The effects of space radiation on a chemically modified graphite-epoxy composite material

The effects of the space environment on the engineering properties and chemistry of a chemically modified T300/934 graphite-epoxy composite system are characterized. The material was subjected to 1.0 x 10 to the 10th power rads of 1.0 MeV electron irradiation under vacuum to simulate 30 years in geosynchronous earth orbit. Monotonic tension tests were performed at room temperature (75 F/24 C) and elevated temperature (250 F/121 C) on 4-ply unidirectional laminates. From these tests, inplane engineering and strength properties (E sub 1, E sub 2, Nu sub 12, G sub 12, X sub T, Y sub T) were determined. Cyclic tests were also performed to characterize energy dissipation changes due to irradiation and elevated temperature. Large diameter graphite fibers were tested to determine the effects of radiation on their stiffness and strength. No significant changes were observed. Dynamic-mechanical analysis demonstrated that the glass transition temperature was reduced by 50 F(28 C) after irradiation. Thermomechanical analysis showed the occurrence of volatile products generated upon heating of the irradiated material. The chemical modification of the epoxy did not aid in producing a material which was more radiation resistant than the standard T300/934 graphite-epoxy system. Irradiation was found to cause crosslinking and chain scission in the polymer. The latter produced low molecular weight products which plasticize the material at elevated temperatures and cause apparent material stiffening at low stresses at room temperature.

Reed, S. M.

Nuclear reactor descriptions for space power systems analysis

For the small, high performance reactors required for space electric applications, adequate neutronic analysis is of crucial importance, but in terms of computational time consumed, nuclear calculations probably yield the least amount of detail for mission analysis study. It has been found possible, after generation of only a few designs of a reactor family in elaborate thermomechanical and nuclear detail to use simple curve fitting techniques to assure desired neutronic performance while still performing the thermomechanical analysis in explicit detail. The resulting speed-up in computation time permits a broad detailed examination of constraints by the mission analyst.

Mccauley, E. W.

A thermal, thermoelastic, and wear simulation of a high-energy sliding contact problem

This paper describes an investigation of the sliding contact problem encountered in high-energy disk brakes. The analysis includes a simulation modeling, using the finite element method, of the thermoelastic instabilities that cause transient changes in contact to occur on the friction surface. In order to include the effect of wear of the concentrated contacts on the friction surface, a wear criterion is proposed that results in prediction of wear rates for disk brakes that are quite close to experimentally determined wear rates. The thermal analysis shows that the transient temperature distribution in a disk brake can be determined more accurately by use of this thermomechanical analysis than by a more conventional analysis that assumes constant contact conditions. It is also shown that lower, more desirable, temperatures in disk brakes can be attained by increasing the volume, the thermal conductivity, and especially, the heat capacity of the brake components.

Kennedy, F. E., Jr.

Influence of electron radiation and temperature on the cyclic, matrix dominated response of graphite-epoxy

The effects of electron radiation and elevated temperature on the matrix-dominated cyclic response of standard T300/934 and a chemically modified T300/934 graphite-epoxy are characterized. Both materials were subjected to 1.0 x 10 to the 10th rads of 1.0 MeV electron irradiation, under vacuum, to simulate 30 years in geosynchronous orbit. Cyclic tests were performed at room temperature and elevated temperature (121 C) on 4-ply unidirectional laminates to characterize the effects associated with irradiation and elevated temperature. Both materials exhibited energy dissipation in their response at elevated temperature. The irradiated modified material also exhibited energy dissipation at room temperature. The combination of elevated temperature and irradiation resulted in the most severe effects in the form of lower proportional limits, and greater energy dissipation. Dynamic-mechanical analysis demonstrated that the glass transition temperature, T(g), of the standard material was lowered 39 C by irradiation, wereas the T(g) of the modified material was lowered 28 C by irradiation. Thermomechanical analysis showed the occurrence of volatile products generated upon heating of the irradiated materials.

Reed, Susan M.

