Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “URANIUM 238”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comprehensive Baseline Environmental Monitoring of an Interim Legacy Waste Store in Arid Zone Australia - 20062

Radionuclide containing soil and rubble from the clean-up of a former uranium, thorium and rare earth minerals processing research facility carried out in the early 50's and 60's is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to developing a final disposal pathway commensurate with waste acceptance criteria, a comprehensive baseline environmental monitoring has been carried out to establish the background radiation levels. The survey included in situ gamma scanning of the surface soil ({sup 238}U, {sup 232}Th, {sup 40}K), a laboratory analysis of 86 soil samples (from 0-20 cm depth), which involved XRF measurements (U, Th, and rare earth metals) and spectroscopic analysis ({sup 238}U, {sup 232}Th, {sup 226}Ra and daughter nuclides). A time series of radon concentration measurements in air was established, while soil radon ({sup 222}Rn) and thoron ({sup 220}Rn) flux measurements were undertaken at 18 different locations. The 2018 comprehensive baseline survey demonstrated radiation levels in the immediate vicinity of the Woomera interim waste store are typical background values of soil and rock. No contamination was detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical processes for recovery and purification of high-purity uranium-234 from aged plutonium-238

This work describes a streamlined approach to the recovery and purification of 234 U from aged 238 Pu. Key modifications to conventional techniques are described that result in an efficient uranium and plutonium separation process that successfully produced tens of grams of ultrahigh purity 234 U at Oak Ridge National Laboratory. A new processing scheme was developed using an anion exchange column run in a cycling mode with HNO 3 media as the primary uranium purification process. This was followed with a uranyl peroxide precipitation step to purify and solidify the uranium before conversion to U 3 O 8 . Both the traditional uranyl peroxide precipitation method and a new cascade uranyl peroxide precipitation process were used for final purification of the 234 U.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SCALE modeling of foil irradiations at WSU’s TRIGA with sensitivity/uncertainty analysis

We report the Washington State University TRIGA reactor was modeled in the SCALE system’s KENO neutron transport code. The model includes 119 fuel rods, a central boral control rod, 4 control blades, 5 irradiation ports, and 20 graphite reflector blocks within a rectangular aluminum grid box. The model accurately simulated the irradiation of depleted uranium and highly enriched uranium foils and predicted reaction rate ratios for 238 U(n,2n) 237 U / 238 U(n,γ) 239 U and 99 Mo / fission, which compared favorably to empirical values previously measured at Los Alamos. Finally, a sensitivity/uncertainty analysis was performed using the continuous-energy TSUNAMI-3D module of SCALE.

237Np↗

Lunar and Planetary Science XXXVI, Part 7

Topics discussed include: Lunar Geologic Mapping: Preliminary Mapping of Copernicus Quad High-Resolution Topography of Layers in the Valles Marineris Via Thermoclinometry ; The Critical Importance of Data Reduction Calibrations in the Interpretability of S-type Asteroid Spectra; (sup 238)U-(sup 206)Pb Age and Uranium-Lead Isotope Systematics of Mare Basalt 10017; Morphological Investigations of Martian Spherules, Comparisons to Collected Terrestrial Counterparts; The Vapor Pressure of Palladium at Temperatures up to 1973K; Areas of Favorable Illumination at the Lunar Poles Calculated from Topography; An Indigenous Origin for the South Pole-Aitken Basin Thorium Anomaly; Ar-Ar Ages of Nakhlites Y000593, NWA998, and Nakhla and CRE Ages of NWA998; Experiments on the Acoustic Properties of Titan-like Atmospheres; Analysis of Downstream Transitions in Morphology and Structure of Lava Channels on Mars; Structure and Bonding of Carbon in Clays from CI Carbonaceous Chondrites; Comparison of Three Hydrogen Distributions at the Equator of Mars; An Impact Origin for the Foliation of Ordinary Chondrites; A New Micrometeorite Collection from Antarctica and Its Preliminary Characterization by Microobservation, Microanalysis and Magnetic Methods; Volcanic Plumes and Plume Deposits on Io; Results of the Alpha-Particle-X-Ray Spectrometer on Board of the Mars Exploration Rovers; Effects of Oceans on Atmospheric Loss During the Stage of Giant Impacts; and Identification of Predominant Ferric Signatures in Association to the Martian Sulfate Deposits

