Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utah geothermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utah FORGE 1-2409: PetroQuip Energy Services Zonal Isolation Solution for Geothermal Wells - 2024 Annual Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells by PetroQuip Energy Services, presented by Robert Coon. This video slide presentation discusses the proposed design and development of a multi-stage system consisting of an Open-Hole Packer (OHP), a Locking Bridge Plug (LBP), and a corresponding Locating Profile (LP). This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

2022 GETEM Geothermal Drilling Cost Curve Update: Preprint

The Geothermal Electricity Technology Evaluation Model (GETEM) is an essential tool for the Department of Energy's (DOE) Geothermal Technology Office (GTO) to understand the performance and cost of technologies it is seeking to improve. This detailed model is used for supply curve analyses, assessing the current economic feasibility and Levelized Cost of Energy (LCOE) of hydrothermal geothermal systems and EGS, and evaluating the potential impact of advanced geothermal technologies. GETEM can be used to estimate the performance and costs of currently available U.S. geothermal power systems. It is also used to estimate the costs of technologies 5 to 20 years in the future, given the direction of potential research, development, and demonstration (RD&D) projects. The model is intended to help GTO determine which proposed RD&D programs and projects might offer the most efficient improvement when using taxpayer funding. The model requires annual updates as well as revisions to reflect the current state of the art. Drilling costs are a significant portion of total geothermal development costs. The current GETEM drilling cost inputs rely on drilling data from 2009 and require an updated analysis of more recent data to ensure they remain representative of current technologies. An updated, more accurate understanding of costs could help the geothermal industry secure project development financing and investment funding and better allow the oil and gas (O&G) industry (both operators and service companies) weigh potential geothermal market participation and customization. This report details recent drilling improvements from the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) and O&G, comparing drilling performance and costs with values in GETEM, particularly the baseline drilling cost curves. Though drilling performance at FORGE has improved significantly, we did not find associated cost decreases that would justify lowering the GETEM baseline cost curves as of now.

API↗

2022 GETEM Geothermal Drilling Cost Curve Update

The Geothermal Electricity Technology Evaluation Model (GETEM) is an essential tool for the U.S. Department of Energy's (DOE) Geothermal Technologies Office (GTO) to understand the performance and cost of technologies it is seeking to improve. This detailed model is used for supply curve analyses, assessing the current economic feasibility and levelized cost of energy (LCOE) of hydrothermal geothermal systems and enhanced geothermal systems (EGS), and evaluating the potential impact of advanced geothermal technologies. GETEM can be used to estimate the performance and costs of currently available U.S. geothermal power systems. It is also used to estimate the costs of technologies 5 to 20 years in the future, given the direction of potential research, development, and demonstration (RD&D) projects. The model is intended to help GTO determine which proposed RD&D programs and projects might offer the most efficient improvement when using taxpayer funding. The model requires annual updates as well as revisions to reflect the current state of the art. Drilling costs are a significant portion of total geothermal development costs. The current GETEM drilling cost inputs rely on drilling data from 2009 and require an updated analysis of more recent data to ensure they remain representative of current technologies. An updated, more accurate understanding of costs could help the geothermal industry secure project development financing and investment funding and better allow the oil and gas (O&G) industry (both operators and service companies) to weigh potential geothermal market participation and customization. This report details recent drilling improvements from the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) and the O&G sector, comparing drilling performance and costs with values in GETEM, particularly the baseline drilling cost curves. Although drilling performance at FORGE has improved significantly, we did not find associated cost decreases that would justify lowering the GETEM baseline cost curves at this time.

API↗

Evaluation of Physics-Based Limiter Redesign Drilling and Alternative Bit Design at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The project will leverage advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Physics-Based Limiter Redesign and Bit Performance Analysis at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC (GPC), an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration, with increased footage on bottom for each bit coupled with increased bit life and time drilling. The project leverages advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate rock reduction technologies. The first demonstration well has been completed, with 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However, in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges. This paper provides updates on drilling activities conducted since the Phase 1 demonstration well at GDC-36 which was drilled from November 2023-January 2024. Additional analysis of the bit performance has been conducted. Furthermore, in subsequent wells drilled by GPC, PDC bits have been used extensively, building on the gains realized at GDC-36. GPC has continued to work with bit vendors to identify designs that last longer in the harsh, air-drilled 8.5” portions of the wells. Planning for the Phase 2 demonstration at Prati-44 is ongoing.

