Rugged Video System For Inspecting Animal Burrows

Video system designed for examining interiors of burrows of gopher tortoises, 5 in. (13 cm) in diameter or greater, to depth of 18 ft. (about 5.5 m), includes video camera, video cassette recorder (VCR), television monitor, control unit, and power supply, all carried in backpack. Polyvinyl chloride (PVC) poles used to maneuver camera into (and out of) burrows, stiff enough to push camera into burrow, but flexible enough to bend around curves. Adult tortoises and other burrow inhabitants observable, young tortoises and such small animals as mice obscured by sand or debris.

Triandafils, Dick↗

Evaluation of lens distortion errors in video-based motion analysis

In an effort to study lens distortion errors, a grid of points of known dimensions was constructed and videotaped using a standard and a wide-angle lens. Recorded images were played back on a VCR and stored on a personal computer. Using these stored images, two experiments were conducted. Errors were calculated as the difference in distance from the known coordinates of the points to the calculated coordinates. The purposes of this project were as follows: (1) to develop the methodology to evaluate errors introduced by lens distortion; (2) to quantify and compare errors introduced by use of both a 'standard' and a wide-angle lens; (3) to investigate techniques to minimize lens-induced errors; and (4) to determine the most effective use of calibration points when using a wide-angle lens with a significant amount of distortion. It was seen that when using a wide-angle lens, errors from lens distortion could be as high as 10 percent of the size of the entire field of view. Even with a standard lens, there was a small amount of lens distortion. It was also found that the choice of calibration points influenced the lens distortion error. By properly selecting the calibration points and avoidance of the outermost regions of a wide-angle lens, the error from lens distortion can be kept below approximately 0.5 percent with a standard lens and 1.5 percent with a wide-angle lens.

Poliner, Jeffrey↗

Issues for bringing digital libraries into public use

In much the same way that the field of artificial intelligence produced a cult which fervently believed that computers would soon think like human beings, the existence of electronic books has resurrected the paperless society as a utopian vision to some, an apocalyptic horror to others. In this essay we have attempted to provide realistic notions of what digital libraries are likely to become if they are a popular success. E-books are capable of subsuming most of the media we use today and have the potential for added functionality by being interactive. The environmental impact of having millions more computers will be offset to some degree, perhaps even exceeded, by the fact that televisions, stereos, VCR's, CD players, newspapers, magazines, and books will become part of the computer system or be made redundant. On the whole, large-scale use of digital libraries is likely to be a winning proposition. Whether or not this comes to pass depends on the directions taken by today's researchers and software developers. By involving the public, the effort being put into digital libraries can be leveraged into something which is big enough to make a real change for the better. If digital libraries remain the exclusive property of government, universities, and large research firms, then large parts of the world will remain without digital libraries for years to come, just as they have remained without digital phone service for far too long. If software companies try to scuttle the project by patenting crucial algorithms and using proprietary data formats, all of us will suffer. Let us reverse the errors of the past and create a truly open digital library system.

Flater, David W.↗

Evaluation of lens distortion errors using an underwater camera system for video-based motion analysis

Video-based motion analysis systems are widely employed to study human movement, using computers to capture, store, process, and analyze video data. This data can be collected in any environment where cameras can be located. One of the NASA facilities where human performance research is conducted is the Weightless Environment Training Facility (WETF), a pool of water which simulates zero-gravity with neutral buoyance. Underwater video collection in the WETF poses some unique problems. This project evaluates the error caused by the lens distortion of the WETF cameras. A grid of points of known dimensions was constructed and videotaped using a video vault underwater system. Recorded images were played back on a VCR and a personal computer grabbed and stored the images on disk. These images were then digitized to give calculated coordinates for the grid points. Errors were calculated as the distance from the known coordinates of the points to the calculated coordinates. It was demonstrated that errors from lens distortion could be as high as 8 percent. By avoiding the outermost regions of a wide-angle lens, the error can be kept smaller.