User's Manual and Final Report for Hot-SMAC GUI Development

A new software package called Higher Order Theory-Structural/Micro Analysis Code (HOT-SMAC) has been developed as an effective alternative to the finite element approach for Functionally Graded Material (FGM) modeling. HOT-SMAC is a self-contained package including pre- and post-processing through an intuitive graphical user interface, along with the well-established Higher Order Theory for Functionally Graded Materials (HOTFGM) thermomechanical analysis engine. This document represents a Getting Started/User's Manual for HOT-SMAC and a final report for its development. First, the features of the software are presented in a simple step-by-step example where a HOT-SMAC model representing a functionally graded material is created, mechanical and thermal boundary conditions are applied, the model is analyzed and results are reviewed. In a second step-by-step example, a HOT-SMAC model of an actively cooled metallic channel with ceramic thermal barrier coating is built and analyzed. HOT-SMAC results from this model are compared to recently published results (NASA/TM-2001-210702) for two grid densities. Finally, a prototype integration of HOTSMAC with the commercially available HyperSizer(R) structural analysis and sizing software is presented. In this integration, local strain results from HyperSizer's structural analysis are fed to a detailed HOT-SMAC model of the flange-to-facesheet bond region of a stiffened panel. HOT-SMAC is then used to determine the peak shear and peel (normal) stresses between the facesheet and bonded flange of the panel and determine the "free edge" effects.

Yarrington, Phil

Addition Curing Thermosets Endcapped with 4-Amino (2.2) Paracyclophane

A new family of addition curing polyimides were prepared that contained 4-amino (2.2)-paracyclophane as the endcap. An improved synthesis of the endcap 4-amino-(2.2) cyclophane was accomplished increasing the yield to 60 percent and simplifying the procedure. DSC and rheological analysis of endcapped polyimide oligomers confirmed that the onset for polymerization of the ethylene bridge was 250 C. C-13 CP/MAS NMR was used to determine the structural changes of the oligomers after thermal treatment. The cyclophane capped polyimides were successfully compression molded to form void free neat resin specimens. Tg's as high as 353 C were obtained by thermomechanical analysis for postcured samples. Preliminary thermal stability studies suggest that these resins have a high onset of decomposition ranging from 549 to 567 C.

Waters, John F.

Measuring thermomechanical response of large-format printed polymer composite structures via digital image correlation

Large-format additive manufacturing (LFAM) is a branch of additive manufacturing (AM) research with the ability to create large structures typically measuring several meters in scale. LFAM is advantageous for tooling applications, not only because it offers the ability to create complex geometries not easily made using subtractive manufacturing processes, but the cost savings of pelletized feedstock used by these systems result in larger parts printed at faster speeds than traditional AM systems. Fiber reinforced polymer (FRP) is a commonly used feedstock material in LFAM structures because it reduces the distortion experienced during printing. However, FRP introduces highly anisotropic thermomechanical properties and contributes to a nonhomogeneous microstructure that can result in critical distortion of dimensions during tooling. Measuring the global thermomechanical response of LFAM structures requires a more representative method that accounts for not only anisotropic properties but also the nonhomogeneous nature of the final part. This is where traditional techniques to measure thermomechanical response, such as thermomechanical analysis (TMA), fall short as they assume homogeneity. This study evaluated the coefficient of thermal expansion (CTE) of LFAM structures as measured by TMA as compared to a novel digital image correlation oven (DIC Oven) system. The LFAM structures were made from 20 % by weight carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS). TMA measurements showed significant variations in CTE across a single LFAM bead, confirming the need for a global technique that captures overall thermomechanical response. The CTE values measured using the DIC Oven compared well to average TMA values obtained from localized measurements across the sample. The DIC Oven was also used to quantify the effects of different layer orientations on thermomechanical properties, which cannot be easily captured using TMA. A predictive model was also developed by using localized TMA values across an LFAM bead to predict the overall thermomechanical response of an LFAM structure.

