Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Light-induced microwave noise in superconducting microwave-optical transducers

Microwave-to-optical transducers are integral to the future of superconducting quantum computing, as they would enable scaling and long-distance communication of superconducting quantum processors through optical-fiber links. However, optically induced microwave noise poses a significant challenge in achieving quantum transduction between microwave and optical frequencies. In this work, we study light-induced microwave noise in an integrated electro-optical transducer harnessing the Pockels effect of thin-film lithium niobate. We reveal three sources of added noise with distinctive time constants ranging from sub-100 ns to milliseconds. Furthermore, our results provide insights into the mechanisms and corresponding mitigation strategies for light-induced microwave noise in superconducting microwave-optical transducers and pave the way toward realizing the ultimate goal of quantum transduction.

42 ENGINEERING↗

Generating Electricity with Hydraulically Amplified Self-Healing Electrostatic (HASEL) Transducers

This study identifies hydraulically amplified self-healing electrostatic (HASEL) transducers as electricity generators, contrary to their conventional role as actuators. HASELs are soft, variable-capacitance transducers inspired by biological muscles which were developed to mimic the flexibility and functionality of natural muscle tissues. This research characterizes HASELs as generators by reversing their energy conversion mechanism—generating electricity through mechanical deformation. The study assesses the practical laboratory performance of HASELs by analytic modeling and experimental evaluation. Outcomes of the study include the following: (i) up to 2.5 mJ per cycle per 50 mm wide HASEL pouch of positive net energy generation in experimental testing—corresponding to an energy density of 2.0 mJ cm−3; (ii) a maximum theoretical energy density of 4.2 mJ cm−3; (iii) the electromechanical characteristics governing efficient conversion; and (iv) design considerations to enhance HASEL generator performance in future applications. This study broadens HASEL’s applicability and utility as a multi-functional transducer for renewable energy and general adaptive electricity generation.

13 HYDRO ENERGY↗

Self-Sustainable IoT-Based Remote Sensing Powered by Energy Harvesting Using Stacked Piezoelectric Transducer and Thermoelectric Generator

We propose a self-powered remote multi-sensing system for traffic sensing which is powered by the collective energy harvested from the mechanical vibration of the road caused by the passing vehicles and from the temperature gradient between the asphalt of the road and the soil underneath. A stacked piezoelectric transducer converts mechanical vibrations into electrical energy and a thermoelectric generator harvests the thermal energy from the thermal gradient. Electrical energy signals from the stacked piezoelectric transducer and the thermoelectric generators are converted into usable DC power to recharge the battery using AC-DC and DC-DC converters working simultaneously. The multi-sensing system comprises an embedded system with a microcontroller that acquires data from the sensors and sends the sensory data to an IoT transceiver which transmits the data as RF packets to an ethernet gateway. The gateway converts the RF packets into Internet Protocol (IP) packets and sends them to a remote server. Laboratory and road-testing results showed over 98% sensory data accuracy with the system functioning solely powered by the energy harvested from the alternative energy sources. The successful maximum transmission distance obtained between the IoT, and the gateway was approximately 1 mile, which is a considerable transmission distance achieved in an urban environment. Successful operation of the self-powered multi-sensing system under both laboratory and road conditions contributes considerably to the fields of energy harvesting and self-powered remote sensing systems. The energy flow chart and efficiency for the steps in the system were found to be mechanical power from vehicles to the energy harvester of 0.25%, stacked PZT transducer efficiency was found to be 37%, and for the TEGs the efficiency is 11%. AC-to-DC and DC-to-DC converters’ efficiencies were found to be 90% and 11%. The wireless communication RF transceiver efficiency was found to be 62.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of electro-optical quantum transducers based on three-dimensional superconducting cavities

Quantum transducers enable the conversion of quantum information and signals between different physical platforms. Based on the pioneering works in three-dimensional superconducting cavity technology developed at Fermilab, we are advancing the development of three-dimensional microwave-optical transducers and exploring their applications in quantum information processing and sensing. We present our progress in the design, fabrication, and characterization of three-dimensional microwave cavities integrated with bulk lithium niobate resonators. The material characterization using three-dimensional cavities based on a resonant-type method allows for understanding of complex permittivity and loss mechanism of electro-optic materials at cryogenic temperatures. We also evaluate the potential of the high-efficiency quantum transducers in enhancing the performance of quantum sensors for applications such as dark matter detection, compared to conventional homodyne detection approaches. This manuscript has been authored by Fermi Research Alliance, LLC under Contract No. DE-AC0207CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics. This work is funded by the DOE's Early Career Research Program. This research used resources of the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Superconducting Quantum Materials and Systems Center (SQMS) under Contract No. DE-AC02-07CH11359.

