Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utah Geothermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utah FORGE 1-2409: Zonal Isolation Solution for Geothermal Wells - Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells project by PetroQuip Energy Services, presented by VP of operations Robert Coon. The project's objective was to design and develop a multi-stage system for zonally isolating fluids inside and outside of geothermal well casings. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Play Fairway Analysis: Structurally Controlled Geothermal Systems in the Eastern Great Basin Extensional Regime, Utah

A research team with membership from the University of Utah/Energy & Geoscience Institute, the University of Utah/Dept. of Geology & Geophysics, and the Utah Geological Survey, undertook a play fairway analysis (PFA) for geothermal resources in the Eastern Great Basin (EGB) extensional tectonic regime of western Utah. This is a high-priority region for geothermal exploration because active Basin and Range (B&R) extension with volcanism having a N-S strike is superimposed upon pre-existing E-W belts of plutonic rocks and large-scale structural lineaments. Cumulative heat flow along the N-S strike of the state totals approximately 5 GWt above background stable interior. Three electricity producing power plants currently exist with substantial potential for increase. Succinctly, our PFA approach aims to resolve potential sources of heat and permeability in the region, which are the two principal criteria for establishing a geothermal resource. An initial Phase 1 was carried out using only existing geoscientific data in the area. Criteria selected for focusing heat potential include direct heat flow measurements in boreholes, magnetotelluric (MT) low resistivity anomalies, fluid/gas geochemistry, and proximity to recent volcanic eruptions. Permeability is established through geological structures (fault density, critically stressed areas, seismicity, gravity), and MT low resistivity anomalies. In Phase II of this PFA project, additional geological, geophysical and geochemical data were acquired and analysis carried out primarily over promising composite common risk (CCR) areas initially identified in Phase I in order to focus prospectivity and prepare for drilling recommendations. These prospects are near the Twin Peaks rhyolite field, high heat flow areas north of the producing Cove Fort system, and geophysical structure beneath the Crater Knoll area off the northeast flank of the Mineral Mountains. Additional data included MT site fill-in, structural mapping and analysis using high-resolution imagery, gravity and on-ground mapping, Nodal 3C passive seismic collection, and passive 3He surveying. Heat source and permeability potential are again expressed in terms of their individual common risk segment (CRS) maps, with a color scheme using green for most favorable (low risk) and red for least favorable (high risk). Diverse data types are united through the technique of probability kriging, which establishes prospectivity thresholds for each data type and then computes probability of exceeding that threshold over the PFA area. Modified CRS and CCRS maps are compared to those of Phase I to highlight tighter prospectivity focus. In doing so, the prospectivity threshold for heat was increased significantly to narrow the targeting. In the final Phase III of this project where a recommended deep thermal gradient hole was sited, additional geophysical, geochemical and geological field collection and analysis was carried out to refine drill hole targeting. This includes prospect-scale MT, gravity, structure, passive seismic deployment (Cove Fort area), and detailed 3He isotope profiling. It was the recommendation of the DOE Technical Monitoring Team (TMT) that one or more holes be sited in the north-ern Cove Fort area where legacy TG gradient holes showed high cumulative heat flow. These were to be of moderate depth, 2000-3000 feet, to reach the geothermal fluid table expected to start in excess of 1000 feet depth. The drilling organization stipulated by the DOE/GTO was that of the USGS Research Drilling Program (RDP) centered in Las Vegas, NV. A detailed well plan, appended to this report, was developed principally by Dr. Ben Barker consulting to University of Utah, Dr. Steve Pye on the DOE TMT, Mr. Steven Crawford of the USGS-RDP, and the project PI Phil Wannamaker. However, temperature and possible H 2 S at the systems lead to cancellation of the drilling last-minute as this appeared outside the experience base of the USGS-RDP. We hope to have the opportunity to revisit the test drilling and expand the Play Fairway Analysis of this region at some point in the future.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Well 16A(78)-32 Core Analysis Results

This dataset features petrographic, X-Ray Diffraction (XRD), and Scanning Electron Microscopy Analyses of core samples from well 16A(78)-32, which serves as the injection well for the Utah FORGE Enhanced Geothermal System (EGS) project. In addition to an overview of the analysis, the following items have been included here: images of 21 entire thin sections in plane-polarized and cross-polarized light from 16 depths, scanning electron microscope back scatter electron photomosaic maps of 21 thin sections from 16 depths, bulk XRD data from 16 depths, clay-sized XRD patterns from 16 depths, an optical petrography report, and scanning electron microscopy and energy dispersive spectroscopy analyses of eight selected samples.

