Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Shock compression of FeOOH and implications for iron-water interactions in super-earth magma oceans

Iron(Fe)-water reactions in a magma ocean can influence water storage and density of planets. These reactions can form Fe-O-H phases, whose density, melting, and electronic properties at planetary interior conditions are important for informing planetary models. Here, we study natural goethite (α-FeOOH) that is shock-compressed along its principal Hugoniot. Analysis of our velocity interferometer system for any reflector (VISAR) results extends the equation of state to over 800 GPa. X-ray diffraction and VISAR reflectivity results indicate the onset of melting occurs at ~95 GPa with complete melting by 166 GPa, which may be relevant to low seismic velocity anomalies observed above the core-mantle boundary. Analysis of X-ray emission spectroscopy results up to 285 GPa shows the spin crossover of Fe, with dominantly low spin Fe above ~265 GPa in the melt, supporting formation of dense basal magma oceans in terrestrial planets. Using our measured FeOOH densities, we model planetary interiors up to 10 Earth masses. Assuming FeOOH forms via iron-water reactions, the radius decreases by up to 28%, while the density increases by up to 165% compared to the unreacted cases, providing an avenue to investigate water storage and evolution in super-Earths and sub-Neptunes.

Zhang, Yanyao [Stanford Univ., CA (United States)]↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Portable fiber optic coupled Doppler interferometer system for detonation and shock wave diagnostics

Testing and analysis of shock wave characteristics such as detonators and ground shock propagation frequently require a method of measuring velocity and displacement of the surface of interest. One method of measurement is Doppler interferometry. The VISAR (Velocity Interferometer System for Any Reflector) uses Doppler interferometry and has gained wide acceptance as the preferred tool for shock measurement. An important asset of VISAR is that it measures velocity and displacement nonintrusively.

Fleming, Kevin J.↗

Unique passive diagnostic for slapper detonators

The objective of this study was to find a material and configuration that could reliably detect the proper functioning of a slapper (non-explosive) detonator. Because of the small size of the slapper geometry (on the order of a 15 mils), most diagnostic techniques are not suitable. This program has the additional requirements that the device would be used on centrifuge so that it could not use any electrical power or output signals. This required that the diagnostic be completely passive. The paper describes the three facets of the development effort: complete characterization of the slapper using VISAR measurements, selection of the diagnostic material and configuration, and testing of the prototype designs. The VISAR testing required that use of a special optical probe to allow the laser light to reach both bridges of the dual-slapper detonator. Results are given in the form of flyer velocity as a function of the initiating charge voltage level. The selected diagnostic design functions in a manner similar to a dent block except that the impact of the Kapton disk from a properly-functioning slapper causes a fracture pattern. A quick visual inspection is all that is needed to determine if the flyer velocity exceeded the threshold value. Sub-threshold velocities produce a substantially different appearance.

Brigham, William P.↗

Innovative Solution to Video Enhancement

Through a licensing agreement, Intergraph Government Solutions adapted a technology originally developed at NASA's Marshall Space Flight Center for enhanced video imaging by developing its Video Analyst(TM) System. Marshall's scientists developed the Video Image Stabilization and Registration (VISAR) technology to help FBI agents analyze video footage of the deadly 1996 Olympic Summer Games bombing in Atlanta, Georgia. VISAR technology enhanced nighttime videotapes made with hand-held camcorders, revealing important details about the explosion. Intergraph's Video Analyst System is a simple, effective, and affordable tool for video enhancement and analysis. The benefits associated with the Video Analyst System include support of full-resolution digital video, frame-by-frame analysis, and the ability to store analog video in digital format. Up to 12 hours of digital video can be stored and maintained for reliable footage analysis. The system also includes state-of-the-art features such as stabilization, image enhancement, and convolution to help improve the visibility of subjects in the video without altering underlying footage. Adaptable to many uses, Intergraph#s Video Analyst System meets the stringent demands of the law enforcement industry in the areas of surveillance, crime scene footage, sting operations, and dash-mounted video cameras.

Source record↗

Towards the Ultimate Strength of Medium‐Entropy Alloys Through Pulsed Lasers

The tensile strength of metals at extreme strain rates is a key predictor of their performance in ballistic and structural impact applications. An important experimental method to reach these extreme strain rates is the use of high-amplitude, short-duration pulsed lasers. The Jupiter Laser Facility at the Lawrence Livermore National Laboratory enabled probing for the first time the mechanical response of several promising High Entropy Alloys at times on the order of nanoseconds (strain rates of ∼10 7 and ∼10 9 s −1 ). The measured strength is in the range of 6 to 10 GPa, ten times the quasistatic value. The mechanisms of plastic deformation and failure were identified and quantified through analysis and molecular dynamics simulation. The reflected wave amplitudes, obtained by VISAR, were used to determine the tensile (spall) stress. The high tensile strength obtained is due to two factors: the strain-rate dependence of plastic flow and the kinetics of void nucleation, growth, and coalescence. The experimental results are compared with an analytical prediction considering both grain-interior and grain-boundary void initiation. Molecular dynamics simulations, conducted at strain rates of 10 8 and 10 9 s −1 , rationalize the experimental results. In conclusion, they provide valuable information about the process of failure evolution, and reveal that grain boundary separation plays a pivotal role in spalling.

