Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Unbalanced load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Microgrid Networking for Maximal Load Delivery in Phase Unbalanced Distribution Grids: A Declarative Modeling Approach

Over the last several years, microgrids have increasingly become a part of the discussion about technologies that can improve the resilience of modern electrical grids. During extreme situations, microgrids have the capability to provide electrical service to customers within their boundaries when they would otherwise experience disruptions, and, when networked together, provide services to additional customers outside the microgrid boundaries. As a result, these technologies have motivated the community to develop new approaches for leveraging networked microgrid capabilities that utilize increasing levels of modeling sophistication. This has yielded a new challenge, where it has becoming increasingly difficult to fully quantify and evaluate the contribution of such detail. Here, the primary innovation presented in this paper is a method to standardize the approach to quantifying and evaluating these contributions via a declarative modeling approach that supports seamless mix-and-match of representations to ease comparison of modeling approaches and develop comprehensive understandings of how new contributions improve solutions to this problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unbalanced Parallel I/O: An Often-Neglected Side Effect of Lossy Scientific Data Compression

Lossy compression techniques have demonstrated promising results in significantly reducing the scientific data size while guaranteeing the compression error bounds. However, one important yet often neglected side effect of lossy scientific data compression is its impact on the performance of parallel I/O. Our key observation is that the compressed data size is often highly skewed across processes in lossy scientific compression. To understand this behavior, we conduct extensive experiments where we apply three lossy compressors MGARD, ZFP, and SZ, which are specifically designed and optimized for scientific data, to three real-world scientific applications Gray-Scott simulation, WarpX, and XGC. Our analysis result demonstrates that the size of the compressed data is always skewed even if the original data is evenly decomposed among processes. Such skewness widely exists in different scientific applications using different compressors as long as the information density of the data varies across processes. We then systematically study how this side effect of lossy scientific data compression impacts the performance of parallel I/O. We observe that the skewness in the sizes of the compressed data often leads to I/O imbalance, which can significantly reduce the efficiency of I/O bandwidth utilization if not properly handled. In addition, writing data concurrently to a single shared file through MPI-IO library is more sensitive to the unbalanced I/O loads. Therefore, we believe our research community should pay more attention to the unbalanced parallel I/O caused by lossy scientific data compression.

Wang, Xinying↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.

Matthews, Ronald C.↗

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Iteration-based Linearized Distribution-level Locational Marginal Price for Three-phase Unbalanced Distribution Systems

Distributed energy resources (DERs) are rocking the utilities’ business landscape. It calls for competitive market environments that incentivize DERs to form maximum operating efficiency. Among proposed pricing schemes, distribution-level locational marginal price (DLMP) is effective in signaling the marginal generation cost differences driven by energy losses and network constraints. It can be derived from a distribution-level optimal power flow (OPF) framework, as it essentially presents the sensitivity of optimized generation cost towards incremental loads. However, due to the high resistance-to-inductance ratio and unbalanced characteristics of distribution networks, computational affordable DLMPs are highly challenged. This article provides a linear-approximated DLMP that can be solved efficiently and generalized to account for reactive power flow, three-phase unbalanced loads and meshed network structure. The successive linear programming technique is introduced to enhance the model accuracy. Case studies on an IEEE 123-Bus system validate its accuracy against a nonlinear benchmark and capability in offering proper incentives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Distribution System Adaptive Restoration with Diverse Distributed Energy Resources

Distributed energy resources (DERs) can be utilized as alternative power sources for fast service recovery in cases of distribution system outages. However, the diverse characteristics and stochastic nature of DERs impose challenges on the optimal operation of di-verse resources during the restoration phase. Here, we introduce a hierarchical structure to coordinate distribution system entities and propose an adaptive restoration strategy to sustain a reliable power supply to outage loads in an unbalanced distribution system utilizing DERs. An efficient system reconfiguration model is developed to guarantee the radiality of restoration islands. The flexibility of DERs is evaluated by a novel method that focuses on the cumulative energy consumption, the superiority of which is also proven. Model predictive control (MPC) is adopted to enable the adjustment of system topology and DER operation strategies based on up-to-date data. The performance of the proposed restoration model is validated on a modified IEEE 123-bus test system. Moreover, the effectiveness of the proposed novel flexibility assessment and the MPC-based adaptive restoration strategy are verified through comparative studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