Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Titanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Titanium-Carbide Formation at Defective Curved Graphene-Titanium Interfaces

ABSTRACT Physical and chemical properties of graphene-metal interfaces have been largely examined with the objective of producing nanostructured carbon-based electronic devices. Although electronic properties are key to such devices, appropriate structural, thermal and mechanical properties are important for device performance as well. One of the most studied is the graphene-titanium (G-Ti) interface. Titanium is a low density, high strength versatile metal that can form alloys with desirable properties for applications ranging from aerospace to medicine. Small clusters and thin films of titanium deposited on graphene have also been examined. However, while some experiments show that thin films of titanium on graphene can be removed without damaging graphene hexagonal structure, others reported the formation of titanium-carbide (TiC) at G-Ti interfaces. In a previous work [ACS Appl. Mater. Interfaces, 2017, 9 (38), pp 33288-33297], we have shown that pristine G-Ti interfaces are resilient to large thermal fluctuations even when G-Ti structures lie on curved or kinked substrates. Here, using classical molecular dynamics with the third-generation Charge Optimized Many Body (COMB3) potential, we show that di-interstitial defective G-Ti structures on a copper substrate with a relatively large curvature kink, present signs of TiC formation. This result might help explain the different experimental results mentioned above.

catalysis (heterogeneous), defects, membrane, carb↗

Thermal Diffusivity and Specific Heat Measurements of Titanium Potassium Perchlorate Titanium Subhydride Potassium Perchlorate 9013 Glass 7052 Glass SB-14 Glass and C-4000 Muscovite Mica Using the Flash Technique

The flash technique was used to measure the thermal diffusivity and specific heat of titanium potassium perchlorate (TKP) ignition powder (33wt% Ti - 67wt% KP) with Ventron sup- plied titanium particles, TKP ignition powder (33wt% Ti - 67wt% KP) with ATK supplied titanium particles, TKP output powder (41wt% Ti - 59wt% KP), and titanium subhydride potassium perchlorate (THKP) (33wt% TiH 1.65 - 67wt% KP) at 25°C. The influence of density and temperature on the thermal diffusivity and specific heat of TKP with Ventron supplied titanium particles was also investigated. Lastly, the thermal diffusivity and specific heats of 9013 glass, 7052 glass, SB-14 glass, and C-4000 Muscovite mica are presented as a function of temperature up to 300° C.

36 MATERIALS SCIENCE↗

Compaction of Titanium Powders

Accurate modeling of powder densification has been an area of active research for more than 60 years. The earliest efforts were focused on linearization of the data because computers were not readily available to assist with curve-fitting methods. In this work, eight different titanium powders (three different sizes of sponge fines<150 {micro}m,<75 {micro}m, and<45 {micro}m; two different sizes of a hydride-dehydride [HDH]<75 {micro}m and<45 {micro}m; an atomized powder; a commercially pure [CP] Ti powder from International Titanium Powder [ITP]; and a Ti 6 4 alloy powder) were cold pressed in a single-acting die instrumented to collect stress and deformation data during compaction. From these data, the density of each compact was calculated and then plotted as a function of pressure. The results show that densification of all the powders, regardless of particle size, shape, or chemistry, can be modeled accurately as the sum of an initial density plus the sum of a rearrangement term and a work-hardening term. These last two terms are found to be a function of applied pressure and take the form of an exponential rise.

36 MATERIALS SCIENCE↗

Hydrogen-enabled microstructure and fatigue strength engineering of titanium alloys

Traditionally, titanium alloys with satisfactory mechanical properties can only be produced via energy-intensive and costly wrought processes, while titanium alloys produced using low-cost powder metallurgy methods consistently result in inferior mechanical properties, especially low fatigue strength. Herein, we demonstrate a new microstructural engineering approach for producing low-cost titanium alloys with exceptional fatigue strength via the hydrogen sintering and phase transformation (HSPT) process. The high fatigue strength presented in this work is achieved by creating wroughtlike microstructures without resorting to wrought processing. This is accomplished by generating an ultrafine-grained as-sintered microstructure through hydrogen-enabled phase transformations, facilitating the subsequent creation of fatigue-resistant microstructures via simple heat treatments. Finally, the exceptional strength, ductility, and fatigue performance reported in this paper are a breakthrough in the field of low-cost titanium processing.

