Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VACUUM SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A spectrograph for the far-ultraviolet.

Vacuum type lensless spectrograph in intermediate and far UV for evaluating shock compressed metals resulting from hypervelocity impact

ULTRAVIOLET SPECTROGRAPH↗

The sublimation kinetics of GeSe single crystals

The sublimation kinetics of (001) oriented GeSe single crystal platelets was studied by high-temperature mass spectroscopy, quantitative vacuum microbalance techniques, and hot stage optical microscopy. For a mean experimental temperature of 563 K, the activation enthalpy and entropy are found to equal 32.3 kcal/mole and 19.1 eu, respectively. The vaporization coefficient is less than unity for the range of test temperatures, and decreases with increasing temperature. The combined experimental data are correlated by means of a multistep surface adsorption mechanism.

Irene, E. A.↗

Spectral emission of nuclear excited XeBr*

The vacuum-ultraviolet spectroscopy system and MCFIG capsule were filled with a He-3:Ar:Xe:Br (534:195:12:6) torr mixture and irradiatied by a CW flux of 17 x 10 to the 11th power neutrons/sq cm sec. The XeBr* emission was observed, but the Br2 emission normally observed in argon-bromine mixtures predominates. This spectrum is typical of these mixtures with XeBr* probably peaking with 0.1 percent Bromine in 2 atmosphere argon with 2 percent xenon. The addition of a large partial pressure of He-3 produces additional unknowns. The typical vibrational structure of XeBr* was not observed. Sapphire emission continuums were present. Energy deposition was 0.43 watts and the capsule output under the XeBr* and Br2 bands was 0.0016 watts, giving an efficiency of 0.37 percent.

Walters, R. A.↗

Water ice polymorphs and their significance on planetary surfaces

Impacts into an icy surface could produce significant amounts of high pressure forms of water ice. Due to the relatively low ambient surface temperatures on satellites in the outer solar system and the modest temperature rises accompanying the impact pressures required for water ice metamorphism, high-pressure polymorphs will be created by and may remain after large cratering events. If so, those high-pressure ices should be ubiquitous. Low-pressure cubic ice may be abundant as well. Impacts into an icy regolith may both produce high-pressure polymorphs from ice I and destroy high-pressure polymorphs already present. The result will be an (unknown) equilibrium concentration of high pressure polymorphs in the regolith. Polymorphs may be detectable and mappable by reflection spectroscopy at vacuum ultraviolet and mid-infrared wavelengths.

Gaffney, E. S.↗

Fabrication of an electron multiplier utilizing diamond films

High secondary electron yields (sigma=14-27) from polycrystalline diamond films on Mo substrates have been reported previously. We observed that continuous exposure to an electron beam degraded the secondary yield in vacuum as a function of fluence owing to a loss of surface hydrogen. However, the hydrogen partial pressure could be adjusted such that the high secondary yield remained stable during beam exposure. We have constructed a prototype electron multiplier using these diamond films for use in ultrahigh vacuum. A gain of 0.9 times 10(exp 5) has been measured in a d.c. mode. Palladium, titanium and aluminum nitride have been studied for possible dynode substrate materials which might eliminate the need for hydrogen during operation. Total secondary yields as high as 50 were measured from diamond on palladium and sigma was stable at 25 during heating at 700 K in vacuum. Raman spectroscopy and scanning electron microscopy showed that variations in sigma from diamond films on Pd were due to differing concentrations of non-diamond carbon.

Mearini, G. T.↗

Ultraviolet spectroscopy of comae

Vacuum ultraviolet observations from sounding rockets and satellite observatories of the gaseous comae of several recent comets are reviewed. The earliest of these led to discovery of the hydrogen envelope extending for millions of km from the nucleus. Subsequent observations of H I Lyman alpha, the OH (0,0) band and the oxygen resonance triplet have provided strong evidence for the water-ice model of the cometary nucleus. Several new species were discovered in the coma, including C, C(+), CO, S and CS. High-resolution spectroscopy and the spatial variation of the observed emissions provide means to elucidate the production and excitation mechanisms of these species. The similarity of the spectra of the half-dozen comets observed to date argues for a common, homogeneous composition (with the exception of dust and CO) of the cometary ice and a minimal effect on the neutral species due to molecular collisions in the inner coma.

Feldman, P. D.↗

Spatial Heterodyne Spectroscopy - Laboratory tests of field widened, multiple order, and vacuum ultraviolet systems

We describe a new instrumental technique for interference spectroscopy, Spatial Heterodyne Spectroscopy (SHS), which promises to extend into the FUV (1200 A - 2000 A) spectral region the large throughput advantage at high spectral resolution usually associated with Fabry-Perot and Michelson interferometers. In addition, SHS systems are compact in size, can be field-widened to increase their throughput advantage even further, and have no moving parts. SHS appears to be well suited for high resolution, space-based spectroscopy of faint interstellar emission lines in the FUV. In this paper we review the first proof-of-concept laboratory demonstrations of a field widened SHS configuration and a multiple order SHS system, which extends the spectral range of the basic device and present new results of SHS performance in the VUV. The design of an SHS system capable of obtaining velocity resolved spectra of the CIV 1550 doublet from the interstellar medium is also discussed.

