Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Recovering the efficiency of AlGaInP red micro-LEDs using sidewall treatments

A sidewall treatment process is proposed to recover the external quantum efficiency (EQE) loss in AlGaInP micro-LEDs ( μ LEDs). The proposed sidewall treatment consists of thermal annealing, ammonium sulfide chemical treatment, and sidewall passivation using atomic-layer deposition (ALD). The devices with sidewall treatment show improved optical power of more than 500% and 190% at 5 and 100 A cm −2 , respectively, compared to devices with ALD sidewall passivation. The reduction in EQE was 20% when shrinking the device dimensions from 100 × 100 to 20 × 20 μ m 2 . Finally, this work reveals that AlGaInP μ LEDs can be energy efficient by employing proper sidewall treatments.

Wong, Matthew S.↗

Implementation of Treatment Systems for Low and Intermediate Radioactive Waste at Site Radwaste Treatment Facility (SRTF), PR China - 12556

The AP1000 reactors being built in the People's Republic of China require a waste treatment facility to process the low and intermediate radioactive waste produced by these nuclear power stations. Westinghouse Electric Germany GmbH was successful in being awarded a contract as to the planning, delivery and commissioning of such a waste treatment facility. The Site Radwaste Treatment Facility (SRTF) is a waste treatment facility that can meet the AP1000 requirements and it will become operational in the near future. The SRTF is situated at the location of Sanmen, People's Republic of China, next to one of the AP1000 and is an adherent building to the AP1000 comprising different waste treatment processes for radioactive spent filter cartridges, ion-exchange resins and radioactive liquid and solid waste. The final product of the SRTF-treatment is a 200 l drum with cemented waste or grouted waste packages for storage in a local storage facility. The systems used in the SRTF are developed for these special requirements, based on experience from similar systems in the German nuclear industry. The main waste treatment systems in the SRTF are: - Filter Cartridge Processing System (FCS); - HVAC-Filter and Solid Waste Treatment Systems (HVS); - Chemical Liquid Treatment Systems (CTS); - Spent Resin Processing Systems (RES); - Mobile Treatment System (MBS). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots

Background: Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. Methods: For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house–developed finite-difference–based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. Results: In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average −0.01°C (range, −0.19°C to 0.34°C). The measured tumor temperature change was on average only −0.02°C (range, −0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. Conclusions: Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-254: Evaluating the Role of Mid-Treatment and Post-Treatment FDG-PET/CT in Predicting Progression-Free Survival and Distant Metastasis of Anal Cancer Patients Treated with Chemoradiotherapy

Purpose: To evaluate the role of mid-treatment and post-treatment FDG-PET/CT in predicting progression-free survival (PFS) and distant metastasis (DM) of anal cancer patients treated with chemoradiotherapy (CRT). Methods: 17 anal cancer patients treated with CRT were retrospectively studied. The median prescription dose was 56 Gy (range, 50–62.5 Gy). All patients underwent FDG-PET/CT scans before and after CRT. 16 of the 17 patients had an additional FDG-PET/CT image at 3–5 weeks into the treatment (denoted as mid-treatment FDG-PET/CT). 750 features were extracted from these three sets of scans, which included both traditional PET/CT measures (SUVmax, SUVpeak, tumor diameters, etc.) and spatialtemporal PET/CT features (comprehensively quantify a tumor’s FDG uptake intensity and distribution, spatial variation (texture), geometric property and their temporal changes relative to baseline). 26 clinical parameters (age, gender, TNM stage, histology, GTV dose, etc.) were also analyzed. Advanced analytics including methods to select an optimal set of predictors and a model selection engine, which identifies the most accurate machine learning algorithm for predictive analysis was developed. Results: Comparing baseline + mid-treatment PET/CT set to baseline + posttreatment PET/CT set, 14 predictors were selected from each feature group. Same three clinical parameters (tumor size, T stage and whether 5-FU was held during any cycle of chemotherapy) and two traditional measures (pre- CRT SUVmin and SUVmedian) were selected by both predictor groups. Different mix of spatial-temporal PET/CT features was selected. Using the 14 predictors and Naive Bayes, mid-treatment PET/CT set achieved 87.5% accuracy (2 PFS patients misclassified, all local recurrence and DM patients correctly classified). Post-treatment PET/CT set achieved 94.0% accuracy (all PFS and DM patients correctly predicted, 1 local recurrence patient misclassified) with logistic regression, neural network or support vector machine model. Conclusion: Applying radiomics approach to either midtreatment or post-treatment PET/CT could achieve high accuracy in predicting anal cancer treatment outcomes. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Accelerating Discovery of Solid‐State Thin‐Film Metal Dealloying for 3D Nanoarchitecture Materials Design through Laser Thermal Gradient Treatment

