Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION TESTING MACHINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A magnetic damper for first mode vibration reduction in multimass flexible rotors

Many rotating machines such as compressors, turbines and pumps have long thin shafts with resulting vibration problems, and would benefit from additional damping near the center of the shaft. Magnetic dampers have the potential to be employed in these machines because they can operate in the working fluid environment unlike conventional bearings. An experimental test rig is described which was set up with a long thin shaft and several masses to represent a flexible shaft machine. An active magnetic damper was placed in three locations: near the midspan, near one end disk, and close to the bearing. With typical control parameter settings, the midspan location reduced the first mode vibration 82 percent, the disk location reduced it 75 percent and the bearing location attained a 74 percent reduction. Magnetic damper stiffness and damping values used to obtain these reductions were only a few percent of the bearing stiffness and damping values. A theoretical model of both the rotor and the damper was developed and compared to the measured results. The agreement was good.

Kasarda, M. E. F.↗

Basic space payload fastener

A new basic space fastener has been developed and tested by the GSFC. The purposes of this fastener are to permit assembly and servicing in space by astronauts and/or robots and to facilitate qualification of payloads on Earth prior to launch by saving time and money during the systems integration and component testing and qualification processes. The space fastener is a rework of the basic machine screw such that crossthreading is impossible; it is self-locking and will not work its way out during launch (vibration proof); it will not wear out despite repeated use; it occupies a small foot print which is comparable to its machine screw equivalent, and it provides force and exhibits strength comparable to its machine screw equivalent. Construction is ultra-simple and cost effective and the principle is applicable across the full range of screw sizes ranging from a #10 screw to 2.5 cm (1 in) or more. In this paper, the fastener principles of operation will be discussed along with test results and construction details. The new fastener also has considerable potential in the commercial sector. A few promising applications will be presented.

Vranish, J. M.↗

Vibration damping characteristics of graphite/epoxy composites for large space structures

Limited data on extensional and flexural damping of small specimens of graphite/epoxy and unreinforced epoxy resin were obtained. Flexural damping was measured using a forced vibration technique based on resonant flexural vibration of shaker excited double cantilever specimens. Extensional damping was measured by subjecting similar specimens to low frequency sinusoidal oscillation in a servohydraulic tensile testing machine while plotting load versus extensional strain. Damping was found to vary slowly and continuously over the frequency range 0.01 - 1000 Hz, and no drastic transitions were observed. Composite damping was found to be less than neat resin damping. Comparison of small specimen damping values with assembled column damping values seems to indicate that, for those materials, material damping is more important than joint damping. The data reported was limited not by the test apparatus, but by signal conditioning and data acquisition. It is believed that filtering of the strain gage signals and the use of digital storage with slow playback will make it possible to extend the frequency and amplitude ranges significantly.

Gibson, R. F.↗

Machine Tests Optical Fibers In Flexure

Machine repeatedly flexes single optical fiber or cable or bundle of optical fibers at low temperature. Liquid nitrogen surrounds specimen as it is bent back and forth by motion of piston. Machine inexpensive to build and operate. Tests under repeatable conditions so candidate fibers, cables, and bundles evaluated for general robustness before subjected to expensive shock and vibration tests.

Darejeh, Hadi↗

Emerging technologies in microguidance and control

Employing recent advances in microfabrication, the Charles Stark Draper Laboratory has developed inertial guidance instruments of very small size and low cost. Microfabrication employs the batch processing techniques of solid state electronics, such as photolithography, diffusion, and etching, to carve mechanical parts. Within a few years, microfabricated gyroscopes should perform in the 10 to 100 deg/h range. Microfabricated accelerometers have demonstrated performance in the 50 to 500 microgravity range. These instruments will result in not only the redesign of conventional military products, but also new applications that could not exist without small, inexpensive sensors and computing. Draper's microfabricated accelerometers and gyroscopes will be described and test results summarized. Associated electronics and control issues will also be addressed. Gimballed, vibrating gyroscopes and force rebalance accelerometers constructed from bulk silicon, polysilicon surface-machined tuning fork gyroscopes, and quartz resonant accelerometers and gyroscopes are examined. Draper is pursuing several types of devices for the following reasons: to address wide ranges of performance, to realize construction in a flat pack, and to lessen the risks associated with emerging technologies.