Materials science↗

Exceptionally high spallation strength for a high-entropy alloy demonstrated by experiments and simulations

High-entropy alloys are materials with an increasing number of technological applications. Amongst them, the Cantor alloy, FeMnCoCrNi, shows desirable mechanical properties at normal loading conditions. In this study we focus on the performance of the Cantor alloy at the ultra-high deformation rates of shock waves. We study shock-induced spallation using both experiments and atomistic simulations. Experimental loading is achieved using high power laser, with VISAR to obtain velocity profiles and spall strength, followed by transmission electron microscopy of the recovered samples. Molecular Dynamics (MD) simulations of shock-induced spallation are compared with experiments. Both experiments and simulations show a high spall strength which would be beneficial for certain applications, with experiments giving ~8 GPa at ~10 7 s -1 and MD giving almost ~30 GPa at ~10 9 s -1 . The difference between experiments and simulations can be explained by the difference in strain rate. Post-mortem analysis of the experimental samples shows nanotwins near the spall plane, while MD simulations show a highly disordered region giving rise to void nucleation and spall during loading.

36 MATERIALS SCIENCE↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

Evaluation of RMI Ejecta Sourcing from Reconstructed Interfaces in 2D FLAG Flyer-Plate Simulations

This study investigates the performance of RMI ejecta sourcing from a reconstructed interface in two-dimensional FLAG ejecta flyer-plate simulations. Enabling the RMI ejecta model to operate on reconstructed interfaces has been a longstanding challenge in FLAG, limiting its applicability to experiments in which interface reconstruction is not required. Addressing this limitation is therefore an important step toward expanding the model’s predictive capability. The first phase of this effort focused on identifying a flyer-plate/target configuration that produces large ejecta clouds from two distinct shocks using the standard RMI ejecta model. A series of simulations examined the effects of flyer composition, layer thickness, and mesh resolution on shock structure and ejecta formation. VISAR traces were used to evaluate shock timing and identify configurations that produced a clear double-shock response. A copper middle-layer flyer with a doubled tin layer yielded the most favorable shock characteristics and was selected as the baseline configuration. After confirming this configuration performed as expected when running a reference FLAG version, it became the basis for three simulations: (1) a standard two-dimensional ejecta flyer-plate calculation using a reference FLAG version, (2) the same calculation with the reconstructed interface option enabled, and (3) a calculation employing ALE strategies to force the ejecta model to operate on the reconstructed interface. While the baseline simulation produced the expected ejecta response, the reconstructed interface approach did not result in measurable ejecta, indicating that this capability remains under development. These results highlight both the progress made and the remaining challenges in extending the RMI ejecta model to reconstructed interfaces.

36 MATERIALS SCIENCE↗

Cable Discharge System for fundamental detonator studies

Sandia National Laboratories has recently completed the modification and installation of a cable discharge system (CDS) which will be used to study the physics of exploding bridgewire (EBW) detonators and exploding foil initiators (EFI or slapper). Of primary interest are the burst characteristics of these devices when subjected to the constant current pulse delivered by this system. The burst process involves the heating of the bridge material to a conductive plasma and is essential in describing the electrical properties of the bridgewire foil for use in diagnostics or computer models. The CDS described herein is capable of delivering up to an 8000 A pulse of 3 micron duration. Experiments conducted with the CDS to characterize the EBW and EFI burst behavior are also described. In addition, the CDS simultaneous VISAR capability permits updating the EFI electrical Gurney analysis parameters used in our computer simulation codes. Examples of CDS generated data for a typical EFI and EBW detonator are provided.

Peevy, Gregg R.↗

Mars Observer Propulsion and Pyrotechnics Corrective Actions Test Program Status-1999

An extensive propulsion and pyrotechnic test program has been in progress at the NASA White Sands Test Facility since 1995. This program created the capabilities to: accurately measure and characterize pyrovalve combustion product blow-by into propellant systems; characterize valve operation using a Velocity Interferometer System for Any Reflector (VISAR); and evaluate hydrazine and monomethylhydrazine thermal decomposition initiated by blow-by. These capabilities were further utilized and refined this year. Low blow-by pyrovalves manufactured by Conax Florida Corporation continued to be evaluated as a potential corrective measure for blow-by induced propellant explosions. Development and testing of various advanced pyrovalves and investigation of explosion mechanisms also continued. Current and near-term testing includes: evaluation of 3/8 in. Conax pyrovalves and other commercially available valves; development and testing of advanced pyrovalve subcomponent technologies including a zero blow-by pyrovalve ram, composite overwrapped ram cylinder, and a zero particulate generating poppet; investigation of non-destructive evaluation techniques to evaluate pyrovalve ram seals; and testing and modeling of pyrotechnically induced explosive hydrazine decomposition. Evaluation of 3/8 in. Conax valves will include operational margin testing to be accomplished at NASA Langley Research Center. The test program also seeks to compile and format significant amounts of data from this and other pyrovalve test programs to generate a pyrovalve applications handbook. The handbook will facilitate formation of standards that ensure safe spacecraft applications. Current data and future plans are discussed, and community interaction is encouraged.

Saulsberry, Regor↗

Ignition-and-Growth Modeling of NASA Standard Detonator and a Linear Shaped Charge

The main objective of this study is to quantitatively investigate the ignition and shock sensitivity of NASA Standard Detonator (NSD) and the shock wave propagation of a linear shaped charge (LSC) after being shocked by NSD flyer plate. This combined explosive train was modeled as a coupled Arbitrary Lagrangian-Eulerian (ALE) model with LS-DYNA hydro code. An ignition-and-growth (I&G) reactive model based on unreacted and reacted Jones-Wilkins-Lee (JWL) equations of state was used to simulate the shock initiation. Various NSD-to-LSC stand-off distances were analyzed to calculate the shock initiation (or failure to initiate) and detonation wave propagation along the shaped charge. Simulation results were verified by experimental data which included VISAR tests for NSD flyer plate velocity measurement and an aluminum target severance test for LSC performance verification. Parameters used for the analysis were obtained from various published data or by using CHEETAH thermo-chemical code.

Oguz, Sirri↗