Laser velocimeter data acquisition system for the Langley 14- by 22-foot subsonic tunnel. Software reference guide version 3.3

The Laser Velocimeter Data Acquisition System (LVDAS) in the Langley 14- by 22-Foot Tunnel is controlled by a comprehensive software package. The software package was designed to control the data acquisition process during wind tunnel tests which employ a laser velocimeter measurement system. This report provides detailed explanations on how to configure and operate the LVDAS system to acquire laser velocimeter and static wind tunnel data.

Jumper, Judith K.↗

Impeller flow field characterization with a laser two-focus velocimeter

Use of Computational Fluid Dynamics (CFD) codes, prevalent in the rocket engine turbomachinery industry, necessitates data of sufficient quality and quantity to benchmark computational codes. Existing data bases for typical rocket engine configurations, in particular impellers, are limited. In addition, traditional data acquisition methods have several limitations: typically transducer uncertainties are 0.5% of transducer full scale and traditional pressure probes are unable to provide flow characteristics in the circumferential (blade-to-blade) direction. Laser velocimetry circumvents these limitations by providing +0.5% uncertainty in flow velocity and +0.5% uncertainty in flow angle. The percent of uncertainty in flow velocity is based on the measured value, not full range capability. The laser electronics multiple partitioning capability allows data acquired between blades as the impeller rotates, to be analyzed separately, thus providing blade-to-blade flow characterization. Unlike some probes, the non-intrusive measurements made with the laser velocimeter does not disturb the flow. To this end,, and under Contract (NAS8-38864) to the National Aeronautics and Space Administration (NASA) at Marshall Space Flight Center (MSFC), an extensive test program was undertaken at Rocketdyne. Impellers from two different generic rocket engine pump configurations were examined. The impellers represent different spectrums of pump design: the Space Shuttle Main Engine (SSME) high pressure fuel turbopump (HPFTP) impeller was designed in the 1 1970's the Consortium for CFD application in Propulsion Technology Pump Stage Technology Team (Pump Consortium) optimized impeller was designed with the aid of modern computing techniques. The tester configuration for each of the impellers consisted of an axial inlet, an inducer, a diffuser, and a crossover discharge. While the tested configurations were carefully chosen to be representative of generic rocket engine pumps, several features of both testers were intentionally atypical. A crossover discharge, downstream of the impeller, rather than a volute discharge was used to minimize asymmetric flow conditions that might be reflected in the impeller discharge flow data. Impeller shroud wear ring radial clearances were purposely close to minimize leakage flow, thus increasing confidence in using the inlet data as an input to CFD programs. The empirical study extensively examined the flow fields of the two impellers via performance of laser two-focus velocimeter surveys in an axial plane upstream of the impellers and in multiple radial planes downstream of the impellers. Both studies were performed at the impeller design flow coefficients. Inlet laser surveys that provide CFD code inlet boundary conditions were performed in one axial plane, with ten radial locations surveyed. Three wall static pressures, positioned circumferentially around the impeller inlet, were used to identify asymmetrical pressure distributions in the inlet survey plane. The impeller discharge flow characterization consisted of three radial planes for the SSME HPFTP impeller and two radial planes for the Pump Consortium optimized impeller. Housing wall static pressures were placed to correspond to the radial locations surveyed with the laser velocimeter. Between five and thirteen axial stations across the discharge channel width were examined in each radial plane during the extensive flow mapping. The largely successful empirical flow characterization of two different impellers resulted in a substantial contribution to the limited existing data base, and yielded accurate data for CFD code benchmarking.

Brozowski, L. A.↗

Measurement of Leading Edge Vortices from a Delta Wing Using a Three Component Laser Velocimeter

A demonstration of the capabilities of a three component laser velocimeter to provide a detailed experimental database of a complex flow field i s presented. The orthogonal three component laser velocimeter was used to measure the leading edge vortex flow field above a 75 degrees delta wing at angles-of-attack of 20.5 degrees and 40.0 degrees. The resulting mean velocity and turbulence intensity measurements are presented. The laser velocimeter is described in detail including a description of the data processing algorithm. A full error analysis was conducted and the results presented.

Meyers, James F.↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser velocimeter for simultaneous two-dimensional velocity measurements

Laser velocimeter provides simultaneous orthogonal measurements in manner which minimizes many problems attending prior systems, and allows spatial traversing of flowfield in order to obtain velocity profiles. Velocimeter permits rapid interrogation of unsteady flows where area of interest is of the order of one meter in extent and flow does not vary appreciably over time of about one second.

Orloff, K. L.↗

Confocal backscatter laser velocimeter with on-axis sensitivity.

A confocal backscatter laser Doppler velocimeter (LDV) that measures two velocity components has been developed. This device requires only two incident beams polarized normally to one another. Moreover, the velocity components sensed are nearly orthogonal. The velocimeter employs a combined dual-scatter, local oscillator arrangement to obtain the bidirectional sensitivity. Two photodetectors are used, each sensing only one Doppler frequency proportional to one of the very nearly orthogonal velocity components. In addition, a single Bragg cell serves to frequency bias both velocity components in order to eliminate directional ambiguity. A differencing technique has also been incorporated to enhance the dual-scatter Doppler signal corresponding to the transverse velocity.

Orloff, K. L.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

A standard particle sizer-velocimeter

A standard particle sizer-cum-velocimeter is described, which was designed and built for the purpose of providing a standard source of aerosols of known size-distribution, moving with a known velocity, for the purpose of calibrating the continuous wave (CW) CO2-Laser Doppler Velocimeters at Marshall Space Flight Center. The instrument is designed with the capabilities of: (1) monitoring the size-distribution of particles of diameters larger than 1.0 microns; (2) measuring flow velocities in the range 0.05 - 100.0 cm/sec; (3) photographing particles of diameters above 0.2 microns moving at slow speeds (approximately 0.1 cm/sec); (4) measuring the size-distribution of particles settling in quiet air (or convection velocities of less than 0.15 cm/sec); and (5) use in the laboratory or in the field.