Poliner, Jeffrey↗

Far ultraviolet spectral measurements of the diffuse astronomical background

Diffuse astrophysical emission at wavelengths between 900 and 1200 A (FUV(sub 900-1200 A)) contains unique information about the nature and extent of the poorly understood hot phase of the interstellar medium. Observations of the diffuse background emission in this bandpass are fraught with difficulty, and previous measurements have provided only upper limits to this flux. The data discussed in this paper were obtained with the Far Ultraviolet Coronal Rocket (FU-VCR), which had important advantages over previous instruments: intense geocoronal emission was rejected, eliminating potentially overwhelming contamination of the data; the data were spectroscopic with resolution sufficient for robust modeling of both astrophysical and instrumental data components; and point sources were imaged, allowing for the elimination of these critical contamination sources. The superior quality of these data permits the determination of new bounds to the physical properties of the hot interstellar medium.

Edelstein, J.↗

Active Flow Control: Instrumentation Automation and Experimental Technique

In investigating the potential of a new actuator for use in an active flow control system, several objectives had to be accomplished, the largest of which was the experimental setup. The work was conducted at the NASA Langley 20x28 Shear Flow Control Tunnel. The actuator named Thunder, is a high deflection piezo device recently developed at Langley Research Center. This research involved setting up the instrumentation, the lighting, the smoke, and the recording devices. The instrumentation was automated by means of a Power Macintosh running LabVIEW, a graphical instrumentation package developed by National Instruments. Routines were written to allow the tunnel conditions to be determined at a given instant at the push of a button. This included determination of tunnel pressures, speed, density, temperature, and viscosity. Other aspects of the experimental equipment included the set up of a CCD video camera with a video frame grabber, monitor, and VCR to capture the motion. A strobe light was used to highlight the smoke that was used to visualize the flow. Additional effort was put into creating a scale drawing of another tunnel on site and a limited literature search in the area of active flow control.

Gimbert, N. Wes↗

Context-Specific Adaptation of Gravity-Dependent Vestibular Reflex Responses (NSBRI Neurovestibular Project 1)

Impairment of gaze and head stabilization reflexes can lead to disorientation and reduced performance in sensorimotor tasks such as piloting of spacecraft. Transitions between different gravitoinertial force (gif) environments - as during different phases of space flight - provide an extreme test of the adaptive capabilities of these mechanisms. We wish to determine to what extent the sensorimotor skills acquired in one gravity environment will transfer to others, and to what extent gravity serves as a context cue for inhibiting such transfer. We use the general approach of adapting a response (saccades, vestibuloocular reflex: VOR, or vestibulocollic reflex: VCR) to a particular change in gain or phase in one gif condition, adapting to a different gain or phase in a second gif condition, and then seeing if gif itself - the context cue - can recall the previously-learned adapted responses. Previous evidence indicates that unless there is specific training to induce context-specificity, reflex adaptation is sequential rather than simultaneous. Various experiments in this project investigate the behavioral properties, neurophysiological basis, and anatomical substrate of context-specific learning, using otolith (gravity) signals as a context cue. In the following, we outline the methods for all experiments in this project, and provide details and results on selected experiments.

Shelhamer, Mark↗

Formal Verification of a Power Controller Using the Real-Time Model Checker UPPAAL

A real-time system for power-down control in audio/video components is modeled and verified using the real-time model checker UPPAAL. The system is supposed to reside in an audio/video component and control (read from and write to) links to neighbor audio/video components such as TV, VCR and remote-control. In particular, the system is responsible for the powering up and down of the component in between the arrival of data, and in order to do so in a safe way without loss of data, it is essential that no link interrupts are lost. Hence, a component system is a multitasking system with hard real-time requirements, and we present techniques for modeling time consumption in such a multitasked, prioritized system. The work has been carried out in a collaboration between Aalborg University and the audio/video company B&O. By modeling the system, 3 design errors were identified and corrected, and the following verification confirmed the validity of the design but also revealed the necessity for an upper limit of the interrupt frequency. The resulting design has been implemented and it is going to be incorporated as part of a new product line.