36 MATERIALS SCIENCE↗

Velocity measurements of inert porous materials driven by infrared-laser-ablated thin-film titanium

This article presents and interprets a series of experiments performed to measure the velocity of four inert low-density porous materials that were accelerated by an ablated thin-film titanium metal, created by vaporizing a 250-nm-thick layer of titanium with a high-energy, Q-switched, pulsed, and 1.054 {mu}m neodymium-glass laser. Inert powder materials were chosen to match, among other characteristics, the morphology of energetic materials under consideration for use in detonator applications. The observed behavior occurs near the thin-film titanium ablation layer, through complex physical mechanisms, including laser absorption in the metal layer, ablation and formation of confined plasma that is a blackbody absorber of the remaining photon energy, and vaporization of the remaining titanium metal. One-dimensional hydrodynamic modeling provided a basis of comparison with the measured velocities. We found, as predicted in wave-propagation-code modeling, that an Asay foil can indicate total momentum of the driven material that is mechanically softer (lower in shock impedance) than the foil. The key conclusion is that the specific impulse delivered by the laser transfers a corresponding momentum to soft, organic power columns that are readily compacted. Impulse from the laser is less efficient in transferring momentum to hard inorganic particles that are less readily compacted.

36 MATERIALS SCIENCE↗

Equilibrium of [Si]/(SiO{sub 2}) in Carbothermic Selective Reduction of Titanium Concentrate Ore for the Preparation of Titanium Oxycarbide

Carbothermic selective reduction of titanium concentrate ore for the preparation of titanium oxycarbide was presented and SiO{sub 2} was found to be partly reduced during the process. The equilibrium relationship between Si dissolved in metallic Fe and SiO{sub 2} existed in corresponding slag was analyzed thermodynamically, and then revealed by a series of designed equilibration experiments. The results are in accordance with the calculated values obtained from thermodynamic analysis and have well explained the phenomenon that part of SiO{sub 2} is reduced during selective reduction processing of titanium concentrate ore.

36 MATERIALS SCIENCE↗

Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer

Purpose: The aim of this study was to characterize the levels of artifacts and distortions of titanium applicators on 3.0-Tesla magnetic resonance imaging (MRI). Methods and Materials: Fletcher-Suit-Delclos-style tandem and ovoids (T and O) and tandem and ring applicator (T and R) were examined. The quality assurance (QA) phantoms for each applicator were designed and filled with copper sulphate solution (1.5 g/l). The artifacts were quantified with the registration of corresponding computed tomography (CT) images. A favorable MR sequence was searched in terms of artifacts. Using the sequence, the artifacts were determined. The geometric distortions induced by the applicators were quantified through each registration of CT and MRI without applicators. The artifacts of T and O were also evaluated on in vivo MRI datasets of 5 patients. Results: T1-weighted MRI with 1-mm slice thickness was found as a favorable MR sequence. Applying the sequence, the artifacts at the tandem tip of T and O and T and R were determined as 1.5 {+-} 0.5 mm in a superior direction in phantom studies. In the ovoids of T and O, we found artifacts less than 1.5 {+-} 0.5 mm. The artifacts of a T and O tandem in vivo were found as less than 2.6 {+-} 1.3 mm on T1-weighted MRI, whereas less than 6.9 {+-} 3.4 mm on T2-weighted MRI. No more than 1.2 {+-} 0.6 mm (3.0 {+-} 1.5 mm) of distortions, due to a titanium applicator, were measured on T1-weighted MRI (T2-). Conclusion: In 3.0-Tesla MRI, we found the artifact widths at the tip of tandem were less than 1.5 {+-} 0.5 mm for both T and O and T and R when using T1-weighted MRI in phantom studies. However, exclusive 3.0-Tesla MRI-guided brachytherapy planning with a titanium applicator should be cautiously implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ Experiments to Capture the Evolution of Microstructure During Phase Transformation of Titanium Under Dynamic Loading

Under sufficient stresses, such as during dynamic loading, titanium experiences a phase transformation from hcp alpha phase to hexagonal omega phase. Omega phase is often retained in the microstructure after unloading, and has a strong influence on subsequent mechanical properties. Simulations suggest there are multiple pathways and underlying mechanisms for this transformation. Due to the incredibly short timescales involved, experimental measurements for model validation have been difficult. However, new capabilities at the Advanced Photon Source have enabled diffraction measurements during plate impact experiments to study the evolution of titanium during transformation. These high-rate data allow us to probe the mechanism and kinetics of phase transformations in new ways. Recent results will be presented and compared to post-mortem characterization of soft-recovered shocked specimens. Comparisons are then made with previous tests where material was shock-loaded and soft recovered for microstructural analysis. Together these techniques create a consistent picture of material behavior during the shock-induced α–ω phase transformation in titanium.

