Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Traps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Linear ion trap for second-order Doppler shift reduction in frequency standard applications

The authors have designed and are presently testing a novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced. The authors have succeeded in trapping mercury ions and xenon ions in the presence of helium buffer gas. Trap times as long as 2000 s have been measured.

Prestage, John D.↗

Analytic potential in a linear radio-frequency quadrupole trap with cylindrical electrodes

An analytical expression is derived for a radio-frequency ion trap of novel configuration consisting of a four-sectored hollow cylinder enclosed between two end caps. The cylindrical geometry of the sectored trap provides shielding against the buildup of charge and also makes it possible to calculate the potential within the trap by solving Laplace's equation for given boundary conditions. Equations are presented for calculating the time-averaged potential generated by the RF fields, the end-cap potential, and the potential arising from the application of a dc bias on two of the four electrode sectors. It is shown that, near the ends of this trap, the effective potential arising from the RF fields acts to propel ions out of the trap and that the addition of a dc bias on two neighboring sectors generates an inhomogeneous field in the trap which produces a force on the ions along the trap's long axis in a direction dependent on the sign of the bias.

Melbourne, R. K.↗

Locating Electron Traps In A CCD

"Pocket pumping" is technique for mapping sizes of electron-trapping defects and picture elements within which traps located in charge-coupled device (CCD). Two kinds of traps: forward and reverse. Pocket pumping relies on fact that in terms of charges measurable by external circuitry, forward traps affect only forward, while reverse traps affect only reverse, transfer of charge along row or column of picture elements. Charges in picture elements shifted back and forth many times to amplify trapping effect by repetition. Traps smaller than 1 electron detected by this method.

Janesick, James↗

LET spectra of trapped anomalous cosmic rays in low-Earth orbit

Observations aboard Cosmos satelites discovered trapped anomalous cosmic rays (ACRs), tracked the variation in their intensity in 1986-1988, and measured their fluence, spectrum, and composition at solar minimum in the previous solar cycle. The MAST instrument aboard the SAMPEX satellite has observed trapped anomalous cosmic rays in the present solar cycle, confirmed the general features of the Cosmos data, and provided the first detailed observations of trapped ACRs. In this paper we apply theoretical modeling of trapped ACRs, which is shown to provide a reasonably good description of both the Cosmos and SAMPEX data, to calculate the integral linear-energy-transfer (LET) spectra due to trapped ACRs in typical low-Earth orbits. We compare these calculations with the LET spectra produced by galactic cosmic rays (GCRs) and non-trapped ACRs in order to assess the relative radiation hazard posed by trapped ACRs.

Tylka, A. J.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Recent Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas removal performance and operational lifetime of the gas trap have been affected by contamination in the ITCS coolant. However, the gas trap has performed flawlessly with regard to its purpose of preventing gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump. This paper discusses on-orbit events over the course of the last year related to the performance and functioning of the gas trap.

Leimkuehler, Thomas O.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Pressure Fluctuations due to ‘Trapped Waves’ in Heated Jets

An experimental study was conducted to investigate the presence and characteristics of ‘trapped waves’ in the near field of a small axisymmetric jet at heated conditions. Trapped waves occur within the potential core of compressible jets and manifest as distinct peaks in the unsteady pressure spectra measured just outside the jet near the nozzle exit. The existence and properties of the trapped wave spectral peaks in round and rectangular jets of various sizes in subsonic and supersonic conditions were studied in our recent experiments, at cold conditions [7]. The current work extends the study to heated jets. Pressure fluctuation spectra near the nozzle exit are analyzed for a small (D = 6.35 mm) axisymmetric jet at stagnation temperature ratios up to 1.6. It is shown that trapped waves continue to persist in heated jets. At sufficiently high Mach numbers, one of the trapped wave harmonics emerges as screech tone, a behavior consistent with that observed in cold jets. For a given Mach number, the frequencies of both trapped waves and screech increase with jet temperature with no significant change occurring in their amplitudes. The Strouhal numbers based on jet diameter for the trapped waves and screech continue to follow similar scaling laws as observed previously with cold jets.

aeroacoustics↗

New electron trap in p-type Czochralski silicon

A new electron trap (acceptor level) was discovered in p-type Czochralski (CZ) silicon by current transient spectroscopy. The behavior of this trap was found to be similar to that of the oxygen thermal donors; thus, 450 C annealing increases the trap concentration while high-temperature annealing (1100-1200 C) leads to the virtual elimination of the trap. The new trap is not observed in either float-zone or n-type CZ silicon. Its energy level depends on the group III doping element in the sample. These findings suggest that the trap is related to oxygen, and probably to the acceptor impurity as well.