Weinberg, Marc S.↗

Design and Evaluation of a New Boundary-Layer Rake for Flight Testing

A new boundary-layer rake has been designed and built for flight testing on the NASA Dryden Flight Research Center F-15B/Flight Test Fixture. A feature unique to this rake is its curved body, which allows pitot tubes to be more densely clustered in the near-wall region than conventional rakes allow. This curved rake design has a complex three-dimensional shape that requires innovative solid-modeling and machining techniques. Finite-element stress analysis of the new design shows high factors of safety. The rake has passed a ground test in which random vibration measuring 12 g rms was applied for 20 min in each of the three normal directions. Aerodynamic evaluation of the rake has been conducted in the NASA Glenn Research Center 8 x 6 Supersonic Wind Tunnel at Mach 0-2. The pitot pressures from the new rake agree with conventional rake data over the range of Mach numbers tested. The boundary-layer profiles computed from the rake data have been shown to have the standard logarithmic-law profile. Skin friction values computed from the rake data using the Clauser plot method agree with the Preston tube results and the van Driest II compressible skin friction correlation to approximately +/-5 percent.

Bui, Trong T.↗

Analysis and modification of a single-mesh gear fatigue rig for use in diagnostic studies

A single-mesh gear fatigue rig was analyzed and modified for use in gear mesh diagnostic research. The fatigue rig allowed unwanted vibration to mask the test-gear vibration signal, making it difficult to perform diagnostic studies. Several possible sources and factors contributing to the unwanted components of the vibration signal were investigated. Sensor mounting location was found to have a major effect on the content of the vibration signal. In the presence of unwanted vibration sources, modal amplification made unwanted components strong. A sensor location was found that provided a flatter frequency response. This resulted in a more useful vibration signal. A major network was performed on the fatigue rig to reduce the influence of the most probable sources of the noise in the vibration signal. The slave gears were machined to reduce weight and increase tooth loading. The housing and the shafts were modified to reduce imbalance, looseness, and misalignment in the rotating components. These changes resulted in an improved vibration signal, with the test-gear mesh frequency now the dominant component in the signal. Also, with the unwanted sources eliminated, the sensor mounting location giving the most robust representation of the test-gear meshing energy was found to be at a point close to the test gears in the load zone of the bearings.

Zakrajsek, James J.↗

Creep Strength of Stabilized Wrought-aluminum Alloys

Rohn-type equipment has been mounted on rubber blocks, for the purpose of damping the vibrations of the ground and of rendering the plastic yielding of the test bars less subject to outside interferences. New equipment also included three shockproof creep-testing machines with the Martens mirror instruments for recording the strain curve of the fatigue-tested specimens.

Muller, W↗

Life and Reliability Characteristics of TurboBrayton Coolers

Wear and internal contaminants are two of the primary factors that influence reliable, long-life operation of turbo-Brayton cryocoolers. This paper describes tests that have been conducted and methods that have been developed for turbo-Brayton components and systems to assure reliable operation. The turbomachines used in these coolers employ self-acting gas bearings to support the miniature high-speed shafts, thus providing vibration-free operation. Because the bearings are self-acting, rubbing contact occurs during initial start-up and shutdown of the machines. Bearings and shafts are designed to endure multiple stop/start cycles without producing particles or surface features that would impair the proper operation of the machines. Test results are presented for a variety of turbomachines used in these systems. The tests document extended operating life and start/stop cycling behavior for machines over a range of time and temperature scales. Contaminants such as moisture and other residual gas impurities can be a source of degraded operation if they freeze out in sufficient quantities to block flow passages or if they mechanically affect the operation of the machines. A post-fabrication bakeout procedure has been successfully used to reduce residual internal contamination to acceptable levels in a closed cycle system. The process was developed during space qualification tests on the NICMOS cryocooler. Moisture levels were sampled over a six-month time interval confirming the effectiveness of the technique. A description of the bakeout procedure is presented.