Zorzetti, Silvia↗

Multiscale and multiphysics FEA simulation and materials optimization for laser ultrasound transducers

In this study, the relationship between the nanocomposite design and the laser ultrasound transducer (LUT) characteristics was investigated through simulations in multiple scale levels for material behavior, device response, and acoustic wave propagation in media. First, the effects of the nanoparticle size and concentration on the effective properties of composites were quantitatively investigated with the finite element analysis (FEA) method. Second, the effective properties of the nanocomposite were assigned to the layer, which is modeled as a homogeneous material, in the FEA for the LUT simulating the energy conversion from the incident laser to the acoustic wave. Finally, the ultrasound propagation in the water was calculated by a theoretical wave propagation model. The FEA-based prediction was compared with the experimental data in the literature and a theoretical analysis for LUT based on Thermal-Acoustic coupling. As a result, the ultrasound waves on the transducer surface and at a distance in the water could be predicted. Based on the hierarchically integrated prediction procedure, the optimal conditions of the photoacoustic nanocomposites were investigated through the parametric study with the particle size and concentration as variables. The results guide the material designs optimized for different device characteristics, such as high pressure and broad bandwidth.

36 MATERIALS SCIENCE↗

Fatigue-Crack Detection and Monitoring through the Scattered-Wave Two-Dimensional Cross-Correlation Imaging Method Using Piezoelectric Transducers

Piezoelectric transducers are convenient enablers for generating and receiving Lamb waves for damage detection. Fatigue cracks are one of the most common causes for the failure of metallic structures. Increasing emphasis on the integrity of critical structures creates an urgent need to monitor structures and to detect cracks at an early stage to prevent catastrophic failures. This paper presents a two-dimensional (2D) cross-correlation imaging technique that can not only detect a fatigue crack but can also precisely image the fatigue cracks in metallic structures. The imaging method was based on the cross-correlation algorithm that uses incident waves and the crack-scattered waves of all directions to generate the crack image. Fatigue testing for crack generation was then conducted in both an aluminum plate and a stainless-steel plate. Piezoelectric wafer transducer was used to actuate the interrogating Lamb wave. To obtain the scattered waves as well as the incident waves, a scanning laser Doppler vibrometer was adopted for acquiring time-space multidimensional wavefield, followed with frequency-wavenumber processing. The proof-of-concept study was conducted in an aluminum plate with a hairline fatigue crack. A frequency-wavenumber filtering method was used to obtain the incident wave and the scattered wave wavefields for the cross-correlation imaging. After this, the imaging method was applied to evaluate cracks on a stainless-steel plate generated during fatigue loading tests. The presented imaging method showed successful inspection and quantification results of the crack and its growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fe protein docking transduces conformational changes to MoFe nitrogenase active site in a nucleotide-dependent manner

The reduction of dinitrogen to ammonia catalyzed by nitrogenase involves a complex series of events, including ATP hydrolysis, electron transfer, and activation of metal clusters for N 2 reduction. Early evidence shows that an essential part of the mechanism involves transducing information between the nitrogenase component proteins through conformational dynamics. Here, millisecond time-resolved hydrogen-deuterium exchange mass spectrometry was used to unravel peptide-level protein motion on the time scale of catalysis of Mo-dependent nitrogenase from Azotobacter vinelandii. Normal mode analysis calculations complemented this data, providing insights into the specific signal transduction pathways that relay information across protein interfaces at distances spanning 100 Å. Together, these results show that conformational changes induced by protein docking are rapidly transduced to the active site, suggesting a specific mechanism for activating the metal cofactor in the enzyme active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design of an ultra-low mode volume piezo-optomechanical quantum transducer