Havelund, Klaus↗

Subcooled Pool Boiling Heat Transfer Mechanisms in Microgravity: Terrier-improved Orion Sounding Rocket Experiment

A microscale heater array was used to study boiling in earth gravity and microgravity. The heater array consisted of 96 serpentine heaters on a quartz substrate. Each heater was 0.27 square millimeters. Electronic feedback loops kept each heater's temperature at a specified value. The University of Maryland constructed an experiment for the Terrier-Improved Orion sounding rocket that was delivered to NASA Wallops and flown. About 200 s of high quality microgravity and heat transfer data were obtained. The VCR malfunctioned, and no video was acquired. Subsequently, the test package was redesigned to fly on the KC-135 to obtain both data and video. The pressure was held at atmospheric pressure and the bulk temperature was about 20 C. The wall temperature was varied from 85 to 65 C. Results show that gravity has little effect on boiling heat transfer at wall superheats below 25 C, despite vast differences in bubble behavior between gravity levels. In microgravity, a large primary bubble was surrounded by smaller bubbles, which eventually merged with the primary bubble. This bubble was formed by smaller bubbles coalescing, but had a constant size for a given superheat, indicating a balance between evaporation at the base and condensation on the cap. Most of the heaters under the bubble indicated low heat transfer, suggesting dryout at those heaters. High heat transfer occurred at the contact line surrounding the primary bubble. Marangoni convection formed a "jet" of fluid into the bulk fluid that forced the bubble onto the heater.

Kim, Jungho↗

Getting the Bigger Picture With Digital Surveillance

Through a Space Act Agreement, Diebold, Inc., acquired the exclusive rights to Glenn Research Center's patented video observation technology, originally designed to accelerate video image analysis for various ongoing and future space applications. Diebold implemented the technology into its AccuTrack digital, color video recorder, a state-of- the-art surveillance product that uses motion detection for around-the- clock monitoring. AccuTrack captures digitally signed images and transaction data in real-time. This process replaces the onerous tasks involved in operating a VCR-based surveillance system, and subsequently eliminates the need for central viewing and tape archiving locations altogether. AccuTrack can monitor an entire bank facility, including four automated teller machines, multiple teller lines, and new account areas, all from one central location.

Source record↗

Vestibular compensation and orientation during locomotion

Body, head, and eye movements were studied in three dimensions while walking and turning to determine the role of the vestibular system in directing gaze and maintaining spatial orientation. The body, head, and eyes were represented as three-dimensional coordinate frames, and the movement of these frames was related to a trajectory frame that described the motion of the body on a terrestrial plane. The axis-angle of the body, head, and eye rotation were then compared to the axis-angle of the rotation of the gravitoinertial acceleration (GIA). We inferred the role of the vestibular system during locomotion and the contributions of the VCR and VOR by examining the interrelationship between these coordinate frames. Straight walking induced head and eye rotations in a compensatory manner to the linear accelerations, maintaining head pointing and gaze along the direction of forward motion. Turning generated a combination of compensation and orientation responses. The head leads and steers the turn while the eyes compensate to maintain stable horizontal gaze in space. Saccades shift horizontal gaze as the turn is executed. The head pitches, as during straight walking. It also rolls so that the head tends to align with the orientation of the GIA. Head orientation changes anticipate orientation changes of the GIA. Eye orientation follows the changes in GIA orientation so that the net orientation gaze is closer to the orientation of the GIA. The study indicates that the vestibular system utilizes compensatory and orienting mechanisms to stabilize spatial orientation and gaze during walking and turning.