Mao, B.-Y.↗

Two-fence concept for efficient trapping of vortices on airfoils

Previous work on the use of a vortex trapped above a wing in order to produce high lift at low angles of attack is extended here. It is first postulated that the optimum way to trap a vortex is to design the airfoil section and wing so that the flow along the vortex core is minimized. It is then shown that a vertical fence both in front of and behind the separation bubble generated by the trapped vortex is an effective way to reduce the mass flow removal and its associated drag to a negligible amount. In order to show that vertical surfaces upstream and downstream of the vortex separation bubble have an opposite effect on the source requirements for vortex trapping, conformal mapping methods are used to obtain the solutions for a variety of simple two-dimensional, inviscid, incompressible flow configurations. Trapped-vortex flowfield solutions for the flow over flat plate and Clark-Y airfoils are then used to demonstrate that the heights of the fences can be tailored to make the required mass withdrawal (and therefore, the drag due to trapping) to be vanishingly small.

Rossow, Vernon J.↗

Micromachined Dust Traps

Micromachined traps devised to capture dust particles for analysis without contaminating them. Based on micromachined structures retaining particles, rather than adhesives or greases interfering with scanning-electron-microscope analysis or x-ray imaging. Unlike maze traps and traps enmeshing particles in steel wool or similar materials, micromachined traps do not obscure trapped particles. Internal geometries of traps range from simple cones to U-shapes, all formed by etching silicon.

Bearman, Gregory H.↗

Modeling the Stability of Volatile Deposits in Lunar Cold Traps

There are several mechanisms acting at the cold traps that can alter the inventory of volatiles there. Primarily, the lunar surface is bombarded by meteoroids which impact, melt, process, and redistribute the regolith. Further, solar wind and magnetospheric ion fluxes are allowed limited access onto the regions in permanent shadow. Also, although cold traps are in the permanent shadow of the Sun, there is a small flux of radiation incident on the regions from interstellar sources. We investigate the effects of these space weathering processes on a deposit of volatiles in a lunar cold trap through simulations. We simulate the development of a column of material near the surface of the Moon resulting from space weathering. This simulation treats a column of material at a lunar cold trap and focuses on the hydrogen content of the column. We model space weathering processes on several time and spatial scales to simulate the constant rain of micrometeoroids as well as sporadic larger impactors occurring near the cold traps to determine the retention efficiency of the cold traps. We perform the Monte Carlo simulation over many columns of material to determine the expectation value for hydrogen content of the top few meters of soil for comparison with Lunar Prospector neutron data.

Crider, D. H.↗

Probabilistic Model for Low Altitude Trapped Proton Fluxes

A new approach is developed for the assessment of low altitude trapped proton fluxes for future space missions. Low altitude fluxes are dependent on solar activity levels due to the resulting heating and cooling of the upper atmosphere. However, solar activity levels cannot be accurately predicted far enough into the future to accommodate typical spacecraft mission planning. Thus, the approach suggested here is to evaluate the trapped proton flux as a function of confidence level for a given mission time period. This is possible because of a recent advance in trapped proton modeling that uses the solar 10.7 cm radio flux, a measure of solar cycle activity, to calculate trapped proton fluxes as a continuous function of time throughout the solar cycle. This trapped proton model is combined with a new statistical description of the 10.7 cm flux to obtain the probabilistic model for low altitude trapped proton fluxes. Results for proton energies ranging from 1.5 to 81.3 MeV are examined as a function of time throughout solar cycle 22 for various orbits. For altitudes below 1000 km, fluxes are significantly higher and energy spectra are significantly harder than those predicted by the AP8 model.

Xapsos, M. A.↗

Stacking Multiple Ion Captures in The High Performance Antiproton Trap (HiPAT)