Thin‐film solid‐state metal dealloying (thin‐film SSMD) is a promising method for fabricating nanostructures with controlled morphology and efficiency, offering advantages over conventional bulk materials processing methods for integration into practical applications. Although machine learning (ML) has facilitated the design of dealloying systems, the selection of key thermal treatment parameters for nanostructure formation remains largely unknown and dependent on experimental trial and error. To overcome this challenge, a workflow enabling high‐throughput characterization of thermal treatment parameters is demonstrated using a laser‐based thermal treatment to create temperature gradients on single thin‐film samples of Nb‐Al/Sc and Nb‐Al/Cu. This continuous thermal space enables observation of dealloying transitions and the resulting nanostructures of interest. Through synchrotron X‐ray multimodal and high‐throughput characterization, critical transitions and nanostructures can be rapidly captured and subsequently verified using electron microscopy. The key temperatures driving chemical reactions and morphological evolutions are clearly identified. While the oxidation may influence nanostructure formation during thin‐film treatment, the dealloying process at the dealloying front involves interactions solely between the dealloying elements, highlighting the availability and viability of the selected systems. Further, this approach enables efficient exploration of the dealloying process and validation of ML predictions, thereby accelerating the discovery of thin‐film SSMD systems with targeted nanostructures.

36 MATERIALS SCIENCE↗

The effect of sanitary landfill leachate aging on the biological treatment and assessment of photoelectrooxidation as a pre-treatment process

Highlights: • Photoelectrooxidation (PEO) emerges as a new technology for leachate treatment. • Aging of sanitary landfills acts on leachate composition and biodegradability. • PEO is applied as leachate pretreatment before the biological processes. • PEO produced significant changes in the leachate matrix, easing biological process. - Abstract: The sanitary landfill leachate is a dark liquid, of highly variable composition, with recalcitrant features that hamper conventional biological treatment. The physical–chemical characteristics of the leachate along the landfill aging, as well as their effects on the efficiency of the conventional treatment, were evaluated at this paper. The feasibility of photoelectrooxidation process as an alternative technique for treatment of landfill leachates was also determined. Photoelectrooxidation experiments were conducted in a bench-scale reactor. Analysis of the raw leachate revealed many critical parameters demonstrating that the recalcitrance of leachate tends to increase with time, directly influencing the decline in efficiency of the conventional treatment currently employed. The effects of current density and lamp power were investigated. Using a 400 W power lamp and a current density of 31.5 mA cm{sup −2}, 53% and 61% efficiency for the removal of ammoniacal nitrogen and chemical oxygen demand were respectively achieved by applying photoelectrooxidation process. With the removal of these pollutants, downstream biological treatment should be improved. These results demonstrate that photoelectrooxidation is a feasible technique for the treatment of sanitary landfill leachate, even considering this effluent’s high resistance to treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beneficial effect of post-deposition treatment in high-efficiency Cu(In,Ga)Se{sub 2} solar cells through reduced potential fluctuations

