Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAPORIZATION HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Potassium Rankine cycle vapor chamber (heat pipe) radiator study

A structurally integrated vapor chamber fin (heat pipe) radiator is defined and evaluated as a potential candidate for rejecting waste heat from the potassium Rankine cycle powerplant. Several vapor chamber fin geometries, using stainless steel construction, are evaluated and an optimum is selected. A comparison is made with an operationally equivalent conduction fin radiator. Both radiators employ NaK-78 in the primary coolant loop. In addition, the Vapor Chamber Fin (VCF) radiator utilizes sodium in the vapor chambers. Preliminary designs are developed for the conduction fin and VCF concepts. Performance tests on a single vapor chamber were conducted to verify the VCF design. A comparison shows the conduction fin radiator easier to fabricate, but heavier in weight, particularly as meteoroid protection requirements become more stringent. While the analysis was performed assuming the potassium Rankine cycle powerplant, the results are equally applicable to any system radiating heat to space in the 900 to 1400 F temperature range.

Gerrels, E. E.↗

Measurement of Heat of Vaporization for Research Gasolines and Ethanol Blends by DSC/TGA

The heat of vaporization (HOV) is a relatively poorly studied fuel property that can be related to a fuel's evaporation characteristics and knock resistance and, therefore, the emissions and efficiency of direct-injection spark-ignition engines. Methods for measuring the HOV of complex gasoline mixtures and blends of gasoline with ethanol and other oxygenates require additional development. Recently, we described a differential scanning calorimetry/thermogravimetric (DSC/TGA) method to perform HOV measurements. Herein we describe a detailed investigation of factors affecting the precision and accuracy of the DSC/TGA method and examine enthalpy evolution and mass loss rate for research gasolines as a function of fraction evaporated. Examination of n-hexane evaporation using several DSC/TGA pan/lid configurations showed that initial sample loss can be reduced using a well-fitting pinhole lid on the sample pan, which reduces the evaporation rate during the balance of the experiment. However, additional experiments with research gasolines revealed that tight lid placement on the pans is not always achieved. Nevertheless, accurate total HOV measurements, with less than 10% initial sample loss, could be achieved for low volatility gasolines regardless of lid placement. A higher mass loss might be expected for higher vapor pressure (wintertime) gasolines. Because of variations in pan lids and their placement and their significant impact on results, quantitative comparisons between different samples of mass loss rate and heat flow curves versus time or fraction evaporated are not yet possible. However, features in the mass loss rate and heat flow curves are reproducible. Furthermore, results show that ethanol-gasoline blend evaporation is highly influenced by the formation of near-azeotropic mixtures of ethanol and specific gasoline components, causing a flattening of the mass and heat curves, with a sharp evaporation rate reduction after the ethanol is evaporated.

33 ADVANCED PROPULSION SYSTEMS↗

Vapor-modulated heat pipe for improved temperature control

Dryout induced by vapor throttling makes control of equipment temperature less dependent on variations in sink environment. Mechanism controls flow of vapor in heat pipe by using valve in return path to build difference in pressure and also difference in saturation temperature of the vapor. In steady state, valve closes just enough to produce partial dryout that achieves required temperature drop.

Edwards, D. K.↗

Heat of Vaporization and Species Evolution Suring Gasoline Evaporation Measured by DSC/TGA/MS for Blends of C1 to C4 Alcohols in Commercial Gasoline Blendstocks

Evaporative cooling of the fuel-air charge by fuel evaporation is an important feature of direct-injection spark-ignition engines that improves fuel knock resistance and reduces pumping losses at intermediate load, but in some cases, may increase fine particle emissions. We have reported on experimental approaches for measuring both total heat of vaporization and examination of the evaporative heat effect as a function of fraction evaporated for gasolines and ethanol blends. In this paper, we extend this work to include other low-molecular-weight alcohols and present results on species evolution during fuel evaporation by coupling a mass spectrometer to our differential scanning calorimetry/thermogravimetric analysis instrument. The alcohols examined were methanol, ethanol, 1-propanol, isopropanol, 2-butanol, and isobutanol at 10 volume percent, 20 volume percent, and 30 volume percent. The results show that total heat of vaporization of the alcohol gasoline blends is in line with the decreasing heat of vaporization in kilojoules per kilogram with increasing alcohol carbon number, as expected. Mass spectrometer results show that methanol fully evaporates at significantly lower fraction evaporated relative to other alcohols even though it is present at higher molar concentration at a fixed volumetric concentration. Certain alcohols, especially methanol and ethanol, can suppress the evaporation of aromatic compounds such as cumene during the evaporation process in some samples. While the use of mass spectrometry to analyze the composition of the evolving gas mixture provided useful results for a relatively simple research gasoline (FACE B), additional research is required to practically apply this methodology to more complex commercial gasolines.