The High performance Antiproton Trap (HiPAT) research project was initiated by the Marshall Space Flight Center's propulsion Research Center to examining the fundamental behavior of low energy antiprotons. Stored antiproton would ultimately be used for experimental demonstration of basic propulsive concepts. Matter-antimatter annihilation produces approximately 10(exp 8) MJ/g nearly 10 orders of magnitude more energy per unit mass than chemical based combustion, hence NASA's interest. To achieve containment, HiPAT utilizes a type of electromagnetic bottle know as a Penning trap positioned within an ultrahigh vacuum test section. Recently, the HiPAT hardware configuration has been enhanced to facilitate the capture of multiple normal matter ion burst. This endeavor is often referred to as "stacking" and used to increasing the number of captured particles. A prior normal matter experimental effort, successfully demonstrated the effectiveness of single burst capture. The stacking process is accomplished by manipulating the electric field generated by the confinement electrodes i.e. adjusting the well potential depth. These potential well values are initially configured to maximize the quantity of captured ions per burst; shallow wells with a depth of 100 volt or less (referenced to the incoming ion beam energy) are typically selected. Once captured, a cooling interval is required to reduce the energy of trapped particles below the lower extent of the "trap door" (or leading electrode) ion emitting potential. This is necessary such that a new burst of hot ions can be introduced while preventing those already inside from escaping. The cooling time is driven by a combination of mechanisms such as synchrotron radiation, background gas scattering, and resistive damping in a time scale on the order of minutes. A potential for reducing this hold period is to actively manipulate the electric field shape, using the power supply control system, to produce a deeper potential well. The trapped ions ride down the morphing well to a lower potential energy, leaving margin to once again cycle the "trap door" capturing a new burst while limiting the number of escaping ions. By adjusting the magnitude and timing of the potential well shaping, subsequent shots from the ion beam can be captured on a time scale shorter then that dictated by the standard inject, capture and cool technique. Currently, experimental tests are under way examining the functionally of this system for stacking multiple ions bursts within the HiPAT system.

Martin, James J.↗

Trapping of gas mixtures by amorphous water ice

Our studies on gas trapping in amorphous water ice at 24-100 K were extended, by using mixtures of CH4, CO, N2, and Ar, rather than single gases. In 1:1 gas:(water vapor) mixtures, the competition among these gases on the available sites in the ice showed that the trapping capacity for the various gases is determined not only by the structure and dynamics of the ice, but is also influenced by the gas itself. Whereas at 24-35 K all four gases are trapped in the ice indiscriminantly, at 50-75 K there is a clear enhancement, in the order of CH4 > CO > N2 > or approximately Ar. This order is influenced by the gas-water interaction energy, the size of the trapped gas atom or molecule, the type of clathrate-hydrate formed (I or II) and, possibly, other factors. It seems that the gas can be trapped in the amorphous ice in several different locations, each being affected in a different way by the deposition temperature and gas composition. Once a gas atom or molecule is trapped in a specific location, it is predestined to emerge in one of eight different temperature ranges, which are associated with changes in the ice. The experimentally observed enhancements, together with the findings on the gas composition of comet Halley, might enable an estimation of the gas composition in the region of comet formation.

NASA Discipline Number 52-10↗

Manipulating Neutral Atoms in Chip-Based Magnetic Traps

Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.

Aveline, David↗

Evidence for Surface and Subsurface Ice Inside Micro Cold-Traps on Mercury's North Pole

The small obliquity of Mercury causes topographic depressions located near its poles to cast persistent shadows. Many [1, 9, 15] have shown these permanently shadowed regions (PSRs) may trap water ice for geologic time periods inside cold-traps. More recently, direct evidence for the presence of water ice deposits inside craters was remotely sensed in RADAR [5] and visible imagery [3]. Albedo measurements (reflectence at 1064 nm) obtained by the MErcury Space ENviroment GEochemistry and Ranging Laser Altimeter (MLA) found unusually bright and dark areas next to Mercury's north pole [7]. Using a thermal illumination model, Paige et al. [8] found the bright deposits are correlated with surface cold-traps, and the dark deposits are correlated with subsurface cold-traps. They suggested these anomalous deposits were brought to the surface by comets and were processed by the magnetospheric radiation flux, removing hydrogen and mixing C-N-O-S atoms to form a variety of molecules which will darken with time. Here we use a thermal illumination model to find the link between the cold-trap area fraction of a rough surface and its albedo. Using this link and the measurements obtained by MESSENGER we derive a surface and a subsurface ice distribution map on Mercury's north pole below the MESSENGER spatial resolution, approximately 500 m. We find a large fraction of the polar ice on Mercury resides inside micro cold-traps (of scales 10 - 100 m) distributed along the inter-crater terrain.

Laser Altimeter↗

Progress Report on the Improved Linear Ion Trap Physics Package

This article describes the first operational results from the extended linear ion trap frequency standard now being developed at JPL. This new design separates the state selection/interrogation region from the more critical microwave resonance region where the multiplied local oscillator (LO) signal is compared to the stable atomic transition. Hg+ ions have been trapped, shuttled back and forth between the resonance and state selection traps. In addition, microwave transitions between the Hg+ clock levels have been driven in the resonance trap and detected in the state selection trap.

Linear Ion Trap↗