World-record power conversion efficiencies for Cu(In,Ga)Se{sub 2} (CIGS) solar cells have been achieved via a post-deposition treatment with alkaline metals, which increases the open-circuit voltage and fill factor. We explore the role of the potassium fluoride (KF) post-deposition treatment in CIGS by employing energy- and time-resolved photoluminescence spectroscopy and electrical characterization combined with numerical modeling. The bulk carrier lifetime is found to increase with post-deposition treatment from 255 ns to 388 ns, which is the longest charge carrier lifetime reported for CIGS, and within ∼40% of the radiative limit. We find evidence that the post-deposition treatment causes a decrease in the electronic potential fluctuations. These potential fluctuations have previously been shown to reduce the open-circuit voltage and the device efficiency in CIGS. Additionally, numerical simulations based on the measured carrier lifetimes and mobilities show a diffusion length of ∼10 μm, which is ∼4 times larger than the film thickness. Thus, carrier collection in the bulk is not a limiting factor for device efficiency. By considering differences in doping, bandgap, and potential fluctuations, we present a possible explanation for the voltage difference between KF-treated and untreated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-106: An Institutional Review of Using Commercially Available Software to Evaluate Treatment Plan Quality for Various Treatment Sites and Beam Deliveries

Purpose: Use Sun Nuclear Quality Reports™ with PlanIQ™ to evaluate different treatment delivery techniques for various treatment sites. Methods: Fifteen random patients with different treatment sites were evaluated. These include the Head/Neck, prostate, pelvis, lung, esophagus, axilla, bladder and abdomen. Initially, these sites were planned on the Pinnacle {sup 3} V9.6 treatment planning system and utilized nine 6MV step-n-shoot IMRT fields. The RT plan, dose and structure sets were sent to Quality Reports™ where a DVH was recreated and the plans were compared to a unique Plan Algorithm for each treatment site. Each algorithm has its own plan quality metrics and objectives, which include the PTV coverage, PTV maximum dose, the prescription dose outside the target, doses to the critical structures, and the global maximum dose and its location. Each plan was scored base on meeting each objective. Plans may have been reoptimized and reevaluated with Quality Reports™ based on the initial score. PlanIQ™ was used to evaluate if any objective not met was achievable or difficult to obtain. A second plan using VMAT delivery was created for each patient and scored with Quality Reports™. Results: There were a wide range of scores for the different treatment sites with some scoring better for IMRT plans and some better for the VMAT deliveries. The variation in the scores could be attributed to the treatment site, location, and shape of the target. Most deliveries were chosen for the VMAT due to the short treatment times and quick patient throughput with acceptable plan scores. Conclusion: The tools are provided for both physician and dosimetrist to objectively evaluate the use of VMAT delivery versus the step-n-shoot IMRT delivery for various sites. PlanIQ validates if objectives can be met. For the physicist, a concise pass/fail report is created for plan evaluation.

60 APPLIED LIFE SCIENCES↗

SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

60 APPLIED LIFE SCIENCES↗

Advanced Mixed Waste Treatment Project Overcomes Challenges to Complete Treatment of Debris Waste - 20616

The Advanced Mixed Waste Treatment Project (AMWTP), operated by Fluor Idaho for the Department of Energy Idaho Operations Office, completed the last of its debris waste treatment in the fall of 2019. Concluding that work-scope was certainly not without its challenges. Fluor Idaho and its employees had to adapt to treating extremely challenging waste types, such as high-fissile gram materials and potentially pyrophoric and reactive wastes coming down the stretch. It also had to complete the sizing of large waste boxes from Mound Laboratories in inner-contamination enclosures designed to capture the extremely fine, 'flighty' plutonium-238 in its high-efficiency particulate air filters. Very few waste treatment facilities in the DOE Complex have completed their missions. In fact, most large-scale waste treatment facilities are still under construction with many months or years remaining before 'hot operations' begin. AMWTP is unique because it functioned as a 'one-stop shop.' Transuranic and low-level waste characterization, treatment, certification, and shipping all occurred there. AMWTP concluded the most challenging part of its mission and will continue to ship material out of the state of Idaho for the next decade. This paper will provide a background of the AMWTP mission, and the adaptations to its operating permit, equipment, or treatment processes to address challenging waste types. AMWTP will leave behind a legacy of being one of the most successful waste treatment facilities in the history of the DOE Complex. The facility was well-conceived, well-constructed, and well-executed; it was done right from start to finish. During the course of its waste treatment mission, the facility was required to adapt to changing conditions by treating extremely challenging waste types. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prolongation of Total Treatment Time Because of Infrequently Missed Days of Treatment Is Not Associated With Inferior Biochemical Outcome After Dose-Escalated Radiation Therapy for Prostate Cancer