15 GEOTHERMAL ENERGY↗

A Frequency-Domain-Based Algorithm for Detecting Microseismicity Using Dense Surface Seismic Arrays

We propose a new frequency-domain-based algorithm for detecting small-magnitude seismic events using dense surface seismic arrays. Our proposed method takes advantage of the high energy carried by S waves, and approximate known source locations, which are used to rotate the horizontal components to obtain the maximum amplitude. By surrounding the known source area with surface geophones, we achieve a favorable geometry for locating the detected seismic events with the backprojection method. To test our new detection method, we used a dense circular array, consisting of 151 5 Hz three-component geophones, over a 5 km aperture that was in operation at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) in southcentral Utah. We apply the new detection method during a small-scale test injection phase at FORGE, and during an aftershock sequence of an Mw 4.1 earthquake located ~30 km north of the geophone array, within the Black Rock volcanic field. We are able to detect and locate microseismic events (Mw<0) during injections, despite the high level of anthropogenic activity, and several aftershocks that are missing from the regional catalog. By comparing our method with known algorithms that operate both in the time and frequency domain, we show that our proposed method performs better in the case of the FORGE injection monitoring, and equally well for the off-array aftershock sequence. Our new method has the potential to improve microseismic event detections even in extremely noisy environments, and the proposed location scheme serves as a direct discriminant between true and false detections.

Geochemistry & Geophysics↗

Utah FORGE: Well 16B(78)-32 Drill Core Fracture Analysis Images and Data

This dataset contains drilling core data from well 16B(78)-32, including PDF documents with flattened core images annotated by feature type and core interval, as well as spreadsheets detailing feature morphologies by depth, planar feature measurements, and planar feature orientations rotated to in situ conditions. Core was recovered from three intervals, one per stimulation stage, in the crystalline rocks affected by the stimulation of well 16A(78)-32. Seven core runs were conducted, yielding 135.8 feet of recovered core. Features in the core were categorized into planar fractures, semi-planar fractures, unbroken mineralized fractures, rough fractures, curviplanar fractures, concave-convex surfaces, and planar compositional features such as mylonite or dike-like structures. Planar features were measured while the core was positioned horizontally, with the core axis aligned to a downhole azimuth of 42 degrees. Planar core measurements from stimulations 2 and 3 that could be confidently correlated with FMI data were rotated to in situ orientations. This was done by rotating the planes along vertical and horizontal axes to match the azimuth and inclination data recorded in the directional survey of well 16B(78)-32, as well as applying an axial rotation to resemble the fracture orientations observed in the FMI log at corresponding depths. Coherent sets of planar fracture measurements were made by aligning the core within each 3-foot section of the dissected core barrel, and between adjacent 3-foot sections within a core run by matching rock fabrics, saw cuts and/or tool marks. Where coherent fracture measurements could not be made within a core run, data sets are denoted by a subscript (i.e. 2-Ta and 2-Tb both come from tangent core run number 2).

15 GEOTHERMAL ENERGY↗

Utah FORGE Well 16A(78)-32 Simplified Discrete Fracture Network Data

The FORGE team is making these fracture models available to researchers wanting a set of natural fractures in the FORGE reservoir for use in their own modeling work. They have been used to predict stimulation distances during hydraulic stimulation at the open toe section of well 16A(78)-32. This is a simplified DFN (discrete fracture network) dataset, that was generated using FracMan, for Utah FORGE well 16A(78)-32. A short, well-illustrated, report describing the data is also included in the provided archive file.

15 GEOTHERMAL ENERGY↗

Utah FORGE Raw Microgravity Composite Data: Updated 10/2021.