30 DIRECT ENERGY CONVERSION↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Model-based compositional predictions for a differential scanning calorimetry/thermogravimetric analysis-mass spectrometry system used for heat of vaporization measurements

A Differential Scanning Calorimetry/Thermogravimetric Analysis (DSC/TGA) procedure for determination of Heat of Vaporization (HOV) of fuel and surrogate fuel mixtures has been previously utilized for evaluation of oxygenate impacts on spark ignition fuels. This analysis has been further leveraged with mass spectrometry (MS) to elucidate vapor phase compositional changes during evaporation. In this study we focus on a simple system of three compounds (ethanol, n-hexane, and n-octane) to provide a model-based understanding of the evaporation process under these experimental conditions. An Aspen Plus model was set up to provide liquid and vapor phase concentration predictions during mixture evaporation using the initial mixture composition, and measured temperature and mass loss profiles from DSC/TGA experiments. Agreements between the trends of the MS ion count profiles and model composition predictions provide a degree of validation of this modeling approach that can allow the interpretation and extrapolation of DSC/TGA measurements for more complex fuel mixtures.

33 ADVANCED PROPULSION SYSTEMS↗

Senstitivity analysis of horizontal heat and vapor transfer coefficients for a cloud-topped marine boundary layer during cold-air outbreaks

The effects of external parameters on the surface heat and vapor fluxes into the marine atmospheric boundary layer (MABL) during cold-air outbreaks are investigated using the numerical model of Stage and Businger (1981a). These fluxes are nondimensionalized using the horizontal heat (g1) and vapor (g2) transfer coefficient method first suggested by Chou and Atlas (1982) and further formulated by Stage (1983a). In order to simplify the problem, the boundary layer is assumed to be well mixed and horizontally homogeneous, and to have linear shoreline soundings of equivalent potential temperature and mixing ratio. Modifications of initial surface flux estimates, time step limitation, and termination conditions are made to the MABL model to obtain accurate computations. The dependence of g1 and g2 in the cloud topped boundary layer on the external parameters (wind speed, divergence, sea surface temperature, radiative sky temperature, cloud top radiation cooling, and initial shoreline soundings of temperature, and mixing ratio) is studied by a sensitivity analysis, which shows that the uncertainties of horizontal transfer coefficients caused by changes in the parameters are reasonably small.

Chang, Y. V.↗

An improved algorithm for the modeling of vapor flow in heat pipes

A heat pipe vapor flow algorithm suitable for use in codes on microcomputers is presented. The incompressible heat pipe vapor flow studies of Busse are extended to incorporate compressibility effects. The Busse velocity profile factor is treated as a function of temperature and pressure. The assumption of a uniform saturated vapor temperature determined by the local pressure at each cross section of the pipe is not made. Instead, a mean vapor temperature, defined by an energy integral, is determined in the course of the solution in addition to the pressure, saturation temperature at the wall, and the Busse velocity profile factor. For alkali metal working fluids, local species equilibrium is assumed. Temperature and pressure profiles are presented for several cases involving sodium heat pipes. An example for a heat pipe with an adiabatic section and two evaporators in sequence illustrates the ability to handle axially varying heat input. A sonic limit plot for a short evaporator falls between curves for the Busse and Levy inviscid sonic limits.

Tower, Leonard K.↗

Method and apparatus for vapor detection

The method disclosed herein may be practiced by passing the vapors to be sampled along a path with halogen vapor, preferably chlorine vapor, heating the mixed vapors to halogenate those of the sampled vapors subject to halogenation, removing unreacted halogen vapor, and then sensing the vapors for organic halogenated compounds. The apparatus disclosed herein comprises means for flowing the vapors, both sample and halogen vapors, into a common path, means for heating the mixed vapors to effect the halogenation reaction, means for removing unreacted halogen vapor, and a sensing device for sensing halogenated compounds. By such a method and means, the vapors of low molecular weight hydrocarbons, ketones and alcohols, when present, such as methane, ethane, acetone, ethanol, and the like are converted, at least in part, to halogenated compounds, then the excess halogen removed or trapped, and the resultant vapors of the halogenated compounds sensed or detected. The system is highly sensitive. For example, acetone in a concentration of 30 parts per billion (volume) is readily detected.

Lerner, Melvin↗

Multilead, Vaporization-Cooled Soldering Heat Sink

Vaporization-cooled heat sink proposed for use during soldering of multiple electrical leads of packaged electronic devices to circuit boards. Heat sink includes compliant wicks held in grooves on edges of metal fixture. Wicks saturated with water. Prevents excessive increases in temperature at entrances of leads into package.