Purpose: Prolongation of treatment time with radiation therapy (RT) is associated with inferior disease control for many rapidly proliferating tumors, but it is uncertain whether the same effect is seen in prostate cancer. Methods and Materials: 596 patients underwent with curative-intent RT for adenocarcinoma of the prostate. By National Comprehensive Cancer Network criteria, men were classified as having low-risk (30%), medium-risk (40%), or high-risk (30%) disease. The median RT dose was 72 Gy. Androgen-deprivation therapy (ADT) was used in 45%. The idealized treatment time was defined as the total elapsed time (including weekends) to complete treatment if started on a Monday. Missed days of treatment, defined as the number of days beyond the idealized treatment time, was recorded for all patients. Missed days were added to the end of therapy resulting in a longer treatment time. Analysis was conducted for missed days and other standard prognostic variables against freedom from biochemical failure (FFBF). Results: The median number of missed days was 2 (range, -3 to 22). With a median follow-up of 51 months, men with 5 or more missed days had similar 4-year FFBF rates (79% vs. 83% in men with <5 missed days, p = 0.0809), especially in the subset of men receiving 74 Gy or greater (89% for both groups, p = 0.8008). Analysis of missed days was performed for the subsets of dose, ADT, and risk category. Men without ADT had a lower FFBF rate with more missed days (p = 0.0030), but this association was not seen in men treated to a dose of 74 Gy or greater (p = 0.7425). On multivariate analysis, dose (p = 0.0010), T stage (p = 0.0145), and prostate-specific antigen level (p < 0.0001) were associated with FFBF, but Gleason score (p = 0.1351) and missed days (p = 0.3767) were not. Conclusions: Slight prolongation of treatment time (e.g., {<=}7 days) was not associated with inferior FFBF, especially in men receiving an RT dose of 74 Gy or greater.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of an implantable MOSFET dosimeter designed for use with hypofractionated external beam treatments and its applications for breast and prostate treatments

Purpose: An implantable metal-oxide semiconductor field effect transistors-based dosimeter has recently been developed for the in vivo monitoring of hypofractionated radiotherapy. This DVS-HFT dosimeter is designed for fraction sizes of 340-950 cGy and can also be used for bis in die fraction monitoring. The current work reports on the testing and evaluation of this dosimeter, including both its basic characteristics as well as its performance during simulated clinical treatment plans. Methods: The authors tested the dose rate dependence of this dosimeter (300 MU/min versus 600 MU/min), the treatment time dependence (4 min per treatment versus up to 60 min per treatment), and the dose and energy dependence (6 and 18 MV irradiations of 700-900 cGy per fraction). Additionally, they irradiated the detectors in-phantom with breast and prostate hypofractionated treatments. Results: The detectors showed no significant dose rate, treatment time, energy, or dose dependence. Furthermore, the detectors were found to perform within manufacturer tolerances for all hypofractionated treatments examined, accurately reporting the measured dose (average disagreement of - 0.65%). Conclusions: These dosimeters appear well suited for in vivo monitoring of hypofractionated radiotherapy doses, and thereby, have the potential to improve patient care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques

Purpose: Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp), and intensity-modulated radiotherapy (IMRT). Methods: Under Institutional Review Board (IRB) exemption, radiotherapy treatment plans of 111 cases were retrospectively analyzed. The distance between skin surface and 95% isodose line was measured. For measurements, Gafchromic EBT2 films were used on a humanoid unsliced phantom. Multiple layers of variable thickness of superflab bolus were placed on the breast phantom and CT scanned for planning. Treatment plans were generated using four techniques with two different grid sizes (1 Multiplication-Sign 1 and 2.5 Multiplication-Sign 2.5 mm{sup 2}) to provide optimum dose distribution. Films were placed at different depths and exposed with the selected techniques. A calibration curve for dose versus pixel values was also generated on the same day as the phantom measurement was conducted. The DICOM RT image, dose, and plan data were imported to the in-house software. On axial plane of CT slices, curves were drawn at the position where EBT2 films were placed, and the dose profiles on the lines were acquired. The calculated and measured dose profiles were separated by check points which were marked on the films before irradiation. The segments of calculated profiles were stretched to match their resolutions to that of film dosimetry. Results: On review of treatment plans, the distance between skin and 95% prescribed dose was up to 8 mm for plans of 27 patients. The film measurement revealed that the medial region of phantom surface received a mere 45%-50% of prescribed dose. For wedges, FF, and eComp techniques, region around the nipple received approximately 80% of prescribed dose, although only IMRT showed inhomogeneous dose profile. At deeper depths mainly (6-11 mm depths), film dosimetry showed good agreement with the TPS calculation. In contrast, the measured dose at a 3-mm depth was higher than TPS calculation by 15%-30% for all techniques. For the tangential and IMRT techniques, 1 Multiplication-Sign 1 mm{sup 2} grid size showed a smaller difference than that with a 2.5 Multiplication-Sign 2.5 mm{sup 2} grid size compared to the measurements. Conclusions: In general, TPS even with advanced algorithms do not provide accurate dosimetry in the buildup region, as verified by EBT2 film for all treatment techniques. For all cases, TPS and measured doses were in agreement from 6 mm in depth but differed at shallower depths. Grid size plays an important role in dose calculation. For accurate dosimetry small grid size should be used where differences are lower between TPS and measurements.

60 APPLIED LIFE SCIENCES↗

SU-D-16A-04: Accuracy of Treatment Plan TCP and NTCP Values as Determined Via Treatment Course Delivery Simulations

Purpose: To to determine if tumor control probability (TCP) and normal tissue control probability (NTCP) values computed on the treatment planning image are representative of TCP/NTCP distributions resulting from probable positioning variations encountered during external-beam radiotherapy. Methods: We compare TCP/NTCP as typically computed on the planning PTV/OARs with distributions of those parameters computed for CTV/OARs via treatment delivery simulations which include the effect of patient organ deformations for a group of 19 prostate IMRT pseudocases. Planning objectives specified 78 Gy to PTV1=prostate CTV+5 mm margin, 66 Gy to PTV2=seminal vesicles+8 mm margin, and multiple bladder/rectum OAR objectives to achieve typical clinical OAR sparing. TCP were computed using the Poisson Model while NTCPs used the Lyman-Kutcher-Bruman model. For each patient, 1000 30-fraction virtual treatment courses were simulated with each fractional pseudo- time-oftreatment anatomy sampled from a principle component analysis patient deformation model. Dose for each virtual treatment-course was determined via deformable summation of dose from the individual fractions. CTVTCP/ OAR-NTCP values were computed for each treatment course, statistically analyzed, and compared with the planning PTV-TCP/OARNTCP values. Results: Mean TCP from the simulations differed by <1% from planned TCP for 18/19 patients; 1/19 differed by 1.7%. Mean bladder NTCP differed from the planned NTCP by >5% for 12/19 patients and >10% for 4/19 patients. Similarly, mean rectum NTCP differed by >5% for 12/19 patients, >10% for 4/19 patients. Both mean bladder and mean rectum NTCP differed by >5% for 10/19 patients and by >10% for 2/19 patients. For several patients, planned NTCP was less than the minimum or more than the maximum from the treatment course simulations. Conclusion: Treatment course simulations yield TCP values that are similar to planned values, while OAR NTCPs differ significantly, indicating the need for probabilistic methods or PRVs for OAR risk assessment. Presenting author receives support from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