Source record↗

Abundances of Uranium and Thorium Elements in Earth Estimated by Geoneutrino Spectroscopy

Abstract The decay of the primordial isotopes 238 U, 235 U, 232 Th, and 40 K has contributed to the terrestrial heat budget throughout the Earth's history. Hence, the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth models. The geoneutrinos produced by the radioactive decays of uranium and thorium have been observed with the Kamioka Liquid‐Scintillator Antineutrino Detector (KamLAND). Those measurements have been improved with more than 18‐year observation time, and improvement in detector background levels mainly with an 8‐year nearly reactor‐free period, which now permit spectroscopy with geoneutrinos. Our results yield the first constraint on both uranium and thorium heat contributions. The KamLAND result is consistent with geochemical estimations based on elemental abundances of chondritic meteorites and mantle peridotites. The High‐Q model is disfavored at 99.76% C.L. and a fully radiogenic model is excluded at 5.2 σ assuming a homogeneous heat producing element distribution in the mantle.

58 GEOSCIENCES↗

Producing 236 U reference standards for Accelerator Mass Spectrometry at the University of Notre Dame

36 U is a rare isotope of uranium, naturally occurring in ores with an abundance of 236 U/ 238 U$<$ 1 x 10 -9 . The ability to detect it and make isotopic ratio measurements has applications ranging from nuclear forensics and nonproliferation to energy production and environmental protection. Currently, Accelerator Mass Spectrometry (AMS) is the only technique sensitive enough to accurately measure 236 U/ 238 U isotopic ratios as they exist in naturally occurring ores in the range of 236 U/ 238 U = 10 -12 $-$ 10 -9 . Some AMS facilities have demonstrated their capabilities to make these measurements. Historically, the lack of commercially available reference standards covering the range of naturally occurring 236 U/ 238 U abundances has necessitated the use of absolute measurements, notoriously difficult to do using AMS, resulting in increased uncertainties in measurements and a reliance on knowledge of systematic effects. To mitigate these issues, various AMS facilities have sought to develop their own reference standards. Using a reference standard prepared for other forms of mass spectrometry, a series of AMS suitable standards was created through dilution with low-background natural uranium. The techniques used to produce and characterize these materials as well as analysis of them using AMS will be discussed.

236U↗

A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L

Abstract A NanoSIMS 50L is used to investigate uranium molecular ( 235 U 16 O, 236 U 16 O, 238 U 16 O, 235 U 1 H, 238 U 1 H, 236 U 16 O 1 H, and 238 U 16 O 1 H) and elemental ( 235 U, 236 U, and 238 U) secondary ion production during sputtering of synthetic UO 2 and the NIST-610 standard to determine if: (1) the 236 U 16 O/ 238 U 16 O molecular oxide ratio performs better than the 236 U/ 238 U elemental ratio, and (2) there is co-variance between the molecular hydrides and oxides. Despite an order of magnitude greater abundance of 236 U 16 O secondary ions (compared to 236 U), the 236 U 16 O/ 238 U 16 O ratios are less accurate than the 236 U/ 238 U ratios. Further work is needed before the higher count rate of the 236 U 16 O secondary ion can be used to obtain a better 236 U/ 238 U ratio. The second objective was undertaken because correction for the interference of 235 U 1 H on the 236 U secondary ion species typically utilizes the 238 U 1 H/ 238 U ratio. This becomes problematic in samples containing 239 Pu, so our aim was to understand if the hydride formation rate can be constrained independently of having to measure the 238 U 1 H. We document correlations between the hydride ( 238 U 1 H and 238 U 16 O 1 H) and oxide ( 236 U 16 O) secondary ions, suggesting that pursuing an alternative correction regime is worthwhile.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

