenuates Deconditioning

A 30-day 6 deg. head-down bed rest study was conducted to evaluate high-intensity, short-duration, alternating isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent isokinetic exercise (IKE) training regiments designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (acclimation) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volume, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (a) attenuated the decrease in peak VO2 by 50%, (b) attenuated loss of red cell volume by 40%, but had no effect on loss of plasma volume, (c) induced positive body water balance, (d) had no adverse effect on quality of sleep or concentration, and (e) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regiments, and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

Greenleaf, J. E.↗

Pre-exercise hypervolemia and cycle ergometer endurance in men

Time to exhaustion at 87-91% of peak VO2 was measured in 5 untrained men (age: 31 +/- 8 years, body mass: 74.20 +/- 16.50 kg, body surface area: 1.90 +/- 0.24 m2, peak VO2: 2.87 +/- 0.40 l min-1, plasma volume: 3.21 +/- 0.88 l; means +/-SD) after consuming nothing (N) or two fluid formulations (10 ml kg-1, 743 +/- 161 ml): Performance 1 (P1), a multi-ionic carbohydrate drink, containing 55 mEq l-1 Na+, 4.16 g l-1 citrate, 20.49 g l-1 glucose, and 365 mOsm kg-1 H2O, and AstroAde (AA), a sodium chloride-sodium citrate hyperhydration drink, containing 164 mEq l-1 Na+, 8.54 g l-1 citrate, <5 mg l-1 glucose, and 253 mOsm kg-1 H2O. Mean (+/-SE) endurance for N, P1 and AA was 24.68 +/- 1.50, 24.55 +/- 1.09, and 30.50 +/- 3.44 min respectively. Percent changes in plasma volume (PV) from -105 min of rest to zero min before exercise were -1.5 +/- 3.2% (N), 0.2 +/- 2.2% (P1), and 4.8 +/- 3.0% (AA; P < 0.05). The attenuated endurance for N and P1 could not be attributed to differences in exercise metabolism (VE, RE, VO2) from the carbohydrate or citrate, terminal heart rate, levels of perceived exertion, forehead or thigh skin blood flow velocity, changes or absolute termination levels of rectal temperature. Thus, the higher level of resting PV for AA just before exercise, as well as greater acid buffering and possible increased energy substrate from citrate, may have contributed to the greater endurance.

NASA Center ARC↗

Validation of the Pulmonary Function System for Use on the International Space Station

Aerobic deconditioning occurs during long duration space flight despite the use of exercise countermeasures (Convertino, 1996). As a part of International Space Station (ISS) medical operations, periodic tests designed to estimate aerobic capacity are performed to track changes in aerobic fitness and to determine the effectiveness of exercise countermeasures. These tests are performed prior to, during, and after missions of greater than 30 days in duration. Crewmembers selected for missions aboard the ISS perform a graded exercise test on a cycle ergometer approximately 270 days prior to their scheduled launch date in order to measure peak oxygen consumption (VO2PK) and peak heart rate (HRpk). Approximately 30 to 45 days prior to launch, crewmembers perform a submaximal cycle ergometer test at work rates set to elicit 25, 50 and 75% of their pre-flight VO2PK. This test, known as the Periodic Fitness Evaluation (PFE), serves as a baseline measure to which subsequent in-and post-flight exercise tests are compared. While onboard the ISS, crewmembers are normally scheduled to perform the PFE beginning with flight day (FD) 14 and every 30 days thereafter. The PFE is also conducted 5 and 30 days following flight. Using PFE data, aerobic fitness is estimated by quantifying the VO2 vs. HR relationship using linear regression and calculating the VO2 that would occur at the crewmember s previously measured HRpk. Currently, for data collected during flight, this technique assumes that the pre- vs. in-flight oxygen consumption per given cycle workload is similar. However, the validity of this assumption is based upon a sparse amount of data collected during the Skylab era (Michel, et al. 1977). The method of using heart rate and cycle ergometer work rates has been used to estimate aerobic fitness in normal gravity (Astrand and Ryhming, 1954; Lee, 1993). Due to spaceflight induced physiological alterations, such as shifts in extracellular fluid (e.g. plasma) volume, this method may not be valid during space flight. In addition, the ergometer onboard ISS is vibration-isolated and moves with the astronaut s application of force into the pedals. The effect of this movement on the VO2 of cycle exercise on ISS has not been quantified.