Non-NASA Center↗

Stabilization of gaze during circular locomotion in darkness. II. Contribution of velocity storage to compensatory eye and head nystagmus in the running monkey

1. Yaw eye in head (Eh) and head on body velocities (Hb) were measured in two monkeys that ran around the perimeter of a circular platform in darkness. The platform was stationary or could be counterrotated to reduce body velocity in space (Bs) while increasing gait velocity on the platform (Bp). The animals were also rotated while seated in a primate chair at eccentric locations to provide linear and angular accelerations similar to those experienced while running. 2. Both animals had head and eye nystagmus while running in darkness during which slow phase gaze velocity on the body (Gb) partially compensated for body velocity in space (Bs). The eyes, driven by the vestibuloocular reflex (VOR), supplied high-frequency characteristics, bringing Gb up to compensatory levels at the beginning and end of the slow phases. The head provided substantial gaze compensation during the slow phases, probably through the vestibulocollic reflex (VCR). Synchronous eye and head quick phases moved gaze in the direction of running. Head movements occurred consistently only when animals were running. This indicates that active body and limb motion may be essential for inducing the head-eye gaze synergy. 3. Gaze compensation was good when running in both directions in one animal and in one direction in the other animal. The animals had long VOR time constants in these directions. The VOR time constant was short to one side in one animal, and it had poor gaze compensation in this direction. Postlocomotory nystagmus was weaker after running in directions with a long VOR time constant than when the animals were passively rotated in darkness. We infer that velocity storage in the vestibular system had been activated to produce continuous Eh and Hb during running and to counteract postrotatory afterresponses. 4. Continuous compensatory gaze nystagmus was not produced by passive eccentric rotation with the head stabilized or free. This indicates that an aspect of active locomotion, most likely somatosensory feedback, was responsible for activating velocity storage. 5. Nystagmus was compared when an animal ran in darkness and in light. the beat frequency of eye and head nystagmus was lower, and the quick phases were larger in darkness. The duration of head and eye quick phases covaried. Eye quick phases were larger when animals ran in darkness than when they were passively rotated. The maximum velocity and duration of eye quick phases were the same in both conditions. 6. The platform was counterrotated under one monkey in darkness while it ran in the direction of its long vestibular time constant.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Synchronization of video recording and laser pulses including background light suppression

An apparatus for and a method of triggering a pulsed light source, in particular a laser light source, for predictable capture of the source by video equipment. A frame synchronization signal is derived from the video signal of a camera to trigger the laser and position the resulting laser light pulse in the appropriate field of the video frame and during the opening of the electronic shutter, if such shutter is included in the camera. Positioning of the laser pulse in the proper video field allows, after recording, for the viewing of the laser light image with a video monitor using the pause mode on a standard cassette-type VCR. This invention also allows for fine positioning of the laser pulse to fall within the electronic shutter opening. For cameras with externally controllable electronic shutters, the invention provides for background light suppression by increasing shutter speed during the frame in which the laser light image is captured. This results in the laser light appearing in one frame in which the background scene is suppressed with the laser light being uneffected, while in all other frames, the shutter speed is slower, allowing for the normal recording of the background scene. This invention also allows for arbitrary (manual or external) triggering of the laser with full video synchronization and background light suppression.

Kalshoven, Jr., James E.↗

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management↗

Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

Mechanically connected fluid joints are virtually unavoidable in complex cryogenic system designs. In the case of spacecraft, the performance of these joints is critical to mission success. This is especially true for long-duration space missions where even very low leak rates can eventually lead to significant propellant losses or failure of vital cryogenic cooling systems. NASA has recently undertaken an effort to quantify the leak rate of Vacuum Coupling Radiation (VCR) fittings over the temperature range from ambient to 20 K, both before and after exposure to a launch vibration profile. A test apparatus employing a cryocooler and a calibrated helium mass spectrometer was developed, validated, and used to obtain quantifiable leak rates at a fitting test pressure of 31 bar (450 psig). Three different fitting sizes were tested, 25.4 mm (¼ inch), 12.7 mm (½ inch), and 6.35 mm (1 inch) and two gasket materials, stainless steel, and silver-plated nickel. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles/measurement tests, followed by a launch vibration test profile at ambient temperature, and then two additional cryogenic thermal cycles/measurement tests. The design and development of the test apparatus, and test data are presented and discussed in detail.

G J Tamasy↗