Breedlove, Jeff J.↗

Design of a Long-Stroke Noncontact Electromagnetic Actuator for Active Vibration Isolation

A long-stroke moving coil Lorentz Actuator was designed for use in a microgravity vibration isolation experiment. The final design had a stroke of 5.08 cm (2 in) and enough force capability to isolate a mass of the order of 22.7-45.4 kg. A simple dynamic magnetic circuit analysis, using an electrical analog, was developed for the initial design of the actuator. A neodymium-iron-boron material with energy density of 278 T-kA/m (35 MGOe) was selected to supply the magnetic field. The effect of changes in the design parameters of core diameter, shell outer diameter, pole face length, and coil wire layers were investigated. An extensive three-dimensional finite element analysis was carried out to accurately determine linearity with regard to axial position of the coil and coil current levels. The actuator was constructed and tested on a universal testing machine. Example plots are shown, indicating good linearity over the stroke of approximately 5.08 cm (2 in) and a range of coil currents from -1.5 A to +1.5 A. The actuator was then used for the microgravity vibration isolation experiments, described elsewhere.

Banerjee, Bibhuti↗

Structural design and analysis for an ultra low CTE optical bench for the Hubble Space Telescope corrective optics

The stringent stability requirements of the Corrective Optics Space Telescope Axial Replacement (COSTAR) necessitates a Deployable Optical Bench (DOB) with both a low CTE and high resonant frequency. The DOB design consists of a monocoque thin shell structure which marries metallic machined parts with graphite epoxy formed structure. Structural analysis of the DOB has been integrated into the laminate design and optimization process. Also, the structural analytical results are compared with vibration and thermal test data to assess the reliability of the analysis.

Neam, Douglas C.↗

Advanced Stirling Convertor (ASC) - From Technology Development to Future Flight Product

The Advanced Stirling Convertor (ASC) is being developed by Sunpower, Inc. under contract to NASA s Glenn Research Center (GRC) with critical technology support tasks lead by GRC. The ASC development, funded by NASA s Science Mission Directorate, started in 2003 as one of 10 competitively awarded contracts that were to address future Radioisotope Power System (RPS) advanced power conversion needs. The ASC technology has since evolved through progressive convertor builds and successful testing to demonstrate high conversion efficiency (38 %), low mass (1.3 kg), hermetic sealing, launch vibration simulation, EMI characterization, and is undergoing extended operation. The GRC and Sunpower team recently delivered three ASC-E machines to the Department of Energy (DOE) and Lockheed Martin Space Systems Company, two units for integration onto the Advanced Stirling Radioisotope Generator Engineering Unit (ASRG EU) plus one spare. The design has recently been initiated for the ASC-E2, an evolution from the ASC-E that substitutes higher temperature materials enabling improved performance and higher reliability margins. This paper summarizes the history and status of the ASC project and discusses plans for this technology which enables RPS specific power of 8 W/kg for future NASA missions.

Wong, Wayne A.↗

Additively Manufactured Plastic Plasma Spectrometer

We report results in development and testing of a low resource top hat electrostatic analyzer (ESA) for space plasma measurements. This device has been additively manufactured (3D-printed) using fused deposition modeling. The classic top hat design is composed of four plastic pieces, without any surface coatings. The three conducting electrodes are printed from carbon nanotube infused polyether ether ketone (CNT-PEEK). The fourth piece, an insulating electrode support, uses pure PEEK. This ESA is designed to detect electrons in space from 10eV up to 30 keV. We demonstrate that the printed CNT-PEEK is sufficiently electrically conductive to support the fast high voltage slewing often required for high time resolution measurements. The plastic ESA has been successfully vibrated beyond standard pre-flight levels, tested under keV electron beam illumination over a wide range of temperatures, and tested under UV illumination, simulating the solar Ly-α flux. In comparison with an identical machined aluminum ESA, our CNT-PEEK ESA provides nominal energy/angle band passes, closely matching simulation. These band passes imply minimal impact from surface charging at beam energies of 2-3 keV, although more investigation is needed. We also find that the CNT-PEEK ESA provides far superior out-of-band electron rejection and UV photon rejection compared to the machined aluminum ESA. We do not detect any problems with trapped gases or outgassing. This development offers potential for significant mass savings, implementation of otherwise unattainable geometric configurations, and dramatic simplification in manufacturing and assembly processes required for development of space plasma instruments.