McCleary, Frank A.↗

Determinants of Time to Fatigue during Non-Motorized Treadmill Exercise

Treadmill exercise is commonly used for aerobic and anaerobic conditioning. During non-motorized treadmill exercise, the subject must provide the power necessary to drive the treadmill belt. The purpose of this study was to determine what factors affected the time to fatigue on a pair of non-motorized treadmills. Twenty subjects (10 males/10 females) attempted to complete five minutes of locomotion during separate trials at 3.22, 4.83, 6.44, 8.05, 9.66, and 11.27 km (raised dot) h(sup -1). Total exercise time (less than or equal to 5 min) was recorded. Exercise time was converted to the amount of 15 second intervals completed. Peak oxygen uptake (VO2) was measured using a graded exercise test on a standard treadmill, and anthropometric measures were collected from each subject before entering into the study. A Cox proportional hazards regression model was used to determine significant predictive factors in a multivariate analysis. Non-motorized treadmill speed and absolute peak VO2 were found to be significant predictors of exercise time, but there was no effect of anthropometric characteristics. Gender was found to be a predictor of treadmill time, but this was likely due to a higher peak VO2 in males than in females. These results were not affected by the type of treadmill tested in this study. Coaches and therapists should consider the cardiovascular fitness of an athlete or client when prescribing target speed since these factors are related to the total exercise time than can be achieved on a non-motorized treadmill.

DeWitt, John K.↗

Physiologic Responses to Motorized and Non-Motorized Locomotion Utilizing the International Space Station Treadmill

Treadmill locomotion is used onboard the International Space Station (ISS) as a countermeasure to the effects of prolonged weightlessness. The treadmill operates in two modes: motorized (T-M) and non-motorized (T-NM). Little is known about the potential physiologic differences between modes which may affect countermeasure exercise prescription. PURPOSE: To quantify heart rate (HR), oxygen consumption (VO2), perceived exertion (RPE), and blood lactate (BLa) during T-M and T-NM locomotion at 2 and 4 mph in normal ambulatory subjects. METHODS: Twenty subjects (10 men, 10 women; 31+/-5 yr, 172+/-10 cm, 68+/-13 kg, mean SD) with a treadmill peakVO2 of 45.5+/-5.4 ml/kg/min (mean+/-SD) exercised on the ground-based ISS treadmill. Following a familiarization session in each mode, subjects completed two data collection sessions, T-M and T-NM in random order, at 2 and 4 mph. Subjects attempted to complete 5 min of exercise at each speed; if they could not maintain the speed, the trial was discontinued. At least 5 minutes of rest separated each speed trial, and at least 48 hrs separated each session. VO2 was measured continuously (metabolic gas analysis), while HR (HR monitor) and RPE (Borg Chart, 6-20 scale) were recorded each min. Not all subjects completed 5 min during each condition, therefore the mean of the min 3 and 4 was taken as representative of steady-state. BLa was measured (finger stick) within 2 min post-exercise. Paired t-tests were used to test for differences (p<0.05) between treadmill modes within the same speed. RESULTS: All twenty subjects completed at least 4 min of exercise during all conditions, except T-NM 4 mph when only 11 subjects completed the minimum exercise duration. VO2, HR, RPE and BLa were significantly higher during T-NM locomotion at both speeds.

Smith, Cassie↗

Effect of Pharmacologically-Induced Hypovolemia on Aerobic Capacity

Decreased peak oxygen consumption (VO2pk) and an elevated exercise heart rate (HR) response are associated with a reduction in plasma volume (PV) after space flight and bed rest, a space flight analog. Reduced VO2pk and submaximal exercise tolerance would negatively impact an astronaut s ability to perform near maximal work that would be required in the event of an emergency. We previously have administered IV furosemide followed by a low salt diet to model PV loss and orthostatic intolerance observed after spaceflight. Purpose: To determine whether a pharmacologically-induced reduction in PV results in decreased VO2pk and elevated exercise HR response. Methods: Six subjects (5M, 1F) performed two graded peak cycle tests (work rate increased by 35 or 50 W every 3 min), once while normovolemic and once while hypovolemic. HR and expired respiratory gases were continuously measured. To induce hypovolemia, subjects were administered a single dose of IV furosemide (0.5 mg.kg-1) 30 hr before exercise testing and then consumed a low-salt diet (10 mEq.d(sup -1)). PV was measured using carbon monoxide rebreathing. Exercise HR and VO2 responses were quantified as the area under the curve (AUC) calculated over each quartile of the peak test, based on test time in the hypovolemia condition. Paired t-tests were used to test for differences in PV, VO2pk, and peak HR between conditions. Repeated-measures ANOVAs were used to test for differences in AUC between conditions. Results: PV (3.32+/-0.12 vs. 2.77+/-0.16 L, p<0.05) and VO2pk (3.30+/-0.67 vs. 2.90+/-0.57 L.min(sup -1), p<0.05) were lower during hypovolemia than during normovolemia, but peak HR was not different (187+/-5 vs. 187+/-5 bpm). The AUC for VO2 and HR was different (p<0.05) between conditions only in the highest quartile: HR was 4% higher and VO2 was 5% lower during the hypovolemia condition. Conclusion: The mean difference in VO2pk (-12%) between normovolemia and hypovolemia was similar to the mean difference in PV (-17%). Similar decreases in PV and VO2pk have been observed following short duration space flight, suggesting that pharmacologically-induced PV loss can be used to model microgravity-induced reductions in VO2pk.

Everett, Meghan E.↗