36 MATERIALS SCIENCE

Chemical and Thermal Analysis

Thermal decomposition activation energies have been determined using two methods of Thermogravimetric Analysis (TGA), with good correlation being obtained between the two techniques. Initial heating curves indicated a two-component system for Coflon (i.e. polymer plus placticizer) but a single component system for Tefzel. Two widely differing activation energies were for Coflon supported this view, 15 kcl/mol being associated with plasticizer, and 40 kcal/mol with polymer degradation. With Tefzel, values were 40-45 kcal/mol, the former perhaps being associated with a low molecular weight fraction. Appropriate acceleration factors have been determined. Thermomechanical Analysis (TMA) has shown considerable dimensional change during temperature cycles. For unaged pipe sections heating to 100 C and then holding the temperature resulted in a stable thickness increase of 2%, whereas the Coflon thickness decreased continuously, reaching -4% in 2.7 weeks. Previously strained tensile bars of Tefzel expanded on cooling during TMA. SEM performed on H2S-aged Coflon samples showed significant changes in both physical and chemical nature. The first may have resulted from explosive decompression after part of the aging process. Chemically extensive dehydrofluorination was indicated, and sulfur was present as a result of the aging. These observations indicate that chemical attack of PVDF can occur in some circumstances.

Bulluck, J. W.

Effect of Molding and Machining on Neoflon CTFE M400H Polychlorotrifluoroethylene Rod Stock and Valve Seat Properties

Since 1997 numerous fires have been reported to the Food and Drug Administration involving cylinder valves installed on medical use oxygen cylinders sold and operated within the United States. All of the cylinder valves in question had polychlorotrifluoroethylene (PCTFE) valve seats. Subsequent failure analysis showed that the main seat was the primary source of ignition. A review of the incidents involving cylinder valve fires indicated three possible ignition mechanisms: contaminant promotion, flow friction, and resonance. However, gas purity analysis showed that uncombusted, residual oxygen was within specification. Infrared and energy dispersive spectroscopy further showed that no contaminants or organic compounds were present in the remaining, uncombusted valve seat material or on seat plug surfaces. Therefore, contaminant-promoted ignition did not appear to be responsible for the failures. Observations of extruded material along the outer edge of the coined or loaded seat area produced by cylinder overuse or poppet overload led to concerns that accelerated gas flow across a deformed seat surface could generate enough localized heating to ignite the polymeric seat. Low molecular weight or highly amorphous quick-quenched PCTFE grades might be expected to be especially prone to this type of deformation. Such a failure mechanism has been described as flow friction; however, the corresponding mechanistic parameters are poorly understood. Subsequent revelation of low-temperature dimensional instability by thermomechanical analysis (TMA) in a variety of PCTFE sheet and rod stock samples led to new concerns that PCTFE valve seats could undergo excessive expansion or contraction during service. During expansion, additional extrusion and accompanying flow friction could occur. During contraction, a gap between the seal and adjacent metal surfaces could form. Gas flowing past the gap could, in turn, lead to resonance heating and subsequent ignition as described in ASTM Guide for Evaluation Nonmetallic Materials for Oxygen Service (G 63). Attempts to uncover the origins of the observed dimensional instability were hindered by uncertainties about resin grade, process history, and post-process heat history introduced by machining, annealing, and sample preparation. An approach was therefore taken to monitor property changes before and after processing and machining using a single, well-characterized lot of Neoflon CTFE.1 M400H resin. A task group consisting of the current PCTFE resin supplier, two molders, and four valve seat manufacturers was formed, and phased testing on raw resin, intermediate rod stock, and finished valve seats initiated. The effect of processing and machining on the properties of PCTFE rod stock and oxygen gas cylinder valve seats was then determined. Testing focused on two types of extruded rod stock and one type of compression-molded rod stock. To accommodate valve seat manufacturer preferences for certain rod stock diameters, two representative diameters were used (4.8 mm (0.1875 in.) and 19.1 mm (0.75 in.)). To encompass a variety of possible sealing configurations, seven different valve seat types with unique geometries or machining histories were tested. The properties investigated were dimensional stability as determined by TMA, specific gravity, differential scanning calorimetry (DSC), compressive strength, zero strength time, and intrinsic viscosity. Findings are discussed in the context of polymer structure-process-property relationships whenever possible.

Waller, Jess M.