This is a microgravity dataset from the Utah FORGE site near Milford, Utah. This composite dataset was updated in October, 2021 and contains data from December 17th, 2018 through September 24th, 2021. The data includes the GPS location of the measurement, date of the measurement, name of the station, relative difference in gravity, and coordinates of the station. This data was generated by the Utah Geological Survey.

15 GEOTHERMAL ENERGY↗

Terrestrial Aqueously Altered Magmatic Dike Forming Sulfate-Rich Hydrothermal Fluids to Constrain Martian Habitability

Intrusion of magma into a water-bearing crust can create a habitable hydrothermal environment, as seen on Earth. As the rock surrounding the intrusion is subjected to heat it can 1) release water, and different chemical species, from pre-existing minerals, and 2) interact with volatiles released from the cooling magma, which can create a geothermal brine with a distinct composition suitable for a range of chemotrophs. Hence, studying such environments on Earth is important in the search for life beyond our planet. The geothermal brine’s nature is dependent on the host rock and the magmatic properties. On Mars basaltic and sulfur-rich soils are dominant and therefore investigating basaltic magmatic interaction with sulfate-rich sediments and their associated habitats is key for recognizing potential habitats on Mars. The NASA Perseverance Rover at Jezero Crater has detected aqueously altered igneous rocks, potentially intrusive in origin, with secondary carbonates, sodium perchlorate and sulfates. Such an environment may have been habitable. Therefore, we investigate the intrusion of a magmatic dike into Jurassic sulfate-rich sediments from the San Rafael Swell, Utah, to reconstruct the geothermal fluids and assess their putative habitability.

B Baharier↗

Utah FORGE 1-2409: PetroQuip Energy Services Zonal Isolation Solution for Geothermal Wells - 2024 Annual Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells by PetroQuip Energy Services, presented by Robert Coon. This video slide presentation discusses the proposed design and development of a multi-stage system consisting of an Open-Hole Packer (OHP), a Locking Bridge Plug (LBP), and a corresponding Locating Profile (LP). This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

2022 GETEM Geothermal Drilling Cost Curve Update: Preprint

The Geothermal Electricity Technology Evaluation Model (GETEM) is an essential tool for the Department of Energy's (DOE) Geothermal Technology Office (GTO) to understand the performance and cost of technologies it is seeking to improve. This detailed model is used for supply curve analyses, assessing the current economic feasibility and Levelized Cost of Energy (LCOE) of hydrothermal geothermal systems and EGS, and evaluating the potential impact of advanced geothermal technologies. GETEM can be used to estimate the performance and costs of currently available U.S. geothermal power systems. It is also used to estimate the costs of technologies 5 to 20 years in the future, given the direction of potential research, development, and demonstration (RD&D) projects. The model is intended to help GTO determine which proposed RD&D programs and projects might offer the most efficient improvement when using taxpayer funding. The model requires annual updates as well as revisions to reflect the current state of the art. Drilling costs are a significant portion of total geothermal development costs. The current GETEM drilling cost inputs rely on drilling data from 2009 and require an updated analysis of more recent data to ensure they remain representative of current technologies. An updated, more accurate understanding of costs could help the geothermal industry secure project development financing and investment funding and better allow the oil and gas (O&G) industry (both operators and service companies) weigh potential geothermal market participation and customization. This report details recent drilling improvements from the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) and O&G, comparing drilling performance and costs with values in GETEM, particularly the baseline drilling cost curves. Though drilling performance at FORGE has improved significantly, we did not find associated cost decreases that would justify lowering the GETEM baseline cost curves as of now.