15 GEOTHERMAL ENERGY↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai'i

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy's Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company's GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

building cooling↗

2025 Geothermal Drilling Cost Curves Update: Preprint

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy’s Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company’s GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

15 GEOTHERMAL ENERGY↗

Formation of a Large Cold Groundwater Mantle Helium Anomaly and High Temperature Geothermal Resources in Response to Bimodal Magmatism Near Roosevelt Hot Springs and Utah FORGE, Milford Valley, Southwest Utah

Abstract A large mantle helium anomaly and separate domains of high heat flow are the predominant manifestations of bimodal magmatic activity in the Milford valley. The mantle helium anomaly (1.9–2.6 R/Ra) covers 270 km 2 and is subdivided into two separated domains: a cold shallow groundwater regime and high temperature hydrothermal activity. The zone of anomalous heat flow covers >100 km 2 and is also subdivided into two adjacent domains, comprising hydrothermal activity at Roosevelt Hot Springs (RHS) (3–7 W/m 2 ) and conductive heat flow (100–180 mW/m 2 ). While the transfer of heat and mantle helium at RHS are coupled, heat and helium transfer are decoupled in the adjacent cold groundwater regime to the west. Both the mantle helium and geothermal anomalies are attributed to recent mafic‐felsic magmatic intrusions of >400 km 3 , however, the absence of volcanic eruptions <500,000 years indicates magmas stall before rising to shallow crustal level <10 km depth. Deep level magmatism produces a felsic composition melt, which is inferred to be responsible for the widespread and near uniform range of diluted mantle helium values. A thick and impermeable mass of crystalline granitic basement rock at the mid‐crustal level divides the ascent of mantle helium into separate flow paths. It may also impede the rise of buoyant magma trapping thermal energy that facilitates partial melting, slow cooling, and development of a thick thermal aureole. Partitioning of convective and conductive thermal regimes and independent flow paths supplying deeply derived helium characterize the development of a large long‐lived magma‐related geothermal system.

Geochemistry & Geophysics↗

Utah FORGE 3-2514: Strain Sensing Array for Deformation Characterization - 2024 Annual Workshop Presentation

This is a presentation on the Strain Sensing Array to characterize deformation at the FORGE site project by Clemson University, presented by Lawrence Murdoch. The project's objective was to evaluate the feasibility of measuring and interpreting tensor strain data to improve the performance of EGS. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 23, 2024.

15 GEOTHERMAL ENERGY↗

Utah FORGE Groundwater Levels: Updated March 2022

This Excel spreadsheet contains Utah FORGE groundwater data for wells WOW2 and WOW3. The data was updated on March 16th, 2022 and contains legacy data. Groundwater data includes the level, offset, date, and time for each measurement. Temperature, drift, water elevation and other parameters are recorded. Figures in the data include a water elevation over time plot. Legacy data ranges from year 1976 to 2019 and updated data ranges from year 2019 to 2021.

15 GEOTHERMAL ENERGY↗

Utah FORGE Telluric Monitoring Experiment Transfer Functions

The Utah Frontier Observatory for Research in Geothermal Energy (FORGE) attempted a stimulation at well 16A(78)-32 during April and May 2022. We recorded telluric and magnetotelluric (MT) data before, during, and after the well stimulation experiment using the FORGE Telluric Monitoring (FTM) array to constrain transients in the Earth's electrical structure caused by the stimulation.

15 GEOTHERMAL ENERGY↗

Utah FORGE 5-2557: Trixial Shear and Wellbore Breakout Tests Report and Data

Included are a report and data from triaxial shear tests on simulated Sierra White fault gouge and a borehole stimulation experiment. This serves as a progress report for the Role of Fluid and Temperature in Fracture Mechanics and Coupled Thermo-Hydro-Mechanical-Chemical (THMC) Processes for Enhanced Geothermal Systems project by Purdue University (Utah FORGE R&D project 5-2557). Tests were done with Sierra White granite (SWG) to investigate slip mechanisms and to evaluate the fracture initiation and propagation from a geothermal borehole. Raw data is provided alongside a report on all experimental testing protocols, experimental design, and results.