07 ISOTOPE AND RADIATION SOURCES↗

Tracking natural CO 2 migration through a sandstone aquifer using Sr, U and C isotopes: Chimayó, New Mexico, USA

The geochemical and isotopic characteristics of groundwaters in Chimayó, New Mexico, reflect processes that affect water quality in the Tesuque Aquifer, which overlies a leaking natural CO 2 source in a structurally complex region. In this study, select isotopes (δ 13 C, 87 Sr/ 86 Sr, 234 U/ 238 U) are applied to groundwaters to better understand CO 2 transport mechanisms and related water-rock interactions that impact Chimayó groundwater. Carbon stable isotope ratios of dissolved inorganic carbon (DIC; δ 13 CDIC = -15.10‰ to 4.50‰) identify a distinct source of upward-migrating CO 2 that interacts with the groundwater. Additionally, groundwater 87 Sr/ 86 Sr compositions (0.7098 to 0.7154) reflect intrusion of varying amounts of saline water associated with the high CO 2 source, while 234 U/ 238 U ratios corroborate presence of deep groundwater and suggest impacts from distinctive natural uranium sources are affecting groundwater. Previous work proposed two CO 2 transport mechanisms at the site: (1) dissolved in deep brine that underlies the aquifer and (2) in the gas phase; this study uses isotope mixing models to identify wells that are affected by these CO 2 transport mechanisms and demonstrates that both transport mechanisms are associated with impaired groundwaters. Overall, this study demonstrates that applying multiple isotope systems (δ 13 CDIC, 87 Sr/ 86 Sr, 234 U/ 238 U) is a dynamic tool for identifying and measuring the impact of CO 2 leakage from a sequestration site.

58 GEOSCIENCES↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of low energy characteristic X-rays emitted present in U-10Mo HALEU alloy fuel

Advance high density monolithic alloy HALEU fuels have been scanned with a silicon drift detector scanning system to measure low-energy characteristic X-rays emitted by uranium daughters, as well as zirconium present as a foil diffusion barrier. Four peaks were measured across the surfaces of three plates, and are consistent with other thorium and protactinium peaks present in depleted uranium samples that are induced by the decay of 235 U and 238 U. Of the four peaks detected, three are dominated by the decay of 235 U, and one peak at 15.70 keV covers two characteristic X-rays from the zirconium diffusion barrier (Kα 1 ) and from a 231 Th 15.62 keV X-ray induced by 235 U α-decay. The low energies of these lines suggest that they are mostly emitted from the fuel meat surface, and the poor counting statistics caused by strong self-attenuation make these data a poor candidate for 235 U/ 238 U ratio analysis. We suggest, then, that these X-rays could be used for passive measurement of variations in the cladding thickness of these fuels to complement manual thickness measurement methods.