Rice, John↗

Effects of Heat of Vaporization and Octane Sensitivity on Knock-Limited Spark Ignition Engine Performance

Knock-limited loads for a set of surrogate gasolines all having nominal 100 research octane number (RON), approximately 11 octane sensitivity (S), and a heat of vaporization (HOV) range of 390 to 595 kJ/kg at 25 degrees C were investigated. A single-cylinder spark-ignition engine derived from a General Motors Ecotec direct injection (DI) engine was used to perform load sweeps at a fixed intake air temperature (IAT) of 50 degrees C, as well as knock-limited load measurements across a range of IATs up to 90 degrees C. Both DI and pre-vaporized fuel (supplied by a fuel injector mounted far upstream of the intake valves and heated intake runner walls) experiments were performed to separate the chemical and thermal effects of the fuels' knock resistance. The DI load sweeps at 50 degrees C intake air temperature showed no effect of HOV on the knock-limited performance. The data suggest that HOV acts as a thermal contributor to S under the conditions studied. Measurement of knock-limited loads from the IAT sweeps for DI at late combustion phasing showed that a 40 vol% ethanol (E40) blend provided additional knock resistance at the highest temperatures, compared to a 20 vol% ethanol blend and hydrocarbon fuel with similar RON and S. Using the pre-vaporized fuel system, all the high S fuels produced nearly identical knock-limited loads at each temperature across the range of IATs studied. For these fuels RON ranged from 99.2 to 101.1 and S ranged from 9.4 to 12.2, with E40 having the lowest RON and highest S. The higher knock-limited loads for E40 at the highest IATs examined were consistent with the slightly higher S for this fuel, and the lower engine operating condition K values arising from use of this fuel. The study highlights how fuel HOV can affect the temperature at intake valve closing, and consequently the pressure-temperature history of the end gas leading to more negative values of K, thereby enhancing the effect of S on knock resistance.

33 ADVANCED PROPULSION SYSTEMS↗

Vapor-Resistant Heat-Pipe Artery

Vapor lock in heat pipe delayed or prevented. Modifications of wick prevent flow of vapor into, or formation of vapor in, liquid-return artery. Small pores of fine-grained sintered wick help to prevent formation of large bubbles. Slotted tube offers few nucleation sites for bubbles. Improves return of liquid in heat pipe.

Dussinger, Peter M.↗

The Condensation Line of Air and the Heats of Vaporization of Oxygen and Nitrogen

The condensation pressure of air was determined over the range of temperature from 60 to 85 K. The experimental results were slightly higher than the calculated values based on the ideal solution law. Heat of vaporization of oxygen was determined at four temperatures ranging from about 68 to 91 K and of nitrogen similarly at four temperatures ranging from 62 to 78 K.

GASES, THERMODYNAMIC - PROPERTIES↗

Flue Gas Water Vapor Latent Heat Recovery for Pressurized Oxy-Combustion

This final report presents the results of a three-year technology development project carried out by a team of participants sponsored by the Department of Energy (DOE). This is addressing the FOA Area of Interest 2: Enabling Combustion Technology. Specifically, the technology targets for flue gas water vapor latent heat recovery from pressurized oxy-coal combustion power plants. A pilot scale Transport Membrane Condenser (TMC) system has been developed, fabricated, integrated, and performance-tested in a pressurized oxy-coal pilot-scale combustion system to prove its effectiveness. We have evaluated its performance and analyzed the results for application to commercial-scale power plants. We expect the same technology to be also applicable to pressurized chemical looping combustion (CLC) flue gas, which has similar conditions.

01 COAL, LIGNITE, AND PEAT↗

Excess liquid in heat-pipe vapor spaces

A mathematical model is developed of excess liquid in heat pipes that is used to calculate the parameters governing the axial flow of liquid in fillets and puddles that form in vapor spaces. In an acceleration field, the hydrostatic pressure variation is taken into account, which results in noncircular meniscus shapes. The two specific vapor-space geometries considered are circular and the 'Dee-shape' that is formed by a slab wick in a circular tube. Also presented are theoretical and experimental results for the conditions under which liquid slugs form at the ends of the vapor spaces. These results also apply to the priming of arteries.

Eninger, J. E.↗

Forced convection heat transfer to air/water vapor mixtures

Heat transfer coefficients were measured using both dry air and air/water vapor mixtures in the same forced convection cooling test rig (jet array impingement configurations) with mass ratios of water vapor to air up to 0.23. The primary objective was to verify by direct experiment that selected existing methods for evaluation of viscosity and thermal conductivity of air/water vapor mixtures could be used with confidence to predict heat transfer coefficients for such mixtures using as a basis heat transfer data for dry air only. The property evaluation methods deemed most appropriate require as a basis a measured property value at one mixture composition in addition to the property values for the pure components.

Richards, D. R.↗

The liquid-conduction, vapor-flow heat pipe model in Sockeye

A single-phase heat pipe flow model implemented in the heat pipe application Sockeye is described. This model solves one-dimensional, compressible flow equations for the vapor phase in the center of a heat pipe, which are coupled to the two-dimensional heat conduction equation for the wick, liquid, and cladding, as well as to an ordinary differential equation tracking the working fluid inventory in the evaporator section of the heat pipe. This model is demonstrated with several test problems, including comparisons to analytic solutions for the vapor flow fields, analytic curves for sonic and capillary limitations of heat pipe operation, and some experimental data. The numerical solution gives excellent agreement for verification problems and good agreement with experimental results. Also, demonstrations show that the model is very robust, allowing for full simulations of heat pipe transients, including frozen startup, sonic-limited (supersonic) flow, and heat pipe shutdown.

42 ENGINEERING↗