Coherent transduction of quantum states from the microwave to the optical domain can play a key role in quantum networking and distributed quantum computing. We present the design of a piezo-optomechanical device formed in a hybrid lithium niobate on silicon platform, that is suitable for microwave-to-optical quantum transduction. Our design is based on acoustic hybridization of an ultra-low mode volume piezoacoustic cavity with an optomechanical crystal cavity. The strong piezoelectric nature of lithium niobate allows us to mediate transduction via an acoustic mode which only minimally interacts with the lithium niobate, and is predominantly silicon-like, with very low electrical and acoustic loss. We estimate that this transducer can realize an intrinsic conversion efficiency of up to 35% with <0.5 added noise quanta when resonantly coupled to a superconducting transmon qubit and operated in pulsed mode at 10 kHz repetition rate. The performance improvement gained in such hybrid lithium niobate-silicon transducers make them suitable for heralded entanglement of qubits between superconducting quantum processors connected by optical fiber links.

Chiappina, Piero↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Numerical Methods to Evaluate Hyperelastic Transducers: Hexagonal Distributed Embedded Energy Converters

Hexagonal distributed embedded energy converters, also known as hexDEECs, are centimeter-scale energy transducers that leverage variable capacitance to generate electricity when their hyperelastic structure is dynamically deformed. To better understand, characterize, and optimize hexDEEC designs, a series of numerical methods and techniques were developed to model the hyperelastic mechanics of hexDEECs, electrostatic properties, and electricity generation characteristics. The numerical methods developed for the hyperelastic structural analysis were corroborated by empirical results from another study, and the models and equations for capacitance, electrostatic forces, and electrical potential energy were derived from fundamental electrostatic equations. These methods and techniques were implemented within the STAR-CCM+ multiphysics software Version 2020.3 (15.06.008) environment. Results from this analysis revealed methodologies and techniques necessary to model the energy converters, which will enable future exploration and optimization of more specific designs and corresponding applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular Transducers of Physical Activity Consortium (MoTrPAC): Mapping the Dynamic Responses to Exercise

Exercise provides a robust physiological stimulus that evokes cross-talk between a wide range of tissues via hormonal, cellular and molecular signals that when repeated regularly over time (i.e., training) improves physiological capacity, benefits numerous organ systems and decreases the risk for premature mortality. In spite of its fundamental importance, a gap remains in identifying the detailed molecular signals and responses to exercise and its benefits for health and disease prevention. To further knowledge in this emerging area, the Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to generate a molecular map of the effects of acute and chronic exercise. MoTrPAC investigators are conducting preclinical and clinical studies to better understand the systemic effects of exercise across multiple tissues. The preclinical studies were performed on more than 700 rats with the analysis of twenty or more organs per rat. The clinical study involves a large cohort of ~2600 individuals with a range of ages and fitness levels (untrained, trained, highly trained) who will be evaluated physiologically and by molecular probing of blood, muscle and adipose tissues before and after acute and chronic endurance or resistance exercise. Multi-omic analyses (genomics, epigenomics, transcriptomics, proteomics and metabolomics/lipidomics) will be performed followed by state-of-the-art bioinformatics to create a molecular map of exercise. This mapping project will provide a public database that is expected to enhance our understanding of the health benefits of physical activity in many organ systems and potentially provide insight into mitigating diseases through activity.

Sanford, James A.↗

Assigning Optical Absorption Transitions with Light-Induced Crystal Structures: Case Study of a Single-Crystal Nanooptomechanical Transducer

UV/vis absorption spectroscopy affords indirect structural information about the photochemistry and photophysics of molecules by inferring types of electronic transitions from spectral features. Direct structural information would become available, though, if light-induced crystal structures could be mapped against changes in optical absorption spectra as a photochemical process evolves. We present a series of light-induced crystal structures that track real-time changes in solid-state optical absorption spectra of a crystalline nanooptomechanical transducer, while the transduction process unfolds within its crystal lattice at 100 K. Results afford a combined structural and spectral mapping of its solid-state optical absorption, from which the operational mechanism of nanooptomechanical transduction is revealed. Metal-to-ligand and metal-centered charge-transfer bands are assigned to optical absorption peaks directly from their 3-D light-induced crystal structures. This approach could be used to characterize many solid-state optoelectronic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