HALEU↗

Evaluation of the Effect of Burnup Acceleration on UO 2 Microstructure Evolution

Accelerated fuel qualification (AFQ) is a methodology by which new nuclear fuels are developed in an accelerated time frame compared with historical fuel qualification approaches. AFQ generally relies on high-fidelity physics-based modeling and simulation tools to adequately describe fuel performance as well as on revolutionary methods to accelerate burnup accumulation and collect relevant data more quickly. This report summarizes the use of advanced fuel modeling and simulation tools to evaluate microstructures from commercially irradiated fuel and microstructures from proposed MiniFuel irradiations, in which burnup accumulation is accelerated while prototypic temperature conditions are maintained. In this milestone, we used the mesoscale fuel performance code MARMOT to model the evolution of irradiated UO 2 microstructures and their potential restructuring at high burnup. The simulation conditions were informed by BISON models of both commercially irradiated fuel and MiniFuel. A first set of simulations investigated the recrystallization behavior of fully dense microstructures and showed full recrystallization at burnups as low as 52 MWd/kgU at 950°C. However, these simulations did not account for the presence of fission gas bubbles (predicted by BISON). Therefore, a second set of simulations including fission gas bubbles was performed and indicated that at the lowest temperature considered (650°C), the porous UO 2 microstructures have the highest total Gibbs free energies and are likely to recrystallize earlier than higher temperature cases (800 and 950°C), which agrees with high-burnup fuel characterization data. The results also showed that at lower temperature (650°C), the total free energies of the PWR fuel and MiniFuel microstructures are not significantly different. However, at the highest temperature (950°C), MiniFuel microstructures have a lower free energy than that of the PWR fuel microstructure. The competing effects between the temperature-dependent grain nucleation rate and the reduction of the free energy of the microstructure at higher temperature as a result of diffusion indicated that restructuring may occur at even higher temperatures than those considered in this study. In addition to the microstructure evolution modeling efforts, the burnup gradient across a single fuel specimen was also considered. This evaluation was for the VXF-15 position of the High Flux Isotope Reactor (HFIR) using the code suite HFIRCON, which was developed to automate the workflow for evaluating targets and fuel as they are irradiated in HFIR. The burnup gradient evaluation showed a dependence on both the axial and radial locations within the specimen, with a maximum difference of 1.7 between the inner and outermost radial layers. This relationship was further supported by considering the fission product speciation with respect to location within the specimen, which showed a higher concentration of 239 Pu, 240 Pu, and 241 Pu on the outer radial locations of the specimen than the center. The findings of the burnup and speciation evaluation show that some amount of self-shielding is occurring in the specimen when irradiated in the high-flux environment of HFIR; however, this impact is more pronounced for natural uranium when compared to 6% enrichment due to the higher ratio of 238 U in the specimen. Further analyses are required to understand the sensitivity of this gradient to spatial mesh and enrichment of the specimen.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Airborne Release Fractions from Surrogate Nuclear Waste Fires Containing Lanthanide Nitrates and Depleted Uranium Nitrate in 30% Tributyl Phosphate in Kerosene

Airborne contaminants from fires containing nuclear waste represent significant health hazards and shape the design and operation of nuclear facilities. Much of the data used to formulate DOE-HDBK-3010-94, “Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear Facilities,” from the U.S. Department of Energy, were taken over 40 years ago. The objectives of this study were to reproduce experiments from Pacific Northwest Laboratories conducted in June 1973 employing current aerosol measurement methods and instrumentation, develop an enhanced understanding of particulate formation and transport from fires containing nuclear waste, and provide modeling and experimental capabilities for updating current standards and practices in nuclear facilities. A special chamber was designed to conduct small fires containing 25 mL of flammable waste containing lutetium nitrate, ytterbium nitrate, or depleted uranium nitrate. Carbon soot aerosols showed aggregates of primary particles ranging from 20 to 60 nm in diameter. In scanning electron microscopy, ~200-nm spheroidal particles were also observed dispersed among the fractal aggregates. The 200-nm spherical particles were composed of metal phosphates. Airborne release fractions (ARFs) were characterized by leaching filter deposits and quantifying metal concentrations with mass spectrometry. The average mass-based ARF for 238 U experiments was 1.0 × 10 -3 with a standard deviation of 7.5 × 10 -4 . For the original experiments, DOE-HDBK-3010-94 states, “Uranium ARFs range from 2 × 10 -4 to 3 × 10 -3 , an uncertainty of approximately an order of magnitude.” Therefore, current measurements were consistent with DOE-HDBK-3010-94 values. ARF values for lutetium and ytterbium were approximately one to two orders of magnitude lower than 238 U. Furthermore, metal nitrate solubility may have varied with elemental composition and temperature, thereby affecting ARF values for uranium surrogates (Yb and Lu). In addition to ARF data, solution boiling temperatures and evaporation rates can also be deduced from experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