Quetzal Larrick↗

Incipient fault detection study for advanced spacecraft systems

A feasibility study to investigate the application of vibration monitoring to the rotating machinery of planned NASA advanced spacecraft components is described. Factors investigated include: (1) special problems associated with small, high RPM machines; (2) application across multiple component types; (3) microgravity; (4) multiple fault types; (5) eight different analysis techniques including signature analysis, high frequency demodulation, cepstrum, clustering, amplitude analysis, and pattern recognition are compared; and (6) small sample statistical analysis is used to compare performance by computation of probability of detection and false alarm for an ensemble of repeated baseline and faulted tests. Both detection and classification performance are quantified. Vibration monitoring is shown to be an effective means of detecting the most important problem types for small, high RPM fans and pumps typical of those planned for the advanced spacecraft. A preliminary monitoring system design and implementation plan is presented.

Milner, G. Martin↗

Dual-Actuator Active Vibration-Control System

Dual-actuator active vibration-control (DAAVC) system is developmental system of type described in "Active Vibration Dampers for Rotating Machinery" (LEW-15427). System features sensors and actuators positioned and oriented at bearings to measure and counteract vibrations of shaft along either of two axes perpendicular to axis of rotation. Effective in damping vibrations of helicopter-engine test stand, making it safer to operate engine at speeds near and above first resonance of engine/test-stand system. Opens new opportunities for engine designers to draw more power from engine, and concept applicable to other rotating machines.

Kascak, Albert F.↗

Suppression of Subsynchronous Vibration in the SSME HPFTP

Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump (HPFTP) hot-fire dynamic data evaluation and rotordynamic analysis both confirm that two of the most significant turbopump attributes in determining susceptibility to subsynchronous vibration are impeller interstage seal configuration and rotor sideload resulting from turbine turnaround duct configuration and hot gas manifold. Recent hot-fire testing has provided promising indications that the incorporation of roughened damping seals at the impeller interstages may further increase the stability margin of this machine. A summary of the analysis which led to the conclusion that roughened seals would enhance the stability margin is presented along with a correlation of the analysis with recent test data.

Becht, David G.↗

Rotor internal friction instability

Two aspects of internal friction affecting stability of rotating machines are discussed. The first role of internal friction consists of decreasing the level of effective damping during rotor subsynchronous and backward precessional vibrations caused by some other instability mechanisms. The second role of internal frication consists of creating rotor instability, i.e., causing self-excited subsynchronous vibrations. Experimental test results document both of these aspects.

Bently, D. E.↗

Advanced Developments for Low Temperature Turbo-Brayton Cryocoolers

Turbo-Brayton cryocooler technology that has been space qualified and demonstrated on the NICMOS cryocooler is being adapted for applications with lower cooling loads at lower telqoeratures. The applications include sensor cooling for space platforms and telescopes at temperatures between 4 K and 35 K, where long life and reliable, vibration-free operation are important. This paper presents recent advances in the miniaturization of components that are critical to these systems. Key issues addressed in adapting the NICMOS cryocooler technology to lower temperatures involve reducing parasitic losses when scaling to smaller size machines. Recent advances include the successful design and testing of a small, permanent magnet driven compressor that operates at up to 10,000 rev/sec and the successful demonstration of self acting gas bearings supporting a I mm. diameter shaft. The compressor is important for cryocoolers with input powers between 50 W and 100 W. The miniature shaft and bearing system has applications in compressors and turbines at temperatures from 300 K to 6 K. These two technology milestones are fundamental to achieving exceptional thermodynamic performance from the turboBrayton system in low temperature systems. The paper discusses the development of these components and test results, and presents the implications of their performance on cryocooler systems.

Nellis, G. F.↗