High Modulus and High T(sub g) Thermally Stable Polymers from p-Ethynyl-Terminated Rigid-Rod Monomers

Novel p-ethynyl-substituted rigid rod monomers were studied by pressure Differential Scanning Calorimetry (DSC), ThermoGravimetric Analysis (TGA), IsothermoGravimetric Analysis (IGA), and TGA-IR. These monomers, 4,4'-bis(((4-ethynylphenyl)carbonyl)oxy)biphenyl, designated 1, 1,5-bis-(((4-ethynylphenyl)carbonyl)oxy)naphthalene, designated 2, and bis(4-ethynylphenyl)pyromellitimide, designated 3, were polymerized in the solid state. Thermal polymerization in N2 or air produced highly cross-linked resins with polymerization exotherms centered between 212 and 276 C. The (delta)H's of polymerization of these resins in air were found to be double those in N2. When monomers 1 and 2 were heated in air from 23 to 750 C at 10 C/min, the main decomposition product was carbon dioxide, evolving at a maximum rate between 500 and 600 C; water was also detected as a decomposition product. Void-free neat resin moldings, designated lp to 3p, were made by compression molding the monomers and then heating them. The resulting polymers were highly cross-linked, and their glass transition temperatures (T(sub g)) were much higher than their polymerization temperatures. Using ThermoMechanical Analysis (TMA), we found that polymers lp to 3p had T(sub g)'s of 422, 329, and 380 C, respectively. The thermal and thermooxidative stabilities improved when lp to 3p were postcured in N2 (the postcured polymers were designated 1pp to 3pp). The Linear Thermal Expansions (LTE) for lp and 3p were 1% between 23 and 420 C. Using rheological analysis, we could not clearly detect the T(sub g)'s of lp to 3p because their moduli dropped only slightly between 23 and 490 C and the changes in tan beta were very low. Because of high cross-link density, their moduli changed little as the resins went from a glassy to a rubbery state. Their shear storage moduli in air ranged from 0.82 (3p, 3pp) to 1.6 GPa (lpp) at 23 C, from 0.16 (2p) to 0.7GPa(lpp) at 380 C, and from 0.18(lpp)to 0.6GPa(2p) at 490 C. Finally, these novel-p-ethynyl polymers exhibited an excellent combination of high T(sub g), low LTE, and high thermooxidative stability. Most notably, 3pp lost only 3% of its initial weight when it was aged for 500 h at 288 C in air.

Melissaris, Anastasios P.

Thermo-rheological snapshot of melter feed conversion to glass

Slurry feed charged into an electric melter creates a layer of reacting and melting material (termed cold cap) that floats on the surface of molten glass. The rheological behavior of heated melter feed affects the spreading of slurry at the top of the cold cap and the stability of the primary foam, affecting cold-cap coverage and melter plenum temperatures. The apparent viscosity of a high-alumina high-level waste melter feed was assessed by thermomechanical analysis, high-temperature viscometer, and the hot stage microscopy method, yielding viscosity estimates from ≈10 7.5 Pa s at 550°C to ≈10 2.5 Pa s at 1050°C. As the temperature of feed materials increased, their state changed from rigid solid to dilatant fluid, to pseudoplastic bubbly liquid with dissolving solids, to fully developed foam, and finally to Newtonian glass melt.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

High Temperature Adhesives for Bonding Kapton

Experimental polyimide resins were developed and evaluated as potential high temperature adhesives for bonding Kapton polyimide film. Lap shear strengths of Kapton/Kapton bonds were obtained as a function of test temperature, adherend thickness, and long term aging at 575K (575 F) in vacuum. Glass transition temperatures of the polyimide/Kapton bondlines were monitored by thermomechanical analysis.

Stclair, A. K.

High temperature adhesives for bonding Kapton

Experimental polyimide resins have been developed and evaluated as potential high temperature adhesives for bonding Kapton polyimide film. Lap shear strengths of 'Kapton'/'Kapton' bonds were obtained as a function of test temperature, adherend thickness, and long term aging at 575K (575 F) in vacuum. Glass transition temperatures of the polyimide/'Kapton' bondlines were monitored by thermomechanical analysis.