Deepak, A.↗

Laser velocimeter measurements of the helicopter rotor-induced flow field

The use of a two-color laser velocimeter to measure the flow velocities in the wake of a helicopter rotor is discussed, including methods for obtaining two components of both instantaneous and time-averaged velocities. Results are presented from an experiment using a 2.13 m diameter model helicopter rotor operating at a tip speed ratio of 0.18 in a wind tunnel. The location of the tip vortex from the preceding blade was determined on the advancing side, and the diameter of the vortex core was found to be 15 percent of the blade chord (1.5 percent of the radius). The effects of the airfoil's bound vorticity were observed in the velocity distributions vry near the blade. These effects suggest that the laser velocimeter may be used to determine the aerodynamic loading (circulation) at a spanwise station on the blade. Also, the structure and boundary of the time-averaged wake were investigated.

Biggers, J. C.↗

A feasibility test of the laser velocimeter in the Mach 5 nozzle test chamber

A one-component, fringe type laser velocimeter in the backscatter mode was used to measure flow velocities from 732 to 792 m/sec about a shock from an inclined flat plate in a Mach 5 tunnel. This test was chosen to determine system characteristics in applying the laser velocimeter to measure velocities in hypersonic flow fields. The seeding particles, less than 20 microns in diameter, were injected into the tunnel supply pipe, approximately 1 meter upstream of the nozzle throat, through a rake along the diameter. The LV signals were processed by two methods, a scanning spectrum analyzer and a high-speed counter. The measured velocity distributions obtained were analyzed to determine the errors due to particle lag, transit time broadening and high-speed counter quantizing error.

Meyers, J. F.↗

Investigating complex aerodynamic flows with a laser velocimeter

The paper discusses the application of the laser velocimeter in the study of two highly complex aerodynamic flows. In the first experiment, the laser velocimeter has been used with frequency tracking electronics to survey the multiple vortex wake structure behind a model of a large jet transport. The second application is to the study of the induced instantaneous inflow velocities near the blades of a model helicopter rotor; counter type processing was used in these measurements. In each experiment, the data output channels of these processors were handled in an on-line fashion, including both velocity computations and the plotting of fully reduced data.

Orloff, K. L.↗

Investigating complex aerodynamic flows with a laser velocimeter

The application of the laser velocimeter in the study of two highly complex aerodynamic flows is discussed. In the first experiment, the laser velocimeter was used with frequency tracking electronics to survey the multiple vortex wake structure behind a model of a large jet transport. The second application is to the study of the induced instantaneous inflow velocities near the blades of a model helicopter rotor; counter-type processing was used in these measurements. In each experiment, the data output channels of these processors were handled in an on-line fashion, including both velocity computations and the plotting of fully reduced data.

Orloff, K. L.↗

Laser velocimeter measurements in a large transonic wind tunnel

A two-component fringe type laser velocimeter operated in the backscatter mode was used to measure the free-stream velocity in an undisturbed flow field in a wind-tunnel test section from Mach 0.2 to Mach 1.0 and to measure the velocity along the stagnating streamline of a hemisphere model from Mach 0.2 to Mach 0.8. Burst signals from the laser velocimeter were processed by high-speed burst counters, and histograms of the number of occurrences of a particular counter output were collected by means of a pulse height analyzer. Arithmetic means of the histograms were calculated, and the results were compared with predicted local gas velocities with allowance for the lag of the scattering particles with respect to the gas flow. The free-stream measurements were accurate to within 2% of the calibration measurements. The stagnation streamline measurements show trends similar to theoretical predictions.

Meyers, J. F.↗

Limitations on the use of laser velocimeter signals for particle sizing

The paper discusses the complex relationship existing between the diameter of a particle, its index of refraction, and the output signal of a fringe-type laser velocimeter, and describes a special purpose laser velocimeter for aerosol sizing that determines aerosol size distributions on the basis of Farmer's (1973) relationship between visibility and particle size. In experiments with particles of known size, this relationship is in qualitative agreement with the experimentally observed results, the main differences being that (1) the visibility does not assume a minimum value of zero, as predicted, and (2) the visibility value above which there is no ambiguity in the corresponding fringe spacing is higher than that predicted.

Orloff, K. L.↗

Modular high accuracy tracker for dual channel laser Doppler velocimeter

In the study described, a scanning dual-channel cross-beam laser Doppler velocimeter (developed for measuring simultaneously the two orthogonal components of flow velocity and turbulence intensity) was used to measure the instantaneous velocity characteristics of a model helicopter rotor and in a vortex wake survey experiment on a Boeing 747 aircraft model. Particular attention is given to a special purpose dual-loop frequency tracker developed to track and demodulate 10 microsecond wide pulse burst Doppler signals with a study cycle of 25% (or narrower signals at a higher duty cycle) generated by the laser Doppler velocimeter.

Fridman, J. D.↗

"Pseudobackscatter" laser velocimeter

Laser instrument measures speed of fluid flow with sensitivity of forward-scatter velocimeter and convenience of back scatter device. Velocimeter uses corner-cube reflector to return scattered laser beam to source. Device measures airflow around aircraft and in wind tunnels or other fluid-flow measurement applications.

Gunther, W. D.↗

Miniature velocimeter

Laser velocimeter (LV) designed to use semiconductor-diode laser is 100 times smaller than continuous-wave gas-laser velocimeter permitting mounting within wind-tunnel models or on engine walls. Mini LV uses only 0.4 watts of power and measures velocities with accuracy of 98% or better.

Franke, J. M.↗