API↗

2022 GETEM Geothermal Drilling Cost Curve Update

The Geothermal Electricity Technology Evaluation Model (GETEM) is an essential tool for the U.S. Department of Energy's (DOE) Geothermal Technologies Office (GTO) to understand the performance and cost of technologies it is seeking to improve. This detailed model is used for supply curve analyses, assessing the current economic feasibility and levelized cost of energy (LCOE) of hydrothermal geothermal systems and enhanced geothermal systems (EGS), and evaluating the potential impact of advanced geothermal technologies. GETEM can be used to estimate the performance and costs of currently available U.S. geothermal power systems. It is also used to estimate the costs of technologies 5 to 20 years in the future, given the direction of potential research, development, and demonstration (RD&D) projects. The model is intended to help GTO determine which proposed RD&D programs and projects might offer the most efficient improvement when using taxpayer funding. The model requires annual updates as well as revisions to reflect the current state of the art. Drilling costs are a significant portion of total geothermal development costs. The current GETEM drilling cost inputs rely on drilling data from 2009 and require an updated analysis of more recent data to ensure they remain representative of current technologies. An updated, more accurate understanding of costs could help the geothermal industry secure project development financing and investment funding and better allow the oil and gas (O&G) industry (both operators and service companies) to weigh potential geothermal market participation and customization. This report details recent drilling improvements from the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) and the O&G sector, comparing drilling performance and costs with values in GETEM, particularly the baseline drilling cost curves. Although drilling performance at FORGE has improved significantly, we did not find associated cost decreases that would justify lowering the GETEM baseline cost curves at this time.

API↗

Utah FORGE: Seismic Velocity Models, February 2021

This dataset contains a map, showing the Utah FORGE seismic stations, and seismic velocity model data. There are 61 1-D velocity models which are in a compressed TAR file. A paper is referenced at the end of this description which discusses the use of these data in 3D modelling. The paper summary follows: We expand the application of spatial autocorrelation (SPAC) from typical 1-D Vs profiles to quasi-3-D imaging via Bayesian Monte Carlo inversion (BMCI) using a dense nodal array (49 nodes) located at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site. Combinations of 4 and 9 geophones in subarrays provide for 36 and 25 1-D Vs profiles, respectively. Profiles with error bars are determined by calculating coherency functions that fit observations in a frequency range of 0.2-5 Hz. Thus, a high-resolution quasi-3-D Vs model from the surface to 2.0 km depth is derived and shows that surface-parallel sedimentary strata deepen to the west, consistent with a 3-D seismic reflection survey. Moreover, the resulting Vs profile is consistent with a Vs profile derived from distributed acoustic sensing (DAS) data located in a borehole at the FORGE site. The quasi-3-D velocity model shows that the base of the basin dips ~22 degrees to the west and topography on the basement interface coincident with the Mag Lee Wash suggests that the bedrock interface is an unconformity. Reference: Zhang, H. and K. L. Pankow (2021). High-resolution Bayesian spatial auto-correlation (SPAC) pseudo-3D Vs model of Utah FORGE site with a dense geophone array, Geophys. Res. Int, https://doi.org/10.1093/gji/ggab049

15 GEOTHERMAL ENERGY↗

Evaluation of Physics-Based Limiter Redesign Drilling and Alternative Bit Design at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The project will leverage advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Physics-Based Limiter Redesign and Bit Performance Analysis at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC (GPC), an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration, with increased footage on bottom for each bit coupled with increased bit life and time drilling. The project leverages advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate rock reduction technologies. The first demonstration well has been completed, with 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However, in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges. This paper provides updates on drilling activities conducted since the Phase 1 demonstration well at GDC-36 which was drilled from November 2023-January 2024. Additional analysis of the bit performance has been conducted. Furthermore, in subsequent wells drilled by GPC, PDC bits have been used extensively, building on the gains realized at GDC-36. GPC has continued to work with bit vendors to identify designs that last longer in the harsh, air-drilled 8.5” portions of the wells. Planning for the Phase 2 demonstration at Prati-44 is ongoing.

15 GEOTHERMAL ENERGY↗

Utah FORGE Well 16A(78)-32 Core Photos

Images of core samples collected from Utah FORGE well 16A(78)-32. These images were created by stitching together multiple photographs resulting in a circumferential view of the cores exterior in two dimensions. Core footages (measured depths) are indicated in the file names, and are annotated on each image. The images, of which there are 30 in the .zip file, are in a .jpg format.

15 GEOTHERMAL ENERGY↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai'i

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy's Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company's GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

building cooling↗