Saint Clair, A. K.

High-temperature adhesives for bonding polyimide film

Experimental polyimide resins were developed and evaluated as potential high temperature adhesives for bonding Kapton polyimide film. Lap shear strengths of Kapton/Kapton bonds were obtained as a function of test temperature, adherend thickness, and long term aging at 575 K (575 F) in vacuum. Glass transition temperatures of the polyimide/"Kapton" bondlines were monitored by thermomechanical analysis.

St.clair, A. K.

Incorporation of metal ions into polyimides

The effects of the incorporation of metal ions into various polyimides on polyimide properties are investigated. Polyimide films derived from 3,3',4,4'-benzophenone tetracarboxylic acid dianhydride (BDTA) 3,3'-diaminobenzophenone (m,m'-DABP), 4,4'-diaminobenzophenone (p,p'-DABP) or 4,4'-oxydianiline were prepared with the concurrent addition of approximately 20 metals in a variety of forms. In general, it is found that the films derived from BDTA + p,p'-DABP were brittle and of poor quality, with brittle films also produced in most of the BDTA + m, m'-DABP polyimides regardless of whether the added metal was hydrate or anhydrous. Thermomechanical analysis, torsional braid analysis, thermal gravimetric analysis, infrared spectral analysis and isothermal studies on many of the polyimide films produced indicate that the softening temperature is generally increased upon the addition of metal ions, at the expense of thermal stability, while no changes in chemical functionality are observed. The best system studied in regard to polymer property enhancement appears to be tri(acetylacetonato)aluminum(III) added to the m, m'-DABP polyamide, which has been found to exhibit four times the lap shear strength of the polyimide alone.

Taylor, L. T.

Metal ion-containing epoxies

A variety of metallic and organometallic complexes to be used as potential additives for an epoxy used by the aerospace industry as a composite matrix resin were investigated. A total of 9 complexes were screened for compatibility and for their ability to accelerate or inhibit the cure of a highly crosslinkable epoxy resin. Methods for combining the metallic complexes with the resin were investigated, gel times recorded, and cure exotherms studied by differential scanning calorimetry. Glass transition temperatures of cured metal ion containing epoxy castings were determined by thermomechanical analysis. Thermal stabilities of the castings were determined by thermogravimetric analysis. Mechanical strength and stiffness of these doped epoxies were also measured.

Stoakley, D. M.

Experimental and analytical study of ceramic-coated turbine-tip shroud seals for small turbine engines

The results of an experimental and analytical evaluation of ceramic turbine tip shrouds within a small turbine engine operating environment are presented. The ceramic shrouds were subjected to 1001 cycles between idle and high power and steady-state conditions for a total of 57.8 engine hr. Posttest engine inspection revealed mud-flat surface cracking, which was attributed to microcracking under tension with crack penetration to the ceramic and bond coat interface. Sections and micrographs tend to corroborate the thesis. The engine test data provided input to a thermomechanical analysis to predict temperature and stress profiles throughout the ceramic gas-path seal. The analysis predicts cyclic thermal stresses large enough to cause the seal to fail. These stresses are, however, mitigated by inelastic behavior of the shroud materials and by the microfracturing that tensile stresses produce. Microfracturing enhances shroud longevity during early life but provides the failure mechanism during life but provides the failure mechanism during extended life when coupled with the time dependent inelastic materials effects.

Biesiadny, T. J.

Development of new materials for turbopump bearings

The life requirement for the angular contact ball bearings in the Space Shuttle Main Engine (SSME) high pressure oxygen turbopump (HPOTP) is 7.5 hours. In actual operation, significantly shorter service life was experienced. The objective is to identify bearing materials and/or materials processing techniques offering signficant potential for extending HPOTP bearing performance life. Interactive thermomechanical analysis of the HPOTP bearing-shaft system was performed with the SHABERTH computer program. Bearing fatigue life, ball-race contact stress, heat generation rate, bulk ring temperatures and circumferential stress in the inner rings were quantified as functions of radial load, thrust load and ball-race contact friction. Criteria established from the output of this analysis are being used for material candidate selection.

Maurer, R. E.