36 MATERIALS SCIENCE↗

Strain heterogeneity and damage nucleation at grain boundaries during monotonic deformation in commercial purity titanium.

Heterogeneous strain was analyzed in polycrystalline, commercial-purity titanium using many experimental techniques that provide information about microstructure, dislocation arrangement, grain orientation, orientation gradients, surface topography, and local strain gradients. The recrystallized microstructure with 50-200 {micro}m grains was extensively characterized before and after deformation using 4-point bending to strains between 2% and 15%. Extremely heterogeneous deformation occurred along some grain boundaries, leading to orientation gradients exceeding 10{sup o} over 10-20 {micro}m. Patches of highly characterized micro-structure were modeled using crystal plasticity finite element (CPFE) analysis to simulate the deformation to evaluate the ability of the CPFE model to capture local deformation processes. Damage nucleation events were identified that are associated with twin interactions with grain boundaries. Progress toward identifying fracture initiation criteria based upon slip and twin interactions with grain boundaries is illustrated with related CPFE simulations of deformation in a TiAl alloy.

36 MATERIALS SCIENCE↗

Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V

A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at the beam center region with an irradiation temperature around 120 oC. Tensile tests showed increased hardness and a large decrease in ductility for the dual a+ß-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near a-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each a-phase grain. The ß-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated ?-phase precipitation in an advanced formation stage. The radiation-induced ?-phase transformation in the ß-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less ß-phase.google scho

Tensile Test, titanium, acclerator, proton beam↗

Synthesis and characterization of titanium-alloyed hematite thin films for photoelectrochemical water splitting

We have synthesized pure and Ti-alloyed hematite thin films on F doped SnO{sub 2} coated glass substrates by radio frequency magnetron co-sputtering of iron oxide and titanium targets in mixed Ar/O{sub 2} and mixed N{sub 2}/O{sub 2} ambient. We found that the hematite films deposited in the N{sub 2}/O{sub 2} ambient exhibit much poorer crystallinity than the films deposited in the Ar/O{sub 2} ambient. We determined that Ti alloying leads to increased electron carrier concentration and crystallinity, and reduced bandgaps. Moreover, Ti-alloyed hematite thin films exhibited improved photoelectrochemical performance as compared with the pure hematite films: The photocurrents were enhanced and the photocurrent onset shifted to less positive potentials.

36 MATERIALS SCIENCE↗

Inelastic titanium-titanium collisions

We have measured cold inelastic collisions between neutral ground-state titanium atoms: collisions that cause transitions between the different magnetic sublevels of the [3d{sup 2}4s{sup 2}]{sup 3}F{sub 2} ground state of {sup 50}Ti, as well as collisions that cause transitions between the fine-structure levels of the [3d{sup 2}4s{sup 2}]{sup 3}F{sub J} electronic ground state. Both processes occur with large rate coefficients, as would be expected from titanium's anisotropic electronic potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

Titanium and germanium lined hohlraums and halfraums as multi-keV x-ray radiators

As multi-keV x-ray radiators, hohlraums and halfraums with inner walls coated with metallic materials (called liner) have been tested for the first time with laser as the energy drive. For titanium, conversion efficiencies (CEs) are up to {approx}14% for emission into 4{pi}, integrating between 4.6 and 6.5 keV when a large diameter hohlraum is used. Germanium CE is {approx}0.8% into 4{pi} between 9 and 13 keV. The highest CEs have been obtained with a 1 ns squared pulse and phase plates giving laser absorption near 99%. These high CEs are due to long-lasting, good plasma conditions for multi-keV x-ray production maintained by plasma confinement inside the plastic cylinder and plasma collision leading to a burst of x rays at a time that depends on target size. As photon emitters at 4.7 keV, titanium-lined hohlraums are the most efficient solid targets and data are close to CEs for gas targets, which are considered as the upper limit for x-ray yields since their low density allows good laser absorption and low kinetics losses. As 10.3 keV x-ray emitters, exploded germanium foils give best results one order of magnitude more efficient than thick targets; doped aerogels and lined hohlraums give similar yields, about three times lower than those from exploded foils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