Harlander, J.↗

Metallic transfer between metals in sliding contact examined by auger emission spectroscopy

Metallic transfer between polycrystalline metals in sliding contact was examined. Hemispherical riders of iron, nickel, and cobalt were slid on tungsten, tantalum, niobium, and molybdenum disks in ultrahigh vacuum. Auger emission spectroscopy was used to monitor the elemental composition of the disk surfaces. Iron, nickel, and cobalt transferred to tungsten, whereas only cobalt transferred to tantalum, niobium, and molybdenum. The results of this investigation are discussed in terms of the cohesive energy and strain hardening characteristics of the specimen materials.

Pepper, S. V.↗

Soft X‐Ray Absorption Spectroscopy With a Flat Liquid Jet in Vacuum Using a Table‐Top Laser‐Induced Plasma Source

ABSTRACT In this work, we demonstrate the integration of a flat liquid jet sample delivery system into a compact soft x‐ray absorption spectrometer using a table‐top laser‐induced plasma source. A high‐speed flat liquid sheet is formed by the collision of two cylindrical jets. This micrometer‐thin lamella can ideally be utilized for transmission‐mode soft x‐ray absorption spectroscopy using krypton plasma emission. Detailed analysis of the jet's thickness profile is achieved applying Lambert–Beer's law. Measurements on water, focusing on the oxygen K‐edge, reveal a lamella thickness profile ranging from 500 nm to 1 μm over a length of 3.8 mm. Additionally, we have investigated aqueous solutions of iron salts, capturing near edge x‐ray absorption fine structure spectra over a broad spectral range from the nitrogen K‐edge to the iron L‐edge. Focused analysis on iron species in aqueous solutions enabled us to distinguish quantitatively between the oxidation states of Fe 2+ and Fe 3+ at the iron L‐edge. Our results are compared with measurements obtained under similar conditions at a synchrotron.

Holburg, Jonathan [Department Optics/Short Wavelen↗

Metrological and Spectral Characterization of the Aspera Flight Optics

Aspera is a NASA's Astrophysics Pioneers mission, led by the University of Arizona. The aim of this mission is to study the presence of hot gasses (T=10^5-10^6 K) in the circumgalactic medium (CGM) and how the flow of these gasses affects galactic formation. One key enabling technology in the Aspera optical system is the use of more efficient UV-reflective optical coatings particularly at around 103.2 nm where the O VI emission line is located . In order to meet radiometric effective area requirements, the Goddard Space Flight Center (GSFC) code 551 Optics Branch applied Al (aluminum) + eLiF (enhanced lithium fluoride) on these optics, where the Al+LiF is annealed at elevated temperature (~250˚C) after the deposition and thus providing an improved version of the Al+LiF used in FUSE . Furthermore, these optics are encapsulated with a thin film of atomic layer deposited MgF2 at the Jet Propulsion Laboratory for enhanced durability . The efficiency and durability of these coatings depends on the quality of the optical surface in terms of cleanliness and roughness. Roughness increases the scatter off the coating and reduces the specular reflectance, and surface contaminants can accommodate moisture and other contaminants, increase scattering, and are weak points in the coating that may affect adhesion and subsequently the longevity of these coatings. Extensive optical metrology is necessary to minimize and quantify the impact of surface roughness and contaminants on optical surfaces. In this proceeding we report the inspection procedure implemented for Aspera optics at GSFC, from initial receiving of the optics to post-coating. Inspection includes Atomic Force Microscopy (AFM), Scanning White Light Interferometry (SWILI), Dark Field Microscopy (DFM), Phase Shifting Interferometry (PSI), and Vacuum ultraviolet (VUV) spectroscopy. Combinations of these techniques are used to inspect flight optics at each of the following steps: i) as-received, pre-cleaning inspection, ii) pre-coating, post-cleaning inspection, and iii) post-coating inspection. The evolution of roughness and other surface inspections such as contaminants are compared between each step to quantify the effect each step has on the flight optics. The final far ultraviolet (FUV) spectral performance of witness samples coated with the flight optics are presented.

Far Ultraviolet (FUV)↗

Analytical study of spacecraft deposition contamination by internal reflection spectroscopy

The in-situ vacuum chamber designed around the IRE was tested under vacuum. The contamination analyzer system was tested using two liquid contaminant materials. The analysis of the contaminants on the SL-4 rendezvous window shows that the material has methyl silicone, hydroxyl, and carbonyl radicals. The analysis of the outgassing material from Shuttle TPS shows silicone as the primary product.

Mookherji, T. K.↗