15 GEOTHERMAL ENERGY↗

Connecting In Situ Stress and Wellbore Deviation to Near-Well Fracture Complexity Using Phase-Field Simulations

The interactions among in situ stress, rock fabric, wellbore geometry, natural fractures, and other natural or man-made defects create highly complex fracture trajectories in the near-wellbore region, far more intricate than those in the far-field. These near-wellbore complexities are critical for the Utah FORGE project and Enhanced Geothermal Systems (EGS) in general. Frictional pressure loss in the near-wellbore region during stimulation can significantly influence the growth of far-field fractures, while pressure losses during circulation serve as a major source of energy dissipation. Near-wellbore fracture complexities are often observable through image logs, offering valuable insights into in situ stress characteristics. However, leveraging this information requires a high-fidelity model capable of capturing the interplay among the diverse factors influencing fracture behavior.

58 GEOSCIENCES↗

Utah FORGE: Powder X-ray Diffraction Data from Well 16A(78)-32 Core

This dataset from Lawrence Livermore National Laboratory (LLNL) consists of four raw X-ray diffraction (XRD) scans and preliminary results of quantitative XRD analysis. The scanned samples were prepared from four subcores, which came from various depths of the FORGE well 16A(78)-32 core. Desired core lengths were selected from available core photos (on GDR), provided by FORGE personnel, and subcored at LLNL. The XRD scans were collected in May 2023 at LLNL as pre-experimental characterization data for these subcores, which will be used in core-flooding experiments at LLNL and in triaxial direct shear experiments at Los Alamos National Laboratory as part of DOE Project 5-2428. XRD scans are in RAW file format (e.g., FORGE-5477-full.raw) and are suitable for viewing and analysis using open-source quantitative XRD software (e.g., Profex; www.profex-xrd.org ) and/or other proprietary instrument software.

15 GEOTHERMAL ENERGY↗

Utah FORGE InSAR Data from 2022

Interferometric Synthetic Aperture Radar data from the TerraSAR-X and the TanDEM-X satellite missions operated by the German Space Agency (DLR). Interferometric pairs (interferograms) were created using generic mapping tool GMT-SAR processing software (see link in Resources). Data from January through June 2022.

15 GEOTHERMAL ENERGY↗

Sequential Fracture Activation and Stress Evolution During EGS Stimulation at Utah FORGE Revealed by Waveform Cross‐Correlation

Mapping fracture networks in Enhanced Geothermal Systems (EGS) is essential for optimizing reservoir performance, yet complex fracture evolution during stimulation remains difficult to resolve. This study examines the evolution of microseismicity and fracture networks during stage 3 of the 2022 EGS stimulation at the Utah Frontier Observatory for Research in Geothermal Energy site. We map the fracture network represented by 20 clusters of seismic events identified by waveform similarities with cross-correlation. We characterize their geometric properties such as strike, dip, length, and width, and analyze the time evolution of activated fractures. The results reveal a systematic fracture evolution: early activation of pre-existing natural fractures, complex network development during peak injection, and continued activation of less favorably oriented fractures post-injection. Magnitude calibration using the Principal Component Analysis of cross-correlated waveforms improves relative amplitude measurements, refining estimations of the Gutenberg-Richter b-values with spatial variations in b-values suggesting stress re-distribution across the stimulated area. Analysis of the stress state of selected fractures further shows that fractures requiring higher excess pore pressure primarily activate at the end of injection and post-injection, highlighting stress transfer due to pore pressure as a dominant triggering mechanism. These findings provide insights into fracture propagation, stress evolution, and seismic hazard assessment in EGS reservoirs.

Asirifi, Richard [Texas A & M Univ., College Stati↗

Utah FORGE 5-2557: Role of Fluid and Temperature in Fracture Mechanics and Couples THMC Processes for Enhanced Geothermal Systems - 2024 Annual Workshop Presentation

This is a presentation on the Role of Fluid and Temperature in Fracture Mechanics and Couples THMC Processes for Enhanced Geothermal Systems by Purdue University, presented by Laura Pyrak-Nolte. This video slide presentation describes the development and validation of a macroscopic model that can account for local deformation/friction behavior, seismic/aseismic behavior, chemical reactions, and determine the adequacy of classic Coulomb failure vs. rate-and-state friction. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 13, 2024.

15 GEOTHERMAL ENERGY↗

Utah FORGE 1-2410: Development of a Smart Completion and Stimulation Solution - 2024 Annual Workshop Presentation

This is a presentation on the Development of a Smart Completion & Stimulation Solution by Welltec, presented by Ricardo Vasques. This video slide presentation discusses the development of an (1) annular isolation system, (2) a stimulation isolation system, and (3) a multi open-close flow system for geothermal environments. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 15, 2024.

15 GEOTHERMAL ENERGY↗