Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UNDERGROUND STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.

In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around underground tunnels, and the potential impact on rock properties such as P-wave and S-wave velocities. The data presented from this report are associated with sites used for the development of underground repositories for the disposal of radioactive waste; these sites have been excavated in volcanic tuff (Yucca Mountain) and granite (HRL in Sweden, URL in Canada). Using the data from Yucca Mountain, a numerical simulation effort was undertaken to evaluate the effects of the damage zone on seismic responses. Calculations were performed using the parallelized version of the time-domain finitedifference seismic wave propagation code developed in the Geophysics Department at Sandia National Laboratories. From these numerical simulations, the damage zone does not have a significant effect upon the tunnel response, either for a purely elastic case or an anelastic case. However, what was discovered is that the largest responses are not true reflections, but rather reradiated Stoneley waves generated as the air/earth interface of the tunnel. Because of this, data processed in the usual way may not correctly image the tunnel. This report represents a preliminary step in the development of a methodology to convert numerical predictions of rock properties to an estimation of the extent of rock damage around an underground facility and its corresponding seismic velocity, and the corresponding application to design a testing methodology for tunnel detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Underground storage systems for high-pressure air and gases

This paper is a discussion of the safety and cost of underground high-pressure air and gas storage systems based on recent experience with a high-pressure air system installed at Moffett Field, California. The system described used threaded and coupled oil well casings installed vertically to a depth of 1200 ft. Maximum pressure was 3000 psi and capacity was 500,000 lb of air. A failure mode analysis is presented, and it is shown that underground storage offers advantages in avoiding catastrophic consequences from pressure vessel failure. Certain problems such as corrosion, fatigue, and electrolysis are discussed in terms of the economic life of such vessels. A cost analysis shows that where favorable drilling conditions exist, the cost of underground high-pressure storage is approximately one-quarter that of equivalent aboveground storage.

Beam, B. H.↗

Cyclic loading–unloading impacts on geomechanical stability of multiple salt caverns for underground hydrogen storage

Underground caverns in a salt dome are promising geologic features to store hydrogen because of salt’s extremely low permeability and self-healing behavior. The salt cavern storage community, however, has not fully understood the geomechanical behaviors of salt rock driven by quick operation cycles of injection–production, which may significantly impact the cost-effective storage-recovery performance of multiple caverns. Our field-scale generic model captures the impact of cyclic loading–unloading on the salt creep behavior and deformation under different cycle frequencies, operating pressure, and spatial order of operating cavern(s). This systematic simulation study indicates that the initial operation cycle and arrangement of multiple caverns play a significant role in the creep-driven loss of cavern volumes and cavern deformation. Finally, our future study will develop a new salt constitutive model based on geomechanical tests of site-specific salt rock to probe the cyclic behaviors of salt precisely both beneath and above the dilatancy boundary, including reverse (inverse transient) creep, the Bauschinger effect, and damage-healing mechanism.

08 HYDROGEN↗

Cyclic loading-unloading impacts on salt cavern stability: Implication for underground hydrogen storage

Underground caverns in salt formations are promising geologic features to store hydrogen (H2) because of salt’s extremely low permeability and self-healing behavior. Successful salt-cavern H2 storage schemes must maximize the efficiency of cyclic injection-production while minimizing H2 loss through adjacent damaged salt. The salt cavern storage community, however, has not fully understood the geomechanical behaviors of salt rocks driven by quick operation cycles of H2 injection-production, whic

Chang, Kyung Won↗

Operational Plan for Underground Storage Tank 322 R2U2

This Operational Plan provides the operator of the tank system with guidelines relating to the safe and compliant operation and maintenance of the tank system. The tank system schematic and list of emergency contacts shall be posted near the tank so they are visible to tank personnel. This Operational Plan shall be kept on file by the Facility Supervisor. It should be understood when managing this tank system that it is used to store hazardous waste temporarily for 90 calendar days or less. The rinsewater handled in the tank system is considered hazardous and may exhibit the characteristic of toxicity.

54 ENVIRONMENTAL SCIENCES↗

Sampling and Analysis Plan for LSL2 Underground Storage Tank Evaluation of PFAS in Soil: Protection of Groundwater

This SAP gathers all pertinent information relevant to the sampling and analysis of soil at the removal site for a former 10,000-gallon UST and reference sites in the vicinity of the excavation site. Data Quality Objectives establishes the process and steps for the acquisition of data. Data Flow Diagram establishes the decisions and next steps. Quality Assurance Project Plan establishes the quality requirements for data collection, including planning, implementation, and assessment of sampling, field measurements, and laboratory analysis. The work is being completed for DOE-SC Pacific Northwest Site Office.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing Hydrogen Storage Potential in U.S. Underground Gas Storage Facilities

Abstract Underground hydrogen storage is a long‐duration energy storage option for a low‐carbon economy. Although research into the technical feasibility of underground hydrogen storage is ongoing, existing underground gas storage (UGS) facilities are appealing candidates for the technology because of their ability to store and deliver natural gas. We estimate that UGS facilities in the United States (U.S.) can store 327 TWh (9.8 MMT) of pure hydrogen. A complete transition to hydrogen storage would reduce the collective working‐gas energy of UGS facilities by ∼75%; however, most (73.2%) UGS facilities could maintain current energy demand using a 20% hydrogen‐natural gas blend. U.S. UGS facilities can buffer 23.9%–44.6% of the high and low hydrogen demand projected for 2050, respectively, which exceeds the current percentage of natural gas demand buffered by storage. Thus, transitioning UGS infrastructure to hydrogen could substantially reduce the number of new hydrogen storage facilities needed to support a hydrogen economy.

08 HYDROGEN↗

Underground Pumped Hydroelectric Energy Storage

Underground pumped hydroelectric energy storage (UPHES) is an adaptation of conventional surface-pumped hydroelectric that uses an underground cavern or water structure as a lower reservoir. Conceptually, this seems a logical and sound solution to energy storage. The practical design and actual construction of large UPHES systems represent challenging tasks. Smaller UPHES systems may be more easily built, especially if existing underground and surface structures can be used. To date, no UPHES system, commercial or otherwise, has ever been installed and used. This chapter will overview concepts and design considerations for UPHES systems, both large and small.

25 ENERGY STORAGE↗